All MIBs › CISCO-DS3-MIB
Organization: Cisco Systems, Inc.
Last Updated: 2002-05-21
Category: Cisco Devices, Network Interfaces
Description: Provides Cisco-specific management objects for DS3/T3 interfaces, supplementing RFC 2496 with additional performance and framing controls.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CISCO-DS3-MIB?
CISCO-DS3-MIB is a Cisco Systems proprietary MIB extending the standard DS3 MIB (RFC 2496) with additional line-configuration and alarm-threshold objects. Its configuration table records line type, AIS-C-bit checking, FEAC validation, out-of-frame criteria, transmitted/expected trace strings, trace alarm, internal equalizer, and near/far-end line-loopback status, while an alarm-configuration table sets near-end/far-end alarm up/down debounce counts and thresholds, statistical-alarm severity, and 15-minute/24-hour thresholds for line-code-violation (LCV) and line-errored-second (LES) counts. As a configuration/performance MIB it lets an administrator tune DS3 alarm debounce and error-rate thresholds to match the carrier's circuit-quality tolerance. It is deployed on Cisco routers with DS3 interfaces. Engineers can download the CISCO-DS3-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CISCO-DS3-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Cisco routers (DS3 interfaces)
Monitoring Examples
An administrator checks cds3LCV24HrThreshold and cds3LES24HrThreshold to confirm alarm sensitivity is tuned appropriately before troubleshooting a DS3 circuit generating frequent statistical alarms.
What Can Be Monitored
- DS3 line configuration and alarm/error thresholds
This MIB depends on
Related MIBs
Imported Objects
From CISCO-SMI
| ciscoMgmt | OBJECT-IDENTITY |
From IF-MIB
| ifIndex | OBJECT-TYPE |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString |
How to Use in IPNetwork Monitor
Example using cds3RcvLOSCount OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| cds3Alarm | 1.3.6.1.4.1.9.9.132.1.2 | |||
| cds3AlarmConfig | 1.3.6.1.4.1.9.9.132.1.2.1 | |||
| cds3AlarmConfigEntry | 1.3.6.1.4.1.9.9.132.1.2.1.1.1 | not-accessible | An entry in the T3/E3 Alarm Configuration Table. The entries are automatically created for an ifType value of 'ds3'(30), with default values for objects. Thresholds may be configured for: Line Code Violations(LCV), LineErrored Seconds(LES), Line Severely Errored Seconds(LSES), P-bit Coding Violations(PCV), P-bit Errored Seconds(PES), P-bit Severely Errored Seconds(PSES), Severely Errored Seconds(SES), Severely Errored Framing Seconds(SEFS), Unavailable Seconds(UAS), C-bit coding violations(CCV), C-bit errored seconds(CES), C-bit errored seconds(CSES). Once these thresholds are exceeded, minor or major alarms are raised. Please refer to RFC2496 for descriptions of these errors. | |
| cds3AlarmConfigPlcpEntry | 1.3.6.1.4.1.9.9.132.1.2.1.2.1 | not-accessible | An entry in the DS3 PLCP Alarm Configuration table. The entries contain parameters to configure DS3 PLCP error statistics thresholds, so that an alarm is raised whenever any threshold is exceeded. The entries are automatically created for active DS3 interfaces with Plcp framing enabled, with default values for objects. | |
| cds3AlarmConfigPlcpTable | 1.3.6.1.4.1.9.9.132.1.2.1.2 | not-accessible | The ATM interface PLCP alarm configuration table. PLCP is a sublayer over the DS3 interface, that carries ATM cells. | |
| cds3AlarmConfigTable | 1.3.6.1.4.1.9.9.132.1.2.1.1 | not-accessible | The DS3 interface alarm configuration table. This table contains the parameters associated with detecting and declaring alarms for the interface. The parameters include severity of alarm, alarm integration parameters and 15 minute and 24 hour thresholds. | |
| cds3AlarmPlcpEntry | 1.3.6.1.4.1.9.9.132.1.2.2.1 | not-accessible | An entry in the DS3 Plcp Alarm table. Bucket statistics(15 minute and 24 hour interval statistics) are gathered for each existing DS3 line with PLCP frame format selected. An entry is created automatically and is indexed by the DS3 line number. | |
| cds3AlarmPlcpTable | 1.3.6.1.4.1.9.9.132.1.2.2 | not-accessible | The Plcp interface alarm table. This table maintains the CV,ES,SES, SEFS and UAS for DS3 line with Plcp framing selected. Please refer to RFC2496 for description of these various error statistics. | |
