Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is FLARION-PHYS-MIB?
FLARION-PHYS-MIB is a Flarion Technologies (early mobile-broadband/Flash-OFDM vendor, later Qualcomm) proprietary MIB reporting chassis physical inventory. Its objects cover chassis type/revision/max-slots/card count, a chassis-slot table (slot ID, hardware type/name/status/version/ESN, software version), physical chassis type, serial number, production date, part number, hardware version, RF band, assembly ID, a fan table (index, OK flag), and a relay table. As a hardware-status MIB it lets an administrator confirm slot hardware inventory and fan health on a Flarion Technologies (Qualcomm) mobile-broadband chassis. It is deployed on Flarion Technologies (Qualcomm) mobile-broadband base-station equipment. Engineers can download the FLARION-PHYS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in FLARION-PHYS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Flarion Technologies (Qualcomm) mobile-broadband base-station equipment
Monitoring Examples
An administrator checks rrChassisSlotHwStatus and phyFanOk to confirm slot hardware health and fan status on a Flarion Technologies (Qualcomm) base-station chassis.
What Can Be Monitored
- chassis slot hardware inventory and fan health
This MIB depends on
Related MIBs
Imported Objects
From FLARION-MIB
| AdminState | |
| FloatAsString | |
| MoType | |
| rrBaseBandUnit | OBJECT-IDENTITY |
| rrManagedObjs | OBJECT-IDENTITY |
| rrMib | OBJECT-IDENTITY |
From RFC1155-SMI
| enterprises |
From SNMPv2-SMI
| Counter32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| TimeTicks | |
| Unsigned32 |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| RowStatus | |
| TruthValue |
How to Use in IPNetwork Monitor
Example using paTemperature OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| bbuSysTable | 1.3.6.1.4.1.8603.1.2.1.2.5 | not-accessible | Base Band Unit system information. | |
| bbuSysEntry | 1.3.6.1.4.1.8603.1.2.1.2.5.1 | not-accessible | Base Band Unit system table entry. | |
| INT bbuSysId | 1.3.6.1.4.1.8603.1.2.1.2.5.1.1 | INTEGER | read-only | This identifies a single BBU in a basestation. |
| STR bbuDspVer | 1.3.6.1.4.1.8603.1.2.1.2.5.1.2 | DisplayString | read-only | The read-only statistic indicates the version number of the DSP software currently operational on the sector in question. It has the major.minor.micro notation. |
| STR bbuLlcVer | 1.3.6.1.4.1.8603.1.2.1.2.5.1.3 | DisplayString | read-only | The read-only statistic indicates the version number of the Link List Controller software/firmware currently operational on the sector in question. It has the major.minor notation. |
| STR bbuTxFpgaVer | 1.3.6.1.4.1.8603.1.2.1.2.5.1.4 | DisplayString | read-only | The read-only statistic indicates the version number of the Tx FPGA software/firmware currently operational on the sector in question. It has the major.minor notation. |
| STR bbuRxFpgaVer | 1.3.6.1.4.1.8603.1.2.1.2.5.1.5 | DisplayString | read-only | The read-only statistic indicates the version number of the Rx FPGA software/firmware currently operational on the sector in question. It has the major.minor notation. |
| U32 bbuLdpcVer | 1.3.6.1.4.1.8603.1.2.1.2.5.1.6 | Unsigned32 | read-only | The read-only statistic indicates the version number of the LDPC encoder/decoder software/firmware currently operational on the sector in question. It has the major.minor notation. |
