| OID symbolic | OID numeric | Type | Access | Description |
| sonusSystemTimingMIB | 1.3.6.1.4.1.2879.2.1.3 | | | The MIB Module for System Timing management. |
| sonusSystemTimingMIBObjects | 1.3.6.1.4.1.2879.2.1.3.1 | | | |
| sonusStShelfAdmnTable | 1.3.6.1.4.1.2879.2.1.3.1.1 | | not-accessible | |
| sonusStShelfAdmnEntry | 1.3.6.1.4.1.2879.2.1.3.1.1.1 | | not-accessible | |
| SON sonusStShelfAdmnShelfIndex | 1.3.6.1.4.1.2879.2.1.3.1.1.1.1 | SonusShelfIndex | read-only | Identifies the target shelf within the node. |
| I32 sonusStShelfAdmnFailoverGuardTime | 1.3.6.1.4.1.2879.2.1.3.1.1.1.2 | Integer32 | read-write | Indicates how long a timing source can be faulting
before switchover to another source is initiated |
| I32 sonusStShelfAdmnRecoveryGuardTime | 1.3.6.1.4.1.2879.2.1.3.1.1.1.3 | Integer32 | read-write | Indicates how long a timing source must be valid for, after
it has faulted, before it will be considered valid again. |
| INT sonusStShelfAdmnTransmitRemoteAlarm | 1.3.6.1.4.1.2879.2.1.3.1.1.1.4 | INTEGER | read-write | Not Supported |
| INT sonusStShelfAdmnRevertRefSwitching | 1.3.6.1.4.1.2879.2.1.3.1.1.1.5 | INTEGER | read-write | If enabled, then a timing source which has failed, but then
becomes valid again, will be reconsidered for use.
If disabled, then once a timing source fails, it will never
be automatically reconsidered for use. To use the source again
requires manual user intervention. |
| INT sonusStShelfAdmnRevertMtaSwitching | 1.3.6.1.4.1.2879.2.1.3.1.1.1.6 | INTEGER | read-write | If enabled, then an MTA which is hot-inserted will
automatically be brought on line and made available for use.
If disabled, then an MTA which is hot-inserted will require
manual user configuration before being available for use. |
| I32 sonusStShelfAdmnRevertInsertDelay | 1.3.6.1.4.1.2879.2.1.3.1.1.1.7 | Integer32 | read-write | MTA warm-up period. When an MTA is hot-inserted, the card
will be allowed to warm up and stabilize for this amount
of time before being put back into service.
This warm-up period is also used during cold start of a shelf. |
| INT sonusStShelfAdmnFreeRunAlarm | 1.3.6.1.4.1.2879.2.1.3.1.1.1.8 | INTEGER | read-write | Not Supported |
| INT sonusStShelfAdmnTimingSourceAction | 1.3.6.1.4.1.2879.2.1.3.1.1.1.9 | INTEGER | read-write | Resequence will cause the timing sequence list to be re-evaluated.
This may cause the current active timing source to change. |
| ROW sonusStShelfAdmnRowStatus | 1.3.6.1.4.1.2879.2.1.3.1.1.1.10 | RowStatus | read-write | This object indicates the row status for this table. |
| INT sonusStShelfAdmnSourceReconfigAlg | 1.3.6.1.4.1.2879.2.1.3.1.1.1.11 | INTEGER | read-write | This object indicates which algorithm should be used to select timing sources
for use as System Synchronized sources. Selecting Ordered_list causes sources
to be selected for use in strict numerical order, as assigned by default or by
the operator. Selecting SSM_Quality will cause sources to be selected based upon
the quality level of the timing source, as indicated by the sources Synchronized
Status Messages.
Do not select SSM_Quality unless all configured timing sources support SSM's |
| INT sonusStShelfAdmnMtaSourceAffinity | 1.3.6.1.4.1.2879.2.1.3.1.1.1.12 | INTEGER | read-write | This object works in conjunction with the Source Reconfiguration Algorithm object.
If sticky is selected, System Timing Manager will exhaust oll timing sources on an
MTA at all quality levels before selecting a timing source on the alternate MTA.
If none is selected, timing sources will be chosen based on stratum quality only,
reguardless of which MTA is providing the source.
