-- $Id: FLARION-PHYS-MIB.txt,v 1.5 2004/07/14 20:29:51 csmith Exp $ FLARION-PHYS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, IpAddress, TimeTicks, Unsigned32, Counter32 FROM SNMPv2-SMI enterprises FROM RFC1155-SMI DisplayString, RowStatus, DateAndTime, TruthValue FROM SNMPv2-TC AdminState, MoType, rrMib, rrManagedObjs, FloatAsString, rrBaseBandUnit FROM FLARION-MIB; rrPhyShelf OBJECT IDENTIFIER ::= { rrMib 3 } rrPaShelf OBJECT IDENTIFIER ::= { rrMib 4 } rrChassis OBJECT IDENTIFIER ::= { rrManagedObjs 8 } -- chassis type ChassisType ::= INTEGER { chassisUnknown(0), chassisCpciIndoor(1), chassisCpciOutdoor(2), chassisEnetIndoor(3), chassisEnetOutdoor(4) } -- Relay state RelayState ::= INTEGER { relayUnknown(0), relayOpen(1), relayClosed(2) } -- Card operational state CardOpState ::= INTEGER { cardOpStateUnknown(0), cardOpStateNotPresent(1), cardOpStateStandby(2), cardOpStateActive(3), cardOpStateDown(4) } -- Card fault LED colors CardFaultLed ::= INTEGER { faultLedUnknown(0), faultLedRed(1), faultLedOrange(2), faultLedGreen(3) } -- Card temperature status CardTempStatus ::= INTEGER { tempUnknown(0), tempNominal(1), tempHigh(2), tempSevere(3), tempCritical(4) } -- Card voltage status CardVoltageStatus ::= INTEGER { voltageUnknown(0), voltageNominal(1), voltageLow(2), voltageHigh(3) } -- RF band RfBand ::= INTEGER { rfBandUnknown(0), rfBandUpper700MHz(1), rfBandLow800MHz(2), rfBandCellBand(3), rfBandSmrBand(4), rfBandPcsKorea(5), rfBandPcsUs(6), rfBandUmts(7), rfBand2P3GHz(8), rfBandMmds(9) } -- PowerAmp RF band PaRfBand ::= INTEGER { paRfBandUnknown(0), paRfBand747to770MHz(1), paRfBand861to894MHz(2), paRfBand1930to1990MHz(3), paRfBand2370to2400MHz(4), paRfBand2110to2170MHz(5), paRfBand2620to2686MHz(6), paRfBand740Mto746Hz(7) } -- PowerAmp Operational State PaState ::= INTEGER { paStateUnknown(0), paStateProbing(1), paStateNotPresent(2), paStateDisabledByPa(3), paStateDisabledByBts(4), paStateEnabling(5), paStateEnabled(6), paStateDisabling(7) } -- Assembly Id source AssemblyIdSource ::= INTEGER { aidSourceUnknown(0), aidSourceDatabase(1), aidSourceTarget(2) } -- -- Chassis -- rrChassisType OBJECT-TYPE SYNTAX ChassisType MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The chassis revision." ::= { rrChassis 1 } rrChassisRev OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The chassis revision." ::= { rrChassis 2 } rrChassisMaxSlots OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Maximum number of slots in the chassis." ::= { rrChassis 3 } rrChassisNumCards OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Number of cards detected in the chassis." ::= { rrChassis 4 } rrChassisTable OBJECT-TYPE SYNTAX SEQUENCE OF RrChassisTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table containing chassis card information." ::= { rrChassis 5 } rrChassisTableEntry OBJECT-TYPE SYNTAX RrChassisTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RadioRouter chassis card table entry." INDEX { rrChassisSlotId } ::= { rrChassisTable 1 } RrChassisTableEntry ::= SEQUENCE { rrChassisSlotId INTEGER, rrChassisSlotHwType MoType, rrChassisSlotHwName DisplayString, rrChassisSlotHwStatus CardOpState, rrChassisSlotHwVer DisplayString, rrChassisSlotHwEsn OCTET STRING, rrChassisSlotSwVer DisplayString } rrChassisSlotId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The chassis slot of the card." ::= { rrChassisTableEntry 1 } rrChassisSlotHwType OBJECT-TYPE SYNTAX MoType MAX-ACCESS read-only STATUS current DESCRIPTION "The card type." ::= { rrChassisTableEntry 2 } rrChassisSlotHwName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The card name." ::= { rrChassisTableEntry 3 } rrChassisSlotHwStatus OBJECT-TYPE SYNTAX CardOpState MAX-ACCESS read-only STATUS current DESCRIPTION "The card hardware operational status." ::= { rrChassisTableEntry 4 } rrChassisSlotHwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The card hardware version number." ::= { rrChassisTableEntry 5 } rrChassisSlotHwEsn OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The card Electronic Serial Number." ::= { rrChassisTableEntry 6 } rrChassisSlotSwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The card IPMI (Intelligent Platform Management Interface) firmware version number." ::= { rrChassisTableEntry 8 } -- -- Physical Layout -- phyChassisType OBJECT-TYPE SYNTAX ChassisType MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis type." ::= { rrPhyShelf 1 } phySerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis serial number." ::= { rrPhyShelf 2 } phyProductionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis production date (mm/dd/yyyy)." ::= { rrPhyShelf 3 } phyPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis part number." ::= { rrPhyShelf 4 } phyHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis hardware version." ::= { rrPhyShelf 5 } phyChassisRfBand OBJECT-TYPE SYNTAX RfBand MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis RF band." ::= { rrPhyShelf 6 } phyAssemblyId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis assembly ID." ::= { rrPhyShelf 7 } -- -- Fan Table -- phyFanTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 10 } phyFanEntry OBJECT-TYPE SYNTAX PhyFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyFanIndex } ::= { phyFanTable 1 } PhyFanEntry ::= SEQUENCE { phyFanIndex INTEGER, phyFanOk TruthValue } phyFanIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Fan index." ::= { phyFanEntry 1 } phyFanOk OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Fan status." ::= { phyFanEntry 2 } -- -- Relay Table -- phyRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 11 } phyRelayEntry OBJECT-TYPE SYNTAX PhyRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyRelayIndex } ::= { phyRelayTable 1 } PhyRelayEntry ::= SEQUENCE { phyRelayIndex INTEGER, phyRelayName DisplayString, phyRelayState RelayState } phyRelayIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Relay index." ::= { phyRelayEntry 1 } phyRelayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Relay name." ::= { phyRelayEntry 2 } phyRelayState OBJECT-TYPE SYNTAX RelayState MAX-ACCESS read-only STATUS current DESCRIPTION "Relay state." ::= { phyRelayEntry 3 } -- -- Alarm Input Table -- phyAlarmInputTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyAlarmInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 12 } phyAlarmInputEntry OBJECT-TYPE SYNTAX PhyAlarmInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyAlarmInputIndex } ::= { phyAlarmInputTable 1 } PhyAlarmInputEntry ::= SEQUENCE { phyAlarmInputIndex INTEGER, phyAlarmInputEnable TruthValue, phyAlarmInputName DisplayString, phyAlarmInputState TruthValue } phyAlarmInputIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "AlarmInput index." ::= { phyAlarmInputEntry 1 } phyAlarmInputEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "AlarmInput enable." ::= { phyAlarmInputEntry 2 } phyAlarmInputName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "AlarmInput name." ::= { phyAlarmInputEntry 3 } phyAlarmInputState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "AlarmInput state." ::= { phyAlarmInputEntry 4 } -- -- Power Controller Unit (PCU) Table -- phyPcuTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyPcuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 13 } phyPcuEntry OBJECT-TYPE SYNTAX PhyPcuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyPcuIndex } ::= { phyPcuTable 1 } PhyPcuEntry ::= SEQUENCE { phyPcuIndex INTEGER, phyPcuPowerFail TruthValue } phyPcuIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "PCU index." ::= { phyPcuEntry 1 } phyPcuPowerFail OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "PCU power fail." ::= { phyPcuEntry 2 } -- -- Alarm Interface Unit (AIU) Table -- phyAiuTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyAiuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 14 } phyAiuEntry OBJECT-TYPE SYNTAX PhyAiuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyAiuIndex } ::= { phyAiuTable 1 } PhyAiuEntry ::= SEQUENCE { phyAiuIndex INTEGER, phyAiuOpState CardOpState, phyAiuFaultLed CardFaultLed, phyAiuTempStatus CardTempStatus, phyAiuVoltageStatus CardVoltageStatus, phyAiuSerialNumber DisplayString, phyAiuProductionDate DisplayString, phyAiuPartNumber DisplayString, phyAiuDescription DisplayString, phyAiuHardwareVersion DisplayString, phyAiuIpmiSwVersion DisplayString, phyAiuAssemblyId DisplayString, phyAiuAssemblyIdSrc AssemblyIdSource, phyAiuExcessiveFakeAid TruthValue, phyAiuAdminState AdminState, phyAiuRebootRr TruthValue } phyAiuIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "AIU index." ::= { phyAiuEntry 1 } phyAiuOpState OBJECT-TYPE SYNTAX CardOpState MAX-ACCESS read-only STATUS current DESCRIPTION "AIU operational state." ::= { phyAiuEntry 2 } phyAiuFaultLed OBJECT-TYPE SYNTAX CardFaultLed MAX-ACCESS read-only STATUS current DESCRIPTION "AIU fault LED color." ::= { phyAiuEntry 3 } phyAiuTempStatus OBJECT-TYPE SYNTAX CardTempStatus MAX-ACCESS read-only STATUS current DESCRIPTION "AIU temperature status." ::= { phyAiuEntry 4 } phyAiuVoltageStatus OBJECT-TYPE SYNTAX CardVoltageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "AIU voltage status." ::= { phyAiuEntry 5 } phyAiuSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "AIU serial number." ::= { phyAiuEntry 6 } phyAiuProductionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "AIU production date." ::= { phyAiuEntry 7 } phyAiuPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "AIU part number." ::= { phyAiuEntry 8 } phyAiuDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "AIU description." ::= { phyAiuEntry 9 } phyAiuHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "AIU hardware version." ::= { phyAiuEntry 10 } phyAiuIpmiSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "AIU IPMI software version." ::= { phyAiuEntry 11 } phyAiuAssemblyId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "AIU assembly ID." ::= { phyAiuEntry 12 } phyAiuAssemblyIdSrc OBJECT-TYPE SYNTAX AssemblyIdSource MAX-ACCESS read-only STATUS current DESCRIPTION "AIU assembly ID source." ::= { phyAiuEntry 13 } phyAiuExcessiveFakeAid OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is true(1) if the assembly ID is programmed under more than one source." ::= { phyAiuEntry 14 } phyAiuAdminState OBJECT-TYPE SYNTAX AdminState MAX-ACCESS read-write STATUS current DESCRIPTION "AIU administrative state." ::= { phyAiuEntry 20 } phyAiuRebootRr OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to true(1) will power cycle the RadioRouter chassis!" ::= { phyAiuEntry 21 } -- -- Main Controller Unit (MCU) Table -- phyMcuTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyMcuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 15 } phyMcuEntry OBJECT-TYPE SYNTAX PhyMcuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyMcuIndex } ::= { phyMcuTable 1 } PhyMcuEntry ::= SEQUENCE { phyMcuIndex INTEGER, phyMcuOpState CardOpState, phyMcuFaultLed CardFaultLed, phyMcuTempStatus CardTempStatus, phyMcuVoltageStatus CardVoltageStatus, phyMcuSerialNumber DisplayString, phyMcuProductionDate DisplayString, phyMcuPartNumber DisplayString, phyMcuDescription DisplayString, phyMcuHardwareVersion DisplayString, phyMcuIpmiSwVersion DisplayString, phyMcuAssemblyId DisplayString, phyMcuAssemblyIdSrc AssemblyIdSource, phyMcuExcessiveFakeAid TruthValue, phyMcuAdminState AdminState, phyCpldVersion DisplayString } phyMcuIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "MCU index." ::= { phyMcuEntry 1 } phyMcuOpState OBJECT-TYPE SYNTAX CardOpState MAX-ACCESS read-only STATUS current DESCRIPTION "MCU operational state." ::= { phyMcuEntry 2 } phyMcuFaultLed OBJECT-TYPE SYNTAX CardFaultLed MAX-ACCESS read-only STATUS current DESCRIPTION "MCU fault LED color." ::= { phyMcuEntry 3 } phyMcuTempStatus OBJECT-TYPE SYNTAX CardTempStatus MAX-ACCESS read-only STATUS current DESCRIPTION "MCU temperature status." ::= { phyMcuEntry 4 } phyMcuVoltageStatus OBJECT-TYPE SYNTAX CardVoltageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "MCU voltage status." ::= { phyMcuEntry 5 } phyMcuSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MCU serial number." ::= { phyMcuEntry 6 } phyMcuProductionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MCU production date." ::= { phyMcuEntry 7 } phyMcuPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MCU part number." ::= { phyMcuEntry 8 } phyMcuDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MCU description." ::= { phyMcuEntry 9 } phyMcuHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MCU hardware version." ::= { phyMcuEntry 10 } phyMcuIpmiSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MCU IPMI software version." ::= { phyMcuEntry 11 } phyMcuAssemblyId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MCU assembly ID." ::= { phyMcuEntry 12 } phyMcuAssemblyIdSrc OBJECT-TYPE SYNTAX AssemblyIdSource MAX-ACCESS read-only STATUS current DESCRIPTION "MCU assembly ID source." ::= { phyMcuEntry 13 } phyMcuExcessiveFakeAid OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is true if the assembly ID is programmed under more than one source." ::= { phyMcuEntry 14 } phyMcuAdminState OBJECT-TYPE SYNTAX AdminState MAX-ACCESS read-write STATUS current DESCRIPTION "MCU administrative state." ::= { phyMcuEntry 20 } phyCpldVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MCU CPLD version." ::= { phyMcuEntry 21 } -- -- Base Band Unit (BBU) Table -- phyBbuTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyBbuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 16 } phyBbuEntry OBJECT-TYPE SYNTAX PhyBbuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyBbuIndex } ::= { phyBbuTable 1 } PhyBbuEntry ::= SEQUENCE { phyBbuIndex INTEGER, phyBbuOpState CardOpState, phyBbuFaultLed CardFaultLed, phyBbuTempStatus CardTempStatus, phyBbuVoltageStatus CardVoltageStatus, phyBbuSerialNumber DisplayString, phyBbuProductionDate DisplayString, phyBbuPartNumber DisplayString, phyBbuDescription