| INT bbuRfChanNum | 1.3.6.1.4.1.8603.1.2.1.2.5.1.50 | INTEGER | read-write | The RF channel number, in conjunction with the bbuRffBand object defines the frequency of operation. The channel number follows well-known ITU numbering, and represents 50 kHz spacing. The step size depends on the band. In the 1.9 GHz band, the step size is 4 (200 kHz). Editable offline. |
| INT bbuExtGainTx | 1.3.6.1.4.1.8603.1.2.1.2.5.1.51 | INTEGER | read-write | Represents the total external gain in the Tx path. Typically it equals PA gain minus any attenuators. The value is in dB * 32 (scaled by 32). E.g., default value is 43 dB, which is the PA gain, and is represented as 43*32 = 1376. This parameter is used to assist the mobile in making an access attempt at an appropriate power level. The step size is 1 dB. Editable online. |
| INT bbuExtGainRx | 1.3.6.1.4.1.8603.1.2.1.2.5.1.52 | INTEGER | read-write | Represents the total external gain in the Rx path. Typically it equals LNA gain minus any attenuators. The value is in dB * 32 (scaled by 32). E.g., default value is 31 dB, which is the LNA gain, and is represented as 31*32 = 992. This parameter is used to assist the mobile in making an access attempt at an appropriate power level. The step size is 1 dB. Editable online. |
| INT bbuRfGainRx0 | 1.3.6.1.4.1.8603.1.2.1.2.5.1.53 | INTEGER | read-write | Represents the gain (in dB) provided by the RF Rx blade(RXU) in the Rx0 path. This gain is in addition to the gain provided by the LNA. This value is typically calibrated and set in the factory. The step size is 1 dB. Editable online. |
| INT bbuRfGainRx1 | 1.3.6.1.4.1.8603.1.2.1.2.5.1.54 | INTEGER | read-write | Represents the gain (in dB) provided by the RF Rx blade(RXU) in the Rx1 path. This gain is in addition to the gain provided by the LNA. This value is typically calibrated and set in the factory. The step size is 1 dB. Editable online. |
| INT bbuRfBand | 1.3.6.1.4.1.8603.1.2.1.2.5.1.55 | INTEGER | read-write | The band of operation, represented by an enumeration. E.g., the 1.9 GHz PCS band has a value of 6, while the 2.1 GHz UMTS band has a value of 7. This quantity, in conjunction with the bbuRfChanNum decides the frequency of operation. Editable offline. |
| INT bbuRfPowerTx0 | 1.3.6.1.4.1.8603.1.2.1.2.5.1.56 | INTEGER | read-write | Represents the signal strength in dBm of the Tx signal put out on Tx0 by the TXU. An increase in this implies an increase in the signal input to the PA. Step size is 1 dBm. Editable online. |
| INT bbuRfPowerTx1 | 1.3.6.1.4.1.8603.1.2.1.2.5.1.57 | INTEGER | read-write | Represents the signal strength in dBm of the Tx signal put out on Tx1 by the TXU. An increase in this implies an increase in the signal input to the PA. Step size is 1 dBm. Editable online. |
| INT bbuRfuEnableMask | 1.3.6.1.4.1.8603.1.2.1.2.5.1.59 | INTEGER | read-write | This is a bit mask to choose between the 0 and 1 channels for Rx and Tx. The value should be an OR of the channels selected, where: Tx0 = 0001 Tx1 = 0010 Rx0 = 0100 Rx1 = 1000 For example, set this object to 6 if Rx0 and Tx1 need to be enabled. |
| STR bbuExtTxGain | 1.3.6.1.4.1.8603.1.2.1.2.5.1.60 | FloatAsString | read-write | External Tx gain. Valid range is -50.0 to 70.0. |
| STR bbuExtRxGain | 1.3.6.1.4.1.8603.1.2.1.2.5.1.61 | FloatAsString | read-write | External Rx gain. Valid range is -50.0 to 70.0. |
| STR bbuRfRx0Gain | 1.3.6.1.4.1.8603.1.2.1.2.5.1.62 | FloatAsString | read-write | Represents the gain (in dB) provided by the RF Rx blade(RXU) in the Rx0 path. This gain is in addition to the gain provided by the LNA. This value is typically calibrated and set in the factory. The step size is 1 dB. Valid range is -10.0 to 75.0. Editable online. |
