All MIBs › ATM-SWITCHING-NODE-MIB
Description: MIB for configuration, interface management, bandwidth, and statistics on IBM ATM switching node hardware
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ATM-SWITCHING-NODE-MIB?
ATM-SWITCHING-NODE-MIB provides configuration, interface management, bandwidth, and statistics objects for IBM ATM switching node hardware. It exposes a switch table of administrative and operational state per slot, a module inventory table, and overall system state tracking. Its monitoring emphasis is on hardware status: per-slot admin/operational state and the timestamp of the last system state change reveal when a switching module has gone operationally down or when the node as a whole last transitioned state, both signs of a hardware fault. It is an IBM proprietary MIB that likely works alongside the standard ATM-MIB for interface-level statistics on the same node. It is used on IBM ATM switching nodes in legacy campus or backbone ATM networks. Engineers can download the ATM-SWITCHING-NODE-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ATM-SWITCHING-NODE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- IBM ATM switching node
Monitoring Examples
switchTable/switchEntry, indexed by switchSlotIndex, exposes switchAdminState and switchOperState, alongside a moduleTable for module inventory and top-level systemState and lastChange objects. An administrator would poll switchOperState per switchSlotIndex to detect a switching module that has gone operationally down, and check systemState and lastChange together to see when the node's overall state last transitioned, correlating that with a recent hardware fault.
What Can Be Monitored
- per-slot switch admin/operational state
- module inventory/status
- overall system state
- time of last state change
- IP ARP server ATM address
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| Counter | |
| DisplayString | |
| Gauge | |
| IpAddress | |
| TimeTicks | |
| enterprises |
From SNMPv2-TC
| TEXTUAL-CONVENTION |
How to Use in IPNetwork Monitor
Example using switchAggregateOutCells OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| ibm | 1.3.6.1.4.1.2 | |||
| ibmProd | 1.3.6.1.4.1.2.6 | |||
| atmSw | 1.3.6.1.4.1.2.6.33 | |||
| node | 1.3.6.1.4.1.2.6.33.1 | |||
| NTF helloTrap | 1.3.6.1.4.1.2.6.33.1.0.1 | A hello trap is sent: - when the system re-initializes: it is sent every minutes until an SNMP request is received or until 255 minutes have passed. - when one of the following parameters is changed: -- agent IP address(es) -- agent subnet mask(s) -- ATM address of the IP ARP server -- IP address of the default gateway The value of ifPhysAddress is the ATM address of the hub. The hello trap may be disabled. | ||
| NTF lockTrap | 1.3.6.1.4.1.2.6.33.1.0.2 | A lock trap is sent when a set request is rejected because it is suspected that this may cause to break the link between the agent and the manager. This may occur when: - isolating a slot - disabling a port if the request is received through this specific port/module/slot. | ||
| NTF change | 1.3.6.1.4.1.2.6.33.1.0.3 | A change trap is sent when one of the following MIB variables or group of variables is changed: - Date and Time reset - System Parameters (name, contact, location) changed - Interface changed: -- Administrative State (enabled/disabled) - Module changed: -- Administrative State (isolate/attach) When one of this variable is changed, the lastChange MIB object is also updated with the current date and time. When the Date and Time or the System Parameters changed, the interface number of the hub virtual interface is returned. This trap may be disabled. | ||
| NTF pvcFailure | 1.3.6.1.4.1.2.6.33.1.0.4 | A PVC failure trap is sent when a PVC becomes inoperational. | ||
| NTF callLoggingOverflow | 1.3.6.1.4.1.2.6.33.1.0.6 | A callLoggingOverflow trap is sent when the call logging table is about to wrap. | ||
| NTF moduleInstalled | 1.3.6.1.4.1.2.6.33.1.0.7 | An ATM module has been detected in the hub. | ||
| NTF moduleRemoved | 1.3.6.1.4.1.2.6.33.1.0.8 | An ATM module is no longer detected in the hub. | ||
| base | 1.3.6.1.4.1.2.6.33.1.1 | |||
| DAT dateTime | 1.3.6.1.4.1.2.6.33.1.1.1 | DateAndTime | read-write | The local date and time in the ATM agent. |
| DAT lastChange | 1.3.6.1.4.1.2.6.33.1.1.2 | DateAndTime | read-only | The date and time of the last major change detected: - date and time reset - agent IP address(es), subnet mask(s), default gateway changed - LAN Emulation or IP ARP server address(es) changed - system parameters (name, contact, location) changed - module Changed -- module added/removed -- administrative State changed (isolate/attached) - interface changed: -- administrative State changed (enabled/disabled) -- operational state changed This variable is updated in relation with the following traps: - hello trap - change trap - linkUp/linkDown traps. |
| INT lock | 1.3.6.1.4.1.2.6.33.1.1.3 | INTEGER | read-write | The purpose of this variable is to protect the path between the hub and the network management station. When set to secure (1), it is not possible to: - disable a port: -- if the SNMP request was received on this port -- if a LAN Emulation or an IP ARP server is on this port - isolate a module: -- if the SNMP request was received on this port -- if a LAN Emulation or an IP ARP server is on this port When set to unlock (2), the parameters referenced above can be modified for a limited time (30 seconds). When set to disabled (3), no protection is provided. Trying to modify one of these parameters results in a genErr error code in the Get-Response and a trap is returned to the agent. |
| ADR ipArpServerAtmAddress | 1.3.6.1.4.1.2.6.33.1.1.4 | AtmAddress | read-write | The ATM address of the ARP server used when communicating with the switch agent using Classical IP over ATM (RFC 1577). |
| INT systemState | 1.3.6.1.4.1.2.6.33.1.1.6 | INTEGER | read-write | The state of the ATM subsystem. Setting this variable to reset, causes a reset of all the ATM modules. When the active switch is in slots 9/10, switch-a is returned. When the active switch is in slots 11/12, switch-b is returned. |
| traps | 1.3.6.1.4.1.2.6.33.1.2 | |||
| INT hello | 1.3.6.1.4.1.2.6.33.1.2.1 | INTEGER | read-write | When disabled, the hello trap is neither sent. When enabled, the hello trap can be sent by the agent when the appropriate trap condition is detected. |
| physical | 1.3.6.1.4.1.2.6.33.1.3 | |||
