| OID symbolic | OID numeric | Type | Access | Description |
| tnSyncEMibModule | 1.3.6.1.4.1.7483.1.1.2.2.4.6 | | | Synchronous Ethernet MIB attributes. |
| tnSyncEConf | 1.3.6.1.4.1.7483.2.2.4.8.1 | | | |
| tnSyncEGroups | 1.3.6.1.4.1.7483.2.2.4.8.1.1 | | | |
| tnSyncEGroup | 1.3.6.1.4.1.7483.2.2.4.8.1.1.1 | | | |
| tnSyncELineRefGroup | 1.3.6.1.4.1.7483.2.2.4.8.1.1.2 | | | |
| tnSyncEControlGroup | 1.3.6.1.4.1.7483.2.2.4.8.1.1.3 | | | |
| tnSyncEPortGroup | 1.3.6.1.4.1.7483.2.2.4.8.1.1.4 | | | |
| tnSyncEStationClockGroup | 1.3.6.1.4.1.7483.2.2.4.8.1.1.5 | | | |
| tnSyncEBITSPortGroup | 1.3.6.1.4.1.7483.2.2.4.8.1.1.6 | | | |
| tnSyncECompliances | 1.3.6.1.4.1.7483.2.2.4.8.1.2 | | | |
| tnSyncECompliance | 1.3.6.1.4.1.7483.2.2.4.8.1.2.1 | | | |
| tnSyncEObjs | 1.3.6.1.4.1.7483.2.2.4.8.2 | | | |
| tnSyncEBasics | 1.3.6.1.4.1.7483.2.2.4.8.2.1 | | | |
| tnSyncETable | 1.3.6.1.4.1.7483.2.2.4.8.2.1.1 | | not-accessible | Table of Sync-E attributes. |
| tnSyncEEntry | 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1 | | not-accessible | |
| T/F tnSyncESyncMsg | 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.1 | TruthValue | read-create | Determines if the timing reference selection for
system timing uses sync status messaging (SSM
Qualities). |
| INT tnSyncEActiveRef | 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.2 | INTEGER | read-only | The ID of the association line reference. |
| U32 tnSyncEWTR | 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.3 | Unsigned32 | read-create | The system timing WTR.
Current configurable range: 0 to 12, and 999999. |
| U32 tnSyncESwCmdLineRef | 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.4 | Unsigned32 | read-create | The third byte represents the switch command:
1 - nocmd
2 - clear
3 - lockout
4 - forceswitch
5 - mannual
6 - auto
7 - clearlockout.
The last byte represents the line reference switch to:
0 - internal
1 - lineref0
2 - lineref1
3 - lineref2
4 - lineref3
5 - lineref4
6 - lineref5. |
| INT tnSyncEClkModState | 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.5 | INTEGER | read-only | The Sync-E clock mode state. |
| I32 tnSyncESystemQL | 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.6 | Integer32 | read-only | The value of the system quality level (SSM), shown
in following:
31 - not applicable
When the NE is in SDH mode:
0 - quality unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU.
When the NE is in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO. |
| tnSyncELineRefTable | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2 | | not-accessible | Table of VTS map. |
| tnSyncELineRefEntry | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1 | | not-accessible | |
| U32 tnSyncELineRefIndex | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.1 | Unsigned32 | not-accessible | The ifIndex of the line reference table. |
| INT tnSyncELineRefAssignedPort | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.2 | INTEGER | read-create | The assigned port for the line reference. |
| U32 tnSyncELineRefPriority | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.3 | Unsigned32 | read-create | Line reference priority.
Current configurable range: 0 to 8. |
| INT tnSyncELineRefAdminState | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.4 | INTEGER | read-create | The administrative state of the line reference. |
| INT tnSyncELineRefOperState | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.5 | INTEGER | read-only | The operating state of the line reference. |
| T/F tnSyncELineLockOut | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.6 | TruthValue | read-only | If lock out line reference or not. |
| INT tnSyncELineRefState | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.7 | INTEGER | read-only | The Sync-E line reference state. |
| INT tnSyncELineRefSwState | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.8 | INTEGER | read-only | The Sync-E line reference switch state. |
| I32 tnSyncELineRefIncSSMMsg | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.9 | Integer32 | read-only | This object indicates the current value of incoming
QL on that port.