| U32 cds3CCV15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.22 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3. |
| U32 cds3CCV24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.23 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3. |
| C32 cds3CCVCount | 1.3.6.1.4.1.9.9.132.1.3.1.1.4 | Counter32 | read-only | The counter associated with the number of C-Bit Coding Violations encountered by a T3/E3 interface. |
| C32 cds3CCVCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.8 | Counter32 | read-only | The number CCVs encounterd by the line since the start of current 24 hour period. |
| C32 cds3CCVPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.8 | Counter32 | read-only | The number CCVs encounterd by the line in the previous 24 hour period. |
| U32 cds3CES15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.24 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3. |
| U32 cds3CES24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.25 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. Not for E3. |
| C32 cds3CESCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.9 | Counter32 | read-only | The number of CESs encountered by the line since the start of current 24 hour period. |
| C32 cds3CESPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.9 | Counter32 | read-only | The number of CESs encountered by the line in the previous 24 hour period. |
| cds3Config | 1.3.6.1.4.1.9.9.132.1.1 | |||
| cds3ConfigEntry | 1.3.6.1.4.1.9.9.132.1.1.1.1 | not-accessible | An entry in the table. There is an entry for each available T3/E3 line, with an ifType value of 'ds3'(30). By default, lines are disabled. 'ifAdmin' from ifTable must be used to up the line. The objects in this table can be modified only when the line is up. | |
| cds3ConfigTable | 1.3.6.1.4.1.9.9.132.1.1.1 | not-accessible | The DS3 Configuration table. The table has objects for configuring a T3/E3 line. | |
| C32 cds3CPECount | 1.3.6.1.4.1.9.9.132.1.3.1.1.9 | Counter32 | read-only | The number of C-bit parity errors(CPERR) on a DS3 interface. This value is calculated over noninformation bits in the DS3 frame. |
| U32 cds3CSES15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.26 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3. |
| U32 cds3CSES24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.27 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. Not for E3. |
| C32 cds3CSESCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.10 | Counter32 | read-only | The number of CSESs encountered by the line since th start of current 24 hour period. |
| C32 cds3CSESPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.10 | Counter32 | read-only | The number of CSESs encountered by the line in the previous 24 hour period. |
| cds3Current24HrEntry | 1.3.6.1.4.1.9.9.132.1.3.5.1 | not-accessible | An entry in the T3/E3 current 24 hour counter table. The entries are automatically created for an ifType value of 'ds3'(30), when interface is made active. | |
| cds3Current24HrTable | 1.3.6.1.4.1.9.9.132.1.3.5 | not-accessible | The DS3 interface current 24 hour table. This table contains counters for current 24 hour interval. Threshold on this counters are configured through cds3AlarmConfigTable table. 24 hour interval is aligned to wall clock. | |
| C32 cds3EXZSCount | 1.3.6.1.4.1.9.9.132.1.3.1.1.6 | Counter32 | read-only | The number of Excessive Zeros(EXZ) by a T3/E3 interface. An EXZ is the occurrence of any string of zeros having length equal to or greater than 3 for B3ZS, or any string of zeros having length greater than 4 for HDB3. |
| U32 cds3FarEndLineLoopbackStatus | 1.3.6.1.4.1.9.9.132.1.1.1.1.10 | Unsigned32 | read-only | Indicates the loopback status of the far end DS3,DS1 when remote DS1 loopback request is initiated. The remote DS1 loopback is initiated by setting dsx3SendCode object to dsx3SendDS1LoopCode(5). For unchannelized DS3 applications DS1s are unassigned. Following table lists the mapping of Bit position to DS1 or DS3 lines and the value. Bit Position Line number value ---------------------------------------- 0 DS3 Line 0 = line loopback activate 1 = line loopback deactivate 1 DS1 line 1 0 = loop down 1 = loop up 2 DS1 line 2 0 = loop down 1 = loop up 3 DS1 line 3 0 = loop down 1 = loop up ... ... 28 DS1 line 29 0 = loop down 1 = loop up 29 all DS1 lines 0 = loop down 1 = loop up |