| STR bbuRfRx1Gain | 1.3.6.1.4.1.8603.1.2.1.2.5.1.63 | FloatAsString | read-write | Represents the gain (in dB) provided by the RF Rx blade(RXU) in the Rx1 path. This gain is in addition to the gain provided by the LNA. This value is typically calibrated and set in the factory. The step size is 1 dB. Valid range is -10.0 to 75.0. Editable online. |
| STR bbuRfTx0Power | 1.3.6.1.4.1.8603.1.2.1.2.5.1.64 | FloatAsString | read-write | Represents the signal strength in dBm of the Tx signal put out on Tx0 by the TXU. An increase in this implies an increase in the signal input to the PA. Step size is 1 dBm. Valid range is -20.0 to 10.0. Editable online. |
| STR bbuRfTx1Power | 1.3.6.1.4.1.8603.1.2.1.2.5.1.65 | FloatAsString | read-write | Represents the signal strength in dBm of the Tx signal put out on Tx1 by the TXU. An increase in this implies an increase in the signal input to the PA. Step size is 1 dBm. Valid range is -20.0 to 10.0. Editable online. |
| INT bbuTxPwrDeviationLimit | 1.3.6.1.4.1.8603.1.2.1.2.5.1.66 | INTEGER | read-write | |
| INT bbuSlope | 1.3.6.1.4.1.8603.1.2.1.2.5.1.70 | INTEGER | read-write | Represents the slope of the RR sector. It is an identifier which allows a mobile to distinguish between signals from different basestations. There are 112 possible slope values, however, only 80 of these are considered valid values. Editable offline. |
| INT bbuMcastSnr | 1.3.6.1.4.1.8603.1.2.1.2.5.1.71 | INTEGER | read-write | |
| INT bbuScmType | 1.3.6.1.4.1.8603.1.2.1.2.5.1.72 | INTEGER | read-write | |
| INT bbuSleepInactivityTimer | 1.3.6.1.4.1.8603.1.2.1.2.5.1.91 | INTEGER | read-write | Represents the amount of time of data inactivity (on the forward or reverse links) after which a mobile moves to the Sleep state. In units of 1/3 seconds [ eg. Value = 180 represents 60 seconds]. This time period is conveyed to the mobile at the time of establishing connectivity with the basestation. This quantity is non-linearly quantized, so the actual duration of inactivity before sleep may be slightly different from this value. Step size is 1/3 second. Range is 0 to 20 minutes. 0 means never go to sleep. Recommended value is 180 (i.e., 60sec). Editable online. |
| INT bbuLuTimer | 1.3.6.1.4.1.8603.1.2.1.2.5.1.100 | INTEGER | read-write | Periodicity, in seconds, of location update done by a stationary mobile. This time period is conveyed to the mobile at the time of establishing connectivity with the RR. This quantity is non-linearly quantized, so the actual duration of location update may be slightly different from this value. Step size is 1 second. Range is 5 seconds to 18 hours. Editable online. |
| rrChassis | 1.3.6.1.4.1.8603.1.2.1.8 | |||
| CHA rrChassisType | 1.3.6.1.4.1.8603.1.2.1.8.1 | ChassisType | read-only | The chassis revision. |
| STR rrChassisRev | 1.3.6.1.4.1.8603.1.2.1.8.2 | DisplayString | read-only | The chassis revision. |
| INT rrChassisMaxSlots | 1.3.6.1.4.1.8603.1.2.1.8.3 | INTEGER | read-only | Maximum number of slots in the chassis. |
| INT rrChassisNumCards | 1.3.6.1.4.1.8603.1.2.1.8.4 | INTEGER | read-only | Number of cards detected in the chassis. |
| rrChassisTable | 1.3.6.1.4.1.8603.1.2.1.8.5 | not-accessible | Table containing chassis card information. | |
| rrChassisTableEntry | 1.3.6.1.4.1.8603.1.2.1.8.5.1 | not-accessible | RadioRouter chassis card table entry. | |
