| OID symbolic | OID numeric | Type | Access | Description |
| cmplsTeStdExtMIB | 1.3.6.1.4.1.9.9.738 | | | This MIB module contains Cisco specific managed object
definitions for MPLS Traffic Engineering (TE), not contained in
MPLS-TE-STD-MIB.
The auto bandwidth feature enables MPLS TE Tunnels to adapt
automatically their bandwidth to their actual load. |
| cmplsTeStdExtMIBNotifs | 1.3.6.1.4.1.9.9.738.0 | | | |
| NTF cmplsTunnelPreempt | 1.3.6.1.4.1.9.9.738.0.1 | | | This notification is generated when a MPLS TE tunnel is
preempted. |
| NTF cmplsTunnelInsuffBW | 1.3.6.1.4.1.9.9.738.0.2 | | | This notification is generated when a MPLS TE tunnel could not
be setup or reoptimized. |
| NTF cmplsTunnelReRoutePending | 1.3.6.1.4.1.9.9.738.0.3 | | | This notification is generated when re-route is required
for the tunnel. |
| NTF cmplsTunnelReRoutePendingClear | 1.3.6.1.4.1.9.9.738.0.4 | | | This notification is generated when tunnel no longer needs to
be re-routed. |
| NTF cmplsTunnelBringupFail | 1.3.6.1.4.1.9.9.738.0.5 | | | This notification is generated when MPLS TE tunnel failed to
come up |
| cmplsTeStdExtMIBObjects | 1.3.6.1.4.1.9.9.738.1 | | | |
| cmplsTunnelAutoBWTable | 1.3.6.1.4.1.9.9.738.1.1 | | not-accessible | This table is used in order to manage auto bandwidth data.
This table is sparse dependent on the mplsTunnelTable. An entry
in this table exists for each mplsTunnelEntry with a
mplsTunnelRole of 'head' or 'headTail'. Each row contains
auto-bandwidth data for the tunnel identified by the indexes
defined later.
An entry is created as soon as a 'head' or 'headTail' MPLS TE
tunnel is configured in the system. |
| cmplsTunnelAutoBWEntry | 1.3.6.1.4.1.9.9.738.1.1.1 | | not-accessible | A conceptual row in cmplsTunnelAutoBWTable. There is an entry
in this table for each MPLS-TE tunnel with mplsTunnelRole
equals to 'head' or 'headTail'. |
| INT cmplsTunnelAutoBWStatus | 1.3.6.1.4.1.9.9.738.1.1.1.1 | INTEGER | read-only | This object indicates the operational status [or mode] of the
auto bandwidth algorithm:
- autoBWDisabled: The auto-bandwidth algorithm is not running;
- autoBWEnabled: The auto-bandwidth algorithm is running;
- autoBWCollectOnlyMode: The auto-bandwidth algorithm is
running,
but the bandwidth applications are
disabled; |
| U32 cmplsTunnelAutoBWMin | 1.3.6.1.4.1.9.9.738.1.1.1.2 | Unsigned32 | read-write | This object specifies the minimum bandwidth that the
auto-bandwidth algorithm can apply to a tunnel when the
adjustment threshold is overcome.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWMax | 1.3.6.1.4.1.9.9.738.1.1.1.3 | Unsigned32 | read-write | This object specifies the maximum bandwidth that the
auto-bandwidth algorithm can apply to a tunnel when the
adjustment threshold is overcome.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| CMP cmplsTunnelAutoBWAdjThreshPercs | 1.3.6.1.4.1.9.9.738.1.1.1.4 | CmplsTunnelBWPercent | read-write | This object specifies the adjustment threshold percentage that
needs to be overcome in order to trigger a new bandwidth
application.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWAdjThreshBW | 1.3.6.1.4.1.9.9.738.1.1.1.5 | Unsigned32 | read-write | This object specifies the adjustment threshold bandwidth that
needs to be overcome in order to trigger a new bandwidth
application.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| CMP cmplsTunnelAutoBWOverflowThreshPercs | 1.3.6.1.4.1.9.9.738.1.1.1.6 | CmplsTunnelBWPercent | read-write | This object specifies the adjustment threshold percentage that
needs to be overcome in order to trigger an overflow occurrence.
