TIMETRA-SDP-MIB :: sdpNumEntries

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsTIMETRA-SDP-MIBsdpNumEntries

sdpNumEntries

Module: TIMETRA-SDP-MIB

OID (symbolic): TIMETRA-SDP-MIB::sdpNumEntries

OID (numeric): 1.3.6.1.4.1.6527.3.1.2.4.4.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The current number of SDPs configured in this device.

What is sdpNumEntries?

This object shows the current count of Service Distribution Point (SDP) connections configured on the device, where an SDP represents a logical connection between network locations for service delivery. An operator would monitor this to understand the scale of service deployment and to verify that configuration changes have been properly loaded.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.4.4.1
snmpwalk -v2c -c public <target> TIMETRA-SDP-MIB::sdpNumEntries

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.4.4.1.1
snmpget -v2c -c public <target> TIMETRA-SDP-MIB::sdpNumEntries.1

Start monitoring Nokia/Alcatel-Lucent 7x50 Service Router platforms, entire product line (Service Distribution Point admin/oper status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-SDP-MIB::sdpNumEntries OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7x50 Service Router platforms, entire product line (Service Distribution Point admin/oper status) from a single console.

How to Use in IPNetwork Monitor

Select a Nokia/Alcatel-Lucent 7x50 Service Router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type sdpNumEntries into the Find box to locate it in the OID tree, then select it and click OK. It reports the current number of Service Distribution Points (SDPs) configured on this device. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate an SDP was added or removed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2tmnxSRObjsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2.4tmnxServObjsALCATEL-IND1-TIMETRA-SERV-MIB
1.3.6.1.4.1.6527.3.1.2.4.4tmnxSdpObjsALCATEL-IND1-TIMETRA-SDP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.2.4.4.1sdpNumEntriesTIMETRA-SDP-MIB