| INT rrChassisSlotId | 1.3.6.1.4.1.8603.1.2.1.8.5.1.1 | INTEGER | read-only | The chassis slot of the card. |
| MOT rrChassisSlotHwType | 1.3.6.1.4.1.8603.1.2.1.8.5.1.2 | MoType | read-only | The card type. |
| STR rrChassisSlotHwName | 1.3.6.1.4.1.8603.1.2.1.8.5.1.3 | DisplayString | read-only | The card name. |
| CAR rrChassisSlotHwStatus | 1.3.6.1.4.1.8603.1.2.1.8.5.1.4 | CardOpState | read-only | The card hardware operational status. |
| STR rrChassisSlotHwVer | 1.3.6.1.4.1.8603.1.2.1.8.5.1.5 | DisplayString | read-only | The card hardware version number. |
| OCT rrChassisSlotHwEsn | 1.3.6.1.4.1.8603.1.2.1.8.5.1.6 | OCTET STRING | read-only | The card Electronic Serial Number. |
| STR rrChassisSlotSwVer | 1.3.6.1.4.1.8603.1.2.1.8.5.1.8 | DisplayString | read-only | The card IPMI (Intelligent Platform Management Interface) firmware version number. |
| rrPhyShelf | 1.3.6.1.4.1.8603.1.2.3 | |||
| CHA phyChassisType | 1.3.6.1.4.1.8603.1.2.3.1 | ChassisType | read-only | Chassis type. |
| STR phySerialNumber | 1.3.6.1.4.1.8603.1.2.3.2 | DisplayString | read-only | Chassis serial number. |
| STR phyProductionDate | 1.3.6.1.4.1.8603.1.2.3.3 | DisplayString | read-only | Chassis production date (mm/dd/yyyy). |
| STR phyPartNumber | 1.3.6.1.4.1.8603.1.2.3.4 | DisplayString | read-only | Chassis part number. |
| STR phyHardwareVersion | 1.3.6.1.4.1.8603.1.2.3.5 | DisplayString | read-only | Chassis hardware version. |
| RFB phyChassisRfBand | 1.3.6.1.4.1.8603.1.2.3.6 | RfBand | read-only | Chassis RF band. |
| STR phyAssemblyId | 1.3.6.1.4.1.8603.1.2.3.7 | DisplayString | read-only | Chassis assembly ID. |
| phyFanTable | 1.3.6.1.4.1.8603.1.2.3.10 | not-accessible | ||
| phyFanEntry | 1.3.6.1.4.1.8603.1.2.3.10.1 | not-accessible | ||
| INT phyFanIndex | 1.3.6.1.4.1.8603.1.2.3.10.1.1 | INTEGER | read-only | Fan index. |
| T/F phyFanOk | 1.3.6.1.4.1.8603.1.2.3.10.1.2 | TruthValue | read-only | Fan status. |
| phyRelayTable | 1.3.6.1.4.1.8603.1.2.3.11 | not-accessible | ||
| phyRelayEntry | 1.3.6.1.4.1.8603.1.2.3.11.1 | not-accessible | ||
| INT phyRelayIndex | 1.3.6.1.4.1.8603.1.2.3.11.1.1 | INTEGER | read-only | Relay index. |
| STR phyRelayName | 1.3.6.1.4.1.8603.1.2.3.11.1.2 | DisplayString | read-write | Relay name. |
| REL phyRelayState | 1.3.6.1.4.1.8603.1.2.3.11.1.3 | RelayState | read-only | Relay state. |
| phyAlarmInputTable | 1.3.6.1.4.1.8603.1.2.3.12 | not-accessible | ||
| phyAlarmInputEntry | 1.3.6.1.4.1.8603.1.2.3.12.1 | not-accessible | ||
| INT phyAlarmInputIndex | 1.3.6.1.4.1.8603.1.2.3.12.1.1 | INTEGER | read-only | AlarmInput index. |
| T/F phyAlarmInputEnable | 1.3.6.1.4.1.8603.1.2.3.12.1.2 | TruthValue | read-write | AlarmInput enable. |
| STR phyAlarmInputName | 1.3.6.1.4.1.8603.1.2.3.12.1.3 | DisplayString | read-write | AlarmInput name. |
| T/F phyAlarmInputState | 1.3.6.1.4.1.8603.1.2.3.12.1.4 | TruthValue | read-only | AlarmInput state. |
| phyPcuTable | 1.3.6.1.4.1.8603.1.2.3.13 | not-accessible | ||
| phyPcuEntry | 1.3.6.1.4.1.8603.1.2.3.13.1 | not-accessible | ||
| INT phyPcuIndex | 1.3.6.1.4.1.8603.1.2.3.13.1.1 | INTEGER | read-only | PCU index. |
| T/F phyPcuPowerFail | 1.3.6.1.4.1.8603.1.2.3.13.1.2 | TruthValue | read-only | PCU power fail. |
| phyAiuTable | 1.3.6.1.4.1.8603.1.2.3.14 | not-accessible | ||
| phyAiuEntry | 1.3.6.1.4.1.8603.1.2.3.14.1 | not-accessible | ||
| INT phyAiuIndex | 1.3.6.1.4.1.8603.1.2.3.14.1.1 | INTEGER | read-only | AIU index. |