| switchTable | 1.3.6.1.4.1.2.6.33.1.3.1 | not-accessible | This table controls slot attachement to the ATM switch. An ATM module is operational only when inserted in a slot which is defined as attached to the switch. | |
| switchEntry | 1.3.6.1.4.1.2.6.33.1.3.1.1 | not-accessible | Entries of switchTable. Each entry corresponds to a slot that is physically wired to the switch. These slots may be attached to or isolated from the ATM switch. | |
| INT switchSlotIndex | 1.3.6.1.4.1.2.6.33.1.3.1.1.1 | INTEGER | read-only | A slot number controlled by the switch. |
| INT switchAdminState | 1.3.6.1.4.1.2.6.33.1.3.1.1.2 | INTEGER | read-write | The desired state of the slot connection to the switch. When a slot is isolated from the switch, the switch traffic from this slot to the switch is disabled. As a result, if an ATM module is plugged in this slot, it will not be operational. When a slot is attached to the switch, the switch is ready to receive ATM traffic from this slot. As a result, if an ATM module is plugged in this slot, it can be used for ATM traffic. |
| INT switchOperState | 1.3.6.1.4.1.2.6.33.1.3.1.1.3 | INTEGER | read-only | The actual state of the slot connection to the switch. When the administrative state is set to ISOLATE, the operational state becomes ISOLATED. When the operational state is set to ATTACH, the operational state may become either ATTACHED or ISOLATED depending on the hardware current status of the slot. |
| moduleTable | 1.3.6.1.4.1.2.6.33.1.3.2 | not-accessible | This table provides the list of ATM modules in the hub. | |
| moduleEntry | 1.3.6.1.4.1.2.6.33.1.3.2.1 | not-accessible | Entries of moduleTable. | |
| INT moduleSlotIndex | 1.3.6.1.4.1.2.6.33.1.3.2.1.1 | INTEGER | read-only | The slot number for this module. |
| INT moduleType | 1.3.6.1.4.1.2.6.33.1.3.2.1.2 | INTEGER | read-only | The type of module attached to the ATM switch in this slot. The 'unknown' value is used when the ATM agent is unable to get information for this module (the module is isolated from the switch or is not operational). |
| STR moduleDescription | 1.3.6.1.4.1.2.6.33.1.3.2.1.3 | DisplayString | read-only | A textual description of this module. This description is blank when no description is available. |
| STR moduleSerialNumber | 1.3.6.1.4.1.2.6.33.1.3.2.1.4 | DisplayString | read-only | The serial number for this module. |
| STR moduleSoftwareVersion | 1.3.6.1.4.1.2.6.33.1.3.2.1.5 | DisplayString | read-only | The version and release number for this module firmware (microcode). |
| STR moduleHardwareVersion | 1.3.6.1.4.1.2.6.33.1.3.2.1.6 | DisplayString | read-only | The Part Number (P/N) and Engineering Change (EC) level for this module and Plant Location. |
| INT moduleAdminState | 1.3.6.1.4.1.2.6.33.1.3.2.1.7 | INTEGER | read-write | The administrative state of this module. |
| INT moduleOperState | 1.3.6.1.4.1.2.6.33.1.3.2.1.8 | INTEGER | read-only | The operational test of this module. |
| CTR moduleErrors | 1.3.6.1.4.1.2.6.33.1.3.2.1.9 | Counter | read-only | The number of errors detected by this module on the traffic from the switch to this module. |
| INT moduleMaxVpc | 1.3.6.1.4.1.2.6.33.1.3.2.1.10 | INTEGER | read-only | The maximum number of VPC supported by this module. The current number of VPC that can be used is the difference between moduleMaxVpc and moduleUsedVpc. |
| INT moduleUsedVpc | 1.3.6.1.4.1.2.6.33.1.3.2.1.11 | INTEGER | read-only | The number of VPCs currently in use for this module. The current number of VPCs that can be used is the difference between moduleMaxVpc and moduleUsedVpc. |
| INT moduleMaxVcc | 1.3.6.1.4.1.2.6.33.1.3.2.1.12 | INTEGER | read-only | The maximum number of VCCs supported by this module. The current number of VCCs that can be used is the difference between moduleMaxVcc and moduleUsedVcc. |
| INT moduleUsedVcc | 1.3.6.1.4.1.2.6.33.1.3.2.1.13 | INTEGER | read-only | The number of VCC currently in use for this module. The current number of VCC that can be used is the difference between moduleMaxVcc and moduleUsedVcc. |
| portTable | 1.3.6.1.4.1.2.6.33.1.3.3 | not-accessible | This table provides the list of ports attached to the ATM switch (ATM ports). These ports belong to ATM modules inserted in slots that are attached to the ATM switch. | |
| portEntry | 1.3.6.1.4.1.2.6.33.1.3.3.1 | not-accessible | Entries of portTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the ATM switch. | |
| INT portSlotIndex | 1.3.6.1.4.1.2.6.33.1.3.3.1.1 | INTEGER | read-only | The slot number of this port's module. |
| INT portIndex | 1.3.6.1.4.1.2.6.33.1.3.3.1.2 | INTEGER | read-only | The port number for this module. |
| IFI portInterface | 1.3.6.1.4.1.2.6.33.1.3.3.1.3 | IfIndex | read-only | The interface number of this port. |
| interfaceTable | 1.3.6.1.4.1.2.6.33.1.3.4 | not-accessible | For each ATM port, this table maps the MIB-II interface index for this port with its physical slot and port numbers. | |
| interfaceEntry | 1.3.6.1.4.1.2.6.33.1.3.4.1 | not-accessible | Entries of the interfaceTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the ATM switch. | |
| IFI interfaceIndex | 1.3.6.1.4.1.2.6.33.1.3.4.1.1 | IfIndex | read-only | The interface number of the port represented by this entry. This is the same number as the index used to represent this interface in the MIB-II interface table. |
| INT interfaceSlot | 1.3.6.1.4.1.2.6.33.1.3.4.1.2 | INTEGER | read-only | The slot number of this ATM port's module. |
| INT interfacePort | 1.3.6.1.4.1.2.6.33.1.3.4.1.3 | INTEGER | read-only | The port number of this ATM port. |
| INT interfaceConnector | 1.3.6.1.4.1.2.6.33.1.3.4.1.4 | INTEGER | read-only | Whether this port is an internal port (on the backplane) or an external connector. |
| INT interfaceAdminState | 1.3.6.1.4.1.2.6.33.1.3.4.1.5 | INTEGER | read-write | The administrative state for this port. When set to disabled, no ATM traffic can pass on this port; all connections (SVC and PVC) are cleared. When set to wrap-reply, this interface is wrapped so that all the traffic received from the attached line is sent back on this line. If the interface state is not changed, it will automatically go back to the disabled state after one minute. |