| U32 cds3FEAlarmDownCount | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.5 | Unsigned32 | read-write | This parameter specifies the decrement to the Far End alarm integration counters. The alarms are Alarm Indication Signal (AIS) and Remote Alarm Indication (RAI). The integration counter is decremented by this value every 10 ms (till zero), while no alarm persists. The counter is incremented by this value while there is no alarm. When the integration counter decrements to zero any previously declared Alarm is removed. |
| U32 cds3FEAlarmThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.6 | Unsigned32 | read-write | The value set in this object determines the value that the alarm integration counter must reach for an far end Alarm to be declared. If the up count is 6, the down count is 1 and the threshold 150, an Alarm is integrated in 2.5 sec and removed in 15 seconds. |
| U32 cds3FEAlarmUpCount | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.4 | Unsigned32 | read-write | This parameter specifies the increment to the Far End alarm integration counters. The alarms are Remote Alarm Indication (RAI) and Alarm Indication Signal(AIS). The integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by this value while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds cds3FEAlarmThreshold an Alarm of the severity specified for the particular far end alarm is declared. |
| C32 cds3FEBECount | 1.3.6.1.4.1.9.9.132.1.3.1.1.10 | Counter32 | read-only | The number of Far End Block Errors(FEBE) encountered by a T3/E3 interface.These include frame alignment errors, multiframe alignment errors, and C-bit parity errors. These errors are generated by the transmitter at the far end, and indicate that the transmitter,cabling or the upstream node is faulty. |
| C32 cds3FECount | 1.3.6.1.4.1.9.9.132.1.3.1.1.5 | Counter32 | read-only | The number of Framing Errors encountered by a T3/E3 interface. |
| INT cds3InternalEqualizer | 1.3.6.1.4.1.9.9.132.1.1.1.1.8 | INTEGER | read-write | This variable indicates whether the internal equalizer is being used or bypassed. Set this value depending on the line equipment to which the receiver is attached. Possible values are : use(1) : Use the internal equalizer byPass(2) : bypass internal equalizer(use external equalizer). This option allows easy interfacing of the device into systems already utilizing the external equalizers. |
| cds3IntervalEntry | 1.3.6.1.4.1.9.9.132.1.3.4.1 | not-accessible | An entry in the T3/E3 current interval table. | |
| C32 cds3IntervalLSESs | 1.3.6.1.4.1.9.9.132.1.3.4.1.2 | Counter32 | read-only | The number of LSESs encountered by the line in 15 minute interval. |
| INT cds3IntervalNumber | 1.3.6.1.4.1.9.9.132.1.3.4.1.1 | INTEGER | read-only | A number between 0 and 96, where 1 is the most recently completed 15 minute interval and 96 is the 15 minute interval completed 23 hours and 45 minutes prior to interval number 1. Interval number 0 refers to the current 15 minute data. |
| cds3IntervalTable | 1.3.6.1.4.1.9.9.132.1.3.4 | not-accessible | The DS3 interface interval table. | |
| U32 cds3LCV15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.8 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| U32 cds3LCV24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.9 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. |
| C32 cds3LCVCount | 1.3.6.1.4.1.9.9.132.1.3.1.1.7 | Counter32 | read-only | The count of both BPVs(Bipolar Violations) and EXZs(Excessive Zeros) encountered by a T3/E3 interface.An EXZ increments the LCV by one regardless of the length of the zero string. |
| C32 cds3LCVCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.1 | Counter32 | read-only | The number of LCVs encountered by the line since the start of current 24 hour period. |
| C32 cds3LCVPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.1 | Counter32 | read-only | The number of LCVs encountered by the line in the previous 24 hour period. |