This object has no effect when the Source Reconfiguration Algorithm is set to Ordered_list. |
| sonusStShelfStatTable | 1.3.6.1.4.1.2879.2.1.3.1.2 | | not-accessible | |
| sonusStShelfStatEntry | 1.3.6.1.4.1.2879.2.1.3.1.2.1 | | not-accessible | |
| SON sonusStShelfStatShelfIndex | 1.3.6.1.4.1.2879.2.1.3.1.2.1.1 | SonusShelfIndex | read-only | |
| SON sonusStShelfStatActiveMtaSlot | 1.3.6.1.4.1.2879.2.1.3.1.2.1.2 | SonusMtaSlotIndex | read-only | Identifies which MTA is providing the System Synchronized Timing signal. |
| SON sonusStShelfStatActiveSource | 1.3.6.1.4.1.2879.2.1.3.1.2.1.3 | SonusTimingSource | read-only | Identifies what timing source the active MTA is
using to provide System Synchronized Timing. |
| sonusStMtaAdmnTable | 1.3.6.1.4.1.2879.2.1.3.1.3 | | not-accessible | |
| sonusStMtaAdmnEntry | 1.3.6.1.4.1.2879.2.1.3.1.3.1 | | not-accessible | |
| SON sonusStMtaAdmnShelfIndex | 1.3.6.1.4.1.2879.2.1.3.1.3.1.1 | SonusShelfIndex | read-only | Identifies the target shelf within the node. |
| SON sonusStMtaAdmnMtaSlotIndex | 1.3.6.1.4.1.2879.2.1.3.1.3.1.2 | SonusMtaSlotIndex | read-only | Identifies the target slot within the shelf. |
| SON sonusStMtaAdmnState | 1.3.6.1.4.1.2879.2.1.3.1.3.1.3 | SonusAdminState | read-write | If enabled, the MTA can participate in system timing.
If disabled, then it will be removed from service and
not allowed to participate. All timing sequence entries
bound to this node will be marked as out of service.
In a non-redundant configuration the MTA admin state
cannot be disabled. |
| INT sonusStMtaAdmnLineEncoding | 1.3.6.1.4.1.2879.2.1.3.1.3.1.4 | INTEGER | read-write | Select AMI or B8ZS line coding for BITS LIU.
Select HDB3 for SETS LIU |
| INT sonusStMtaAdmnSsmChannelBit | 1.3.6.1.4.1.2879.2.1.3.1.3.1.5 | INTEGER | read-write | MTA 20, E1 support only. Identifies which of the additional spare
bits, embedded within the framing pattern, contains the SSM channel |
| INT sonusStMtaAdmnFramerMode | 1.3.6.1.4.1.2879.2.1.3.1.3.1.6 | INTEGER | read-write | Select ESF or D4/SF for BITS framer.
ESF should be selected if B8ZS has been selected for the line encoding.
D4/SF should be selected if AMI has been selected for the line encoding.
Select MF or MF-CRC4 for SETS framer |
| INT sonusStMtaAdmnFramerTransmitYellowAlarm | 1.3.6.1.4.1.2879.2.1.3.1.3.1.7 | INTEGER | read-write | Not supported |
| INT sonusStMtaAdmnLiuTransmitAllOnes | 1.3.6.1.4.1.2879.2.1.3.1.3.1.8 | INTEGER | read-write | Not supported |
| INT sonusStMtaAdmnAction | 1.3.6.1.4.1.2879.2.1.3.1.3.1.9 | INTEGER | read-write | Selecting AVAILABLE will cause the MTA to be moved from
the Out-Of-Service state to the Available-For-Use state.
This command is necessary to manually make an MTA available for use
after it has failed, and revertive MTA switching is not enabled.