| INT interfaceOperState | 1.3.6.1.4.1.2.6.33.1.3.4.1.6 | INTEGER | read-only | The operational state for this port: - unknown: the status of this port is unknown (this can be the result of a module in error) - disabled-nosignal: no activity is detected at the physical layer while the port is enabled - disabled-idle:: activity from the remote device attached to this port has been detected by the physical layer. The port is disabled. - failing: an internal hard error has been detected on this port while the port is enabled - no signal: no activity is detected at the physical layer while the port is enabled - idle: activity from the remote device attached to this port has been detected by the physical layer. The port is enabled. - in-service: the remote device successfully acknowledges ILMI polling requests and SVC registration - pvcOnly: the remote device succesfully acknowledges ILMI polling requests but it rejects the ATM prefix registration. Only PVCs are supported. - misConfigured: an SSI to UNI or an SSI to NNI configuration has been detected - wrongNetworkPrefix: the switches on each end of an SSI link have incompatible network prefixes (the 12 first bytes have different values) - wrongNodeNumber: the switches on each end of an SSI link have the same ATM node Numbers. - failing-line: the port is enabled and a invalid signal is detected on the line - disabled-failing: the port is disabled and an anomaly is detected, either internal or external. - wrap-no-signal: the port is internally wrapped so that all the traffic received on the attached line is returned unchanged on the line. No activity is detected at the physical layer. - wrap-idle: the port is internally wrapped so that all the traffic received on the attached line is returned unchanged on the line and a valid signal is detected on the line. - wrap-failing-internal: an internal failure has been detected when the port has been turned into the wrap-reply state. The actual state of the port is undefined. - wrap-failing-line: the port is internally wrapped so that all the traffic received on the attached line is returned unchanged on the line and an invalid signal is detected on the line. When disabled, the port may be in only one of the following states: - unknown, disabled-failing, disabled-nosignal or disabled-idle. |
| INT interfaceAtmAccess | 1.3.6.1.4.1.2.6.33.1.3.4.1.7 | INTEGER | read-write | The type of ATM access offered on this port: - UNI: User Network Interface - SSI: Switch-to-Switch interface - NNI: Network-to-Network interface |
| INT interfaceMediaType | 1.3.6.1.4.1.2.6.33.1.3.4.1.8 | INTEGER | read-only | The type of cable attached to this port. |
| INT interfaceMediaSpeed | 1.3.6.1.4.1.2.6.33.1.3.4.1.9 | INTEGER | read-only | The speed of this interface, in bits per second. |
| CTR interfaceMediaErrors | 1.3.6.1.4.1.2.6.33.1.3.4.1.10 | Counter | read-only | The number of physical layer errors detected on this media such as violation errors and length errors. |
| INT interfaceSubSlot | 1.3.6.1.4.1.2.6.33.1.3.4.1.11 | INTEGER | read-only | When set to 0, this interface (and its physical connector) is directly located on the module identified by the slot number. When set to a non-zero value, this number identifies a feature card of the module that is used by this interface. |
| INT interfaceClocking | 1.3.6.1.4.1.2.6.33.1.3.4.1.12 | INTEGER | read-write | The source of the bit clock used for data transmission. When set to external, the source is the clock received from the line. |
| INT interfaceScrambling | 1.3.6.1.4.1.2.6.33.1.3.4.1.13 | INTEGER | read-write | Whether data scrambling is used when transmitting on this line. Scrambling may be applied at the cell level, at the frame level or at cell and frame level. |
| INT interfaceAvailableBandwidth | 1.3.6.1.4.1.2.6.33.1.3.4.1.14 | INTEGER | read-only | For a UNI or a NNI port: the current bandwidth available for the reserved bandwidth connections on this port. For a SSI port: the current bandwidth available on this port. It is in bits per second. |
| INT interfaceAllocatedBandwidth | 1.3.6.1.4.1.2.6.33.1.3.4.1.15 | INTEGER | read-only | For a UNI or a NNI port: the bandwidth, in bits per second, currently used by the reserved bandwidth connections on this port. For a SSI port: the bandwidth, in bits per second, currently reserved on this port. |
| switchStats | 1.3.6.1.4.1.2.6.33.1.3.5 | |||
| INT switchMonitoring | 1.3.6.1.4.1.2.6.33.1.3.5.1 | INTEGER | read-write | When on, the switch throughput is monitored. When off, the switch thoughput is not monitored. Note that the monitoring decreases the system overall performances. |
| CTR switchAggregateOutCellsEx | 1.3.6.1.4.1.2.6.33.1.3.5.2 | Counter | read-only | The total number of cells transmitted from the switch. Note that this value is the aggregate throughput of all the ports on several minutes. |
| STR receiveTopList | 1.3.6.1.4.1.2.6.33.1.3.5.3 | DisplayString | read-only | The ifindexes of the five most receiving interfaces. The first ifindex given is the one corresponding to the interface which has received the more cells during the last polling interval. All ifIndexes are separated by a blank character. If there are less than 5 interfaces receiving data, there are less than 5 ifindexes listed. |
| STR transmitTopList | 1.3.6.1.4.1.2.6.33.1.3.5.4 | DisplayString | read-only | The ifindexes of the five most transmitting interfaces. The first ifindex given is the one corresponding to the interface which has sent the more cells during the last polling interval. All ifIndexes are separated by a blank character. If there are less than 5 interfaces transmitting data, there are less than 5 ifindexes listed. |
| connections | 1.3.6.1.4.1.2.6.33.1.4 | |||
| vcXConnectTable | 1.3.6.1.4.1.2.6.33.1.4.1 | not-accessible | This table contains the cross-connections set-up in the switch for all existing VCL-based PVCs and SVCs. | |
| vcXConnectEntry | 1.3.6.1.4.1.2.6.33.1.4.1.1 | not-accessible | Entries of vcXConnectTable. | |
| IFI vcXInIndex | 1.3.6.1.4.1.2.6.33.1.4.1.1.1 | IfIndex | read-only | The interface number for this ATM port. |
| INT vcXInVpi | 1.3.6.1.4.1.2.6.33.1.4.1.1.2 | INTEGER | read-only | The VPI value for this connection. |
| INT vcXInVci | 1.3.6.1.4.1.2.6.33.1.4.1.1.3 | INTEGER | read-only | The VCI value for this connection. |
| IFI vcXOutIndex | 1.3.6.1.4.1.2.6.33.1.4.1.1.4 | IfIndex | read-only | The interface number for this ATM port. |
| INT vcXOutVpi | 1.3.6.1.4.1.2.6.33.1.4.1.1.5 | INTEGER | read-only | The VPI value for this connection. |
| INT vcXOutVci | 1.3.6.1.4.1.2.6.33.1.4.1.1.6 | INTEGER | read-only | The VCI value for this connection. |