| U32 cds3LES15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.10 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| U32 cds3LES24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.11 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. |
| C32 cds3LESCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.2 | Counter32 | read-only | The number LESs encountered by the line since the start of current 24 hour period. |
| C32 cds3LESPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.2 | Counter32 | read-only | The number LESs encountered by the line in the previous 24 hour period. |
| INT cds3LineAIScBitsCheck | 1.3.6.1.4.1.9.9.132.1.1.1.1.2 | INTEGER | read-write | When check(1) is set, then Alarm Indication Signal (AIS) is declared when '1010...'b is found and C-Bits are all zero. When ignore(2) is set, an AIS condition is declared when the '1010...'b is detected irrespective of the state of the C-Bits. Does not apply to the E3 interface. The value notApplicable(3) is used in case of the interfaces where this object is not applicable. The notApplicable(3) is not allowed in write operation. |
| INT cds3LineOOFCriteria | 1.3.6.1.4.1.9.9.132.1.1.1.1.4 | INTEGER | read-write | This entry specifies the out of frame(OOF) decision criteria. If 'bits3Of8' is specified then an OOF condition is declared if at least 3 of 8 framing bits are in error. When 'bits3Of16' is specified then OOF is declared if 3 of 16 framing bits are found to be in error. OOF is declared when errors are detected in the framing octets for four consecutive frames. This object does not apply to E3 interface. The value notApplicable(3) is used in case of the interfaces where this object is not applicable. The notApplicable(3) is not allowed in write operation. |
| INT cds3LineRcvFEACValidation | 1.3.6.1.4.1.9.9.132.1.1.1.1.3 | INTEGER | read-write | This entry specifies the FEAC (Far End Alarm and Control) code validation criteria. If 'fEACCodes4Of5' is specified, then a valid FEAC code is declared if 4 of 5 codes match. When 'fEACCodes8Of10' is specified, then a valid FEAC code is declared when 8 of 10 codes match. If disable(3) is specified, then FEAC code generation and detection is disabled. Does not apply to the E3 interface. |
| U32 cds3LineStatisticalAlarmState | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.30 | Unsigned32 | read-only | This is a bitmap of the DS3 Line Statistical alarms. It is represented as a sum where value 2^(N-1) is added to the sum if threshold corresponding to bit N is exceeded. Zero indicates no alarms. Itemized below are the individual alarm bits: BitPosition Alarm ----------- ----- 1 PES current 15 minute threshold exceeded 2 PES 24 hour threshold exceeded 3 PSES current 15 minute threshold exceeded 4 PSES 24 hour threshold exceeded 5 SEFS current 15 minute threshold exceeded 6 SEFS 24 hour threshold exceeded 7 UAS current 15 minute threshold exceeded 8 UAS 24 hour threshold exceeded 9 LCV current 15 minute threshold exceeded 10 LCV 24 hour threshold exceeded 11 PCV current 15 minute threshold exceeded 12 PCV 24 hour threshold exceeded 13 LES current 15 minute threshold exceeded 14 LES 24 hour threshold exceeded 15 CCV current 15 minute threshold exceeded 16 CCV 24 hour threshold exceeded 17 CES current 15 minute threshold exceeded 18 CES 24 hour threshold exceeded 19 CSES current 15 minute threshold exceeded 20 CSES 24 hour threshold exceeded 21 LSES current 15 minute threshold exceeded 22 LSES 24 hour threshold exceeded |
| INT cds3LineType | 1.3.6.1.4.1.9.9.132.1.1.1.1.1 | INTEGER | read-write | This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The values, in sequence, describe: Following values are applicable to DS3 interfaces only. ds3cbitadm : Indicates C-BIT ADM mode ds3cbitplcp : Indicates C-BIT PLCP mode ds3m23adm : Indicates M23 ADM mode ds3m23plcp : Indicates M23 PLCP mode dsx3M23 : Refer ANSI T1.107-1988 [9] dsx3SYNTRAN : Refer ANSI T1.107-1988 [9] dsx3CbitParity : Refer ANSI T1.107-1988 [9] dsx3ClearChannel : Refer ANSI T1.107-1988 [9] ds3cbitfrmronly : Indicates C-BIT FRAMER-ONLY mode ds3m23frmronly : Indicates M23 FRAMER-ONLY mode Following values are applicable to E3 interfaces only. e3g832adm : Indicates G.832 ADM mode e3g751adm : Indicates G.751 ADM mode e3g751plcp : Indicates G.751 PLCP mode e3Framed : Refer CCITT G.751 [12] e3Plcp : Refer ETSI T/NA(91)19 [14] e3g832frmronly : Indicates G.832 FRAMER-ONLY mode e3g751frmronly : Indicates G.751 FRAMER-ONLY mode. |