| CAR phyAiuOpState | 1.3.6.1.4.1.8603.1.2.3.14.1.2 | CardOpState | read-only | AIU operational state. |
| CAR phyAiuFaultLed | 1.3.6.1.4.1.8603.1.2.3.14.1.3 | CardFaultLed | read-only | AIU fault LED color. |
| CAR phyAiuTempStatus | 1.3.6.1.4.1.8603.1.2.3.14.1.4 | CardTempStatus | read-only | AIU temperature status. |
| CAR phyAiuVoltageStatus | 1.3.6.1.4.1.8603.1.2.3.14.1.5 | CardVoltageStatus | read-only | AIU voltage status. |
| STR phyAiuSerialNumber | 1.3.6.1.4.1.8603.1.2.3.14.1.6 | DisplayString | read-only | AIU serial number. |
| STR phyAiuProductionDate | 1.3.6.1.4.1.8603.1.2.3.14.1.7 | DisplayString | read-only | AIU production date. |
| STR phyAiuPartNumber | 1.3.6.1.4.1.8603.1.2.3.14.1.8 | DisplayString | read-only | AIU part number. |
| STR phyAiuDescription | 1.3.6.1.4.1.8603.1.2.3.14.1.9 | DisplayString | read-only | AIU description. |
| STR phyAiuHardwareVersion | 1.3.6.1.4.1.8603.1.2.3.14.1.10 | DisplayString | read-only | AIU hardware version. |
| STR phyAiuIpmiSwVersion | 1.3.6.1.4.1.8603.1.2.3.14.1.11 | DisplayString | read-only | AIU IPMI software version. |
| STR phyAiuAssemblyId | 1.3.6.1.4.1.8603.1.2.3.14.1.12 | DisplayString | read-only | AIU assembly ID. |
| ASS phyAiuAssemblyIdSrc | 1.3.6.1.4.1.8603.1.2.3.14.1.13 | AssemblyIdSource | read-only | AIU assembly ID source. |
| T/F phyAiuExcessiveFakeAid | 1.3.6.1.4.1.8603.1.2.3.14.1.14 | TruthValue | read-only | This object is true(1) if the assembly ID is programmed under more than one source. |
| ADM phyAiuAdminState | 1.3.6.1.4.1.8603.1.2.3.14.1.20 | AdminState | read-write | AIU administrative state. |
| T/F phyAiuRebootRr | 1.3.6.1.4.1.8603.1.2.3.14.1.21 | TruthValue | read-write | Setting this object to true(1) will power cycle the RadioRouter chassis! |
| phyMcuTable | 1.3.6.1.4.1.8603.1.2.3.15 | not-accessible | ||
| phyMcuEntry | 1.3.6.1.4.1.8603.1.2.3.15.1 | not-accessible | ||
| INT phyMcuIndex | 1.3.6.1.4.1.8603.1.2.3.15.1.1 | INTEGER | read-only | MCU index. |
| CAR phyMcuOpState | 1.3.6.1.4.1.8603.1.2.3.15.1.2 | CardOpState | read-only | MCU operational state. |
| CAR phyMcuFaultLed | 1.3.6.1.4.1.8603.1.2.3.15.1.3 | CardFaultLed | read-only | MCU fault LED color. |
| CAR phyMcuTempStatus | 1.3.6.1.4.1.8603.1.2.3.15.1.4 | CardTempStatus | read-only | MCU temperature status. |
| CAR phyMcuVoltageStatus | 1.3.6.1.4.1.8603.1.2.3.15.1.5 | CardVoltageStatus | read-only | MCU voltage status. |
| STR phyMcuSerialNumber | 1.3.6.1.4.1.8603.1.2.3.15.1.6 | DisplayString | read-only | MCU serial number. |
| STR phyMcuProductionDate | 1.3.6.1.4.1.8603.1.2.3.15.1.7 | DisplayString | read-only | MCU production date. |
| STR phyMcuPartNumber | 1.3.6.1.4.1.8603.1.2.3.15.1.8 | DisplayString | read-only | MCU part number. |
| STR phyMcuDescription | 1.3.6.1.4.1.8603.1.2.3.15.1.9 | DisplayString | read-only | MCU description. |
| STR phyMcuHardwareVersion | 1.3.6.1.4.1.8603.1.2.3.15.1.10 | DisplayString | read-only | MCU hardware version. |
| STR phyMcuIpmiSwVersion | 1.3.6.1.4.1.8603.1.2.3.15.1.11 | DisplayString | read-only | MCU IPMI software version. |
| STR phyMcuAssemblyId | 1.3.6.1.4.1.8603.1.2.3.15.1.12 | DisplayString | read-only | MCU assembly ID. |
| ASS phyMcuAssemblyIdSrc | 1.3.6.1.4.1.8603.1.2.3.15.1.13 | AssemblyIdSource | read-only | MCU assembly ID source. |
| T/F phyMcuExcessiveFakeAid | 1.3.6.1.4.1.8603.1.2.3.15.1.14 | TruthValue | read-only | This object is true if the assembly ID is programmed under more than one source. |
| ADM phyMcuAdminState | 1.3.6.1.4.1.8603.1.2.3.15.1.20 | AdminState | read-write | MCU administrative state. |