| INT vcXType | 1.3.6.1.4.1.2.6.33.1.4.1.1.7 | INTEGER | read-only | Whether this cross-connection is part of a unicast or a multicast connection. |
| INT vcXDirection | 1.3.6.1.4.1.2.6.33.1.4.1.1.8 | INTEGER | read-only | Whether this entry identifies this cross-connection in the upstream or downstream flow, as seen from the root. Downstream means that the connection was set up from the in parameters (interface, VPI, VCI) to the out parameters (interface, VPI, VCI). In particular, for a multicast SVC, this means that the call initiator (the root in this case) is on the interface side labeled vcXInIndex. Upstream means that the connection was set up from the out parameters (interface, VPI, VCI) to the in parameters (interface, VPI, VCI). As a result, any cross-connection is modeled in this table as two entries, depending on whether it is seen in the up or down stream. |
| vpXConnectTable | 1.3.6.1.4.1.2.6.33.1.4.2 | not-accessible | This table contains the cross-connections set-up in the switch for all existing VPL-based PVCs and SVCs. | |
| vpXConnectEntry | 1.3.6.1.4.1.2.6.33.1.4.2.1 | not-accessible | Entries of vpXConnectTable. | |
| IFI vpXInIndex | 1.3.6.1.4.1.2.6.33.1.4.2.1.1 | IfIndex | read-only | The interface number for this ATM port. |
| INT vpXInVpi | 1.3.6.1.4.1.2.6.33.1.4.2.1.2 | INTEGER | read-only | The VPI value for this connection. |
| IFI vpXOutIndex | 1.3.6.1.4.1.2.6.33.1.4.2.1.3 | IfIndex | read-only | The interface number for this ATM port. |
| INT vpXOutVpi | 1.3.6.1.4.1.2.6.33.1.4.2.1.4 | INTEGER | read-only | The VPI value for this connection. |
| INT vpXType | 1.3.6.1.4.1.2.6.33.1.4.2.1.5 | INTEGER | read-only | Whether this cross-connection is part of a unicast or a multicast connection. |
| INT vpXDirection | 1.3.6.1.4.1.2.6.33.1.4.2.1.6 | INTEGER | read-only | Whether this entry identifies this cross-connection in the upstream or downstream flow, as seen from the root. Downstream means that the connection was set up from the in parameters (interface, VPI) to the out parameters (interface, VPI). Upstream means that the connection was set up from the out parameters (interface, VPI) to the in parameters (interface, VPI). As a result, any cross-connection is modeled in this table as two entries, depending on whether it is seen in the up or down stream. |
| neighbor | 1.3.6.1.4.1.2.6.33.1.5 | |||
| nbrTable | 1.3.6.1.4.1.2.6.33.1.5.1 | not-accessible | This table contains basic characteristics on adjacent ATM devices attached to this switch. | |
| nbrEntry | 1.3.6.1.4.1.2.6.33.1.5.1.1 | not-accessible | Entries of neighborTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the ATM switch. | |
| IFI localIndex | 1.3.6.1.4.1.2.6.33.1.5.1.1.1 | IfIndex | read-only | The interface number for the port represented by this entry. |
| IP nbrIpAddress1 | 1.3.6.1.4.1.2.6.33.1.5.1.1.2 | IpAddress | read-only | One of the IP addresses of the ATM SNMP agent of the node attached to the port/slot defined by this entry. When not available, 0.0.0.0 is returned. |
| IP nbrIpAddress2 | 1.3.6.1.4.1.2.6.33.1.5.1.1.3 | IpAddress | read-only | One of the IP addresses of the ATM SNMP agent of the node attached to the port/slot defined by this entry. When not available, 0.0.0.0 is returned. |
| ADR nbrAtmAddress | 1.3.6.1.4.1.2.6.33.1.5.1.1.4 | AtmAddress | read-only | The ATM identification of the node attached to the port/slot defined by this entry. When not available, a null string is returned. |
| IFI nbrIndex | 1.3.6.1.4.1.2.6.33.1.5.1.1.5 | IfIndex | read-only | The interface number of the adjacent node to which the connection defined by this entry is attending. When not available, 0 is returned. |
| STR nbrDescriptor | 1.3.6.1.4.1.2.6.33.1.5.1.1.6 | DisplayString | read-only | The value of the MIB-II sysDescr as reported by the device attached to this port. When not available, a null string is returned. |
| OID nbrOid | 1.3.6.1.4.1.2.6.33.1.5.1.1.7 | OBJECT IDENTIFIER | read-only | The value of the MIB-II sysOID as reported by the device attached to this port. When not available, a null string is returned. |
| STR nbrName | 1.3.6.1.4.1.2.6.33.1.5.1.1.8 | DisplayString | read-only | The value of the MIB-II sysName as reported by the device attached to this port. When not available, a null string is returned. |
| STR nbrLocation | 1.3.6.1.4.1.2.6.33.1.5.1.1.9 | DisplayString | read-only | The value of the MIB-II sysLocation as reported by the device attached to this port. When not available, a null string is returned. |
| INT trunkId | 1.3.6.1.4.1.2.6.33.1.5.1.1.10 | INTEGER | read-only | The internal identifier for this trunk. Set to 0 if not a trunk. |
| tftp | 1.3.6.1.4.1.2.6.33.1.6 | |||
| INT transferControl | 1.3.6.1.4.1.2.6.33.1.6.1 | INTEGER | read-write | A file transfer is initiated through a start command. |
| DAT transferDate | 1.3.6.1.4.1.2.6.33.1.6.2 | DateAndTime | read-only | The date and time of the last transfer. |
| IP serverIpAddress | 1.3.6.1.4.1.2.6.33.1.6.3 | IpAddress | read-write | The IP address of the server used for file transfer. |
| STR fileName | 1.3.6.1.4.1.2.6.33.1.6.4 | DisplayString | read-write | The name of the file to transfer. |
| INT fileType | 1.3.6.1.4.1.2.6.33.1.6.5 | INTEGER | read-write | The type of file to transfer. Boot and operational codes can only be dowlnoaded. Logs, traces and dumps can only be uploaded. |
| INT fileTarget | 1.3.6.1.4.1.2.6.33.1.6.6 | INTEGER | read-write | The module target to which the transfer applies. When set to 0, the transfer applies to the agent itself. |
| INT transferResult | 1.3.6.1.4.1.2.6.33.1.6.7 | INTEGER | read-only | The result of the latest file transfer. When one of the TFTP variables is modified, this variable is reset to not-initialized. |
| service | 1.3.6.1.4.1.2.6.33.1.7 | |||
| traces | 1.3.6.1.4.1.2.6.33.1.7.1 | |||
| INT sysTrace | 1.3.6.1.4.1.2.6.33.1.7.1.1 | INTEGER | read-write | When on, the hub general trace facility is started. Messages are stored in the hub in a file that can be retrieved through TFTP. When off, the general trace facility is stopped and messages are no longer logged. |
| INT trsTrace | 1.3.6.1.4.1.2.6.33.1.7.1.2 | INTEGER | read-write | When on, the Topology and Routing Selection trace is started. Messages are stored in the hub in a file that can be retrieved through TFTP. When off, the control point trace facility is stopped and messages are no longer logged. |
| dumps | 1.3.6.1.4.1.2.6.33.1.7.2 | |||
