TIC-RMTI4-G9000-G2020-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TIC-RMTI4-G9000-G2020-MIB

Category: Industrial and Sensor Devices

Description: Manages TIC RMTI4 industrial gateway configuration, I/O interfaces, and operational state.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is TIC-RMTI4-G9000-G2020-MIB?

Based on its object set, this module manages a Toshiba-brand uninterruptible power supply (UPS), sitting under an equ/equUPS enterprise branch, rather than the industrial gateway its name might suggest. It exposes UPS identification data — manufacturer, type/form, firmware version, system name, and attached devices — alongside AC input power measurements, specifically three-phase line-to-line voltages and their percentage of nominal. It is explicitly used to monitor UPS hardware and firmware status: confirming the installed firmware version for inventory/compliance, and tracking per-phase input voltage and percent-of-nominal values to catch abnormal utility power feeding the UPS before it affects protected equipment. Its object naming closely follows the structure of the standard UPS-MIB (RFC 1628) conventions (upsIdent*, upsInput*), suggesting it was derived from or is closely aligned with that standard. It is typically deployed in a data center or equipment room where the UPS protects critical networking or industrial gateway hardware, polled by facilities or NMS systems for power-quality monitoring. Engineers can download the TIC-RMTI4-G9000-G2020-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in TIC-RMTI4-G9000-G2020-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Toshiba UPS (uninterruptible power supply)

Monitoring Examples

upsIdentManufacturer and upsIdentUPSFirmwareVersion let an administrator confirm the UPS vendor and firmware revision during an equipment audit, while upsInputLLVoltageAB, upsInputLLVoltageBC, and upsInputLLVoltageCA report the three-phase line-to-line input voltages, paired with upsInputLLVoltagePercentAB/BC/CA expressing each as a percentage of nominal. An operator would alert when any percent-of-nominal value falls outside an expected band, signaling a utility power sag or surge upstream of the UPS, and would check upsIdentAttachedDevices to see which downstream equipment depends on that UPS.

What Can Be Monitored

  • UPS manufacturer/model identification
  • firmware version
  • attached device list
  • input voltage per phase (AB/BC/CA)
  • input voltage percent of nominal per phase
  • number of input phases
Imported Objects

From RFC-1212

OBJECT-TYPE

From RFC-1215

TRAP-TYPE

From RFC1155-SMI

Gauge32
Integer32
enterprises

From SNMPv2-TC

AutonomousType
DisplayString
TestAndIncr
TimeInterval
TimeStamp
OIDs

RFC description

Telecommunications management MIB for remote monitoring and testing of TIC infrastructure on G9000/G2020 platforms.

Start monitoring Toshiba UPS, uninterruptible power supply (firmware/AC input voltage status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download TIC-RMTI4-G9000-G2020-MIB