CNT21-MIB

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsCNT21-MIB

Organization: Computer Network Technology Corporation

Last Updated: 2001-10-23

Category: Fibre Channel and Storage, Vendor: CNT

Description: Manages CNT 2.1 series Fibre Channel switch hardware and port configuration objects.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is CNT21-MIB?

CNT21-MIB is a proprietary MIB from CNT (Computer Network Technology) for their 2.1-series Fibre Channel switch product line, covering hardware and port-level configuration for FC switching gear used in SAN environments. It exposes interface/port configuration objects and likely status fields for the switch's Fibre Channel ports and internal hardware modules. Its monitoring value centers on hardware status: verifying that Fibre Channel ports and switch hardware components are operationally up and correctly configured, which is critical since FC switch failures directly disrupt storage-area-network connectivity. As a switch-hardware MIB it plausibly builds on general Fibre Channel/interface conventions but no explicit dependency on another named MIB is evident from the module text. It is deployed in enterprise SAN environments where CNT (later part of McDATA/Brocade lineage) FC switches interconnect servers and storage arrays. Engineers can download the CNT21-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in CNT21-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • CNT 2.1-series Fibre Channel SAN switches

Monitoring Examples

No sample objects were supplied for this MIB, so specifics are inferred: an operator would likely poll a per-port interface table (following a cntIf*Table pattern implied by 'CNT Interface MIB') to check port operational/administrative status and hardware configuration for each Fibre Channel port. A port unexpectedly reporting a down or degraded state would signal a failed SFP, cable, or port hardware issue disrupting SAN connectivity for attached hosts or storage. This is a plausible inference rather than a confirmed table structure since no object names were provided.

What Can Be Monitored

  • Fibre Channel port operational status
  • port hardware configuration
  • switch hardware component state
Imported Objects

From CNT2-MIB

cnt2Mib2OBJECT-IDENTITY

From IANAifType-MIB

IANAifType

From RFC-1212

OBJECT-TYPE

From RFC1155-SMI

Counter
Gauge
TimeTicks
enterprises

From RFC1213-MIB

DisplayString
PhysAddress

From SNMPv2-SMI

Counter32
Counter64
Integer32
MODULE-IDENTITY
Unsigned32

From SNMPv2-TC

TimeStamp
TruthValue

How to Use in IPNetwork Monitor

Example using cnt2XIfInOctets OID:

Select a CNT 2.1-series Fibre Channel SAN switch (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cnt2XIfInOctets into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of octets received on the interface, including framing characters. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Enterprise MIB module for Compact Networks devices used for network management and SNMP monitoring, included in various network monitoring platforms and management systems.

Start monitoring CNT 2.1-series Fibre Channel SAN switch (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download CNT21-MIB