All MIBs › SDH-ETS-MIB
Organization: SAGEM-Tolbiac drd/ddp/tmhd
Last Updated: 2002-05-22
Category: Microwave Radio - SAGEM
Description:
Manages SAGEM SDH synchronous transport equipment configuration and performance monitoring.
Imported Objects
From EQUIPMENT-MIB
| SagemBoolean | |
| Severity |
From SAGEM-DR-MIB
| sagemDr | MODULE-IDENTITY |
From SNMPv2-SMI
| MODULE-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString |
What Is SDH-ETS-MIB?
SDH-ETS-MIB is a SAGEM-Tolbiac (drd/ddp/tmhd division) proprietary MIB (per ETSI ETS 300 304, built on EQUIPMENT-MIB/SAGEM-DR-MIB, referenced by XCON-MIB for cross-connections) defining the SDH transmission portion of network-element equipment. Its SPI (SDH Physical Interface) TTP (Trail Termination Point) table, keyed by index, records STM level, type, name, board index/access, monitor/failure/severity settings, loopback, LOS (Loss of Signal), and TF (Transmission Failure), while a companion RS (Regenerator Section) TTP table records monitor/name/failure/severity, EOW mode, and E1/F1 source pointers. As a status/configuration MIB it lets an administrator confirm SDH termination-point alarm severity and loopback state on a SAGEM SDH network element. It is deployed on SAGEM-Tolbiac SDH transmission network-element equipment. Engineers can download the SDH-ETS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in SDH-ETS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- SDH termination-point alarm severity and loopback state
Supported Devices
- SAGEM-Tolbiac SDH transmission network-element equipment
Monitoring Examples
An administrator checks spiTTPFailure and spiTTPLos to diagnose a signal-loss condition on a SAGEM SDH network element's termination point.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| sdhEts | 1.3.6.1.4.1.1038.110 | The MIB module defines SDH transmition part of an equipment This MIB use the logical model defined in ETSI ETS 300 304. ETS 300 304 (February 1997) defines the SDH information model for the Network Element. This MIB refers to SHELF-MIB for the definition of the Board that supports the interface. This MIB is refered by XCON-MIB that uses the definition of termination point to create cross connection. This MIB also define configuration of the different SDH blocs such as alarm monitoring and severity and give the current status of the termination point. | ||
| spiTTP | 1.3.6.1.4.1.1038.110.10 | |||
| INT spiTTPNumber | 1.3.6.1.4.1.1038.110.10.1 | INTEGER | read-only | Number of synchronous physical interface in equipment = number of element in spiTTPTable |
| spiTTPTable | 1.3.6.1.4.1.1038.110.10.2 | not-accessible | List of synchronous physical interface in equipment. | |
| spiTTPEntry | 1.3.6.1.4.1.1038.110.10.2.1 | not-accessible | A particular synchronous physical interface of the equipment. | |
| INT spiTTPIndex | 1.3.6.1.4.1.1038.110.10.2.1.1 | INTEGER | read-only | A unique value which identify a particular synchronous physical interface. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware. Exemple: For ADR155c equipement index are 1,64,127,190 for STM1 interfaces. For ADR2500c equipement index are: 1,1009,2017,3025,4033,5041,6049,7057 for 8 STM16 or 8 STM4, 1,253,505,757 1009,1261,1513,1765 | 2017,2269,2521,2773 3025,3277,3529,3781 | --> for 8 (4*STM1) 4033,4285,4537,4789 5041,5293,5545,5797 | 6049,6301,6553,6805 7057,7309,7561,7813 | |
| STM spiTTPStmLevel | 1.3.6.1.4.1.1038.110.10.2.1.2 | STMLevel | read-only | The STM-n level of the interface. |
| SPI spiTTPType | 1.3.6.1.4.1.1038.110.10.2.1.3 | SpiTTPType | read-only | The kind of the interface: electrical or optical |
| STR spiTTPName | 1.3.6.1.4.1.1038.110.10.2.1.4 | DisplayString | read-write | A text string which identifies the particular entry among the synchronous physical interface entries. |
| INT spiTTPBoardIndex | 1.3.6.1.4.1.1038.110.10.2.1.5 | INTEGER | read-only | Index of the Board that supports the physical acces of this interface. This index refers to another MIB that defines the board |
| INT spiTTPBoardAcces | 1.3.6.1.4.1.1038.110.10.2.1.6 | INTEGER | read-only | Friendly Index of the physical acces on the Board that supports the interface |