DisplayString, phyBbuHardwareVersion DisplayString, phyBbuIpmiSwVersion DisplayString, phyBbuAssemblyId DisplayString, phyBbuAssemblyIdSrc AssemblyIdSource, phyBbuExcessiveFakeAid TruthValue, phyBbuAdminState AdminState } phyBbuIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "BBU index." ::= { phyBbuEntry 1 } phyBbuOpState OBJECT-TYPE SYNTAX CardOpState MAX-ACCESS read-only STATUS current DESCRIPTION "BBU operational state." ::= { phyBbuEntry 2 } phyBbuFaultLed OBJECT-TYPE SYNTAX CardFaultLed MAX-ACCESS read-only STATUS current DESCRIPTION "BBU fault LED color." ::= { phyBbuEntry 3 } phyBbuTempStatus OBJECT-TYPE SYNTAX CardTempStatus MAX-ACCESS read-only STATUS current DESCRIPTION "BBU temperature status." ::= { phyBbuEntry 4 } phyBbuVoltageStatus OBJECT-TYPE SYNTAX CardVoltageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "BBU voltage status." ::= { phyBbuEntry 5 } phyBbuSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BBU serial number." ::= { phyBbuEntry 6 } phyBbuProductionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BBU production date." ::= { phyBbuEntry 7 } phyBbuPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BBU part number." ::= { phyBbuEntry 8 } phyBbuDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BBU description." ::= { phyBbuEntry 9 } phyBbuHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BBU hardware version." ::= { phyBbuEntry 10 } phyBbuIpmiSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BBU IPMI software version." ::= { phyBbuEntry 11 } phyBbuAssemblyId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BBU assembly Id." ::= { phyBbuEntry 12 } phyBbuAssemblyIdSrc OBJECT-TYPE SYNTAX AssemblyIdSource MAX-ACCESS read-only STATUS current DESCRIPTION "BBU assembly Id source." ::= { phyBbuEntry 13 } phyBbuExcessiveFakeAid OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is true if the assembly ID is programmed under more than one source." ::= { phyBbuEntry 14 } phyBbuAdminState OBJECT-TYPE SYNTAX AdminState MAX-ACCESS read-write STATUS current DESCRIPTION "BBU administrative state." ::= { phyBbuEntry 20 } -- -- RX Unit (RXU) Table -- phyRxuTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyRxuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 17 } phyRxuEntry OBJECT-TYPE SYNTAX PhyRxuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyRxuIndex } ::= { phyRxuTable 1 } PhyRxuEntry ::= SEQUENCE { phyRxuIndex INTEGER, phyRxuOpState CardOpState, phyRxuFaultLed CardFaultLed, phyRxuTempStatus CardTempStatus, phyRxuVoltageStatus CardVoltageStatus, phyRxuSerialNumber DisplayString, phyRxuProductionDate DisplayString, phyRxuPartNumber DisplayString, phyRxuDescription DisplayString, phyRxuHardwareVersion DisplayString, phyRxuIpmiSwVersion DisplayString, phyRxuAssemblyId DisplayString, phyRxuAssemblyIdSrc AssemblyIdSource, phyRxuExcessiveFakeAid TruthValue, phyRxuAdminState AdminState, phyRxuRfBand RfBand } phyRxuIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "RXU index." ::= { phyRxuEntry 1 } phyRxuOpState OBJECT-TYPE SYNTAX CardOpState MAX-ACCESS read-only STATUS current DESCRIPTION "RXU operational state." ::= { phyRxuEntry 2 } phyRxuFaultLed OBJECT-TYPE SYNTAX CardFaultLed MAX-ACCESS read-only STATUS current DESCRIPTION "RXU fault LED color." ::= { phyRxuEntry 3 } phyRxuTempStatus OBJECT-TYPE SYNTAX CardTempStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RXU temperature status." ::= { phyRxuEntry 4 } phyRxuVoltageStatus OBJECT-TYPE SYNTAX CardVoltageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RXU voltage status." ::= { phyRxuEntry 5 } phyRxuSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RXU serial number." ::= { phyRxuEntry 6 } phyRxuProductionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RXU production date." ::= { phyRxuEntry 7 } phyRxuPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RXU part number." ::= { phyRxuEntry 8 } phyRxuDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RXU description." ::= { phyRxuEntry 9 } phyRxuHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RXU hardware version." ::= { phyRxuEntry 10 } phyRxuIpmiSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RXU IPMI software version." ::= { phyRxuEntry 11 } phyRxuAssemblyId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RXU assembly ID." ::= { phyRxuEntry 12 } phyRxuAssemblyIdSrc OBJECT-TYPE SYNTAX AssemblyIdSource MAX-ACCESS read-only STATUS current DESCRIPTION "RXU assembly ID source." ::= { phyRxuEntry 13 } phyRxuExcessiveFakeAid OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is true if the assembly ID is programmed under more than one source." ::= { phyRxuEntry 14 } phyRxuAdminState OBJECT-TYPE SYNTAX AdminState MAX-ACCESS read-write STATUS current DESCRIPTION "RXU administrative state." ::= { phyRxuEntry 20 } phyRxuRfBand OBJECT-TYPE SYNTAX RfBand MAX-ACCESS read-only STATUS current DESCRIPTION "RXU RF band." ::= { phyRxuEntry 21 } -- -- TX Unit (TXU) Table -- phyTxuTable OBJECT-TYPE SYNTAX SEQUENCE OF PhyTxuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPhyShelf 18 } phyTxuEntry OBJECT-TYPE SYNTAX PhyTxuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { phyTxuIndex } ::= { phyTxuTable 1 } PhyTxuEntry ::= SEQUENCE { phyTxuIndex INTEGER, phyTxuOpState CardOpState, phyTxuFaultLed CardFaultLed, phyTxuTempStatus CardTempStatus, phyTxuVoltageStatus CardVoltageStatus, phyTxuSerialNumber DisplayString, phyTxuProductionDate DisplayString, phyTxuPartNumber DisplayString, phyTxuDescription DisplayString, phyTxuHardwareVersion DisplayString, phyTxuIpmiSwVersion DisplayString, phyTxuAssemblyId DisplayString, phyTxuAssemblyIdSrc AssemblyIdSource, phyTxuExcessiveFakeAid TruthValue, phyTxuAdminState AdminState, phyTxuRfBand RfBand } phyTxuIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "TXU index." ::= { phyTxuEntry 1 } phyTxuOpState OBJECT-TYPE SYNTAX CardOpState MAX-ACCESS read-only STATUS current DESCRIPTION "TXU operational state." ::= { phyTxuEntry 2 } phyTxuFaultLed OBJECT-TYPE SYNTAX CardFaultLed MAX-ACCESS read-only STATUS current DESCRIPTION "TXU fault LED color." ::= { phyTxuEntry 3 } phyTxuTempStatus OBJECT-TYPE SYNTAX CardTempStatus MAX-ACCESS read-only STATUS current DESCRIPTION "TXU temperature status." ::= { phyTxuEntry 4 } phyTxuVoltageStatus OBJECT-TYPE SYNTAX CardVoltageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "TXU voltage status." ::= { phyTxuEntry 5 } phyTxuSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TXU serial number." ::= { phyTxuEntry 6 } phyTxuProductionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TXU production date." ::= { phyTxuEntry 7 } phyTxuPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TXU part number." ::= { phyTxuEntry 8 } phyTxuDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TXU description." ::= { phyTxuEntry 9 } phyTxuHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TXU hardware version." ::= { phyTxuEntry 10 } phyTxuIpmiSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TXU IPMI software version." ::= { phyTxuEntry 11 } phyTxuAssemblyId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TXU assembly ID." ::= { phyTxuEntry 12 } phyTxuAssemblyIdSrc OBJECT-TYPE SYNTAX AssemblyIdSource MAX-ACCESS read-only STATUS current DESCRIPTION "TXU assembly ID source." ::= { phyTxuEntry 13 } phyTxuExcessiveFakeAid OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is true if the assembly ID is programmed under more than one source." ::= { phyTxuEntry 14 } phyTxuAdminState OBJECT-TYPE SYNTAX AdminState MAX-ACCESS read-write STATUS current DESCRIPTION "TXU administrative state." ::= { phyTxuEntry 20 } phyTxuRfBand OBJECT-TYPE SYNTAX RfBand MAX-ACCESS read-only STATUS current DESCRIPTION "TXU RF band." ::= { phyTxuEntry 21 } -- -- Power Amp -- paTable OBJECT-TYPE SYNTAX SEQUENCE OF PaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { rrPaShelf 1 } paEntry OBJECT-TYPE SYNTAX PaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { paIndex } ::= { paTable 1 } PaEntry ::= SEQUENCE { paIndex INTEGER, paAdminState AdminState, paOpState CardOpState, paTempStatus CardTempStatus, paOutputTxPower FloatAsString, paInputTxPower FloatAsString, paTxReflectedPower FloatAsString, paDcPowerFault TruthValue, paRfOverdriveFault TruthValue, paFeedForwardFault TruthValue, paSerialNumber DisplayString, paRfBand RfBand, paHardwareVersion DisplayString, paTemperature INTEGER, paReflectedPowerFault TruthValue, paUnderPowerFault TruthValue, paTargetOutputTxPower FloatAsString, paOperStatus PaState, paRadioFreqBand PaRfBand } paIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Power Amp index." ::= { paEntry 1 } paAdminState OBJECT-TYPE SYNTAX AdminState MAX-ACCESS read-write STATUS current DESCRIPTION "PA administrative state." ::= { paEntry 2 } paOpState OBJECT-TYPE SYNTAX CardOpState MAX-ACCESS read-only STATUS deprecated DESCRIPTION "PA operational state. This object is deprecated in favor of paOperStatus." ::= { paEntry 3 } paTempStatus OBJECT-TYPE SYNTAX CardTempStatus MAX-ACCESS read-only STATUS current DESCRIPTION "PA temperature status." ::= { paEntry 4 } paOutputTxPower OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-only STATUS current DESCRIPTION "PA output transmit power, in dbm." ::= { paEntry 5 } paInputTxPower OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-only