| U32 cds3LSES15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.28 | Unsigned32 | read-write | Used to set the 15 minute threshold for LSES(Line Severely Errored Seconds). The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| U32 cds3LSES24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.29 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. |
| C32 cds3LSESCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.11 | Counter32 | read-only | The number of LSESs (Line severedly errored seconds) encountered by the line since the start of current 24 hour period. |
| C32 cds3LSESPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.11 | Counter32 | read-only | The number of LSESs encountered by the line in the previous 24 hour period. |
| U32 cds3NEAlarmDownCount | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.2 | Unsigned32 | read-write | This parameter specifies the decrement to the Near End alarm integration counters. The alarms are LOS and LOF. The Default value is 1 and the integration counter is decremented by this value every 10 ms while no alarm persists. The counter is incremented by the value of cds3NEAlarmUpCount while there is no alarm (the counter does not decrement below zero). When the integration counter reaches zero any Alarm previously declared is removed. |
| U32 cds3NEAlarmThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.3 | Unsigned32 | read-write | The value set in this object determines the value that the alarm integration counter must reach for an near end alarm to be declared. If the up count is 6, and the threshold 150, an Alarm is integrated in 2.5 seconds. If the down count is 1, then alarm will be cleared in 15 seconds. |
| U32 cds3NEAlarmUpCount | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.1 | Unsigned32 | read-write | This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by the value of 'cds3NEAlarmDownCount' while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds 'cds3NEAlarmThreshold' an Alarm of the severity specified for the particular Near End alarm is declared. |
| U32 cds3NearEndLineLoopbackStatus | 1.3.6.1.4.1.9.9.132.1.1.1.1.9 | Unsigned32 | read-only | Indicates the loopback status of the near end DS1 on this DS3 when loopback request is indicated. Following table lists the mapping of Bit position to DS1 or DS3 lines and the value. Bit Position Line number value ---------------------------------------- 0 DS3 Line 0 = no loop(loop down) 1 = loop(loop up) 1 DS1 line 1 0 = loop down 1 = loop up 2 DS1 line 2 0 = loop down 1 = loop up 3 DS1 line 3 0 = loop down 1 = loop up ... ... 28 DS1 line 28 0 = loop down 1 = loop up 29 all DS1 lines 0 = loop up 1 = loop down |
| U32 cds3PCV15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.12 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3. |
| U32 cds3PCV24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.13 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3. |
| C32 cds3PCVCount | 1.3.6.1.4.1.9.9.132.1.3.1.1.8 | Counter32 | read-only | This is the count of P-bit Coding Violation(PCV) error event encountered by DS3 interface. For all DS3 applications, a coding violation error event is a P-bit Parity Error(PERR) event. The parity errors occur when the calculated parity in the information bits of the DS3 frame does not match up with an expected parity value. |
| C32 cds3PCVCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.3 | Counter32 | read-only | The number PCVs encountered by the line since the start of current 24 hour period. |
| C32 cds3PCVPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.3 | Counter32 | read-only | The number PCVs encountered by the line in the previous 24 hour period. |
| U32 cds3PES15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.14 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3. |
| U32 cds3PES24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.15 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3. |
| C32 cds3PESCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.4 | Counter32 | read-only | The number of PESs encountered by the line since the start of current 24 hour period. |