| INT trsDump | 1.3.6.1.4.1.2.6.33.1.7.2.2 | INTEGER | read-write | When start is selected, a dump of the Topology and Route Services component is taken. The dump is stored in the hub in a file that can be retrieved through TFTP. |
| swap | 1.3.6.1.4.1.2.6.33.1.7.3 | |||
| INT swapControl | 1.3.6.1.4.1.2.6.33.1.7.3.1 | INTEGER | read-write | When swap is selected, the backup microcode image is checked and, if valid, activated. The previously active microcode image becomes the backup image. The atm subsystem is reset. |
| INT swapResult | 1.3.6.1.4.1.2.6.33.1.7.3.2 | INTEGER | read-only | The result of the latest microcode swap. When an operational code image is downloaded or when the system is reset, swapControl becomes not-initialized. |
| atmSvc | 1.3.6.1.4.1.2.6.33.1.9 | |||
| atmQ2931 | 1.3.6.1.4.1.2.6.33.1.9.1 | |||
| atmQ2931ConfTable | 1.3.6.1.4.1.2.6.33.1.9.1.1 | not-accessible | This table contains basic information on the Q2931 protocol for each signalling link defined per port. Usually, there is only one signalling channel per interface and thus one Q2931 protocol definition entry per interface. | |
| atmQ2931ConfEntry | 1.3.6.1.4.1.2.6.33.1.9.1.1.1 | not-accessible | Entries of atmQ2931ConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface by the VPI and VCI values allocated to it. | |
| IFI atmQ2931ConfIndex | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.1 | IfIndex | read-only | The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry. |
| INT atmQ2931SiVpi | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.2 | INTEGER | read-only | The Vpi value which, with the Vci value specified in atmQ2931SiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| INT atmQ2931SiVci | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.3 | INTEGER | read-only | The Vci value which, with the Vpi value specified in atmQ2931SiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| INT atmQ2931T303 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.4 | INTEGER | read-only | T303 timer as defined in the ATM UNI Specification. |
| INT atmQ2931T308 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.5 | INTEGER | read-only | T308 timer as defined in the ATM UNI Specification. |
| INT atmQ2931T309 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.6 | INTEGER | read-only | T309 timer as defined in the ATM UNI Specification. |
| INT atmQ2931T310 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.7 | INTEGER | read-only | T310 timer as defined in the ATM UNI Specification. |
| INT atmQ2931T316 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.8 | INTEGER | read-only | T316 timer as defined in the ATM UNI Specification. |
| INT atmQ2931T317 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.9 | INTEGER | read-only | T317 timer as defined in the ATM UNI Specification. |
| INT atmQ2931T322 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.10 | INTEGER | read-only | T322 timer as defined in the ATM UNI Specification. |
| INT atmQ2931T398 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.11 | INTEGER | read-only | T398 timer as defined in the ATM UNI Specification. |
| INT atmQ2931T399 | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.12 | INTEGER | read-only | T399 timer as defined in the ATM UNI Specification. |
| INT atmQ2931SetupRetry | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.13 | INTEGER | read-only | Number of set-up retries as defined in the ATM UNI Specification. |
| INT atmQ2931ReleaseRetry | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.14 | INTEGER | read-only | Number of release retries as defined in the ATM UNI Specification. |
| INT atmQ2931RestartRetry | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.15 | INTEGER | read-only | Number of restart retries as defined in the ATM UNI Specification. |
| INT atmQ2931StatusRetry | 1.3.6.1.4.1.2.6.33.1.9.1.1.1.16 | INTEGER | read-only | Number of status retries as defined in the ATM UNI Specification. |
| atmQ2931StatsTable | 1.3.6.1.4.1.2.6.33.1.9.1.2 | not-accessible | This table contains statistics for the Q2931 protocol. | |
| atmQ2931StatsEntry | 1.3.6.1.4.1.2.6.33.1.9.1.2.1 | not-accessible | Entries of atmQ2931ConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface by the VPI and VCI values allocated to it. | |
| IFI atmQ2931StatsIndex | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.1 | IfIndex | read-only | The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry. |
| INT atmQ2931StatsVpi | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.2 | INTEGER | read-only | The Vpi value which, with the Vci value specified in atmQ2931StatsVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| INT atmQ2931StatsVci | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.3 | INTEGER | read-only | The Vci value which, with the Vpi value specified in atmQ2931StatsVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| CTR atmQ2931OutCallAttempts | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.4 | Counter | read-only | This is the number of outgoing call attempts on this interface, including accepted as well as rejected calls. |
| GAU atmQ2931OutCallInProgess | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.5 | Gauge | read-only | This is the current number of outgoing calls in progress on this interface. |
| CTR atmQ2931OutCallFailures | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.6 | Counter | read-only | This is the number of outgoing calls that were cleared for a reason other than a DTE or operator initiated action. |
| CTR atmQ2931InCallAttempts | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.7 | Counter | read-only | This is the number of incoming call attempts on this interface, including accepted as well as rejected calls. |
| GAU atmQ2931InCallInProgress | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.8 | Gauge | read-only | This is the current number of incoming calls in progress on this interface. |
| CTR atmQ2931InCallFailures | 1.3.6.1.4.1.2.6.33.1.9.1.2.1.9 | Counter | read-only | This is the number of calls that were rejected by the receiver. |
| atmSvcTable | 1.3.6.1.4.1.2.6.33.1.9.1.3 | not-accessible | This table contains basic information for each active Switched Virtual Connection (SVC). | |
| atmSvcEntry | 1.3.6.1.4.1.2.6.33.1.9.1.3.1 | not-accessible | Entries of atmSvcTable. Each entry uniquely defines two end-points of an SVC. In the case of a multicast SVC, each entry is defined by the association of the root and one party. | |
