All MIBs › X25-MIB
Category: Legacy and Miscellaneous
Description: Manages X.25 packet-switched network interface configuration, virtual circuit state, and packet-layer statistics.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is X25-MIB?
X25-MIB is a vendor-neutral IETF standards-track MIB for managing X.25 packet-switched network interfaces, a legacy WAN protocol used before frame relay and IP largely replaced it. It exposes configuration for the Packet Level Entity (PLE), channel assignments, and packet-layer statistics -- effectively both the administratively configured settings and the values actually in use on the interface. Its monitoring value centers on verifying interface configuration and traffic/error statistics at the X.25 packet layer, letting an operator confirm the link's virtual circuits are configured and functioning as intended and spot packet-layer errors or mismatches between configured and operational values. As an interface-layer MIB it typically works alongside the standard IF-MIB, since X.25 PLEs are represented as interfaces in ifTable. It would be found on legacy WAN routers, X.25 packet switches, and PADs (packet assemblers/disassemblers) still operating in older telecom or banking/financial networks. Engineers can download the X25-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in X25-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- vendor-neutral, standards-based MIB, not tied to a specific manufacturer
- X.25 packet switch / legacy WAN router
Monitoring Examples
An administrator would poll the PLE table to compare configured channel assignments and administrative parameters against the values actually in use, and check packet-layer statistics counters for errors or resets on a given virtual circuit. A mismatch between the administrator-set values and the in-use values would indicate a configuration that failed to apply or a fallback to defaults, useful for diagnosing why an X.25 link is not passing traffic as expected.
What Can Be Monitored
- PLE administrative vs. operational configuration
- virtual circuit/channel assignments
- packet-layer error statistics
- packet-layer traffic counters
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString |
From RS232-MIB
| rs232PortIndex | OBJECT-TYPE |
From SNMPv2-TC
| RowStatus |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| ngcan | 1.3.6.1.4.1.1978 | |||
| tiger | 1.3.6.1.4.1.1978.2 | |||
| x25MIB | 1.3.6.1.4.1.1978.2.14 | |||
| x25L3 | 1.3.6.1.4.1.1978.2.14.1 | |||
| x25AdmnTable | 1.3.6.1.4.1.1978.2.14.1.1 | not-accessible | This table contains configuration, channel assignments and statistics for an X.25 Packet Level Entity (PLE). The values are as last set by the administrator and/or the values actually in use by the PLE. | |
| x25AdmnEntry | 1.3.6.1.4.1.1978.2.14.1.1.1 | not-accessible | Entries of x25AdmnTable. | |
| NUM x25AdmnIndex | 1.3.6.1.4.1.1978.2.14.1.1.1.1 | InterfaceIndex | read-write | The ifIndex value for the X.25 Interface. |
| INT x25AdmnInterfaceMode | 1.3.6.1.4.1.1978.2.14.1.1.1.2 | INTEGER | read-write | Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation. |
| INT x25AdmnPacketSequencing | 1.3.6.1.4.1.1978.2.14.1.1.1.3 | INTEGER | read-write | The modulus of the packet sequence number space. |
| INT x25AdmnRestartTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.4 | INTEGER | read-write | The T20 restart timer in milliseconds. UNITS: milliseconds |
| INT x25AdmnCallTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.5 | INTEGER | read-write | The T21 Call timer in milliseconds. UNITS: milliseconds |
| INT x25AdmnResetTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.6 | INTEGER | read-write | The T22 Reset timer in milliseconds. UNITS: milliseconds |
| INT x25AdmnClearTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.7 | INTEGER | read-write | The T23 Clear timer in milliseconds. UNITS: milliseconds |
| INT x25AdmnWindowTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.8 | INTEGER | read-write | The T24 window status transmission timer in milliseconds. A value of 0 indicates no window timer in use. UNITS: milliseconds |
| INT x25AdmnDataRxmtTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.9 | INTEGER | read-write | The T25 data retransmission timer in milliseconds. A value of 0 indicates no data retransmission timer in use. UNITS: milliseconds |
