ENTERASYS-SNTP-CLIENT-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ENTERASYS-SNTP-CLIENT-MIB

Organization: Enterasys Networks, Inc

Last Updated: 2003-11-06

Category: Protocol: SNTP/NTP, Vendor: Enterasys/Cabletron

Description: Enterasys Networks SNTP client MIB for configuring SNTP server addresses, operating mode, and time synchronization statistics.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ENTERASYS-SNTP-CLIENT-MIB?

ENTERASYS-SNTP-CLIENT-MIB is an Enterasys Networks vendor MIB, under the etsysModules enterprise branch, for configuring and monitoring the Simple Network Time Protocol client on Enterasys switches. It defines textual conventions for the supported operating modes (SntpClientOperModes: disabled/unicast/multicast/broadcast/anycast) and per-request outcome status (SntpClientUpdateStatus: success, requestTimedOut, badDateEncoded, versionNotSupported, serverUnsychronized), and organizes configuration/statistics under separate unicast, multicast, broadcast, and anycast branches, with etsysSntpClientUServerTable holding per-configured-server unicast settings and results. This exposes whether the device is successfully synchronizing its clock via SNTP and, if not, the specific failure reason, which matters since accurate device time underpins log correlation and certificate validation. It depends on the device's chosen SNTP operating mode configuration and complements standard time-related MIBs. It is deployed on Enterasys Networks switches wherever SNTP client synchronization is enabled, and network engineers reference the ENTERASYS-SNTP-CLIENT-MIB MIB when polling these clock-sync objects.

IPNetwork Monitor allows you to monitor SNMP objects defined in ENTERASYS-SNTP-CLIENT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Enterasys (Extreme Networks) switches

Monitoring Examples

An operator polls the update-status object for entries in etsysSntpClientUServerTable to check whether recent SNTP requests to a configured server returned success; a server consistently reporting requestTimedOut or serverUnsychronized would indicate an unreachable or unsynchronized time source, risking clock drift on the switch.

What Can Be Monitored

  • SNTP client operating mode (unicast/multicast/broadcast/anycast)
  • per-server unicast SNTP configuration and last update status
  • SNTP request success/failure reason codes
  • clock synchronization status
Imported Objects

From ENTERASYS-MIB-NAMES

etsysModulesOBJECT-IDENTITY

From INET-ADDRESS-MIB

InetAddress
InetAddressType

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Counter32
Gauge32
MODULE-IDENTITY
OBJECT-TYPE
Unsigned32

From SNMPv2-TC

DateAndTime
RowStatus
TEXTUAL-CONVENTION

How to Use in IPNetwork Monitor

Example using etsysSntpClientMulticastCount OID:

Select an Enterasys (Extreme Networks) switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type etsysSntpClientMulticastCount into the Find box to locate it in the OID tree, then select it and click OK. The number of unsolicited multicast SNTP messages that have been received and processed by the SNTP client. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Configures SNTP client mode (unicast, multicast, broadcast) and collects time synchronization statistics on Enterasys network equipment.

Start monitoring Enterasys (Extreme Networks) switches with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download ENTERASYS-SNTP-CLIENT-MIB