| SAG spiTTPMonitor | 1.3.6.1.4.1.1038.110.10.2.1.7 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this synchronous physical interface. |
| SPI spiTTPFailure | 1.3.6.1.4.1.1038.110.10.2.1.8 | SpiTTPFailure | read-only | Active failures on synchronous physical interface |
| SEV spiTTPSeverity | 1.3.6.1.4.1.1038.110.10.2.1.9 | Severity | read-only | Severity associed with active failure for synchronous physical interface. |
| LOO spiTTPLoopback | 1.3.6.1.4.1.1038.110.10.2.1.10 | Loopback | read-write | This field gives the active loopback status on the synchronous physical interface. When its value is `line' the data flow recieved from the port side is sent back to the line. When its value is `equipment' the data flow recieved form equipment side is send back. The field can be set to a particular loopback value, even if there no garantee that the loopback is really done. The real loopback status of the interface must be checked in the response. The loopback can be cleared by the equipment when it cannot remain for any reason. |
| SEV spiTTPLos | 1.3.6.1.4.1.1038.110.10.2.1.20 | Severity | read-write | Severity associed with Loss Of Signal failure for synchronous physical interface. |
| SEV spiTTPTf | 1.3.6.1.4.1.1038.110.10.2.1.21 | Severity | read-write | Severity associed with Tranmit Fail failure for synchronous physical interface. |
| rsTTP | 1.3.6.1.4.1.1038.110.20 | |||
| rsTTPTable | 1.3.6.1.4.1.1038.110.20.2 | not-accessible | List of regenerator section terminaison in equipment. | |
| rsTTPEntry | 1.3.6.1.4.1.1038.110.20.2.1 | not-accessible | A particular regenerator section terminaison of the equipment. | |
| INT rsTTPIndex | 1.3.6.1.4.1.1038.110.20.2.1.1 | INTEGER | read-only | A unique value which identify a particular synchronous physical interface. The value of this index is always the same as spiTTPIndex. |
| SAG rsTTPMonitor | 1.3.6.1.4.1.1038.110.20.2.1.2 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this regenerator section terminaison. |
| STR rsTTPName | 1.3.6.1.4.1.1038.110.20.2.1.3 | DisplayString | read-write | A text string which identifies the particular entry among the regenerator section terminaison entries. |
| RST rsTTPFailure | 1.3.6.1.4.1.1038.110.20.2.1.4 | RsTTPFailure | read-only | Active failures on regenerator section terminaison |
| SEV rsTTPSeverity | 1.3.6.1.4.1.1038.110.20.2.1.5 | Severity | read-only | Severity associed active Failure for regenerator section terminaison. |
| EOW rsTTPEOWMode | 1.3.6.1.4.1.1038.110.20.2.1.8 | EOWMode | read-only | Mode used for EOW: Codir or contradir Master |
| INT rsTTPE1SrcPointer | 1.3.6.1.4.1.1038.110.20.2.1.9 | INTEGER | read-only | A reference to the object which sends the data flow to E1 RSOH byte (index in X21 table) Usualy E1 carries X21 EOW (engineering order wire) data and thus the pointer s value reference a mib X21 port entry. Zero indicates not used |
| INT rsTTPF1SrcPointer | 1.3.6.1.4.1.1038.110.20.2.1.10 | INTEGER | read-only | A reference to the object which sends the data flow to F1 RSOH byte.Zero indicates not used |
| INT rsTTPSesThreshold | 1.3.6.1.4.1.1038.110.20.2.1.11 | INTEGER | read-only | The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
| INT rsTTPEOWByteLine | 1.3.6.1.4.1.1038.110.20.2.1.12 | INTEGER | read-write | The line determines the SOH byte selected for Engineering Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and finish with 5 lines of MSOH (5,6,7,8,9) E1 is on line 2 column 4. Zero indicates EOW not used, value different from 2 means EOW not on E1 |
| INT rsTTPEOWByteColumn | 1.3.6.1.4.1.1038.110.20.2.1.13 | INTEGER | read-write | The column determines the SOH byte selected for Engineering Order Wire: SOH is composed of Col [1,9] E1 is on line 2 column 4. Zero indicates EOW not used, value different from 4 means EOW not on E1 |
| SEV rsTTPLof | 1.3.6.1.4.1.1038.110.20.2.1.20 | Severity | read-write | Severity associed with Loss Of Frame failure for regenerator section terminaison. |
| rsCTP | 1.3.6.1.4.1.1038.110.25 | |||
| msTTP | 1.3.6.1.4.1.1038.110.30 | |||