If the application period has not completed when a
cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new
bandwidth will be applied.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWOverflowThreshBW | 1.3.6.1.4.1.9.9.738.1.1.1.7 | Unsigned32 | read-write | This object specifies the adjustment threshold bandwidth that
needs to be overcome in order to trigger an overflow occurrence.
If the application period has not completed when a
cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new
bandwidth will be applied.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWOverflowLimit | 1.3.6.1.4.1.9.9.738.1.1.1.8 | Unsigned32 | read-write | This object specifies the number of consecutive collections
exceeding overflow threshold.
If the application period has not completed when a
cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new
bandwidth will be applied.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| CMP cmplsTunnelAutoBWUnderflowThreshPercs | 1.3.6.1.4.1.9.9.738.1.1.1.9 | CmplsTunnelBWPercent | read-write | This object specifies the adjustment threshold percentage that
needs to be overcome in order to trigger an underflow
occurrence.
If the application period has not completed when a
cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new
bandwidth will be applied.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWUnderflowThreshBW | 1.3.6.1.4.1.9.9.738.1.1.1.10 | Unsigned32 | read-write | This object specifies the adjustment threshold bandwidth that
needs to be overcome in order to trigger an underflow
occurrence.
If the application period has not completed when a
cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new
bandwidth will be applied.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWUnderflowLimit | 1.3.6.1.4.1.9.9.738.1.1.1.11 | Unsigned32 | read-write | This object specifies the number of consecutive collections
under the underflow threshold.
If the application period has not completed when a
cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new
bandwidth will be applied.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWApplicationFrequency | 1.3.6.1.4.1.9.9.738.1.1.1.12 | Unsigned32 | read-write | This object specifies the bandwidth application period.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWCollectionFrequency | 1.3.6.1.4.1.9.9.738.1.1.1.13 | Unsigned32 | read-write | This object specifies the sampling period for data rates.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWLastAppliedBW | 1.3.6.1.4.1.9.9.738.1.1.1.14 | Unsigned32 | read-only | This object indicates the last bandwidth applied by the
auto-bandwidth algorithm.
It will be set to zero if no bandwidth has been applied yet.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| C32 cmplsTunnelAutoBWApplicationsEx | 1.3.6.1.4.1.9.9.738.1.1.1.15 | Counter32 | read-only | This object indicates the number of auto bandwidths applied.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| INT cmplsTunnelAutoBWLastApplicationTrigger | 1.3.6.1.4.1.9.9.738.1.1.1.16 | INTEGER | read-only | This object indicates the trigger reason for the last bandwidth
application.
If mplsTunnelInstance is zero this object will be set to
'applicationNone'.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| C32 cmplsTunnelAutoBWOverflowApplications | 1.3.6.1.4.1.9.9.738.1.1.1.17 | Counter32 | read-only | This object indicates the number of bandwidth applications
due to overflow occurrences.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| C32 cmplsTunnelAutoBWOverflowOccurrences | 1.3.6.1.4.1.9.9.738.1.1.1.18 | Counter32 | read-only | This object indicates the number of overflow occurrences
since last application period.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| C32 cmplsTunnelAutoBWUnderflowApplications | 1.3.6.1.4.1.9.9.738.1.1.1.19 | Counter32 | read-only | This object indicates the number of bandwidth applications due
to underflow occurrences.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| C32 cmplsTunnelAutoBWUnderflowOccurrences | 1.3.6.1.4.1.9.9.738.1.1.1.20 | Counter32 | read-only | This object indicates the number of underflow occurrences
since last application period.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| G32 cmplsTunnelAutoBWUnderflowHighestBW | 1.3.6.1.4.1.9.9.738.1.1.1.21 | Gauge32 | read-only | This object indicates the highest sample collected during
an underflow sequence.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWRequested | 1.3.6.1.4.1.9.9.738.1.1.1.22 | Unsigned32 | read-only | This object indicates the bandwidth requested by the
auto-bandwidth algorithm.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWSignaled | 1.3.6.1.4.1.9.9.738.1.1.1.23 | Unsigned32 | read-only | This object indicates the bandwidth signaled by the
auto-bandwidth algorithm.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWCollectOnlyRequested | 1.3.6.1.4.1.9.9.738.1.1.1.24 | Unsigned32 | read-only | This object indicates the bandwidth that would have been
requested by the auto-bandwidth algorithm if the auto-bandwidth
functionality was enabled. If the collect only mode is enabled,
the bandwidth change request will not be executed.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWHighest | 1.3.6.1.4.1.9.9.738.1.1.1.25 | Unsigned32 | read-only | This object indicates the highest bandwidth sampled by
the auto-bandwidth algorithm.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| C32 cmplsTunnelAutoBWCollectedSamples | 1.3.6.1.4.1.9.9.738.1.1.1.26 | Counter32 | read-only | This object indicates the samples collected since the last
auto-bandwidth application.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| U32 cmplsTunnelAutoBWJitter | 1.3.6.1.4.1.9.9.738.1.1.1.27 | Unsigned32 | read-only | This object indicates the auto-bandwidth application jitter.