| INT x25AdmnInterruptTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.10 | INTEGER | read-write | The T26 interrupt timer in milliseconds. A value of 0 indicates no interrupt timer in use. UNITS: milliseconds |
| INT x25AdmnRejectTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.11 | INTEGER | read-write | The T27 Reject retransmission timer in milliseconds. A value of 0 indicates no reject timer in use. UNITS: milliseconds |
| INT x25AdmnRegistrationRequestTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.12 | INTEGER | read-write | The T28 registration timer in milliseconds. A value of 0 indicates no registration timer in use. UNITS: milliseconds |
| INT x25AdmnRestartCount | 1.3.6.1.4.1.1978.2.14.1.1.1.13 | INTEGER | read-write | The R20 restart retransmission count. |
| INT x25AdmnResetCount | 1.3.6.1.4.1.1978.2.14.1.1.1.14 | INTEGER | read-write | The r22 Reset retransmission count. |
| INT x25AdmnClearCount | 1.3.6.1.4.1.1978.2.14.1.1.1.15 | INTEGER | read-write | The r23 Clear retransmission count. |
| INT x25AdmnDataRxmtCount | 1.3.6.1.4.1.1978.2.14.1.1.1.16 | INTEGER | read-write | The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use. |
| INT x25AdmnRejectCount | 1.3.6.1.4.1.1978.2.14.1.1.1.17 | INTEGER | read-write | The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use. |
| INT x25AdmnRegistrationRequestCount | 1.3.6.1.4.1.1978.2.14.1.1.1.18 | INTEGER | read-write | The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use. |
| INT x25AdmnNumberPVCs | 1.3.6.1.4.1.1978.2.14.1.1.1.19 | INTEGER | read-write | The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number. Set to 0 for no PVCs. |
| X25 x25AdmnDefCallParamId | 1.3.6.1.4.1.1978.2.14.1.1.1.20 | X25CallParamIndex | read-write | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE. |
| INT x25AdmnProtocolVersionSupported | 1.3.6.1.4.1.1978.2.14.1.1.1.21 | INTEGER | read-write | Identifies the version of the X.25 protocol this interface should support. |
| INT x25AdmnRegistrationMode | 1.3.6.1.4.1.1978.2.14.1.1.1.22 | INTEGER | read-write | Defines how registration exchanges are handled. A value of auto indicates that the DTE always sends empty request at connection time and that a DCE automatically answers incoming requests. A value of user indicates that registration packets are handled at the user level and the packet level still updates its internal configuration according to the the confirmation content. |
| INT x25AdmnDiagnosticMode | 1.3.6.1.4.1.1978.2.14.1.1.1.23 | INTEGER | read-write | Controls the generation of diagnostic packets. A value of standard means send diagnostics if configured as a DCE only, as per CCITT specification. A value of on always sends diagnostic packets, and a value of off will never send diagnostic packets. |
| INT x25AdmnInterruptSize | 1.3.6.1.4.1.1978.2.14.1.1.1.24 | INTEGER | read-write | Defines the maximum user data size in interrupt packets. Use 1 for networks compliant with 1980 CCITT recommendation and before, use 32 for 1984 and later compliant networks, any other value is used only when dealing with non CCITT compliant implementations. |
| INT x25AdmnMaxTxWindow | 1.3.6.1.4.1.1978.2.14.1.1.1.25 | INTEGER | read-write | Specifies the maximum transmit window size that can be negotiated. 1 through 7 for modulo 8. 1 through 128 for modulo 128. |
| INT x25AdmnMaxRxWindow | 1.3.6.1.4.1.1978.2.14.1.1.1.26 | INTEGER | read-write | Specifies the maximum receive window size that can be negotiated. 1 through 7 for modulo 8. 1 through 128 for modulo 128. |
| INT x25AdmnFacilityLength | 1.3.6.1.4.1.1978.2.14.1.1.1.27 | INTEGER | read-write | Defines the maximum length of the Facility field. Use 63 for 1980 or earlier complience. Use 109 for 1984 and later compliant networks. Other value are used only when dealing with non CCITT compliant implementations. |
| INT x25AdmnCallDataSize | 1.3.6.1.4.1.1978.2.14.1.1.1.28 | INTEGER | read-write | Defines the maximum length of the user data in call request/indication packets when fast select not used. Use 16 for CCITT complience. Other value are used only when dealing with non CCITT compliant implementations. |
| INT x25AdmnFastSelectCallDataSize | 1.3.6.1.4.1.1978.2.14.1.1.1.29 | INTEGER | read-write | Defines the maximum length of the user data in call request/indication packets when fast select is used. Use 128 for CCITT complience. Other value are used only when dealing with non CCITT compliant implementations. |