30 - unstable
31 - not applicable
When the NE works in SDH mode:
0 - Unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
When the NE works in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
It's applicable only to the timing port with SSM
capabilities. |
| I32 tnSyncELineRefIncSSMStatus | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.10 | Integer32 | read-only | This object indicates the current status of incoming
QL on that port.
0: Valid
1: Invalid
2: Not Supported
3: Not Applicable
It's applicable only to the timing port with SSM
capabilities. |
| INT tnSyncELineRefIncSSMSupp | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.11 | INTEGER | read-create | Enable or disable the line reference incoming QL
processing. |
| I32 tnSyncELineRefProvQL | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.12 | Integer32 | read-create | Manually provisioned incoming SSM value for the line
reference. The value can be:
0 - AUTO
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
When the NE works in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
Note: The parameter can be provisioned only when
SyncELineRefIncSSMSupp is enabled. |
| NUM tnSyncELineRefAssociatedPort | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.13 | InterfaceIndexOrZero | read-create | The associated physical port of the line
reference. This parameter replaces
tnSyncELineRefAssignedPort in order to support
assigning a line reference to a port in other
slots. |
| U32 tnSyncELineRefPriorityOfStationClock | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.14 | Unsigned32 | read-create | Line reference priority for the output station
clock.
Current configurable range: 0 to 8. |
| T/F tnSyncELineRefLockOutOfStationClock | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.15 | TruthValue | read-only | If lock out the line reference or not for the
output station clock. |
| INT tnSyncELineRefSwStateOfStationClock | 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.16 | INTEGER | read-only | The Sync-E line reference switch state of the
output station clock. |
| tnSyncEControlTable | 1.3.6.1.4.1.7483.2.2.4.8.2.1.3 | | not-accessible | Table of Sync-E Control attributes. |
| tnSyncEControlEntry | 1.3.6.1.4.1.7483.2.2.4.8.2.1.3.1 | | not-accessible | |
| INT tnSyncEControlEECEnable | 1.3.6.1.4.1.7483.2.2.4.8.2.1.3.1.1 | INTEGER | read-create | enable - The Synchronous Ethernet is supported
for the pack and the synchronization
attributes can be configured.
disable - The Synchronous Ethernet is not supported
for the pack and the synchronization
attributes can not be configured. |
| tnSyncEPortTable | 1.3.6.1.4.1.7483.2.2.4.8.2.1.4 | | not-accessible | Table of Sync-E Port attributes. |
| tnSyncEPortEntry | 1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1 | | not-accessible | |
| INT tnSyncEOprMode | 1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1.1 | INTEGER | read-create | The port Synchronous Ethernet Operation Mode. When
the port is in SYNC mode, recovered clock of its
input signal can be selected as a reference clock
to the system clock. When the port is in NON-SYNC
mode, the recovered clock of its input signal shall
not be a candidate to system timing references. |
| INT tnSyncEOutgoingForceSsmTrans | 1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1.2 | INTEGER | read-create | The port SSM/Quality Level Transmission value.
The value can be:
In SDH mode - act, prc, ssua, ssub, sec, dnu,
none;
In sonet mode - act, stu, prs, st2, sts3e, st3,
dus, none. |
| tnSyncEStationClockTable | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5 | | not-accessible | Table of Sync-E station clock attributes. |
| tnSyncEStationClockEntry | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1 | | not-accessible | |
| T/F tnSyncEStationClockSyncMsg | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.1 | TruthValue | read-create | Determines if the timing reference selection for
station clock timing uses sync status messaging
(SSM Qualities). |
| INT tnSyncEStationClockActiveRef | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.2 | INTEGER | read-only | The ID of the association line reference. |
| U32 tnSyncEStationClockWTR | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.3 | Unsigned32 | read-create | The station clock timing WTR.
Current configurable range: 0 to 12, and 999999. |
| U32 tnSyncEStationClockSwCmdLineRef | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.4 | Unsigned32 | read-create | The third byte represents the switch command:
1 - nocmd
2 - clear
3 - lockout
4 - forceswitch
5 - mannual
6 - auto
7 - clearlockout.
