DKSF-202-9-X-X-1

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsDKSF-202-9-X-X-1

Organization: Alentis Electronics

Last Updated: 2015-08-17

Category: Domain: Environmental Monitoring, Vendor: NetPing/DKSF

Description: MIB for DKSF-202 NetPing device firmware 9.x providing remote environmental monitoring and I/O control objects.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is DKSF-202-9-X-X-1?

DKSF-202-9-X-X-1 is the vendor MIB for the NetPing DKSF-202 device, a compact remote environmental-monitoring and I/O-control appliance running firmware version 9.x from NetPing, used for monitoring physical conditions and controlling relay outputs at remote sites. It exposes environmental/relay control data including relay channel state and configuration (npRelayTable), power-related channel monitoring (npPwrTable), and email-based trap notification recipients. Its monitoring value is squarely on hardware/environmental status: npRelayState and npRelayMode report the current state and operating mode of each controllable relay channel, while npPwrTable/npPwrChannelN track power channel status, letting operators detect that a relay-controlled device is in the wrong state, or that a power channel has failed, and receive email alerts (npTrapEmailTo) when this occurs. No explicit dependency on other IETF MIBs is shown in the available objects, consistent with this being a compact, self-contained proprietary device MIB. It is typically deployed at unmanned/remote sites (cell sites, cabinets, small server rooms) where a NetPing device provides basic environmental sensing and remote relay control over SNMP with email alerting. Engineers can download the DKSF-202-9-X-X-1 file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in DKSF-202-9-X-X-1. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • NetPing DKSF-202 remote environmental monitoring/relay control device

Monitoring Examples

An admin would poll npRelayTable (via npRelayN/npRelayState) to confirm a specific relay channel is in its expected on/off state, and use npRelayMode along with npRelayFlip to understand or trigger the relay's switching behavior remotely. npPwrTable/npPwrChannelN lets an operator monitor the status of power channels connected to the device, spotting a channel that has lost power. npTrapEmailTo configures where alert emails are sent when a monitored condition (e.g., a relay state change or power loss) occurs, and npRelayMemo provides a human-readable label for each relay to aid identification during an incident.

What Can Be Monitored

  • relay channel state
  • relay operating mode
  • power channel status
  • email alert recipient configuration
  • relay identification/label
Imported Objects

From SNMPv2-MIB

snmpTrapsOBJECT-IDENTITY

From SNMPv2-SMI

Counter32
Counter64
Gauge32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
TimeTicks
enterprises

From SNMPv2-TC

DisplayString
TEXTUAL-CONVENTION
TimeStamp
TruthValue

How to Use in IPNetwork Monitor

Example using npIoPulseCounter OID:

Select a NetPing DKSF-202 remote environmental monitoring/relay control device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type npIoPulseCounter into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the pulse Counter on IO input line (counts positive fronts) Write 0 to reset. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Generic MIB for NetPing remote sensing and control devices with environmental monitoring capabilities.

Start monitoring NetPing DKSF-202 remote environmental monitoring/relay control device with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download DKSF-202-9-X-X-1