| INT x25AdmnExtendedClear | 1.3.6.1.4.1.1978.2.14.1.1.1.30 | INTEGER | read-write | Controls support for extended clear format (allow addresses and facilities in clear/clear cf packets). A value of on means that the extended clear format is supported. A value of off means that the extended clear is not supported, receipt from the user is an error. A value of convert means accept extended clears from the user but convert them to short format before transmission to the network, accept whatever the network sends us. Note: The extended format is used in a clear if fast select is present in the facility field, no matter what the setting of this parameter is. |
| INT x25AdmnCause | 1.3.6.1.4.1.1978.2.14.1.1.1.31 | INTEGER | read-write | Controls how a cause field from the user is converted. A value of asis means send the user cause as is. A value of ccitt-80 means convert to 1980 format (clear if DTE, cause & 0x07F if DCE). A value of ccitt-84 means use 1984 format (0 or cause | 0x80 if DTE, cause & 0x07F if DCE). A value of clear means always clear the cause fields from the user. |
| INT x25AdmnABit | 1.3.6.1.4.1.1978.2.14.1.1.1.32 | INTEGER | read-write | x25AdmnABit defines how long addresses, (up to 17 digits,) are handled. A value of on, means always use the long address format. A value of off, means always use the short address format. A value of ok, means use the long format, but accept short addresses from the network. |
| INT x25AdmnRRTrigger | 1.3.6.1.4.1.1978.2.14.1.1.1.33 | INTEGER | read-write | This defines when the frame level sends RR. 0: Only send RR when the window is full. Very inefficient as it always causes the remote to enter flow control situations. Not recommended. 1: Send RR when receiving one mode data packet would make the window full. Suggested value on modulo 7 point-to- point links with small transit delays. >=k: If the value of the parameter is greater than the window size, this causes RR packets to always be transmitted immediately as soon as a data packet is received. To obtain this mode of operation whatever the negitiated window size may be, it is suggested to set the value of this parameter to 128. =k) |
| INT x25AdmnRRTimer | 1.3.6.1.4.1.1978.2.14.1.1.1.34 | INTEGER | read-write | This x25AdmnRRTimer only causes the transmission of an RR Packet when there are outstanding packets to acknowledge to the remote. When the transmission of RR packets to the remote is delayed because the x25AdmnRRTrigger value is set to a value within the receive window, this timer is used to force the transmission of RR packets after some time. Without this timer, delaying RR Packets would cause the last packets of a transaction never to be acknowledged. Please note that this timer is not similar to the T24 timer. The T24 timer causes an RR packet to be sent whenever no packet carrying an ack has been sent for a while. In addition, the duration of T24 is typically fairly large (60 seconds recommended), while this RR timer should be much smaller to ensure that packets are always acknowledged in a reasonable amount of time. Note: The time is in milliseconds. Note: Setting x25AdmnRRTrigger to a value outside of the receive window or setting this timer value to 0 force RR packets to always be transmitted as soon as a data packet is received from the remote without any delay. UNITS: milliseconds |
| INT x25AdmnRRPiggy | 1.3.6.1.4.1.1978.2.14.1.1.1.35 | INTEGER | read-write | This specifies whether the frame level can 'piggyback' acknowledgements in I frames. |
| INT x25AdmnTxRejectMode | 1.3.6.1.4.1.1978.2.14.1.1.1.36 | INTEGER | read-write | Defines how packet level handles the reception of out of sequence data packets. A value of reset will reset the virtual circuit. A value of rejectReset will send reject packet if configured as a DTE. otherwise it will reset the virtual circuit. A value of sendAlways will cause a reject packet to always be sent, even when configured as a DCE. Note: CCITT compliance requires the selection of either reset or rejectReset. The CCITT does not allow a DCE to send a reject. |
| INT x25AdmnRxRejectMode | 1.3.6.1.4.1.1978.2.14.1.1.1.37 | INTEGER | read-write | Defines how packet level handles the reception of reject packets. A value of reset will reset the virtual circuit. A value of retxReset will retransmit packets if configured as a DCE. otherwise it will reset the virtual circuit. A value of retxAlways will cause retransmition of data packets even when configured as a DTE. Note: CCITT compliance requires the selection of either reset or retxReset. The CCITT does not allow a DTE to retransmit. |
