All MIBs › ZYXEL-SESCOMMON-MIB
Category: ZyXEL DSL Access
Description:
Defines common ZyXEL SES platform objects for shared configuration across security and edge switch series.
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| Counter | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString | |
| ifIndex |
From SNMPv2-TC
| RowStatus |
From ZYXEL-MIB
| sesSeriesCommon |
What Is ZYXEL-SESCOMMON-MIB?
This MIB belongs to ZyXEL's SES (Switch/Security Edge Series or similar shared) platform family and defines common object definitions shared across multiple ZyXEL security and edge-switch product lines, acting as a base/utility MIB rather than a feature-specific one. Based on its role as a 'common' module, it likely exposes shared textual conventions, common status/identity objects, or base tables that other ZyXEL SES-specific MIBs import and extend, though the source excerpt did not include a MODULE-IDENTITY description or object list. Its monitoring value is therefore indirect: it underpins consistent representation of common status or hardware/software identity fields (such as device type or shared severity/status enumerations) used by other MIBs in the SES family. As a shared/common module, it is inherently a dependency for other ZyXEL SES-series MIBs that import its definitions rather than standing alone. It is typically present alongside other ZyXEL security and edge switch MIBs wherever those product lines are deployed, functioning as supporting infrastructure rather than a directly polled monitoring target. Engineers can download the ZYXEL-SESCOMMON-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ZYXEL-SESCOMMON-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- shared status/identity conventions (definitions vary by importing MIB)
- common enumerations used by other ZyXEL SES MIBs
Supported Devices
- ZyXEL SES series switch/security appliance
Monitoring Examples
Because no sample objects or module description were available for this MIB, a network engineer would typically inspect the compiled MIB file directly to identify which shared textual conventions or common tables it defines before determining what, if anything, to poll from it directly. In practice, common MIBs like this are usually referenced via IMPORTS by other ZyXEL SES-series MIBs (e.g., specific switch or security appliance MIBs) rather than polled on their own. Confirming its exact object definitions against the actual MIB source is recommended before including it in a monitoring template.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| sesLineStatusTable | 1.3.6.1.4.1.890.1.5.5.1.1 | not-accessible | This table contains the current status of SHDSL line. These managed objects are supported by ZyXEL SDSL access switches. | |
| sesLineStatusEntry | 1.3.6.1.4.1.890.1.5.5.1.1.1 | not-accessible | An zyxelLineStatusEntry containing the specific status for a particular SHDSL interface. | |
| TIK sesLineUptime | 1.3.6.1.4.1.890.1.5.5.1.1.1.1 | TimeTicks | read-only | The time duration since the connection between STU-C STU-R is last setup. |
| CTR sesLineLinkDown | 1.3.6.1.4.1.890.1.5.5.1.1.1.2 | Counter | read-only | The number of link down since the SAM-1008 was last restarted. |
| CTR sesLineNMdefect | 1.3.6.1.4.1.890.1.5.5.1.1.1.3 | Counter | read-only | Count of noise margin defects |
| CTR sesLineHECdefect | 1.3.6.1.4.1.890.1.5.5.1.1.1.4 | Counter | read-only | Count of HEC defects |
| CTR sesLineTxPackets | 1.3.6.1.4.1.890.1.5.5.1.1.1.5 | Counter | read-only | Count of line Tx packets |
| CTR sesLineRxPackets | 1.3.6.1.4.1.890.1.5.5.1.1.1.6 | Counter | read-only | Count of line Rx packets |
| CTR sesLineTxFrames | 1.3.6.1.4.1.890.1.5.5.1.1.1.7 | Counter | read-only | Count of line Tx frames |