STATUS current DESCRIPTION "PA input transmit power, in dbm." ::= { paEntry 6 } paTxReflectedPower OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-only STATUS current DESCRIPTION "PA transmit reflected power, in dbm." ::= { paEntry 7 } paDcPowerFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if a PA DC power fault exists." ::= { paEntry 8 } paRfOverdriveFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if a PA RF overdrive fault exists." ::= { paEntry 9 } paFeedForwardFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if a PA feed forward fault exists." ::= { paEntry 10 } paSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PA serial number." ::= { paEntry 11 } paRfBand OBJECT-TYPE SYNTAX RfBand MAX-ACCESS read-only STATUS deprecated DESCRIPTION "PA RF band. This object is deprecated in favor of paRadioFreqBand." ::= { paEntry 12 } paHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PA hardware version." ::= { paEntry 13 } paTemperature OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "PA temperature (Celcius)." ::= { paEntry 14 } paReflectedPowerFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if a reflected power fault exists." ::= { paEntry 15 } paUnderPowerFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if an under power fault exists." ::= { paEntry 16 } paTargetOutputTxPower OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-write STATUS current DESCRIPTION "PA target output Tx power." DEFVAL { "43.0" } ::= { paEntry 17 } paOperStatus OBJECT-TYPE SYNTAX PaState MAX-ACCESS read-only STATUS current DESCRIPTION "PA operational state." ::= { paEntry 18 } paRadioFreqBand OBJECT-TYPE SYNTAX PaRfBand MAX-ACCESS read-only STATUS current DESCRIPTION "PA RF band." ::= { paEntry 19 } paFanSpeedOk OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if the PA shelf fan speed is within normal operating limits." ::= { rrPaShelf 2 } paFanTempOk OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if the PA shelf fan temperature is within normal operating limits." ::= { rrPaShelf 3 } paBreakerTripped OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if a PA shelf breaker has been tripped." ::= { rrPaShelf 4 } paSimulcast OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if the PA shelf supports simulcast." DEFVAL { false } ::= { rrPaShelf 5 } paTxCalEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if PX Gain control loop is enabled." DEFVAL { true } ::= { rrPaShelf 6 } -- -- Power Amp Tx Power -- paPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF PaPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to display PA various Tx power values. These values are store on the system as floating point numbers, but since SNMP cannot display floating point numbers, this table will convert the values to integer." ::= { rrPaShelf 7 } paPowerEntry OBJECT-TYPE SYNTAX PaPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { paPowerIndex } ::= { paPowerTable 1 } PaPowerEntry ::= SEQUENCE { paPowerIndex INTEGER, paPowerTxOutput INTEGER, paPowerTxInput INTEGER, paPowerTxReflected INTEGER } paPowerIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "PA index." ::= { paPowerEntry 1 } paPowerTxOutput OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "PA output Tx power. In order to retain precision in converting the floating point value into integer, the value is first multiplied by 100. For example 43.25dB will be represented as 4325." ::= { paPowerEntry 2 } paPowerTxInput OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "PA input Tx power. In order to retain precision in converting the floating point value into integer, the value is first multiplied by 100. For example -50.75dB will be represented as -5075." ::= { paPowerEntry 3 } paPowerTxReflected OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "PA reflected Tx power. In order to retain precision in converting the floating point value into integer, the value is first multiplied by 100. For example 21.00dB will be represented as 2100." ::= { paPowerEntry 4 } -- -- BBU System Table -- bbuSysTable OBJECT-TYPE SYNTAX SEQUENCE OF BbuSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Base Band Unit system information." ::= { rrBaseBandUnit 5 } bbuSysEntry OBJECT-TYPE SYNTAX BbuSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Base Band Unit system table entry." INDEX { bbuSysId } ::= { bbuSysTable 1 } BbuSysEntry ::= SEQUENCE { bbuSysId INTEGER, bbuDspVer DisplayString, bbuLlcVer DisplayString, bbuTxFpgaVer DisplayString, bbuRxFpgaVer DisplayString, bbuLdpcVer Unsigned32, bbuRfChanNum INTEGER, bbuExtGainTx INTEGER, bbuExtGainRx INTEGER, bbuRfGainRx0 