The last byte represents the line reference switch to:
0 - internal
1 - lineref0
2 - lineref1
3 - lineref2
4 - lineref3
5 - lineref4
6 - lineref5. |
| I32 tnSyncEStationClockSystemQL | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.5 | Integer32 | read-only | The value of the system quality level (SSM) for
the output timing clock, shown in following:
31 - not applicable
When the NE is in SDH mode:
0 - quality unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU.
When the NE is in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO. |
| I32 tnSyncEStationClockQLThreshold | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.6 | Integer32 | read-create | Specifies the threshold value for the quality
level i.e., SSM value for squelching the output
towards timing output. If the quality value of
the current selected signal for the output is
below the threshold value, the output will be
squelched. The squelching can be disabled by
means of using the value DNU or DUS.
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU.
When the NE is in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS.
Default value:
SEC - for node working in SDH mode
ST3 - for node working in SONET mode |
| INT tnSyncEStationClockOutSel | 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.7 | INTEGER | read-create | Specifies which signal is selected for the output
station clock:
OUTTIM - Output is selected from output timing
selection process
SETG - Output is selected from system internal
timing The ID of the association line
reference. |
| tnSyncEBITSPortTable | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6 | | not-accessible | Table of BITS port attributes. |
| tnSyncEBITSPortEntry | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1 | | not-accessible | |
| INT tnSyncEBITSPortDirection | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.1 | INTEGER | read-only | Indicate the direction of the BITS port. |
| I32 tnSyncEBITSPortSignalType | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.2 | Integer32 | read-create | Specify the signal type for the BITS interface:
0 - 2MHz
1 - unframed E1
2 - framed E1 without SSM
3 - framed E1 with SSM
4 - DS1 SF
5 - DS1 ESF.
In SDH mode, 2MHz and E1 signal types are valid
and 2MHz is the default value. In SONET mode,
only the DS1 signal types are valid and DS1 SF
is the default value. |
| INT tnSyncEBITSPortSaBit | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.3 | INTEGER | read-create | Specifies the Sa bit location used to carry the
SSM information. This parameter is only
applicable when tnSyncEBITSPortSignalType = 3
(framed E1 with SSM) |
| INT tnSyncEBITSPortOutputSSMTrans | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.4 | INTEGER | read-create | The port SSM/Quality Level Transmission value.
The value can be:
In SDH mode - act, prc, ssua, ssub, sec,
dnu, none;
In sonet mode - act, stu, prs, st2, sts3e,
st3, dus, none.
Restriction: The parameter is only applicable
when tnSyncEBITSPortDirection = output and
tnSyncEBITSPortSignalType = 3 (framed E1 with
SSM)or 5 (DS1 ESF). |
| INT tnSyncEBITSPortOutputAISMode | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.5 | INTEGER | read-create | Specifies which signal is inserted for the timing
output port if the output signal is squelched.
The parameter is only applicable for output port
types supporting SSM.
AISMODE - AIS signal is inserted.
QLMODE - DUS is inserted as SSM; output is
squelched.
Restriction: The parameter is only applicable
when tnSyncEBITSPortDirection = output and
tnSyncEBITSPortSignalType = 3 (framed E1 with SSM)
or 5 (DS1 ESF). |
| INT tnSyncEBITSPortLineImpedance | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.6 | INTEGER | read-create | Nominal line impedance.
When in SDH mode, imp75ohms or imp120ohms could
be used and the default is imp120ohms. When in
ONET mode, imp100ohms could be used and the default
is imp100ohms. |
| INT tnSyncEBITSPortLineCode | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.7 | INTEGER | read-create | Line code. This attribute is applicable when
tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF. |
| INT tnSyncEBITSPortLbo | 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.8 | INTEGER | read-create | Line equalization value for the BITS output port,
taking one of the following values:
- lbo: no compensation
- lbo1: 0 to 133 feet
- lbo2: 133 to 266 feet
- lbo3: 267 to 399 feet
- lbo4: 400 to 533 feet
- lbo5: 534 to 655 feet
This attribute is applicable when tnSyncEBITSPortSignalType
is DS1 SF or DS1 ESF. |