TIC-RMTI4-G9000-G2020-MIB :: upsConfigRatedInputFrequency

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TIC-RMTI4-G9000-G2020-MIB › upsConfigRatedInputFrequency

upsConfigRatedInputFrequency

Module: TIC-RMTI4-G9000-G2020-MIB

OID (symbolic): TIC-RMTI4-G9000-G2020-MIB::upsConfigRatedInputFrequency

OID (numeric): 1.3.6.1.4.1.186.1.19.2.5.1.7.4

Node type: OBJECT-TYPE

Type: NonNegativeInteger

Access: read-only

Description: The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.

What is upsConfigRatedInputFrequency?

Reports the UPS's nominal input frequency in tenths of a hertz (e.g. 500 = 50.0 Hz). This tells admins what input frequency the UPS expects from utility power.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.186.1.19.2.5.1.7.4
snmpwalk -v2c -c public <target> TIC-RMTI4-G9000-G2020-MIB::upsConfigRatedInputFrequency

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.186.1.19.2.5.1.7.4.1
snmpget -v2c -c public <target> TIC-RMTI4-G9000-G2020-MIB::upsConfigRatedInputFrequency.1

Start monitoring Toshiba UPS, uninterruptible power supply (firmware/AC input voltage status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIC-RMTI4-G9000-G2020-MIB::upsConfigRatedInputFrequency OID value, configure state conditions and alerts, and monitor any Toshiba UPS, uninterruptible power supply (firmware/AC input voltage status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.186toshibaTIC-RMTI4-G9000-G2020-MIB
1.3.6.1.4.1.186.1equTIC-RMTI4-G9000-G2020-MIB
1.3.6.1.4.1.186.1.19equUPSTIC-RMTI4-G9000-G2020-MIB
1.3.6.1.4.1.186.1.19.2ticUPSTIC-RMTI4-G9000-G2020-MIB
1.3.6.1.4.1.186.1.19.2.5rmti4TIC-RMTI4-G9000-G2020-MIB
1.3.6.1.4.1.186.1.19.2.5.1upsG9000_G2020TIC-RMTI4-G9000-G2020-MIB
1.3.6.1.4.1.186.1.19.2.5.1.7upsConfigTIC-RMTI4-G9000-G2020-MIB
1.3.6.1.4.1.186.1.19.2.5.1.7.4upsConfigRatedInputFrequencyTIC-RMTI4-G9000-G2020-MIB