INTEGER, bbuRfGainRx1 INTEGER, bbuRfBand INTEGER, bbuRfPowerTx0 INTEGER, bbuRfPowerTx1 INTEGER, bbuRfuEnableMask INTEGER, bbuExtTxGain FloatAsString, bbuExtRxGain FloatAsString, bbuRfRx0Gain FloatAsString, bbuRfRx1Gain FloatAsString, bbuRfTx0Power FloatAsString, bbuRfTx1Power FloatAsString, bbuTxPwrDeviationLimit INTEGER, bbuSlope INTEGER, bbuMcastSnr INTEGER, bbuScmType INTEGER, bbuSleepInactivityTimer INTEGER, bbuLuTimer INTEGER } bbuSysId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This identifies a single BBU in a basestation." ::= { bbuSysEntry 1 } bbuDspVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The read-only statistic indicates the version number of the DSP software currently operational on the sector in question. It has the major.minor.micro notation." ::= { bbuSysEntry 2 } bbuLlcVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The read-only statistic indicates the version number of the Link List Controller software/firmware currently operational on the sector in question. It has the major.minor notation." ::= { bbuSysEntry 3 } bbuTxFpgaVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The read-only statistic indicates the version number of the Tx FPGA software/firmware currently operational on the sector in question. It has the major.minor notation." ::= { bbuSysEntry 4 } bbuRxFpgaVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The read-only statistic indicates the version number of the Rx FPGA software/firmware currently operational on the sector in question. It has the major.minor notation." ::= { bbuSysEntry 5 } bbuLdpcVer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The read-only statistic indicates the version number of the LDPC encoder/decoder software/firmware currently operational on the sector in question. It has the major.minor notation." ::= { bbuSysEntry 6 } bbuRfChanNum OBJECT-TYPE SYNTAX INTEGER (0..2000) MAX-ACCESS read-write STATUS current DESCRIPTION "The RF channel number, in conjunction with the bbuRffBand object defines the frequency of operation. The channel number follows well-known ITU numbering, and represents 50 kHz spacing. The step size depends on the band. In the 1.9 GHz band, the step size is 4 (200 kHz). Editable offline." DEFVAL { 295 } ::= { bbuSysEntry 50 } bbuExtGainTx OBJECT-TYPE SYNTAX INTEGER (-1600..2240) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Represents the total external gain in the Tx path. Typically it equals PA gain minus any attenuators. The value is in dB * 32 (scaled by 32). E.g., default value is 43 dB, which is the PA gain, and is represented as 43*32 = 1376. This parameter is used to assist the mobile in making an access attempt at an appropriate power level. The step size is 1 dB. Editable online." DEFVAL { 1376 } ::= { bbuSysEntry 51 } bbuExtGainRx OBJECT-TYPE SYNTAX INTEGER (-1600..2240) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Represents the total external gain in the Rx path. Typically it equals LNA gain minus any attenuators. The value is in dB * 32 (scaled by 32). E.g., default value is 31 dB, which is the LNA gain, and is represented as 31*32 = 992. This parameter is used to assist the mobile in making an access attempt at an appropriate power level. The step size is 1 dB. Editable online." DEFVAL { 992 } ::= { bbuSysEntry 52 } bbuRfGainRx0 OBJECT-TYPE SYNTAX INTEGER (-10..75) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Represents the gain (in dB) provided by the RF Rx blade(RXU) in the Rx0 path. This gain is in addition to the gain provided by the LNA. This value is typically calibrated and set in the factory. The step size is 1 dB. Editable online." DEFVAL { 42 } ::= { bbuSysEntry 53 } bbuRfGainRx1 OBJECT-TYPE SYNTAX INTEGER (-10..75) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Represents the gain (in dB) provided by the RF Rx blade(RXU) in the Rx1 path. This gain is in addition to the gain provided by the LNA. This value is typically calibrated and set in the factory. The step size is 1 dB. Editable online." DEFVAL { 42 } ::= { bbuSysEntry 54 } bbuRfBand OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The band of operation, represented by an enumeration. E.g., the 1.9 GHz PCS band has a value of 6, while the 2.1 GHz UMTS band has a value of 7. This quantity, in conjunction with the bbuRfChanNum decides the frequency of operation. Editable offline." DEFVAL { 0 } ::= { bbuSysEntry 55 } bbuRfPowerTx0 OBJECT-TYPE SYNTAX INTEGER (-20..10) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Represents the signal strength in dBm of the Tx signal put out on Tx0 by the TXU. An increase in this implies an increase in the signal input to