ATM-SWITCHING-NODE-MIB :: sysTrace

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ATM-SWITCHING-NODE-MIB › sysTrace

sysTrace

Module: ATM-SWITCHING-NODE-MIB

OID (symbolic): ATM-SWITCHING-NODE-MIB::sysTrace

OID (numeric): 1.3.6.1.4.1.2.6.33.1.7.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When on, the hub general trace facility is started. Messages are stored in the hub in a file that can be retrieved through TFTP. When off, the general trace facility is stopped and messages are no longer logged.

What is sysTrace?

Turns the hub's general trace facility on or off; when enabled, trace messages are logged to a file retrievable via TFTP.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.6.33.1.7.1.1
snmpwalk -v2c -c public <target> ATM-SWITCHING-NODE-MIB::sysTrace

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2.6.33.1.7.1.1.1
snmpget -v2c -c public <target> ATM-SWITCHING-NODE-MIB::sysTrace.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2.6.33.1.7.1.1.1 i <value>

Start monitoring IBM ATM switching node equipment (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ATM-SWITCHING-NODE-MIB::sysTrace OID value, configure state conditions and alerts, and monitor any IBM ATM switching node equipment (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2ibmATM-ADAPTER-MIB
1.3.6.1.4.1.2.6ibmProdATM-ADAPTER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2.6.33atmSwATM-SWITCHING-NODE-MIB
1.3.6.1.4.1.2.6.33.1nodeATM-SWITCHING-NODE-MIB
1.3.6.1.4.1.2.6.33.1.7serviceATM-SWITCHING-NODE-MIB
1.3.6.1.4.1.2.6.33.1.7.1tracesATM-SWITCHING-NODE-MIB
1.3.6.1.4.1.2.6.33.1.7.1.1sysTraceATM-SWITCHING-NODE-MIB