Jitter is the extra time to be added to the application interval
the first time the auto bandwidth is applied.
If mplsTunnelInstance is zero this object will be set to zero.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| INT cmplsTunnelAutoBWAppRejectReason | 1.3.6.1.4.1.9.9.738.1.1.1.28 | INTEGER | read-only | This object indicates the reason for the bandwidth application
rejection.
This object value is not aplicable if cmplsTunnelAutoBWStatus is
'autoBWDisabled'. |
| cmplsTeTunnelReasonTable | 1.3.6.1.4.1.9.9.738.1.2 | | not-accessible | This table is used in order to indicate the causes for the
notifications. |
| cmplsTeTunnelReasonEntry | 1.3.6.1.4.1.9.9.738.1.2.1 | | not-accessible | A conceptual row in cmplsTunnelReasonTable. |
| INT cmplsTunnelReoptReason | 1.3.6.1.4.1.9.9.738.1.2.1.1 | INTEGER | accessible-for-notify | This object indicates the reason of the tunnel reoptimization:
- unknown: the reason is not known
- periodicTimerExpiry: Periodic Reoptimization
- bandwidthCLIChange: the tunnel bandwidth has been
changed from CLI
- bandwidthOverflow: an auto-bandwidth overflow
occurred
- bandwidthUnderflow: an auto-bandwidth underflow
occured
- bandwidthAdjustment: an auto-bandwidth application
occured
- fastReRoute: a fast re-route occured
- cliRequest: User-triggerred
- metricTypeChange: tunnel metric type has been
changed
from CLI
- preferredPathExists: preferred-path-exists message
received from a downstream node
- poSwitchoverTrigger: User-requested path-option
switchover
- bandwidthChange: bandwidth change
- autoBandwidth: Auto Bandwidth
- remergeError: Remerge Error
- dueToMaximumMetric: Reoptimization due to
receiving an LSA with MAX metric
- pathProtectionSwitchover: Path Protection Switchover
- iEPEnableReoptimization: IEP Enable Reoptimization
- affinityPathVerificationFail: Affinity path
verification failure
- softPreemption: soft preemption (see RFC 5712)
- preferredTreeExists: preferred-tree-exists message
received from a downstream node
- costLimitPathVerificationFail: Cost Limit path
verification failure
- linkupReopt: link state up
- iEPChangeReoptimization: inuse explicit-path change
- poChangeReoptimization: inuse path-option change
- bfdSessionTypeChange: a bfd session type change occured
This object is intended to be included in the trap
mplsTunnelReoptimized defined in MPLS-TE-STD-MIB. |
| INT cmplsTunnelInsuffBWFailedOperation | 1.3.6.1.4.1.9.9.738.1.2.1.2 | INTEGER | accessible-for-notify | This object indicates whether the tunnel could not be setup or
reoptimized because of insufficient bandwidth:
- unknown: the reason is not known
- failedToSetup: insufficient bandwidth during
initial setup
- failedToReoptimize: insufficient bandwidth during
reoptimization |
| INT cmplsTunnelPreemptionType | 1.3.6.1.4.1.9.9.738.1.2.1.3 | INTEGER | accessible-for-notify | This object indicates LSP Preemption type of this LSP:
- unknown: the type is not known
- hardPreemption: the preempted LSP resources are
freed immediately; the LSP is broken immediately
and the traffic is disrupted.