| CTR sesLineRxFrames | 1.3.6.1.4.1.890.1.5.5.1.1.1.8 | Counter | read-only | Count of line Rx frames |
| CTR sesLineTxCells | 1.3.6.1.4.1.890.1.5.5.1.1.1.9 | Counter | read-only | Count of line Tx cells |
| CTR sesLineRxCells | 1.3.6.1.4.1.890.1.5.5.1.1.1.10 | Counter | read-only | Count of line Rx cells |
| INT sesMaxNumOfProfiles | 1.3.6.1.4.1.890.1.5.5.1.2 | INTEGER | read-only | The maximum number of SHDSL profiles which the system supports. |
| sesLineConfTable | 1.3.6.1.4.1.890.1.5.5.1.3 | not-accessible | This table includes common attributes describing the SHDSL line. | |
| sesLineConfEntry | 1.3.6.1.4.1.890.1.5.5.1.3.1 | not-accessible | An entry in sesLineConfTable. | |
| INT sesLineConfEncap | 1.3.6.1.4.1.890.1.5.5.1.3.1.1 | INTEGER | read-write | The encapsulation of the SHDSL line. |
| INT sesLineConfVpi | 1.3.6.1.4.1.890.1.5.5.1.3.1.2 | INTEGER | read-write | The VPI of the SHDSL line. |
| INT sesLineConfVci | 1.3.6.1.4.1.890.1.5.5.1.3.1.3 | INTEGER | read-write | The VCI of the SHDSL line. |
| INT sesMaxNumOfPortBondings | 1.3.6.1.4.1.890.1.5.5.1.4 | INTEGER | read-only | The maximum number of port bondings which the system supports. |
| sesPortBondingTable | 1.3.6.1.4.1.890.1.5.5.1.5 | not-accessible | This table includes the configuration of port bonding. | |
| sesPortBondingEntry | 1.3.6.1.4.1.890.1.5.5.1.5.1 | not-accessible | An entry in sesPortBondingTable. | |
| STR sesPortBondingName | 1.3.6.1.4.1.890.1.5.5.1.5.1.1 | DisplayString | not-accessible | This object is used by the port bonding table in order to identify a row of this table. |
| INT sesPortBondingNumOfMembers | 1.3.6.1.4.1.890.1.5.5.1.5.1.2 | INTEGER | read-write | The number of members included in the bonding entry. |
| OCT sesPortBondingMemberList | 1.3.6.1.4.1.890.1.5.5.1.5.1.3 | OCTET STRING | read-write | The member list is included in the bonding entry. Each member is identified by two octets. In the 2-wire mode, each member stands for a single port. In the 4-wire mode, each member stands for a 4-wire group. In the 8-wire mode, each member stands for a 8-wire group. |
| INT sesPortBondingMode | 1.3.6.1.4.1.890.1.5.5.1.5.1.4 | INTEGER | read-write | The mode in which the bonding entry is. twoWireC mode stands for 2-wire plus stu-c, and so on. |
| ROW sesPortBondingRowStatus | 1.3.6.1.4.1.890.1.5.5.1.5.1.5 | RowStatus | read-write | To delete an existing row in this table. |
| sesNwireTable | 1.3.6.1.4.1.890.1.5.5.1.6 | not-accessible | This table includes N-wire configurations. | |
| sesNwireEntry | 1.3.6.1.4.1.890.1.5.5.1.6.1 | not-accessible | An entry in sesNwireTable. | |
| STR sesNwireGroupName | 1.3.6.1.4.1.890.1.5.5.1.6.1.1 | DisplayString | not-accessible | This object is used by the N-wire table in order to identify a row of this table. |
| OCT sesNwireGroupNumber | 1.3.6.1.4.1.890.1.5.5.1.6.1.2 | OCTET STRING | read-write | The group number included in the N-wire entry. Each group is identified by two octets. In the 4-wire mode: Group1 stands for Port1 and Port2 Group2 stands for Port3 and Port4 Group3 stands for Port5 and Port6 Group4 stands for Port7 and Port8 In the 8-wire mode: Group1 stands for Port1, Port2, Port3 and Port4 Group2 stands for Port5, Port6, Port7 and Port8 |
| INT sesNwireMode | 1.3.6.1.4.1.890.1.5.5.1.6.1.3 | INTEGER | read-write | The mode in which the N-wire entry is. fourWireC mode stands for 4-wire plus stu-c, and so on. |
| ROW sesNwireRowStatus | 1.3.6.1.4.1.890.1.5.5.1.6.1.4 | RowStatus | read-write | To delete an existing row in this table. |
RFC description
Zyxel vendor-private MIB defining common session management objects for Zyxel network appliances and security devices.