| INT x25AdmnDBit | 1.3.6.1.4.1.1978.2.14.1.1.1.38 | INTEGER | read-write | Defines how packet level handles the D bit. A value of no indicates that the use of the D bit not allowed. A value of ok indicates that the use of the D bit is allowed. A value of bill indicates that the use of the D bit is allowed only if we are not billed for the call. |
| INT x25AdmnR28Action | 1.3.6.1.4.1.1978.2.14.1.1.1.39 | INTEGER | read-write | Selects the packet level action after R28 expirations of the registration timer T28. A value of fail means the link is considered as non operational and is disconnected. The x25AdmnRegistrationMode parameter determine if the complete reconnection procedure is tried again. A value of ignore means: Go to the ready state using the default link configuration, as if the registration never occurred. |
| INT x25ChannelLIC | 1.3.6.1.4.1.1978.2.14.1.1.1.40 | INTEGER | read-write | Lowest Incoming channel. A value of 0 indicates that no LCN is available. |
| INT x25ChannelHIC | 1.3.6.1.4.1.1978.2.14.1.1.1.41 | INTEGER | read-write | Highest Incoming channel. A value of 4095 indicates that no LCN is available. |
| INT x25ChannelLTC | 1.3.6.1.4.1.1978.2.14.1.1.1.42 | INTEGER | read-write | Lowest Two-way channel. A value of 0 indicates that no LCN is available. |
| INT x25ChannelHTC | 1.3.6.1.4.1.1978.2.14.1.1.1.43 | INTEGER | read-write | Highest Two-way channel. A value of 0 indicates that no LCN is available. |
| INT x25ChannelLOC | 1.3.6.1.4.1.1978.2.14.1.1.1.44 | INTEGER | read-write | Lowest outgoing channel. A value of 0 indicates that no LCN is available. |
| INT x25ChannelHOC | 1.3.6.1.4.1.1978.2.14.1.1.1.45 | INTEGER | read-write | Highest outgoing channel. A value of 0 indicates that no LCN is available. |
| CTR x25StatInCalls | 1.3.6.1.4.1.1978.2.14.1.1.1.46 | Counter | read-only | The number of Call Request/Indication packets received. |
| CTR x25StatInCallRefusals | 1.3.6.1.4.1.1978.2.14.1.1.1.47 | Counter | read-only | The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast select. |
| CTR x25StatInProviderInitiatedClears | 1.3.6.1.4.1.1978.2.14.1.1.1.48 | Counter | read-only | The number of Clear Request/Indication packets sent. |
| CTR x25StatInRemotelyInitiatedResets | 1.3.6.1.4.1.1978.2.14.1.1.1.49 | Counter | read-only | The number of Reset Request/Indication packets received. |
| CTR x25StatInProviderInitiatedResets | 1.3.6.1.4.1.1978.2.14.1.1.1.50 | Counter | read-only | The number of Reset Request/Indication packets sent. |
| CTR x25StatInRestarts | 1.3.6.1.4.1.1978.2.14.1.1.1.51 | Counter | read-only | The number of Restart Request/Indication packets received. |
| CTR x25StatInDataPackets | 1.3.6.1.4.1.1978.2.14.1.1.1.52 | Counter | read-only | The number of data packets received. |
| CTR x25StatInAccusedOfProtocolErrors | 1.3.6.1.4.1.1978.2.14.1.1.1.53 | Counter | read-only | The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets. |
| CTR x25StatInInterrupts | 1.3.6.1.4.1.1978.2.14.1.1.1.54 | Counter | read-only | The number of interrupt packets received by the PLE or over the PVC/VC. |
| CTR x25StatOutCallAttempts | 1.3.6.1.4.1.1978.2.14.1.1.1.55 | Counter | read-only | The number of calls attempted. |
| CTR x25StatOutCallFailures | 1.3.6.1.4.1.1978.2.14.1.1.1.56 | Counter | read-only | The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select. |
| CTR x25StatOutInterrupts | 1.3.6.1.4.1.1978.2.14.1.1.1.57 | Counter | read-only | The number of interrupt packets send by the PLE or over the PVC/VC. |
| CTR x25StatOutDataPackets | 1.3.6.1.4.1.1978.2.14.1.1.1.58 | Counter | read-only | The number of data packets sent by this PLE. |
| CTR x25StatPVCCircuits | 1.3.6.1.4.1.1978.2.14.1.1.1.59 | Counter | read-only | The number of active PVC circuits. |
| CTR x25StatSVCCircuits | 1.3.6.1.4.1.1978.2.14.1.1.1.60 | Counter | read-only | The number of active SVC Circuits. This includes call indications received but not yet acknowledged. |
| CTR x25StatRestartTimeouts | 1.3.6.1.4.1.1978.2.14.1.1.1.61 | Counter | read-only | The number of times the T20 restart timer expired. |
| CTR x25StatCallTimeouts | 1.3.6.1.4.1.1978.2.14.1.1.1.62 | Counter | read-only | The number of times the T21 call timer expired. |
| CTR x25StatResetTimeouts | 1.3.6.1.4.1.1978.2.14.1.1.1.63 | Counter | read-only | The number of times the T22 reset timer expired. |