| IFI atmSvcInterfaceIndex | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.1 | IfIndex | read-only | The ifIndex value of the ATM interface used by this SVC. |
| INT atmSvcSiVpi | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.2 | INTEGER | read-only | The Vpi value which, with the Vci value specified in atmQ2931SiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| INT atmSvcSiVci | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.3 | INTEGER | read-only | The Vci value which, with the Vpi value specified in atmQ2931SiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| INT atmSvcCallReference | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.4 | INTEGER | read-only | The Q2931 call reference value used for this SVC. |
| INT atmSvcEndPointReference | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.5 | INTEGER | read-only | One of the Q2931 end point reference values used by this SVC. In a unicast SVC, there is only one entry for this SVC in the table. In a multicast SVC, there is one entry per party. |
| ADR atmSvcCallingNumber | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.6 | AtmAddress | read-only | The calling number carried in the calling party number information element of the call set-up message. |
| ADR atmSvcCalledNumber | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.7 | AtmAddress | read-only | The called number carried in the called party number information element of the call set-up message. |
| INT atmSvcClear | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.8 | INTEGER | read-write | This variable allows a network manager to clear this SVC. When this SVC is cleared (either by the manager using this variable or by one of the parties), the entry is deleted from this table and another entry is created in the atmSvcClearTable. |
| DAT atmSvcCreationTime | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.9 | DateAndTime | read-only | The date and time this call was placed. |
| INT atmSvcVpi | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.10 | INTEGER | read-only | The VPI value used by this SVC for this interface. |
| INT atmSvcVci | 1.3.6.1.4.1.2.6.33.1.9.1.3.1.11 | INTEGER | read-only | The VCI value used by this SVC for this interface. |
| INT atmSvcLogSize | 1.3.6.1.4.1.2.6.33.1.9.1.4 | INTEGER | read-only | The maximum number of entries supported by this local SNMP agent. When this value is exceeded, the entries are wrapped. |
| INT atmSvcLogLevel | 1.3.6.1.4.1.2.6.33.1.9.1.5 | INTEGER | read-write | The maximum number of entries that can be written in the atmSvcLogTable before a trap is generated. When this number is reached, an svcLogOverflow trap is generated. When set to 0, no trap is generated. |
| atmSvcLogTable | 1.3.6.1.4.1.2.6.33.1.9.1.6 | not-accessible | This table contains a list of the latest Switched Virtual Connection (SVC) that were completed on this ATM node. An SVC is completed when it has been torn down at the originator's request (normal completion) or by the network operator (forced tear down), or when it has been rejected or cleared by the network (exceptional condition). | |
| atmSvcLogEntry | 1.3.6.1.4.1.2.6.33.1.9.1.6.1 | not-accessible | Entries of atmSvcLogTable. | |
| INT atmSvcLogIndex | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.1 | INTEGER | read-only | An identification value for this entry, assigned by the local SNMP agent. This value is assigned for each new SVC call or add-party request. This index is allocated in a decreasing order, so that a get-next request on the table allows to retrieve the latest calls first. |
| IFI atmSvcLogInterfaceIndex | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.2 | IfIndex | read-only | The ifIndex value of the ATM interface used by this SVC. |
| ADR atmSvcLogCallingNumber | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.3 | AtmAddress | read-only | The calling number carried in the calling party number information element of the call set-up message. |
| ADR atmSvcLogCalledNumber | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.4 | AtmAddress | read-only | The called number carried in the called party number information element of the call set-up message. |
| DAT atmSvcLogCreationTime | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.5 | DateAndTime | read-only | The date and time this call was placed. |
| DAT atmSvcLogTime | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.6 | DateAndTime | read-only | The date and time this call was cleared. |
| INT atmSvcLogClearCause | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.7 | INTEGER | read-only | The cause of the clearing of this SVC. |
| INT atmSvcLogForwardQOS | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.8 | INTEGER | read-only | The forward Quality Of Service requested for this call. |
| INT atmSvcLogBackwardQOS | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.9 | INTEGER | read-only | The backward Quality Of Service requested for this call. |
| INT atmSvcLogForwardBW | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.10 | INTEGER | read-only | The forward bandwidth requested for this call. |
| INT atmSvcLogBackwardBW | 1.3.6.1.4.1.2.6.33.1.9.1.6.1.11 | INTEGER | read-only | The backward bandwidth requested for this call. |
| atmSaal | 1.3.6.1.4.1.2.6.33.1.9.2 | |||
| atmSaalConfTable | 1.3.6.1.4.1.2.6.33.1.9.2.1 | not-accessible | This table contains basic information on the SAAL protocol for each signalling link defined per port. Usually, there is only one signalling channel per interface and thus one SAAL protocol definition entry per interface. | |
| atmSaalConfEntry | 1.3.6.1.4.1.2.6.33.1.9.2.1.1 | not-accessible | Entries of atmSaalConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface by the VPI and VCI values allocated to it. | |
| IFI atmSaalConfIndex | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.1 | IfIndex | read-only | The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry. |
| INT atmSaalConfSiVpi | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.2 | INTEGER | read-only | The Vpi value which, with the Vci value specified in atmSaalConfSiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| INT atmSaalConfSiVci | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.3 | INTEGER | read-only | The Vci value which, with the Vpi value specified in atmSaalConfSiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| INT atmSaalState | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.4 | INTEGER | read-only | The state of the SAAL for this interface as defined in the Q.2110 Specification, Chapter 7.3. |
