SONUS-SYSTEM-TIMING-MIB :: sonusStMtaAdmnAction

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SONUS-SYSTEM-TIMING-MIB › sonusStMtaAdmnAction

sonusStMtaAdmnAction

Module: SONUS-SYSTEM-TIMING-MIB

OID (symbolic): SONUS-SYSTEM-TIMING-MIB::sonusStMtaAdmnAction

OID (numeric): 1.3.6.1.4.1.2879.2.1.3.1.3.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Selecting AVAILABLE will cause the MTA to be moved from the Out-Of-Service state to the Available-For-Use state.

This command is necessary to manually make an MTA available for use after it has failed, and revertive MTA switching is not enabled.

This may cause the current active timing source to change.

What is sonusStMtaAdmnAction?

Setting this to available(2) moves the MTA from the Out-Of-Service state to Available-For-Use; the DESCRIPTION notes this is the manual step needed to bring an MTA back after a failure when revertive MTA switching (sonusStShelfAdmnRevertMtaSwitching) is disabled, and may change the currently active timing source. An admin uses this to manually recover a failed MTA into service rather than waiting on (or having disabled) automatic reversion.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2879.2.1.3.1.3.1.9
snmpwalk -v2c -c public <target> SONUS-SYSTEM-TIMING-MIB::sonusStMtaAdmnAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2879.2.1.3.1.3.1.9.1
snmpget -v2c -c public <target> SONUS-SYSTEM-TIMING-MIB::sonusStMtaAdmnAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2879.2.1.3.1.3.1.9.1 i <value>

Start monitoring Sonus Networks softswitch, Sonus media gateway shelf (clock-reference/free-run alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SONUS-SYSTEM-TIMING-MIB::sonusStMtaAdmnAction OID value, configure state conditions and alerts, and monitor any Sonus Networks softswitch, Sonus media gateway shelf (clock-reference/free-run alarm status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2879sonusSONUS-SMI
1.3.6.1.4.1.2879.2sonusMgmtSONUS-SMI
1.3.6.1.4.1.2879.2.1sonusSystemMIBsSONUS-SMI
Numeric OIDNameModule
1.3.6.1.4.1.2879.2.1.3sonusSystemTimingMIBSONUS-SYSTEM-TIMING-MIB
1.3.6.1.4.1.2879.2.1.3.1sonusSystemTimingMIBObjectsSONUS-SYSTEM-TIMING-MIB
1.3.6.1.4.1.2879.2.1.3.1.3sonusStMtaAdmnTableSONUS-SYSTEM-TIMING-MIB
1.3.6.1.4.1.2879.2.1.3.1.3.1sonusStMtaAdmnEntrySONUS-SYSTEM-TIMING-MIB
1.3.6.1.4.1.2879.2.1.3.1.3.1.9sonusStMtaAdmnActionSONUS-SYSTEM-TIMING-MIB