| STR phyCpldVersion | 1.3.6.1.4.1.8603.1.2.3.15.1.21 | DisplayString | read-only | MCU CPLD version. |
| phyBbuTable | 1.3.6.1.4.1.8603.1.2.3.16 | not-accessible | ||
| phyBbuEntry | 1.3.6.1.4.1.8603.1.2.3.16.1 | not-accessible | ||
| INT phyBbuIndex | 1.3.6.1.4.1.8603.1.2.3.16.1.1 | INTEGER | read-only | BBU index. |
| CAR phyBbuOpState | 1.3.6.1.4.1.8603.1.2.3.16.1.2 | CardOpState | read-only | BBU operational state. |
| CAR phyBbuFaultLed | 1.3.6.1.4.1.8603.1.2.3.16.1.3 | CardFaultLed | read-only | BBU fault LED color. |
| CAR phyBbuTempStatus | 1.3.6.1.4.1.8603.1.2.3.16.1.4 | CardTempStatus | read-only | BBU temperature status. |
| CAR phyBbuVoltageStatus | 1.3.6.1.4.1.8603.1.2.3.16.1.5 | CardVoltageStatus | read-only | BBU voltage status. |
| STR phyBbuSerialNumber | 1.3.6.1.4.1.8603.1.2.3.16.1.6 | DisplayString | read-only | BBU serial number. |
| STR phyBbuProductionDate | 1.3.6.1.4.1.8603.1.2.3.16.1.7 | DisplayString | read-only | BBU production date. |
| STR phyBbuPartNumber | 1.3.6.1.4.1.8603.1.2.3.16.1.8 | DisplayString | read-only | BBU part number. |
| STR phyBbuDescription | 1.3.6.1.4.1.8603.1.2.3.16.1.9 | DisplayString | read-only | BBU description. |
| STR phyBbuHardwareVersion | 1.3.6.1.4.1.8603.1.2.3.16.1.10 | DisplayString | read-only | BBU hardware version. |
| STR phyBbuIpmiSwVersion | 1.3.6.1.4.1.8603.1.2.3.16.1.11 | DisplayString | read-only | BBU IPMI software version. |
| STR phyBbuAssemblyId | 1.3.6.1.4.1.8603.1.2.3.16.1.12 | DisplayString | read-only | BBU assembly Id. |
| ASS phyBbuAssemblyIdSrc | 1.3.6.1.4.1.8603.1.2.3.16.1.13 | AssemblyIdSource | read-only | BBU assembly Id source. |
| T/F phyBbuExcessiveFakeAid | 1.3.6.1.4.1.8603.1.2.3.16.1.14 | TruthValue | read-only | This object is true if the assembly ID is programmed under more than one source. |
| ADM phyBbuAdminState | 1.3.6.1.4.1.8603.1.2.3.16.1.20 | AdminState | read-write | BBU administrative state. |
| phyRxuTable | 1.3.6.1.4.1.8603.1.2.3.17 | not-accessible | ||
| phyRxuEntry | 1.3.6.1.4.1.8603.1.2.3.17.1 | not-accessible | ||
| INT phyRxuIndex | 1.3.6.1.4.1.8603.1.2.3.17.1.1 | INTEGER | read-only | RXU index. |
| CAR phyRxuOpState | 1.3.6.1.4.1.8603.1.2.3.17.1.2 | CardOpState | read-only | RXU operational state. |
| CAR phyRxuFaultLed | 1.3.6.1.4.1.8603.1.2.3.17.1.3 | CardFaultLed | read-only | RXU fault LED color. |
| CAR phyRxuTempStatus | 1.3.6.1.4.1.8603.1.2.3.17.1.4 | CardTempStatus | read-only | RXU temperature status. |
| CAR phyRxuVoltageStatus | 1.3.6.1.4.1.8603.1.2.3.17.1.5 | CardVoltageStatus | read-only | RXU voltage status. |
| STR phyRxuSerialNumber | 1.3.6.1.4.1.8603.1.2.3.17.1.6 | DisplayString | read-only | RXU serial number. |
| STR phyRxuProductionDate | 1.3.6.1.4.1.8603.1.2.3.17.1.7 | DisplayString | read-only | RXU production date. |
| STR phyRxuPartNumber | 1.3.6.1.4.1.8603.1.2.3.17.1.8 | DisplayString | read-only | RXU part number. |
| STR phyRxuDescription | 1.3.6.1.4.1.8603.1.2.3.17.1.9 | DisplayString | read-only | RXU description. |
| STR phyRxuHardwareVersion | 1.3.6.1.4.1.8603.1.2.3.17.1.10 | DisplayString | read-only | RXU hardware version. |
| STR phyRxuIpmiSwVersion | 1.3.6.1.4.1.8603.1.2.3.17.1.11 | DisplayString | read-only | RXU IPMI software version. |
| STR phyRxuAssemblyId | 1.3.6.1.4.1.8603.1.2.3.17.1.12 | DisplayString | read-only | RXU assembly ID. |
| ASS phyRxuAssemblyIdSrc | 1.3.6.1.4.1.8603.1.2.3.17.1.13 | AssemblyIdSource | read-only | RXU assembly ID source. |