| CTR x25StatClearTimeouts | 1.3.6.1.4.1.1978.2.14.1.1.1.64 | Counter | read-only | The number of times the T23 clear timer expired. |
| CTR x25StatDataRxmtTimeouts | 1.3.6.1.4.1.1978.2.14.1.1.1.65 | Counter | read-only | The number of times the T25 data timer expired. |
| CTR x25StatInterruptTimeouts | 1.3.6.1.4.1.1978.2.14.1.1.1.66 | Counter | read-only | The number of times the T26 interrupt timer expired. |
| CTR x25StatRetryCountExceededs | 1.3.6.1.4.1.1978.2.14.1.1.1.67 | Counter | read-only | The number of times a retry counter was exhausted. |
| CTR x25StatClearCountExceededs | 1.3.6.1.4.1.1978.2.14.1.1.1.68 | Counter | read-only | The number of times the R23 clear count was exceeded. |
| INT x25AdminTrapControl | 1.3.6.1.4.1.1978.2.14.1.1.1.69 | INTEGER | read-write | If enabled, it allows the system to generate x25Restart and x25VC traps |
| x25CircuitTable | 1.3.6.1.4.1.1978.2.14.1.2 | not-accessible | These objects contain general information about a specific circuit of an X.25 PLE. | |
| x25CircuitEntry | 1.3.6.1.4.1.1978.2.14.1.2.1 | not-accessible | Entries of x25CircuitTable. | |
| NUM x25CircuitIndex | 1.3.6.1.4.1.1978.2.14.1.2.1.1 | InterfaceIndex | read-only | The ifIndex value for the X.25 Interface. |
| INT x25CircuitChannel | 1.3.6.1.4.1.1978.2.14.1.2.1.2 | INTEGER | read-only | The channel number for this circuit. |
| INT x25CircuitStatus | 1.3.6.1.4.1.1978.2.14.1.2.1.3 | INTEGER | read-only | This object reports the current status of the circuit. 'Network' refers to the X.25 network below this module. 'User Application' refers to the software module above this module. - The software driving X.25 Level 3. - This module. - LAPB --> X.25 Link. The state descriptions are as follows: inactive - VC is not active. wait-for-setup - VC is not active but ready for Call Setup. received-call - Received Call Request/Indication from the Network, awaiting User Application response. sent-call - Sent the network a Call Request/Indication, awaiting Network response. data-unused - Data Transfer (unused) call-collision - Call Collision - Sent the network a Call Request/Indication, received Call Request/Indication from the Network. sent-user-clear - Sent User Application a Clear request, awaiting a Clear confirm from the User Application. sent-net-clear - Sent the network a Clear Request/Indication, awaiting a Clear Confirm/Response from the Network. data - Data Transfer state. sent-user-reset - Sent the User Application a Reset request, awaiting a response from the User Application. sent-net-reset - Sent the Network a Reset Request/Indication, awaiting a response from the Network. |
| TIK x25CircuitEstablishTime | 1.3.6.1.4.1.1978.2.14.1.2.1.4 | TimeTicks | read-only | The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was able to pass data to a higher layer entity without loss of data. |
| INT x25CircuitDirection | 1.3.6.1.4.1.1978.2.14.1.2.1.5 | INTEGER | read-only | The direction of the call that established this circuit. |
| CTR x25CircuitInOctets | 1.3.6.1.4.1.1978.2.14.1.2.1.6 | Counter | read-only | The number of octets of user data delivered to upper layer. |
| CTR x25CircuitInPdus | 1.3.6.1.4.1.1978.2.14.1.2.1.7 | Counter | read-only | The number of PDUs received for this circuit. |
| CTR x25CircuitInRemotelyInitiatedResets | 1.3.6.1.4.1.1978.2.14.1.2.1.8 | Counter | read-only | The number of Resets received for this circuit with cause code of DTE initiated. |
| CTR x25CircuitInProviderInitiatedResets | 1.3.6.1.4.1.1978.2.14.1.2.1.9 | Counter | read-only | The number of Resets received for this circuit with cause code other than DTE initiated. |
| CTR x25CircuitInInterrupts | 1.3.6.1.4.1.1978.2.14.1.2.1.10 | Counter | read-only | The number of interrupt packets received for this circuit. |
| CTR x25CircuitOutOctets | 1.3.6.1.4.1.1978.2.14.1.2.1.11 | Counter | read-only | The number of octets of user data sent for this circuit. |
| CTR x25CircuitOutPdus | 1.3.6.1.4.1.1978.2.14.1.2.1.12 | Counter | read-only | The number of PDUs sent for this circuit. |
| CTR x25CircuitOutInterrupts | 1.3.6.1.4.1.1978.2.14.1.2.1.13 | Counter | read-only | The number of interrupt packets sent on this circuit. |
| CTR x25CircuitDataRetransmissionTimeouts | 1.3.6.1.4.1.1978.2.14.1.2.1.14 | Counter | read-only | The number of times the T25 data retransmission timer expired for this circuit. |