This may cause the current active timing source to change. |
| ROW sonusStMtaAdmnRowStatus | 1.3.6.1.4.1.2879.2.1.3.1.3.1.10 | RowStatus | read-write | This object indicates the row status for this table. |
| sonusStMtaStatTable | 1.3.6.1.4.1.2879.2.1.3.1.4 | | not-accessible | |
| sonusStMtaStatEntry | 1.3.6.1.4.1.2879.2.1.3.1.4.1 | | not-accessible | |
| SON sonusStMtaStatShelfIndex | 1.3.6.1.4.1.2879.2.1.3.1.4.1.1 | SonusShelfIndex | read-only | |
| SON sonusStMtaStatMtaSlotIndex | 1.3.6.1.4.1.2879.2.1.3.1.4.1.2 | SonusMtaSlotIndex | read-only | |
| INT sonusStMtaStatOperStat | 1.3.6.1.4.1.2879.2.1.3.1.4.1.3 | INTEGER | read-only | Indicates the operational status of the MTA |
| STR sonusStMtaStatMtaHwDesc | 1.3.6.1.4.1.2879.2.1.3.1.4.1.4 | DisplayString | read-only | Description of the MTA hardware in the form of 'hwtype_hwRev'. |
| HWT sonusStMtaStatMtaHwType | 1.3.6.1.4.1.2879.2.1.3.1.4.1.5 | HwTypeID | read-only | Description of the MTA hardware Type only. Entry 5+6 obsolete entry 4. |
| I32 sonusStMtaStatMtaHwTypeRev | 1.3.6.1.4.1.2879.2.1.3.1.4.1.6 | Integer32 | read-only | Description of the MTA hardware type revision. Entry 5+6 obsolete entry 4. |
| STR sonusStMtaStatMtaSerialNum | 1.3.6.1.4.1.2879.2.1.3.1.4.1.7 | DisplayString | read-only | Identifies the serial number of the server module.
This is the serial number assigned to the mta module in manufacturing. |
| STR sonusStMtaStatMtaPartNum | 1.3.6.1.4.1.2879.2.1.3.1.4.1.8 | DisplayString | read-only | Identifies the part number of the server module.
This is the part number assigned to the mta module in manufacturing. |
| sonusStTimingSourceTable | 1.3.6.1.4.1.2879.2.1.3.1.5 | | not-accessible | |
| sonusStTimingSourceEntry | 1.3.6.1.4.1.2879.2.1.3.1.5.1 | | not-accessible | |
| SON sonusStTimingSourceShelfIndex | 1.3.6.1.4.1.2879.2.1.3.1.5.1.1 | SonusShelfIndex | read-write | |
| I32 sonusStTimingSourceMtaSlotIndex | 1.3.6.1.4.1.2879.2.1.3.1.5.1.2 | Integer32 | read-write | Indicates which MTA this timing node is bound to. |
| SON sonusStTimingSource | 1.3.6.1.4.1.2879.2.1.3.1.5.1.3 | SonusTimingSource | read-write | Indicates which physical timing source is bound to this node.
External BITS sources are used by MTA 10's, in T1 based chassis'.
External SETS sources are used by MTA 2X's, in E1 based chassis'.
REFCLK's are based upon timing recovered from a CNS or PNS Server card.
HOLDOVER mimics the last known good source before it failed.
OSCILLATOR is used when no other valid sources exist on the currently active
MTA. |
| SON sonusStTimingSourceState | 1.3.6.1.4.1.2879.2.1.3.1.5.1.4 | SonusAdminState | read-write | If enabled, the source can participate in system timing.
If disabled, then it will be removed from service and
not be allowed to participate. |
| I32 sonusStTimingSourceSequenceNum | 1.3.6.1.4.1.2879.2.1.3.1.5.1.5 | Integer32 | read-write | The timing sequence number is automatically generated |
| INT sonusStTimingSourceAction | 1.3.6.1.4.1.2879.2.1.3.1.5.1.6 | INTEGER | read-write | Selecting AVAILABLE will cause the timing source to be moved
from the Out-Of-Service state to the Available-For-Use state.
This command is necessary to manually make a source available for use
after it has failed, and revertive source switching is not enabled.
