All MIBs › Th2e-v01-MIB
Category: Industrial and Sensor Devices
Description: Manages HWg Th2e temperature and humidity sensor readings and alarm thresholds.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is Th2e-v01-MIB?
This module manages the HWg (Papouch/HW group) Th2e, a small SNMP-enabled sensor device that measures temperature and humidity and can drive alarm outputs based on configurable thresholds. It exposes per-channel sensor readings and units, alarm limit configuration (high, low, and hysteresis), device naming, and an alarm/status string, along with versioning information. Its core purpose is hardware condition monitoring — specifically environmental monitoring: it reports current temperature/humidity channel values and whether they have crossed configured high/low alarm thresholds, which is the entire function of this device class (typically deployed to watch server-room or equipment-cabinet climate). It has no dependency on other vendor MIBs beyond standard SNMP conventions (it originates from the Papouch "papouchProjekt" enterprise branch) and is a self-contained small-sensor MIB. It is typically deployed in server rooms, network closets, or equipment cabinets as a compact environmental monitoring probe feeding temperature/humidity alarms into a broader NMS. Engineers can download the Th2e-v01-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in Th2e-v01-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- HWg (Papouch) Th2e temperature/humidity sensor unit
Monitoring Examples
An administrator would poll the per-channel inChValue and inChUnits objects (via the channel table, similar to inChStatus entries) to read current temperature and humidity readings, and check inChStatus alongside the limitHi/limitLo/limitHy threshold objects to see whether a channel is in alarm; the psAlarmString object would surface a human-readable description of the active alarm condition (e.g., over-temperature in a server cabinet), and deviceName identifies which physical sensor unit reported it.
What Can Be Monitored
- temperature reading per channel
- humidity reading per channel
- channel alarm status
- high/low/hysteresis alarm thresholds
- active alarm description string
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| IpAddress | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString |
How to Use in IPNetwork Monitor
Example using inChStatus OID:
OIDs
RFC description
Monitors sensor data and channel status for TH2E temperature/humidity monitoring devices.
Start monitoring HWg (Papouch) Th2e temperature/humidity sensor unit (channel reading/alarm-threshold status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.