x25AdmnRRTrigger

Module: X25-MIB

OID (symbolic): X25-MIB::x25AdmnRRTrigger

OID (numeric): 1.3.6.1.4.1.1978.2.14.1.1.1.33

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This defines when the frame level sends RR.

0: Only send RR when the window is full. Very inefficient as it always causes the remote to enter flow control situations. Not recommended.

1: Send RR when receiving one mode data packet would make the window full. Suggested value on modulo 7 point-to- point links with small transit delays.

>=k: If the value of the parameter is greater than the window size, this causes RR packets to always be transmitted immediately as soon as a data packet is received. To obtain this mode of operation whatever the negitiated window size may be, it is suggested to set the value of this parameter to 128.

< k: Use the specified value,

256: This special value causes RR packets transmission to occur whenever the receive window is half full.

Where k is the value of lapbAdmnKWindowSize. (default = >=k)

What is x25AdmnRRTrigger?

Read-write threshold controlling when the packet level sends a Receiver Ready (RR) acknowledgment; the special value 256 sends RR whenever the receive window is half full, while a value at or above the window size forces an RR after every data packet.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1978.2.14.1.1.1.33
snmpwalk -v2c -c public <target> X25-MIB::x25AdmnRRTrigger

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1978.2.14.1.1.1.33.1
snmpget -v2c -c public <target> X25-MIB::x25AdmnRRTrigger.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1978.2.14.1.1.1.33.1 i <value>

Start monitoring vendor-neutral, standards-based MIB, X.25 packet switch / legacy WAN router (PLE channel-assignment/packet-layer statistics status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the X25-MIB::x25AdmnRRTrigger OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, X.25 packet switch / legacy WAN router (PLE channel-assignment/packet-layer statistics status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1978ngcanALC-MIB
1.3.6.1.4.1.1978.2tigerALC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1978.2.14x25MIBX25-MIB
1.3.6.1.4.1.1978.2.14.1x25L3X25-MIB
1.3.6.1.4.1.1978.2.14.1.1x25AdmnTableX25-MIB
1.3.6.1.4.1.1978.2.14.1.1.1x25AdmnEntryX25-MIB
1.3.6.1.4.1.1978.2.14.1.1.1.33x25AdmnRRTriggerX25-MIB