This may cause the current active timing source to change. |
| ROW sonusStTimingSourceRowStatus | 1.3.6.1.4.1.2879.2.1.3.1.5.1.7 | RowStatus | read-write | This object indicates the row status for this table. |
| sonusStTimingSourceStatTable | 1.3.6.1.4.1.2879.2.1.3.1.6 | | not-accessible | |
| sonusStTimingSourceStatEntry | 1.3.6.1.4.1.2879.2.1.3.1.6.1 | | not-accessible | |
| SON sonusStTimingSourceStatShelfIndex | 1.3.6.1.4.1.2879.2.1.3.1.6.1.1 | SonusShelfIndex | read-only | Indicates shelf. |
| SON sonusStTimingSourceStatMtaSlotIndex | 1.3.6.1.4.1.2879.2.1.3.1.6.1.2 | SonusMtaSlotIndex | read-only | Indicates which MTA this timing node is bound to. |
| SON sonusStTimingSourceStat | 1.3.6.1.4.1.2879.2.1.3.1.6.1.3 | SonusTimingSource | read-only | Indicates the physical timing source |
| INT sonusStTimingSourceStatState | 1.3.6.1.4.1.2879.2.1.3.1.6.1.4 | INTEGER | read-only | Indicates the current overall state of the timing source, including
the hardware state, adminitrative mode and shelf configuration |
| INT sonusStTimingSourceStatTraceability | 1.3.6.1.4.1.2879.2.1.3.1.6.1.5 | INTEGER | read-only | Indicates the Quality Level of the System Synchronized Timing Source |
| INT sonusStTimingSourceStatLineState | 1.3.6.1.4.1.2879.2.1.3.1.6.1.6 | INTEGER | read-only | Indicates the current physical status of the timing source |
| sonusStChannelBindingTable | 1.3.6.1.4.1.2879.2.1.3.1.7 | | not-accessible | This table describes how derived timing
sources should be mapped to the MTA hardware |
| sonusStChannelBindingEntry | 1.3.6.1.4.1.2879.2.1.3.1.7.1 | | not-accessible | |
| SON sonusStChannelBindingShelfIndex | 1.3.6.1.4.1.2879.2.1.3.1.7.1.1 | SonusShelfIndex | read-only | |
| SON sonusStChannelBindingSlotIndex | 1.3.6.1.4.1.2879.2.1.3.1.7.1.2 | SonusSlotIndex | read-only | Server slot number to provide a recovered clock source. The
same server can be configured to provide both possible recovered
clocks as long as different channels(spans) are selected, and
the REFCLK each is bound to differs |
| I32 sonusStChannelBindingChannel | 1.3.6.1.4.1.2879.2.1.3.1.7.1.3 | Integer32 | read-only | T1/E1 span or OC12 port number to provide the recovered clock source.
T1 span range is 1-12(CNS10), 1-28(CNS30), E1 span range is 1-8(CNS20),
OC12 port number(PNS20) is 1 only. |
| INT sonusStChannelBindingRefClk | 1.3.6.1.4.1.2879.2.1.3.1.7.1.4 | INTEGER | read-only | Backplane signal the recovered clock source should be
bound to. Each REFCLK must only be bound to a single
Server slot/span. |
| ROW sonusStChannelBindingRowStatus | 1.3.6.1.4.1.2879.2.1.3.1.7.1.5 | RowStatus | read-write | This object indicates the row status for this table. |
| sonusSystemTimingMIBNotifications | 1.3.6.1.4.1.2879.2.1.3.2 | | | |
| sonusSystemTimingMIBNotificationsPrefix | 1.3.6.1.4.1.2879.2.1.3.2.0 | | | |
| NTF sonusSystemTimingActiveFailedNotification | 1.3.6.1.4.1.2879.2.1.3.2.0.1 | | | This trap indicates that the currently
active System Timing clock source has failed. |
| NTF sonusSystemTimingActiveSwitchoverNotification | 1.3.6.1.4.1.2879.2.1.3.2.0.2 | | | This trap indicates that the active System Timing
clock source has been switched to another source. |
| NTF sonusSystemTimingOscillatorActiveNotification | 1.3.6.1.4.1.2879.2.1.3.2.0.3 | | | This trap indicates that all external sources of
System Timing have failed and that the current
source of timing is the MTA's internal oscillator. |
| NTF sonusSystemTimingMTAFailedNotification | 1.3.6.1.4.1.2879.2.1.3.2.0.4 | | | This trap indicates that the MTA indicated
has failed or been removed from the shelf. |
| NTF sonusSystemTimingMTAOperationalNotification | 1.3.6.1.4.1.2879.2.1.3.2.0.6 | | | This trap indicates that the specified MTA
is now operational. |
| NTF sonusSystemTimingMTATotalFailureNotification | 1.3.6.1.4.1.2879.2.1.3.2.0.7 | | | This trap indicates that no MTA's are available for
use to provide System Timing. They have either failed,
been removed from service or been removed from the shelf.
The shelf is no longer capable of being properly timed.
Downstream Shelves or other equipment connected to this shelf's
MITDC(Marlin Inter-chassis Timing Daisy Chain) may be affected. |
| sonusSystemTimingMIBNotificationsObjects | 1.3.6.1.4.1.2879.2.1.3.2.1 | | | |
| SON sonusTimingSource | 1.3.6.1.4.1.2879.2.1.3.2.1.1 | SonusTimingSource | read-only | |
| STR sonusTimingSource2 | 1.3.6.1.4.1.2879.2.1.3.2.1.2 | SonusEventString | read-only | |