| INT atmSaalTimerPoll | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.5 | INTEGER | read-only | Timer_POLL as defined in the Q.2110 Specification. This timer is running in the active phase to assure that the peer receiver is polled often enough to return its status. |
| INT atmSaalTimerKeepAlive | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.6 | INTEGER | read-only | Timer_KEEP-ALIVE as defined in the Q.2110 Specification. This timer is started when entering the transient phase. |
| INT atmSaalTimerNoResponse | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.7 | INTEGER | read-only | Timer_NO-RESPONSE as defined in the Q.2110 Specification. This timer indicates the maximum time interval during which at least one STAT PDU needs to be received. |
| INT atmSaalTimerCC | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.8 | INTEGER | read-only | Timer_CC as defined in the Q.2110 Specification. Transmission of PDUs is protected by this timer during establishment and release of a connection and during resynchronization or recovery. |
| INT atmSaalTimerIdle | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.9 | INTEGER | read-only | Timer_IDLE as defined in the Q.2110 Specification. This timer is started upon receipt of a STAT PDU when entering the idle phase (no POLL PDUs sent). |
| INT atmSaalMaxCC | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.10 | INTEGER | read-only | MaxCC as defined in the Q.2110 Specification. This is the maximum value for the state variable VT(CC), corresponding to the maximum number of transmissions of a BGN, END, ER or RS PDU. |
| INT atmSaalMaxPD | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.11 | INTEGER | read-only | MaxPD as defined in the Q.2110 Specification. This is the maximum iacceptable value for the state variable VT(PD) before sending a POLL PDU and resetting VT(PD) to zero. This parameter is an upper limit for counter VT(PD) that sends a POLL PDU after every (MaxPD) SD PDUs. |
| INT atmSaalMaxStat | 1.3.6.1.4.1.2.6.33.1.9.2.1.1.12 | INTEGER | read-only | MaxSTAT as defined in the Q.2110 Specification. This is the maximum number of list elements placed in a STAT PDU. |
| atmSaalStatsTable | 1.3.6.1.4.1.2.6.33.1.9.2.2 | not-accessible | This table contains statistics for the SAAL protocol, for outgoing calls only. | |
| atmSaalStatsEntry | 1.3.6.1.4.1.2.6.33.1.9.2.2.1 | not-accessible | Entries of atmSaalConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface by the VPI and VCI values allocated to it. | |
| IFI atmSaalStatsIndex | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.1 | IfIndex | read-only | The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry. |
| INT atmSaalStatsSiVpi | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.2 | INTEGER | read-only | The Vpi value which, with the Vci value specified in atmSaalStatsSiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| INT atmSaalStatsSiVci | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.3 | INTEGER | read-only | The Vci value which, with the Vpi value specified in atmSaalStatsSiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5. |
| CTR atmSaalUnexpectPdus | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.4 | Counter | read-only | Error conditions A to M, as defined in the Q.2110 Specification. This is the number of received unsolicited or or inappropriate PDUs. |
| CTR atmSaalUnsuccessPdus | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.5 | Counter | read-only | Error condition O as defined in the Q.2110 Specification. This is the number of failing retries. |
| CTR atmSaalFailedEstablishment | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.6 | Counter | read-only | Error condition P as defined in the Q.2110 Specification. This is the number of failing polls. |
| CTR atmSaalSequenceGap | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.7 | Counter | read-only | The number of times sequence gaps were detected by the peer entity. |
| CTR atmSaalGapNumbers | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.8 | Counter | read-only | The number of times frames were re-transmitted due to sequence gaps detected by the peer entity. |
| CTR atmSaalOtherListErrors | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.9 | Counter | read-only | Error conditions Q to V as defined in the Q.2110 Specification. |
| CTR atmSaalLackOfCredit | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.10 | Counter | read-only | Error condition W as defined in the Q.2110 Specification. This is the number of times that transmission was not permitted by the peer entity due to a lack of credit. |
| CTR atmSaalCreditObtained | 1.3.6.1.4.1.2.6.33.1.9.2.2.1.11 | Counter | read-only | Error condition X as defined in the Q.2110 Specification. This is the number of times that credit was obtained from the peer entity to allow transmission. |
| atmPvc | 1.3.6.1.4.1.2.6.33.1.10 | |||
| INT atmPvcHandler | 1.3.6.1.4.1.2.6.33.1.10.1 | INTEGER | read-only | The status of the PVC handler in the switch. When no more memory is available, the creation of new PVCs is rejected with a generic Error sense code. |
| atmPvcTable | 1.3.6.1.4.1.2.6.33.1.10.2 | not-accessible | This table lists all PVCs defined per interface. There is only one entry in this table per PVC (point-to-point or point-to-multipoint PVC). | |
| atmPvcEntry | 1.3.6.1.4.1.2.6.33.1.10.2.1 | not-accessible | Entries of atmPvcTable. Policing parameters are those requested when creating the PVC. The actual values used by the network to satisfy these requirements may slightly differ. These values are attached to virtual links and are available in virtual link tables, such as the RFC-1695 VPL/VCL tables. | |
| IFI atmPvcIndex | 1.3.6.1.4.1.2.6.33.1.10.2.1.1 | IfIndex | read-only | The ifIndex value of the ATM interface used by this PVC. |
| INT atmPvcIdentifier | 1.3.6.1.4.1.2.6.33.1.10.2.1.2 | INTEGER | read-only | A value used to uniquely identify this PVC on this interface. To create a new PVC on a given interface, an unused PVC identifier must be found. |