| T/F phyRxuExcessiveFakeAid | 1.3.6.1.4.1.8603.1.2.3.17.1.14 | TruthValue | read-only | This object is true if the assembly ID is programmed under more than one source. |
| ADM phyRxuAdminState | 1.3.6.1.4.1.8603.1.2.3.17.1.20 | AdminState | read-write | RXU administrative state. |
| RFB phyRxuRfBand | 1.3.6.1.4.1.8603.1.2.3.17.1.21 | RfBand | read-only | RXU RF band. |
| phyTxuTable | 1.3.6.1.4.1.8603.1.2.3.18 | not-accessible | ||
| phyTxuEntry | 1.3.6.1.4.1.8603.1.2.3.18.1 | not-accessible | ||
| INT phyTxuIndex | 1.3.6.1.4.1.8603.1.2.3.18.1.1 | INTEGER | read-only | TXU index. |
| CAR phyTxuOpState | 1.3.6.1.4.1.8603.1.2.3.18.1.2 | CardOpState | read-only | TXU operational state. |
| CAR phyTxuFaultLed | 1.3.6.1.4.1.8603.1.2.3.18.1.3 | CardFaultLed | read-only | TXU fault LED color. |
| CAR phyTxuTempStatus | 1.3.6.1.4.1.8603.1.2.3.18.1.4 | CardTempStatus | read-only | TXU temperature status. |
| CAR phyTxuVoltageStatus | 1.3.6.1.4.1.8603.1.2.3.18.1.5 | CardVoltageStatus | read-only | TXU voltage status. |
| STR phyTxuSerialNumber | 1.3.6.1.4.1.8603.1.2.3.18.1.6 | DisplayString | read-only | TXU serial number. |
| STR phyTxuProductionDate | 1.3.6.1.4.1.8603.1.2.3.18.1.7 | DisplayString | read-only | TXU production date. |
| STR phyTxuPartNumber | 1.3.6.1.4.1.8603.1.2.3.18.1.8 | DisplayString | read-only | TXU part number. |
| STR phyTxuDescription | 1.3.6.1.4.1.8603.1.2.3.18.1.9 | DisplayString | read-only | TXU description. |
| STR phyTxuHardwareVersion | 1.3.6.1.4.1.8603.1.2.3.18.1.10 | DisplayString | read-only | TXU hardware version. |
| STR phyTxuIpmiSwVersion | 1.3.6.1.4.1.8603.1.2.3.18.1.11 | DisplayString | read-only | TXU IPMI software version. |
| STR phyTxuAssemblyId | 1.3.6.1.4.1.8603.1.2.3.18.1.12 | DisplayString | read-only | TXU assembly ID. |
| ASS phyTxuAssemblyIdSrc | 1.3.6.1.4.1.8603.1.2.3.18.1.13 | AssemblyIdSource | read-only | TXU assembly ID source. |
| T/F phyTxuExcessiveFakeAid | 1.3.6.1.4.1.8603.1.2.3.18.1.14 | TruthValue | read-only | This object is true if the assembly ID is programmed under more than one source. |
| ADM phyTxuAdminState | 1.3.6.1.4.1.8603.1.2.3.18.1.20 | AdminState | read-write | TXU administrative state. |
| RFB phyTxuRfBand | 1.3.6.1.4.1.8603.1.2.3.18.1.21 | RfBand | read-only | TXU RF band. |
| rrPaShelf | 1.3.6.1.4.1.8603.1.2.4 | |||
| paTable | 1.3.6.1.4.1.8603.1.2.4.1 | not-accessible | ||
| paEntry | 1.3.6.1.4.1.8603.1.2.4.1.1 | not-accessible | ||
| INT paIndex | 1.3.6.1.4.1.8603.1.2.4.1.1.1 | INTEGER | read-only | Power Amp index. |
| ADM paAdminState | 1.3.6.1.4.1.8603.1.2.4.1.1.2 | AdminState | read-write | PA administrative state. |
| CAR paOpState | 1.3.6.1.4.1.8603.1.2.4.1.1.3 | CardOpState | read-only | PA operational state. This object is deprecated in favor of paOperStatus. |
| CAR paTempStatus | 1.3.6.1.4.1.8603.1.2.4.1.1.4 | CardTempStatus | read-only | PA temperature status. |
| STR paOutputTxPower | 1.3.6.1.4.1.8603.1.2.4.1.1.5 | FloatAsString | read-only | PA output transmit power, in dbm. |
| STR paInputTxPower | 1.3.6.1.4.1.8603.1.2.4.1.1.6 | FloatAsString | read-only | PA input transmit power, in dbm. |
| STR paTxReflectedPower | 1.3.6.1.4.1.8603.1.2.4.1.1.7 | FloatAsString | read-only | PA transmit reflected power, in dbm. |
| T/F paDcPowerFault | 1.3.6.1.4.1.8603.1.2.4.1.1.8 | TruthValue | read-only | This object indicates if a PA DC power fault exists. |
| T/F paRfOverdriveFault | 1.3.6.1.4.1.8603.1.2.4.1.1.9 | TruthValue | read-only | This object indicates if a PA RF overdrive fault exists. |