| CTR x25CircuitResetTimeouts | 1.3.6.1.4.1.1978.2.14.1.2.1.15 | Counter | read-only | The number of times the T22 reset timer expired for this circuit. |
| CTR x25CircuitInterruptTimeouts | 1.3.6.1.4.1.1978.2.14.1.2.1.16 | Counter | read-only | The number of times the T26 Interrupt timer expired for this circuit. |
| INT x25CircuitCallParamId | 1.3.6.1.4.1.1978.2.14.1.2.1.17 | INTEGER | read-only | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than proposed values. A value of NULL indicates the circuit is a PVC or is using all the default parameters. |
| ADR x25CircuitCalledAddress | 1.3.6.1.4.1.1978.2.14.1.2.1.18 | X121Address | read-only | The Called X.121 Address in the Incoming or Outgoing Call packets. |
| ADR x25CircuitCallingAddress | 1.3.6.1.4.1.1978.2.14.1.2.1.19 | X121Address | read-only | The Calling X.121 Address in the Incoming or Outgoing Call packets. |
| ADR x25CircuitOriginallyCalledAddress | 1.3.6.1.4.1.1978.2.14.1.2.1.20 | X121Address | read-only | For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it will be called address from the call indication packet. For outgoing calls, this is the address from the call request packet. This will be zero length for PVCs. |
| STR x25CircuitDescr | 1.3.6.1.4.1.1978.2.14.1.2.1.21 | DisplayString | read-write | A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of the circuit. The agent may return the process identifier and user name for the process using the circuit. Alternative the agent may return the name of the configuration entry that caused a bridge to establish the circuit. A zero length value indicates the agent doesn't have any additional information. |
| INT x25CircuitRNRReceive | 1.3.6.1.4.1.1978.2.14.1.2.1.22 | INTEGER | read-only | This element shows whether a receive RNR (from the network) condition exits. |
| INT x25CircuitRNRSent | 1.3.6.1.4.1.1978.2.14.1.2.1.23 | INTEGER | read-only | This element shows whether a sent RNR (to the network) condition exits. |
| INT x25CircuitTrapType | 1.3.6.1.4.1.1978.2.14.1.2.1.24 | INTEGER | read-only | The type of event that caused the trap to occur. reset - generated whenever that packet type is sent or received. clear - generated whenever that packet type is sent or received. sent-rr2rnr - generated whenever an RNR packet is transmitted, causing a flow control condition. sent-rnr2rr - generated whenever an RR packet is transmitted ending a flow control condition. recv-rr2rnr - generated whenever an RNR packet is received, causing a flow control condition. recv-rnr2rr - generated whenever an RR packet is received ending a flow control condition. |
| INT x25CircuitTrapCause | 1.3.6.1.4.1.1978.2.14.1.2.1.25 | INTEGER | read-only | The cause field of the message that caused the trap to occur. |
| INT x25CircuitTrapDiagnostic | 1.3.6.1.4.1.1978.2.14.1.2.1.26 | INTEGER | read-only | The diagnostic field of the message that caused the trap to occur. |
| x25CallParmTable | 1.3.6.1.4.1.1978.2.14.1.3 | not-accessible | These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of these tables for the entire system. The indexes for the entries are independent of any PLE or any circuit. Other tables reference entries in this table. Entries in this table can be used for default PLE parameters, for parameters to use to place/answer a call, for the parameters currently in use for a circuit, or parameters that were used by a circuit. The number of references to a given set of parameters can be found in the x25CallParmRefCount object sharing the same instance identifier with the parameters. The value of this reference count also affects the access of the objects in this table. An object in this table with the same instance identifier as the instance identifier of an x25CallParmRefCount must be consider associated with that reference count. An object with an associated reference count of zero can be written (if its MAX-ACCESS clause allows it). An object with an associated reference count greater than zero can not be written (regardless of the MAX-ACCESS clause). This ensures that a set of call parameters being referenced from another table can not be modified or changed in a ways inappropriate for continued use by that table. | |
| x25CallParmEntry | 1.3.6.1.4.1.1978.2.14.1.3.1 | not-accessible | Entries of x25CallParmTable. | |