| C32 cds3PESPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.4 | Counter32 | read-only | The number of PESs encountered by the line in the previous 24 hour period. |
| U32 cds3PlcpBip8CV15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.2 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| C32 cds3PlcpBip8CV24HrBucket | 1.3.6.1.4.1.9.9.132.1.2.2.1.4 | Counter32 | read-only | The number of BIP-8 CVs encountered by the line in the last 24 hours. |
| U32 cds3PlcpBip8CV24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.3 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. |
| C32 cds3PlcpBip8CVCurrent | 1.3.6.1.4.1.9.9.132.1.2.2.1.3 | Counter32 | read-only | The number of BIP-8 code violations (CV) encountered by the line in the current 15 minute period. |
| U32 cds3PlcpBip8ES15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.4 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| C32 cds3PlcpBip8ES24HrBucket | 1.3.6.1.4.1.9.9.132.1.2.2.1.6 | Counter32 | read-only | The number of BIP-8 ES encountered by the line in the last 24 hour. |
| U32 cds3PlcpBip8ES24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.5 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. |
| C32 cds3PlcpBip8ESCurrent | 1.3.6.1.4.1.9.9.132.1.2.2.1.5 | Counter32 | read-only | The number of BIP-8 Errored Seconds(ES) encountered by the line in the current 15 minute period. |
| U32 cds3PlcpBip8SES15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.6 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| C32 cds3PlcpBip8SES24HrBucket | 1.3.6.1.4.1.9.9.132.1.2.2.1.8 | Counter32 | read-only | The number of BIP-8 SES encountered by the line in the last 24 hour. |
| U32 cds3PlcpBip8SES24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.7 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. |
| C32 cds3PlcpBip8SESCurrent | 1.3.6.1.4.1.9.9.132.1.2.2.1.7 | Counter32 | read-only | The number of BIP-8 Severely Errored Seconds(ES) encountered by the line in the current 15 minute period. |
| C32 cds3PlcpFEBECount | 1.3.6.1.4.1.9.9.132.1.3.2.1.7 | Counter32 | read-only | The count of Far End Block Errors (FEBE) detected. |
| C32 cds3PlcpFEBESecCount | 1.3.6.1.4.1.9.9.132.1.3.2.1.8 | Counter32 | read-only | The number of FEBE errored seconds. |
| C32 cds3PlcpFECount | 1.3.6.1.4.1.9.9.132.1.3.2.1.4 | Counter32 | read-only | The number of Framing Errors detected. |
| C32 cds3PlcpFESecCount | 1.3.6.1.4.1.9.9.132.1.3.2.1.5 | Counter32 | read-only | The number of Framing Error errored seconds. |
| U32 cds3PlcpLineAlarmState | 1.3.6.1.4.1.9.9.132.1.2.2.1.1 | Unsigned32 | read-only | This variable is a bitmap of the DS3 Line ALarms. It is represented as sum where value 2^(N-1) is added to the sum if alarm corresponding to bit N is exceeded. A value of zero for this object indicates no alarms. Itemized below are the individual bits: BitPosition Alarm ----------- ----- 1 Receiving RAI 2 Transmitting RAI 3 Receiving OOF 4 Near End Local Loopback in effect 5 Near End Remote Loopback in effect |
| U32 cds3PlcpLineStatisticalAlarmState | 1.3.6.1.4.1.9.9.132.1.2.2.1.2 | Unsigned32 | read-only | This variable is a bitmap of the DS3 Plcp Line Statictical Alarms. It is represented as a sum, where value 2^(N-1) is added to the sum if threshold corresponding to bit N is exceeded. A value of zero for this object indicates no alarms. Itemized below are the individual alarm bits: BitPosition Alarm ----------- ----- 1 Bip8CV 15 minute threshold exceeded 2 Bip8CV 24 hour threshold exceeded 3 Bip8ES 15 minute threshold exceeded 4 Bip8ES 24 hour threshold exceeded 5 Bip8SES 15 minute threshold exceeded 6 Bip8SES 24 hour threshold exceeded 7 Plcp SEFS 15 minute threshold exceeded 8 Plcp SEFS 24 hour threshold exceeded 9 Plcp UAS 15 minute threshold exceeded 10 Plcp UAS 24 hour threshold exceeded |
| C32 cds3PlcpRcvBip8Count | 1.3.6.1.4.1.9.9.132.1.3.2.1.1 | Counter32 | read-only | The number of of BIP-8 errors encountered by the line. |
| C32 cds3PlcpRcvOOFCount | 1.3.6.1.4.1.9.9.132.1.3.2.1.2 | Counter32 | read-only | The number of times Out of Frame(OOF) was detected with or without integrating to OOF alarm. |
| C32 cds3PlcpRcvRAICount | 1.3.6.1.4.1.9.9.132.1.3.2.1.3 | Counter32 | read-only | The number of times Remote Alarm Indication(RAI) was detected with or without integrating to RAI alarm. |