- softPreemption: the resources release pending on the
reoptimization of this LSP. The head of the LSP
reroutes the traffic before the LSP is broken.
- frrSoftPreemption: similar to softPreemption. In this
case the traffic of the soft preempted LSP is switched to
the backup.
See: Farrel, A., Interim Report on MPLS Pre-emption,
draft-farrel-mpls-preemption-interim-00.txt, work in progress |
| IPt cmplsTunnelPreemptionLinkAddrType | 1.3.6.1.4.1.9.9.738.1.2.1.4 | InetAddressType | accessible-for-notify | This object indicates the address type of the link where the
preemption occurs - another, higher priority LSP is being
admitted on this link and there is not enough bandwidth for it
causing this LSP to be preempted (removed) from this link:
- unknown: the object cmplsTunnelPreemptionLinkAddr does not
contain any address
- ipv4: the object cmplsTunnelPreemptionLinkAddr contains
the IPv4 address
- ipv6: the object cmplsTunnelPreemptionLinkAddr contains
the IPv6 address |
| IP cmplsTunnelPreemptionLinkAddr | 1.3.6.1.4.1.9.9.738.1.2.1.5 | InetAddress | accessible-for-notify | This object indicates the address of the link where the
preemption occurs - another, higher priority LSP is being
admitted on this link and there is not enough bandwidth for it
causing this LSP to be preempted (removed) from this link. |
| INT cmplsTunnelReRoutePendingClearReason | 1.3.6.1.4.1.9.9.738.1.2.1.6 | INTEGER | accessible-for-notify | This object indicates the reason why the tunnel
is not longer in the reroute pending state:
- unknown: the reason is unknown
- reoptimized: the tunnel has been reoptimized
- reinstated: the tunnel has been reinstated |
| cmplsTeTunnelFailReasonTable | 1.3.6.1.4.1.9.9.738.1.3 | | not-accessible | This table is used in order to indicate the causes for the
MPLS TE tunnel failure notifications. |
| cmplsTeTunnelFailReasonEntry | 1.3.6.1.4.1.9.9.738.1.3.1 | | not-accessible | A conceptual row in the cmplsTeTunnelFailReasonTable. |
| INT cmplsTeFailReasonType | 1.3.6.1.4.1.9.9.738.1.3.1.1 | INTEGER | read-only | This object indicates the type (category) of fail reason. |
| I32 cmplsTeFailReason | 1.3.6.1.4.1.9.9.738.1.3.1.2 | Integer32 | read-only | This object indicates specific fail reason value based on the
fail reason type indicated by cmplsTeFailReasonType.
Fail Reason Type Fail Reason Value Type
---------------- -----------------------
bfd(2) CiscoBfdDiag
generalTe(3) CmplsTeTunnelDiag
This object is replaced by cmplsTeFailReasonRev |
| INT cmplsTeFailReasonRev | 1.3.6.1.4.1.9.9.738.1.3.1.3 | INTEGER | accessible-for-notify | This object provieds more deails on fail reason.