the PA. Step size is 1 dBm. Editable online." DEFVAL { 0 } ::= { bbuSysEntry 56 } bbuRfPowerTx1 OBJECT-TYPE SYNTAX INTEGER (-20..10) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Represents the signal strength in dBm of the Tx signal put out on Tx1 by the TXU. An increase in this implies an increase in the signal input to the PA. Step size is 1 dBm. Editable online." DEFVAL { 0 } ::= { bbuSysEntry 57 } bbuRfuEnableMask OBJECT-TYPE SYNTAX INTEGER (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a bit mask to choose between the 0 and 1 channels for Rx and Tx. The value should be an OR of the channels selected, where: Tx0 = 0001 Tx1 = 0010 Rx0 = 0100 Rx1 = 1000 For example, set this object to 6 if Rx0 and Tx1 need to be enabled." DEFVAL { 15 } ::= { bbuSysEntry 59 } bbuExtTxGain OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-write STATUS current DESCRIPTION "External Tx gain. Valid range is -50.0 to 70.0." DEFVAL { "43.0" } ::= { bbuSysEntry 60 } bbuExtRxGain OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-write STATUS current DESCRIPTION "External Rx gain. Valid range is -50.0 to 70.0." DEFVAL { "31.0" } ::= { bbuSysEntry 61 } bbuRfRx0Gain OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-write STATUS current DESCRIPTION "Represents the gain (in dB) provided by the RF Rx blade(RXU) in the Rx0 path. This gain is in addition to the gain provided by the LNA. This value is typically calibrated and set in the factory. The step size is 1 dB. Valid range is -10.0 to 75.0. Editable online." DEFVAL { "42" } ::= { bbuSysEntry 62 } bbuRfRx1Gain OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-write STATUS current DESCRIPTION "Represents the gain (in dB) provided by the RF Rx blade(RXU) in the Rx1 path. This gain is in addition to the gain provided by the LNA. This value is typically calibrated and set in the factory. The step size is 1 dB. Valid range is -10.0 to 75.0. Editable online." DEFVAL { "42" } ::= { bbuSysEntry 63 } bbuRfTx0Power OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-write STATUS current DESCRIPTION "Represents the signal strength in dBm of the Tx signal put out on Tx0 by the TXU. An increase in this implies an increase in the signal input to the PA. Step size is 1 dBm. Valid range is -20.0 to 10.0. Editable online." DEFVAL { "0" } ::= { bbuSysEntry 64 } bbuRfTx1Power OBJECT-TYPE SYNTAX FloatAsString MAX-ACCESS read-write STATUS current DESCRIPTION "Represents the signal strength in dBm of the Tx signal put out on Tx1 by the TXU. An increase in this implies an increase in the signal input to the PA. Step size is 1 dBm. Valid range is -20.0 to 10.0. Editable online." DEFVAL { "0" } ::= { bbuSysEntry 65 } bbuTxPwrDeviationLimit OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "" DEFVAL { 2 } ::= { bbuSysEntry 66 } bbuSlope OBJECT-TYPE SYNTAX INTEGER (1..112) MAX-ACCESS read-write STATUS current DESCRIPTION "Represents the slope of the RR sector. It is an identifier which allows a mobile to distinguish between signals from different basestations. There are 112 possible slope values, however, only 80 of these are considered valid values. Editable offline." DEFVAL { 10 } ::= { bbuSysEntry 70 } bbuMcastSnr OBJECT-TYPE SYNTAX INTEGER (-20..35) MAX-ACCESS read-write STATUS current DESCRIPTION "" DEFVAL { 8 } ::= { bbuSysEntry 71 } bbuScmType OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "" DEFVAL { 1 } ::= { bbuSysEntry 72 } bbuSleepInactivityTimer OBJECT-TYPE SYNTAX INTEGER (0..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Represents the amount of time of data inactivity (on the forward or reverse links) after which a mobile moves to the Sleep state. In units of 1/3 seconds [ eg. Value = 180 represents 60 seconds]. This time period is conveyed to the mobile at the time of establishing connectivity with the basestation. This quantity is non-linearly quantized, so the actual duration of inactivity before sleep may be slightly different from this value. Step size is 1/3 second. Range is 0 to 20 minutes. 0 means never go to sleep. Recommended value is 180 (i.e., 60sec). Editable online." DEFVAL { 0 } ::= { bbuSysEntry 91 } bbuLuTimer OBJECT-TYPE SYNTAX INTEGER (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Periodicity, in seconds, of location update done by a stationary mobile. This time period is conveyed to the mobile at the time of establishing connectivity with the RR. This quantity is non-linearly quantized, so the actual duration of location update may be slightly different from this value. Step size is 1 second. Range is 5 seconds to 18 hours. Editable online." DEFVAL { 900 } ::= { bbuSysEntry 100 } END