| C32 cds3PlcpSEFEBESecCount | 1.3.6.1.4.1.9.9.132.1.3.2.1.9 | Counter32 | read-only | The number of Severely errored FEBE seconds. |
| U32 cds3PlcpSEFS15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.8 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| C32 cds3PlcpSEFS24HrBucket | 1.3.6.1.4.1.9.9.132.1.2.2.1.10 | Counter32 | read-only | The number of BIP-8 SEFS encountered by the line in the last 24 hour. |
| U32 cds3PlcpSEFS24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.9 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. |
| C32 cds3PlcpSEFSCurrent | 1.3.6.1.4.1.9.9.132.1.2.2.1.9 | Counter32 | read-only | The number of BIP-8 Severely Errored Framing Seconds(SEFS) encountered by the line in the current 15-minute period. |
| C32 cds3PlcpSEFSecCount | 1.3.6.1.4.1.9.9.132.1.3.2.1.6 | Counter32 | read-only | The number of Severely errored Framing error seconds. |
| INT cds3PlcpStatisticalAlarmSeverity | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.1 | INTEGER | read-write | This variable sets up the severity of PLCP Statistical alarm. So when PLCP Statistical alarm is detected the module will send the alarm with appropriate severity. A value of none(3) indicates that no alarm will be raised. |
| cds3PlcpStatsEntry | 1.3.6.1.4.1.9.9.132.1.3.2.1 | not-accessible | An entry in the T3 Plcp Stats table. Statistics are gathered for each existing T3 line with PLCP frame format selected. An entry is created automatically and is indexed by the T3 line number. | |
| cds3PlcpStatsTable | 1.3.6.1.4.1.9.9.132.1.3.2 | not-accessible | T3 Plcp Statistics table. This table maintains the errors encountered by the T3 line with Plcp frame format selected, from the time the line is up.Line fails and goes down as a result of failures. When the line is brought back up again by the user after eliminating the error conditions, the statistics are cleared. | |
| U32 cds3PlcpUAS15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.10 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| C32 cds3PlcpUAS24HrBucket | 1.3.6.1.4.1.9.9.132.1.2.2.1.12 | Counter32 | read-only | The number of BIP-8 UAS encountered by the line in the last 24 hour. |
| U32 cds3PlcpUAS24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.2.1.11 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. |
| C32 cds3PlcpUASCurrent | 1.3.6.1.4.1.9.9.132.1.2.2.1.11 | Counter32 | read-only | The number of Unavailable Seconds(UAS) encountered by the line in the current 15-minute period. |
| cds3Previous24HrEntry | 1.3.6.1.4.1.9.9.132.1.3.6.1 | not-accessible | An entry in the T3/E3 current 24 hour counter table. The entries are automatically created for an ifType value of ds3(30), when interface is made active. | |
| cds3Previous24HrTable | 1.3.6.1.4.1.9.9.132.1.3.6 | not-accessible | The DS3 interface previous 24 hour table. This table contains counters for previous 24 hour interval. Implementation of this table is optional. | |
| U32 cds3PSES15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.16 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3. |
| U32 cds3PSES24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.17 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3. |
| C32 cds3PSESCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.5 | Counter32 | read-only | The number of PSESs encountered by the line since the start of current 24 hour period. |
| C32 cds3PSESPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.5 | Counter32 | read-only | The number of PSESs encountered by the line in the previous 24 hour period. |
| C32 cds3RAICount | 1.3.6.1.4.1.9.9.132.1.3.1.1.3 | Counter32 | read-only | The number of timesRemote Alarm Indication was detected with or without integrating to RAI alarm. |
| C32 cds3RcvAISCount | 1.3.6.1.4.1.9.9.132.1.3.1.1.11 | Counter32 | read-only | The number of times Alarm Indication Signals(AIS) were detected. The AIS indicates that an upstream failure has been detected by the far end. |
| C32 cds3RcvLOSCountEx | 1.3.6.1.4.1.9.9.132.1.3.1.1.1 | Counter32 | read-only | The number of times Loss of Signal was detected with or without integrating to LOS alarm. |
