Organization: Gude Analog- und Digitalsysteme GmbH

Last Updated: 2007-03-05

Category: Domain: Power/UPS, Vendor: Gude

Description: Gude EPC2X6 MIB for managing 6-outlet power controller with environmental sensor monitoring capabilities.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is GUDEADS-EPC2X6-MIB?

GUDEADS-EPC2X6-MIB is a Gude vendor MIB for the EPC2X6 series, a compact 6-outlet IP-controllable power distribution unit with environmental sensor support. It exposes per-outlet fuse and power status, an onboard environmental temperature reading, SNMP trap destination configuration, and SNMP access control settings. It is a direct hardware status/environmental monitoring MIB: epc2x6Temperature reports ambient or unit temperature for overheating detection, epc2x6portFuses reveals a blown fuse on an outlet branch, and per-outlet state in epc2x6portTable shows whether each connected device is powered. No specific external MIB dependency is evident beyond standard SNMP enterprise conventions under the Gude (gadsEPC2x6) branch, though it configures its own trap destinations independent of the standard SNMP-TARGET-MIB. It is deployed in small network closets, racks, or remote sites needing compact remote power switching with basic environmental monitoring. Engineers can download the GUDEADS-EPC2X6-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in GUDEADS-EPC2X6-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Gude EPC2X6 6-outlet IP power distribution unit with environmental sensor

Monitoring Examples

An administrator would poll epc2x6Temperature to catch a rising ambient temperature in an enclosure before it causes equipment stress, and check epc2x6portFuses to confirm none of the outlet fuses have blown. Walking epc2x6portTable/epc2x6portEntry (indexed by epc2x6PortIndex) surfaces epc2x6PortName and each outlet's power state, letting staff remotely verify or toggle power to a specific device. epc2x6TrapIPTable (indexed by epc2x6TrapIPIndex, with epc2x6TrapIPPort) would be configured to direct alarm traps, such as a fuse trip or high temperature, to a specific management station.

What Can Be Monitored

  • ambient/unit temperature
  • outlet fuse status
  • per-outlet power state
  • per-outlet name/identity
  • trap destination configuration
Imported Objects

From SNMPv2-CONF

NOTIFICATION-GROUP
OBJECT-GROUP

From SNMPv2-SMI

Counter32
Integer32
IpAddress
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
enterprises

How to Use in IPNetwork Monitor

Example using epc2x6PortSwitchCount OID:

Select a Gude EPC2X6 6-outlet IP power distribution unit (with environmental sensor) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type epc2x6PortSwitchCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of switch actions ocurred on a PowerPort. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Monitors power management and environmental parameters for Gude EPC2x6 power distribution units including temperature and fuse status.

Start monitoring Gude EPC2X6 6-outlet IP power distribution unit (with environmental sensor) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download GUDEADS-EPC2X6-MIB