| INT x25CallParmIndex | 1.3.6.1.4.1.1978.2.14.1.3.1.1 | INTEGER | read-write | A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossible to know which other objects in the MIB reference entries in the table by looking at this table. Because of this, changes to parameters must be accomplished by creating a new entry in this table and then changing the referencing table to identify the new entry. Note that an agent will only use the values in this table when another table is changed to reference those values. The number of other tables that reference an index object in this table can be found in x25CallParmRefCount. The value of the reference count will affect the writability of the objects as explained above. Entries in this table which have a reference count of zero maybe deleted at the convence of the agent. Care should be taken by the agent to give the NMS sufficient time to create a reference to newly created entries. Should a Management Station not find a free index with which to create a new entry, it may feel free to delete entries with a reference count of zero. However in doing so the Management Station much realize it may impact other Management Stations. |
| ROW x25CallParmStatus | 1.3.6.1.4.1.1978.2.14.1.3.1.2 | RowStatus | read-write | The status of this call parameter entry. See RFC 1271 for details of usage. |
| INT x25CallParmRefCount | 1.3.6.1.4.1.1978.2.14.1.3.1.3 | INTEGER | read-write | The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value of, and will return a value of, the index for this set of call parameters. Examples of such objects is the x25AdmnDefCallParamId object defined above. |
| INT x25CallParmInPacketSize | 1.3.6.1.4.1.1978.2.14.1.3.1.4 | INTEGER | read-write | The default receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128. |
| INT x25CallParmOutPacketSize | 1.3.6.1.4.1.1978.2.14.1.3.1.5 | INTEGER | read-write | The default transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128. |
| INT x25CallParmInWindowSize | 1.3.6.1.4.1.1978.2.14.1.3.1.6 | INTEGER | read-write | The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| INT x25CallParmOutWindowSize | 1.3.6.1.4.1.1978.2.14.1.3.1.7 | INTEGER | read-write | The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| INT x25CallParmAcceptReverseCharging | 1.3.6.1.4.1.1978.2.14.1.3.1.8 | INTEGER | read-write | An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of alwaysRefuse is only used for the PLE default and indicates the PLE will never accept reverse charging. A value of default for a PLE default means refuse. |
| INT x25CallParmProposeReverseCharging | 1.3.6.1.4.1.1978.2.14.1.3.1.9 | INTEGER | read-write | An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default for the PLE default means use local. |
| INT x25CallParmFastSelect | 1.3.6.1.4.1.1978.2.14.1.3.1.10 | INTEGER | read-write | Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means alwaysReject. A value of alwaysReject indicates a circuit may not use fast select. |
| INT x25CallParmInThruPutClasSize | 1.3.6.1.4.1.1978.2.14.1.3.1.11 | INTEGER | read-write | The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone. A value of tcNone means do not negotiate throughtput class. |
| INT x25CallParmOutThruPutClasSize | 1.3.6.1.4.1.1978.2.14.1.3.1.12 | INTEGER | read-write | The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tcNone. A value of tcNone means do not negotiate throughtput class. |
| STR x25CallParmCug | 1.3.6.1.4.1.1978.2.14.1.3.1.13 | DisplayString | read-write | The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility requested. A string length of three containing the characters DEF for a circuit means use the PLE default, (the PLE default parameter may not reference an entry of DEF.) |
| STR x25CallParmCugoa | 1.3.6.1.4.1.1978.2.14.1.3.1.14 | DisplayString | read-write | The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameters may not reference an entry of DEF). A zero length string indicates no facility requested. |
| STR x25CallParmBcug | 1.3.6.1.4.1.1978.2.14.1.3.1.15 | DisplayString | read-write | The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameter may not reference an entry of DEF). A zero length string indicates no facility requested. |
| OCT x25CallParmNui | 1.3.6.1.4.1.1978.2.14.1.3.1.16 | OCTET STRING | read-write | The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero length string indicates no facility requested. This value is ignored for the PLE default parameters entry. |
| INT x25CallParmChargingInfo | 1.3.6.1.4.1.1978.2.14.1.3.1.17 | INTEGER | read-write | The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use noFacility. The value of noFacility means do not include a facility. |