| INT atmPvcRowStatus | 1.3.6.1.4.1.2.6.33.1.10.2.1.3 | INTEGER | read-write | States values: active: the PVC is operational notInService: the PVC is failing notReady: values are missing to be able to activate this PVC Actions: active: this requests to re-start a failing PVC (which status was notInService) destroy: this requests to delete a PVC createAndWait: this requests to create a PVC To create a new PVC, this variable must be set to createAndWait with an index where: - atmPvcIndex is the number of the interface from where the PVC is created - atmPvcIdentifier is an unused PVC identifier for this interface To activate a PVC, this variable must be set to active. Default values are provided for all attributes except for the atmPvcEpRemIndex. If this attribute is not set, the PVC will remain in the notReady state. To delete a point-to-point PVC, this variable must be set to destroy. |
| INT atmPvcType | 1.3.6.1.4.1.2.6.33.1.10.2.1.4 | INTEGER | read-write | A unicast PVC is defined between two endpoints, using either a VP or a VC connection. |
| INT atmPvcEndPoint | 1.3.6.1.4.1.2.6.33.1.10.2.1.5 | INTEGER | read-only | The end-point where the PVC is created is identified as the primary or root end-point. the other end-point is the identified as the secondary or leaf end-point. |
| INT atmPvcVpi | 1.3.6.1.4.1.2.6.33.1.10.2.1.6 | INTEGER | read-write | The VPI value assigned to this PVC at the origin. A value of 65536 means that no value has been specified by the operator. If no value has been specified, the VPI value is then automatically allocated by the agent when activating the PVC. |
| INT atmPvcVci | 1.3.6.1.4.1.2.6.33.1.10.2.1.7 | INTEGER | read-write | The VCI value assigned to this PVC at the origin. For VP-type PVC, this value is not applicable and is set to 0. A value of 65536 means that no value has been specified by the operator. If no value has been specified, the VCI value is then automatically allocated by the agent when activating the PVC. |
| INT atmPvcBackwardQos | 1.3.6.1.4.1.2.6.33.1.10.2.1.8 | INTEGER | read-write | The QOS requested for this PVC to the originator. |
| INT atmPvcForwardQos | 1.3.6.1.4.1.2.6.33.1.10.2.1.9 | INTEGER | read-write | The QOS requested for this PVC from the originator. |
| OID atmPvcBackwardType | 1.3.6.1.4.1.2.6.33.1.10.2.1.10 | OBJECT IDENTIFIER | read-write | The first parameter used to define the policy requested for this PVC. |
| OID atmPvcForwardType | 1.3.6.1.4.1.2.6.33.1.10.2.1.11 | OBJECT IDENTIFIER | read-write | The type of policy requested for this PVC. |
| INT atmPvcBackwardParm1 | 1.3.6.1.4.1.2.6.33.1.10.2.1.12 | INTEGER | read-write | The fourth parameter used to define the policy requested for this PVC. |
| INT atmPvcForwardParm1 | 1.3.6.1.4.1.2.6.33.1.10.2.1.13 | INTEGER | read-write | The third parameter used to define the policy requested for this PVC. |
| atmPvcEpTable | 1.3.6.1.4.1.2.6.33.1.10.3 | not-accessible | This table lists the characteristics of the remote end-points of defined PVCs. There is one entry for each PVC defined in the atmPvcTable. | |
| atmPvcEpEntry | 1.3.6.1.4.1.2.6.33.1.10.3.1 | not-accessible | Entries of atmPvcEpTable. One entry is automatically created by the agent when a PVC is created in the PVC Table. No additional entry can be created in this table if the PVC is defined as point-to-point in the PVC table. | |
| IFI atmPvcEpIndex | 1.3.6.1.4.1.2.6.33.1.10.3.1.1 | IfIndex | read-only | The ifIndex value of the ATM interface used by this PVC. |
| INT atmPvcEpIdentifier | 1.3.6.1.4.1.2.6.33.1.10.3.1.2 | INTEGER | read-only | A value used to uniquely identify this PVC on this interface. This is the same identifier as the one used in the atmPvcTable to identify the PVC that this end-point belongs to. |
| INT atmPvcEpParty | 1.3.6.1.4.1.2.6.33.1.10.3.1.3 | INTEGER | read-only | A value used to uniquely identify a remote end-point of a PVC, when associated with an interface index and a PVC identifier. For a point-to-point PVC, this value is always set to 0. |
| INT atmPvcEpRowStatus | 1.3.6.1.4.1.2.6.33.1.10.3.1.4 | INTEGER | read-write | States values: active: the PVC is operational notInService: the PVC is failing notReady: values are missing to be able to activate this PVC Actions: active: this requests to re-start a failing unicast PVC (status was notInService) destroy: this requests to delete a unicast PVC. |
| INT atmPvcEpStatusCause | 1.3.6.1.4.1.2.6.33.1.10.3.1.5 | INTEGER | read-only | A detailed cause for the current PVC status. |
| NET atmPvcEpRemAddress | 1.3.6.1.4.1.2.6.33.1.10.3.1.6 | NetPrefix | read-write | The ATM address of the remote ATM switch where the PVC ends. If none is specified, the ATM address of the target switch (local) is used and the PVC is confined to the target switch (local switch). |
| IFI atmPvcEpRemIndex | 1.3.6.1.4.1.2.6.33.1.10.3.1.7 | IfIndex | read-write | The ifindex value used at the remote end to identify the interface where the PVC ends. This entry will remain in the notReady state until this attribute is set (and the atmPvcRowStatus is set to active). |
| INT atmPvcEpRemVpi | 1.3.6.1.4.1.2.6.33.1.10.3.1.8 | INTEGER | read-write | The VPI value assigned to this PVC at the destination (remote end). If left at 65536 (default value), one value is automatically allocated by the agent. |
| INT atmPvcEpRemVci | 1.3.6.1.4.1.2.6.33.1.10.3.1.9 | INTEGER | read-write | The VCI value assigned to this PVC at the destination. For VP-type PVC, this value is not applicable and is set to 0. If left at 65536 (default value), one value is automatically allocated by the agent (for VC only). |
| DAT atmPvcEpLastActive | 1.3.6.1.4.1.2.6.33.1.10.3.1.10 | DateAndTime | read-only | The date and time of the latest PVC activation. |
| INT atmPvcEpQ2931Cause | 1.3.6.1.4.1.2.6.33.1.10.3.1.11 | INTEGER | read-only | The cause of the failure as defined by Q2931. |
| CTR atmPvcEpFailures | 1.3.6.1.4.1.2.6.33.1.10.3.1.12 | Counter | read-only | The number of times this PVC failed. |
| agents | 1.3.6.1.4.1.2.6.33.2 | |||
| ibm8260 | 1.3.6.1.4.1.2.6.33.2.1 | |||
| gatwick | 1.3.6.1.4.1.2.6.33.2.2 | |||
| admin | 1.3.6.1.4.1.2.6.33.3 | |||
| testType | 1.3.6.1.4.1.2.6.33.3.1 | |||
| internalLoopback | 1.3.6.1.4.1.2.6.33.3.1.1 | |||
| externalLoopback | 1.3.6.1.4.1.2.6.33.3.1.2 |
RFC description
Manages ATM switching fabric configuration, statistics, and network interface status for IBM ATM switches.
Start monitoring IBM ATM switching node equipment (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.