TIMETRA-SDP-MIB :: sdpBindTlsBlockOnMeshFail

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsTIMETRA-SDP-MIBsdpBindTlsBlockOnMeshFail

sdpBindTlsBlockOnMeshFail

Module: TIMETRA-SDP-MIB

OID (symbolic): TIMETRA-SDP-MIB::sdpBindTlsBlockOnMeshFail

OID (numeric): 1.3.6.1.4.1.6527.3.1.2.4.4.6.1.49

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: The value of sdpBindTlsBlockOnMeshFail specifies that the operational status of this spoke SDP will consider operational status of associated mesh SDPs in this service.

If there are no mesh SDPs in the service, value of this object is ignored.

When this object is set to 'true', then the operational status of this spoke SDP will be 'down' until the operational status of atleast one mesh SDP in this service is 'up'.

When set to 'false', the operational status of this spoke SDP does not consider the operational status of any mesh SDPs in the service.

What is sdpBindTlsBlockOnMeshFail?

This boolean object controls whether a spoke Service Distribution Point (SDP) binding should become operationally down if associated mesh SDPs in the same service fail. When set to true, the spoke SDP dependency on mesh SDP health ensures synchronization of service topology; when false, the spoke operates independently of mesh SDP status. Operators use this to coordinate failover behavior across multi-point service topologies.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.4.4.6.1.49
snmpwalk -v2c -c public <target> TIMETRA-SDP-MIB::sdpBindTlsBlockOnMeshFail

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.4.4.6.1.49.1
snmpget -v2c -c public <target> TIMETRA-SDP-MIB::sdpBindTlsBlockOnMeshFail.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6527.3.1.2.4.4.6.1.49.1 s <value>

Start monitoring Nokia/Alcatel-Lucent 7x50 Service Router platforms, entire product line (Service Distribution Point admin/oper status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-SDP-MIB::sdpBindTlsBlockOnMeshFail OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7x50 Service Router platforms, entire product line (Service Distribution Point admin/oper status) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2tmnxSRObjsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2.4tmnxServObjsALCATEL-IND1-TIMETRA-SERV-MIB
1.3.6.1.4.1.6527.3.1.2.4.4tmnxSdpObjsALCATEL-IND1-TIMETRA-SDP-MIB
1.3.6.1.4.1.6527.3.1.2.4.4.6sdpBindTlsTableALCATEL-IND1-TIMETRA-SDP-MIB
1.3.6.1.4.1.6527.3.1.2.4.4.6.1sdpBindTlsEntryALCATEL-IND1-TIMETRA-SDP-MIB
Numeric OIDNameModule