JCImSeries-MIB

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsJCImSeries-MIB

Organization: Johnson Controls

Last Updated: 2001-10-25

Category: Domain: Environmental Monitoring, Vendor: Johnson Controls

Description: Defines managed objects for Johnson Controls iSeries building management controllers, supporting BACnet and SNMP-based facility monitoring.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is JCImSeries-MIB?

JCImSeries-MIB is a Johnson Controls MIB module for their Metasys building automation platform, generating SNMP traps from Metasys OPC (OLE for Process Control) event data. It is trap/alarm-oriented, exposing building-automation event attributes rather than typical interface or CPU-style counters. Its monitoring role centers on software-level fault/event conditions in the building system—severity, source, timestamp, message text, and condition/sub-condition state—serving as an event monitoring bridge for facility alarms rather than raw hardware telemetry. It depends conceptually on the Metasys OPC/BACnet event model that it translates into SNMP traps. It is typically deployed in Johnson Controls Metasys building automation systems (HVAC, access control, energy management) where facility alarms need to be forwarded to an SNMP-based monitoring system. Engineers can download the JCImSeries-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in JCImSeries-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Johnson Controls Metasys iSeries building automation controllers

Monitoring Examples

The MIB centers on trap fields like opcSeverity, opcEventType, opcCondition, and opcSubCondition, along with opcSource, opcMessage, and opcTimeStamp; a monitoring system would use these fields in an incoming opcTraps notification to identify which building point raised the alarm, its severity level, and whether the condition (opcCondition/opcSubCondition) is active or has cleared—for example, an HVAC unit reporting a high-severity fault that needs operator attention.

What Can Be Monitored

  • OPC event severity
  • OPC event source
  • OPC event/condition type
  • event timestamp
  • condition active/cleared state
Imported Objects

From JCIControlsGroup-MIB

mSeriesOBJECT-IDENTITY

From RFC1213-MIB

ifIndex

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE

From SNMPv2-TC

DisplayString
OIDs

RFC description

Johnson Controls vendor-private MIB for ImSeries building management devices with condition-based SNMP traps.

Start monitoring Johnson Controls Metasys iSeries building automation controller with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download JCImSeries-MIB