| T/F paFeedForwardFault | 1.3.6.1.4.1.8603.1.2.4.1.1.10 | TruthValue | read-only | This object indicates if a PA feed forward fault exists. |
| STR paSerialNumber | 1.3.6.1.4.1.8603.1.2.4.1.1.11 | DisplayString | read-only | PA serial number. |
| RFB paRfBand | 1.3.6.1.4.1.8603.1.2.4.1.1.12 | RfBand | read-only | PA RF band. This object is deprecated in favor of paRadioFreqBand. |
| STR paHardwareVersion | 1.3.6.1.4.1.8603.1.2.4.1.1.13 | DisplayString | read-only | PA hardware version. |
| INT paTemperatureEx | 1.3.6.1.4.1.8603.1.2.4.1.1.14 | INTEGER | read-only | PA temperature (Celcius). |
| T/F paReflectedPowerFault | 1.3.6.1.4.1.8603.1.2.4.1.1.15 | TruthValue | read-only | This object indicates if a reflected power fault exists. |
| T/F paUnderPowerFault | 1.3.6.1.4.1.8603.1.2.4.1.1.16 | TruthValue | read-only | This object indicates if an under power fault exists. |
| STR paTargetOutputTxPower | 1.3.6.1.4.1.8603.1.2.4.1.1.17 | FloatAsString | read-write | PA target output Tx power. |
| PAS paOperStatus | 1.3.6.1.4.1.8603.1.2.4.1.1.18 | PaState | read-only | PA operational state. |
| PAR paRadioFreqBand | 1.3.6.1.4.1.8603.1.2.4.1.1.19 | PaRfBand | read-only | PA RF band. |
| T/F paFanSpeedOk | 1.3.6.1.4.1.8603.1.2.4.2 | TruthValue | read-only | This object indicates if the PA shelf fan speed is within normal operating limits. |
| T/F paFanTempOk | 1.3.6.1.4.1.8603.1.2.4.3 | TruthValue | read-only | This object indicates if the PA shelf fan temperature is within normal operating limits. |
| T/F paBreakerTripped | 1.3.6.1.4.1.8603.1.2.4.4 | TruthValue | read-only | This object indicates if a PA shelf breaker has been tripped. |
| T/F paSimulcast | 1.3.6.1.4.1.8603.1.2.4.5 | TruthValue | read-write | This object indicates if the PA shelf supports simulcast. |
| T/F paTxCalEnabled | 1.3.6.1.4.1.8603.1.2.4.6 | TruthValue | read-write | This object indicates if PX Gain control loop is enabled. |
| paPowerTable | 1.3.6.1.4.1.8603.1.2.4.7 | not-accessible | This table is used to display PA various Tx power values. These values are store on the system as floating point numbers, but since SNMP cannot display floating point numbers, this table will convert the values to integer. | |
| paPowerEntry | 1.3.6.1.4.1.8603.1.2.4.7.1 | not-accessible | ||
| INT paPowerIndex | 1.3.6.1.4.1.8603.1.2.4.7.1.1 | INTEGER | read-only | PA index. |
| INT paPowerTxOutput | 1.3.6.1.4.1.8603.1.2.4.7.1.2 | INTEGER | read-only | PA output Tx power. In order to retain precision in converting the floating point value into integer, the value is first multiplied by 100. For example 43.25dB will be represented as 4325. |
| INT paPowerTxInput | 1.3.6.1.4.1.8603.1.2.4.7.1.3 | INTEGER | read-only | PA input Tx power. In order to retain precision in converting the floating point value into integer, the value is first multiplied by 100. For example -50.75dB will be represented as -5075. |
| INT paPowerTxReflected | 1.3.6.1.4.1.8603.1.2.4.7.1.4 | INTEGER | read-only | PA reflected Tx power. In order to retain precision in converting the floating point value into integer, the value is first multiplied by 100. For example 21.00dB will be represented as 2100. |
RFC description
Monitors physical chassis components, power modules, fans, and environmental status on Flarion wireless systems.
Start monitoring Flarion (Qualcomm) Flash-OFDM base-station chassis (hardware inventory/fans) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.