| C32 cds3RcvOOFCount | 1.3.6.1.4.1.9.9.132.1.3.1.1.2 | Counter32 | read-only | The number of times Out of Frame was detected with or without integrating to OOF alarm. |
| U32 cds3SEFS15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.18 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| U32 cds3SEFS24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.19 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval |
| C32 cds3SEFSCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.6 | Counter32 | read-only | The number of SEFSs encountered by the line since the start of the current 24 hour period. |
| C32 cds3SEFSPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.6 | Counter32 | read-only | The number of SEFSs encountered by the line in the start of the current 24 hour period. |
| INT cds3StatisticalAlarmSeverity | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.7 | INTEGER | read-write | This variable is used to setup the severity of any of the Statistical alarms. So when a Statistical Counter exceeds its specified threshold the system will send the alarm with appropriate severity. A value of none(3) indicates that no alarm will be raised. |
| cds3Stats | 1.3.6.1.4.1.9.9.132.1.3 | |||
| cds3StatsEntry | 1.3.6.1.4.1.9.9.132.1.3.1.1 | not-accessible | An entry in the T3/E3 Statistics table. Statistics are gathered for each existing T3/E3 line. An entry is created automatically for each T3/E3 line that is activated. | |
| cds3StatsMIBGroup | 1.3.6.1.4.1.9.9.132.8.2.2 | Collection of DS3/E3 line related real time counters. | ||
| cds3StatsTable | 1.3.6.1.4.1.9.9.132.1.3.1 | not-accessible | T3/E3 Statistics table. This table maintains the number of times the line encountered Loss of Signal(LOS), out of frame(LOF), Alarm Indication signals(AIS), Remote alarm indications(RAI), C-bit coding violations(CCV), Framing Errors(FE), from the time it is up. Line fails and goes down as a result of failures. When the line is brought back up again by the user the error statistics are cleared. | |
| INT cds3TraceAlarm | 1.3.6.1.4.1.9.9.132.1.1.1.1.7 | INTEGER | read-only | The value of this object is set to traceFailure(2) when DS3 line receives a trace does not match the 'cds3TraceToExpect'. |
| STR cds3TraceToExpect | 1.3.6.1.4.1.9.9.132.1.1.1.1.6 | DisplayString | read-write | G.832 Trail Trace string that is expected to be received from the other end. |
| STR cds3TraceToTransmit | 1.3.6.1.4.1.9.9.132.1.1.1.1.5 | DisplayString | read-write | Transmitted G.832 Trail Trace string. |
| U32 cds3UAS15MinThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.20 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. |
| U32 cds3UAS24HrThreshold | 1.3.6.1.4.1.9.9.132.1.2.1.1.1.21 | Unsigned32 | read-write | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval |
| C32 cds3UASCurrent24Hr | 1.3.6.1.4.1.9.9.132.1.3.5.1.7 | Counter32 | read-only | The number of UASs encountered by the line since the start of current 24 hour period. |
| C32 cds3UASPrevious24Hr | 1.3.6.1.4.1.9.9.132.1.3.6.1.7 | Counter32 | read-only | The number of UASs encountered by the line in the previous 24 hour period. |
| ciscoDs3AlarmMIBGroup | 1.3.6.1.4.1.9.9.132.8.2.3 | Collection of DS3/E3 related interval counters and threshold parameters. | ||
| ciscoDs3ConfMIBGroup | 1.3.6.1.4.1.9.9.132.8.2.1 | Collection of DS3/E3 line related configuration parameters. | ||
| ciscoDs3MIB | 1.3.6.1.4.1.9.9.132 | The MIB module to describe DS3 line objects. This is an extension to the standard DS3 MIB(RFC 2496). | ||
| ciscoDs3MIBCompliance | 1.3.6.1.4.1.9.9.132.8.1.1 | The Compliance statement for ciscoDs3 management group. | ||
| ciscoDs3MIBCompliances | 1.3.6.1.4.1.9.9.132.8.1 | |||
| ciscoDs3MIBConformance | 1.3.6.1.4.1.9.9.132.8 | |||
| ciscoDs3MIBGroups | 1.3.6.1.4.1.9.9.132.8.2 | |||
| ciscoDs3MIBObjects | 1.3.6.1.4.1.9.9.132.1 | |||
| ciscoDs3Previous24HrGroup | 1.3.6.1.4.1.9.9.132.8.2.6 | A collection DS3/E3 related previous 24 hour counters. | ||
| ciscoPlcpAlarmMIBGroup | 1.3.6.1.4.1.9.9.132.8.2.5 | Collection of PLCP related interval counters and threshold parameters. | ||
| ciscoPlcpCounterMIBGroup | 1.3.6.1.4.1.9.9.132.8.2.4 | Collection of PLCP related real time counters. |
RFC description
Manages DS3/E3 line configuration, alarms, and performance statistics on Cisco equipment.