cmplsTeFailReason values for reasonType bfd(2) mirror the
CiscoBfdDiag values:
- noDiagnostic
No bfd diagnostic info
- controlDetectionTimeExpired
Control Detection Timer Expired
- echoFunctionFailed
Echo Function Failed
- neighborSignaledSessionDown
Neighbor Signaled Session Down
- forwardingPlaneReset
Forwarding Plane Reset
- pathDown
Path Down
- concatenatedPathDown
Concatenated Path Down
- administrativelyDown
Administratively Down
- reverseConcatenatedPathDown
Reverse Concatenated Path Down
- unknown
Unknown error code
cmplsTeFailReason values for reasonType generalTe(3) mirror
the CmplsTeTunnelDiag values:
- unknown
Unknown error code
- bfdSessionBringupTimeout
bfd session failed to come up before timeout |
| cmplsTunnelLoadshareTable | 1.3.6.1.4.1.9.9.738.1.4 | | not-accessible | This table is used in order to manage load data. |
| cmplsTunnelLoadshareEntry | 1.3.6.1.4.1.9.9.738.1.4.1 | | not-accessible | A conceptual row in cmplsTunnelLoadshareTable. There is an
entry in this table for each MPLS-TE tunnel. |
| U32 cmplsTunnelLoadShare | 1.3.6.1.4.1.9.9.738.1.4.1.1 | Unsigned32 | read-write | This object indicates the Load-share as defined by the
bandwidth attribute (default) or explicitly configured
using the load-share command under tunnel configuration. |
| cmplsTeStdExtMIBObjectsGlobal | 1.3.6.1.4.1.9.9.738.1.5 | | | |
| INT cmplsTeLoadshareBalance | 1.3.6.1.4.1.9.9.738.1.5.1 | INTEGER | read-write | This object indicates if the load-share balance
is equal or unequal. |
| cmplsTeStdExtMIBConform | 1.3.6.1.4.1.9.9.738.2 | | | |
| cmplsTeStdExtMIBCompliances | 1.3.6.1.4.1.9.9.738.2.1 | | | |
| cmplsTeStdExtMIBCompliance | 1.3.6.1.4.1.9.9.738.2.1.1 | | | This is the main compliance statement for the MIB. |
| cmplsTeStdExtMIBCompliancesRev1 | 1.3.6.1.4.1.9.9.738.2.1.2 | | | This is the main compliance statement for the MIB.
Adding the extended traps. |
| cmplsTeStdExtMIBComplianceRev2 | 1.3.6.1.4.1.9.9.738.2.1.3 | | | This is the main compliance statement for the MIB |
| cmplsTeStdExtMIBComplianceRev3 | 1.3.6.1.4.1.9.9.738.2.1.4 | | | This is the main compliance statement for the MIB |
| cmplsTeStdExtMIBComplianceRev4 | 1.3.6.1.4.1.9.9.738.2.1.5 | | | This is the main compliance statement for the MIB |
| cmplsTeStdExtMIBGroups | 1.3.6.1.4.1.9.9.738.2.2 | | | |
| cmplsTeStdExtMIBAutoBWObjectGroup | 1.3.6.1.4.1.9.9.738.2.2.1 | | | This contains the main MPLS TE extensions groups. |
| cmplsTeStdExtMIBAutoBWOptionalGroup | 1.3.6.1.4.1.9.9.738.2.2.2 | | | This contains the optional MPLS TE extensions groups. |
| cmplsTeStdExtMIBTrapObjectsGroup | 1.3.6.1.4.1.9.9.738.2.2.3 | | | This contains the MPLS TE extended traps objects.
This object is replaced by
cmplsTeStdExtMIBTrapObjectsGroupRev1 |
| cmplsTeStdExtMIBTrapObjectsGroupRev1 | 1.3.6.1.4.1.9.9.738.2.2.4 | | | This contains the optional MPLS TE extensions groups. |
| cmplsTeStdExtMIBTrapGroup | 1.3.6.1.4.1.9.9.738.2.2.5 | | | This contains the MPLS TE extended traps. |
| cmplsTeStdExtMIBFailTeTrapGroup | 1.3.6.1.4.1.9.9.738.2.2.6 | | | This contains the MPLS TE extended traps related to BFD over
TE LSP. |
| cmplsTeStdExtMIBFailTeTrapObjectsGroup | 1.3.6.1.4.1.9.9.738.2.2.7 | | | This contains the MPLS TE extended traps objects related to BFD
over TE LSP.
This object is replaced by
cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 |
| cmplsTeStdExtMIBLoadShareObjectsGroup | 1.3.6.1.4.1.9.9.738.2.2.8 | | | This contains the MPLS TE extended objects related to
TE loadshare. |
| cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 | 1.3.6.1.4.1.9.9.738.2.2.9 | | | This contains the MPLS TE extended traps objects related to BFD
over TE LSP. |