WS-TRAP-MIB :: wsTrapEnableDiagTempTooHighRecover

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WS-TRAP-MIB › wsTrapEnableDiagTempTooHighRecover

wsTrapEnableDiagTempTooHighRecover

Module: WS-TRAP-MIB

OID (symbolic): WS-TRAP-MIB::wsTrapEnableDiagTempTooHighRecover

OID (numeric): 1.3.6.1.4.1.388.14.5.1.4.44

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Enable temperature recovered from exceeding high limit trap.

What is wsTrapEnableDiagTempTooHighRecover?

Enables or disables the recovery trap fired when device temperature drops back below the high limit after having exceeded it, signaling the over-temperature condition has cleared.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.388.14.5.1.4.44
snmpwalk -v2c -c public <target> WS-TRAP-MIB::wsTrapEnableDiagTempTooHighRecover

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.388.14.5.1.4.44.1
snmpget -v2c -c public <target> WS-TRAP-MIB::wsTrapEnableDiagTempTooHighRecover.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.388.14.5.1.4.44.1 s <value>

Start monitoring Symbol Technologies wireless switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WS-TRAP-MIB::wsTrapEnableDiagTempTooHighRecover OID value, configure state conditions and alerts, and monitor any Symbol Technologies wireless switches from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.388symbolSYMBOL-DSSS-ENTERPRISE-PRIVATE-MIB
1.3.6.1.4.1.388.14wsWS-SMI
1.3.6.1.4.1.388.14.5wsTrapWS-SMI
Numeric OIDNameModule
1.3.6.1.4.1.388.14.5.1wsTrapMIBWS-TRAP-MIB
1.3.6.1.4.1.388.14.5.1.4wsTrapDiagWS-TRAP-MIB
1.3.6.1.4.1.388.14.5.1.4.44wsTrapEnableDiagTempTooHighRecoverWS-TRAP-MIB