| STR x25CallParmRpoa | 1.3.6.1.4.1.1978.2.14.1.3.1.18 | DisplayString | read-write | The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 characters DEF for a circuit specifies use of the PLE default (the entry for the PLE default may not contain DEF). A zero length string indicates no facility requested. |
| INT x25CallParmTrnstDly | 1.3.6.1.4.1.1978.2.14.1.3.1.19 | INTEGER | read-write | The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (the PLE default parameters entry may not use the value 65537). The value 65535 may only be used to indicate the value in use by a circuit. |
| STR x25CallParmCallingExt | 1.3.6.1.4.1.1978.2.14.1.3.1.20 | DisplayString | read-write | The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested. |
| STR x25CallParmCalledExt | 1.3.6.1.4.1.1978.2.14.1.3.1.21 | DisplayString | read-write | The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested. |
| INT x25CallParmInMinThuPutCls | 1.3.6.1.4.1.1978.2.14.1.3.1.22 | INTEGER | read-write | The minimum input throughput Class. A value of 17 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 16 indicates no facility requested. |
| INT x25CallParmOutMinThuPutCls | 1.3.6.1.4.1.1978.2.14.1.3.1.23 | INTEGER | read-write | The minimum output throughput Class. A value of 17 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 16 indicates no facility requested. |
| OCT x25CallParmEndTrnsDly | 1.3.6.1.4.1.1978.2.14.1.3.1.24 | OCTET STRING | read-write | The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE default (the entry for the PLE default can not contain the characters DEF). A zero length string indicates no facility requested. |
| OCT x25CallParmPriority | 1.3.6.1.4.1.1978.2.14.1.3.1.25 | OCTET STRING | read-write | The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requested. The entry for the PLE default parameters must be zero length. |
| STR x25CallParmProtection | 1.3.6.1.4.1.1978.2.14.1.3.1.26 | DisplayString | read-write | A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the packet by the agent. The agent will supply the length field and the length octet is not contained in this string. An string containing the 3 characters DEF for a circuit means use the PLE default (the entry for the PLE default parameters may not use the value DEF). A zero length string mean no facility requested. |
| INT x25CallParmExptData | 1.3.6.1.4.1.1978.2.14.1.3.1.27 | INTEGER | read-write | The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not have the value default. |
| OCT x25CallParmUserData | 1.3.6.1.4.1.1978.2.14.1.3.1.28 | OCTET STRING | read-write | The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE has data defined, the PLE entry will be used. If neither the circuit call parameters or the PLE default entry has a value, no call user data will be sent. |
| OCT x25CallParmCallingNetworkFacilities | 1.3.6.1.4.1.1978.2.14.1.3.1.29 | OCTET STRING | read-write | The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities. |
| OCT x25CallParmCalledNetworkFacilities | 1.3.6.1.4.1.1978.2.14.1.3.1.30 | OCTET STRING | read-write | The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities. |
| INT x25CallParmInMaxPktSize | 1.3.6.1.4.1.1978.2.14.1.3.1.31 | INTEGER | read-write | The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128. |
| INT x25CallParmOutMaxPktSize | 1.3.6.1.4.1.1978.2.14.1.3.1.32 | INTEGER | read-write | The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128. |
| x25Traps | 1.3.6.1.4.1.1978.2.14.2 | |||
| x25L3Traps | 1.3.6.1.4.1.1978.2.14.2.1 | |||
| NTF x25Restart | 1.3.6.1.4.1.1978.2.14.2.1.0.1 | This trap means the X.25 PLE completed a link restart packet has been sent and: a) a restart packet was received (Restart Collision) b) a restart confirm packet was received. c) the Restart retransmission counter (R20) expires. The packet module now considers the link to be established and ready for Virtual Circuit establishment. | ||
| NTF x25VC | 1.3.6.1.4.1.1978.2.14.2.1.0.2 | Sent if a virtual circuit needs to send a trap for one of its reasons listed in x25CircuitTrapType. |
RFC description
Manages X.25 packet layer protocol configuration, channels, and statistics on network access devices.
Start monitoring vendor-neutral, standards-based MIB, X.25 packet switch / legacy WAN router (PLE channel-assignment/packet-layer statistics status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.