| msTTPTable | 1.3.6.1.4.1.1038.110.30.2 | not-accessible | List of multiplex section terminaison in equipment. | |
| msTTPEntry | 1.3.6.1.4.1.1038.110.30.2.1 | not-accessible | A particular multiplex section terminaison of the equipment. | |
| INT msTTPIndex | 1.3.6.1.4.1.1038.110.30.2.1.1 | INTEGER | read-only | A unique value which identify a particular synchronous physical interface. The value of this index is always the same as spiTTPIndex |
| PRO msTTPProtectionType | 1.3.6.1.4.1.1038.110.30.2.1.2 | ProtectionType | read-write | The value of this field indicates the kind of wanted multiplex section protection. The default value is NONE. if value is changed in msp(1) or msSPRing(2) then (if it's possible) an entry is created respectivelly in mspTable or msSPRingTable. But these tables have to be completed to obtain a configured protection. If value is changed in None(0)then the associated entry in mspTable or msSPRingTable is deleted (if it's possible). |
| SAG msTTPMonitor | 1.3.6.1.4.1.1038.110.30.2.1.3 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this multiplex section terminaison. |
| STR msTTPName | 1.3.6.1.4.1.1038.110.30.2.1.4 | DisplayString | read-write | A text string which identifies the particular entry among the multiplex section terminaison entries. |
| MST msTTPFailure | 1.3.6.1.4.1.1038.110.30.2.1.5 | MsTTPFailure | read-only | Active failures on multiplex section terminaison |
| SEV msTTPSeverity | 1.3.6.1.4.1.1038.110.30.2.1.6 | Severity | read-only | Severity associed with active failures on multiplex section terminaison. |
| EOW msTTPEOWMode | 1.3.6.1.4.1.1038.110.30.2.1.7 | EOWMode | read-only | Mode used for EOW: Codir or contradir Master |
| INT msTTPE2SrcPointer | 1.3.6.1.4.1.1038.110.30.2.1.8 | INTEGER | read-only | A reference to the object which sends the data flow to E2 MSOH byte. Usualy E2 carries X21 EOW (engineering order wire) data. The reference is an index in X21 table.Zero indicates not used |
| INT msTTPEOWByteLine | 1.3.6.1.4.1.1038.110.30.2.1.9 | INTEGER | read-write | The line determines the SOH byte selected for Engineering Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and finish with 5 lines of MSOH (5,6,7,8,9) E2 is on line 9 column 7. Zero indicates not used, value different from 9 means EOW not on E2 |
| INT msTTPEOWByteColumn | 1.3.6.1.4.1.1038.110.30.2.1.10 | INTEGER | read-write | The column determines the SOH byte selected for Engineering Order Wire: SOH is composed of Col [1,9] E2 is on line 9 column 7. Zero indicates EOW not used, value different from 7 means EOW not on E2 |
| SAG msTTPMonEber | 1.3.6.1.4.1.1038.110.30.2.1.11 | SagemBoolean | read-write | If the value of this field is true, the eber is monitored and is used as MSP and SETS criterium. If this defect is detected, an ais signal is send downstream and rdi upstream. |
| INT msTTPSdThreshold | 1.3.6.1.4.1.1038.110.30.2.1.12 | INTEGER | read-write | A Signal Degrade failure is declared if the error block rate is greater than 1E(-mstSdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - mstSdThreshold). |
| INT msTTPSesThreshold | 1.3.6.1.4.1.1038.110.30.2.1.13 | INTEGER | read-only | The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
| SEV msTTPEber | 1.3.6.1.4.1.1038.110.30.2.1.20 | Severity | read-write | Severity associed with Excecive Bit Error Rate failure for multiplex section terminaison. |
| SEV msTTPSd | 1.3.6.1.4.1.1038.110.30.2.1.21 | Severity | read-write | Severity associed with Signal Degrade failure for multiplex section terminaison. |
| SEV msTTPRdi | 1.3.6.1.4.1.1038.110.30.2.1.22 | Severity | read-write | Severity associed with Remote Defect Indication failure for multiplex section terminaison. |
| msCTP | 1.3.6.1.4.1.1038.110.35 | |||
| msa | 1.3.6.1.4.1.1038.110.60 | |||
| msaTable | 1.3.6.1.4.1.1038.110.60.2 | not-accessible | List of multiplex section adaptation in equipment. | |
| msaEntry | 1.3.6.1.4.1.1038.110.60.2.1 | not-accessible | A particular multiplex section adaptation of the equipment. | |
| INT msaIndex | 1.3.6.1.4.1.1038.110.60.2.1.1 | INTEGER | read-only | Index of a particular entry among the multiplex section adaptation entries. |
| STM msaSTMLevel | 1.3.6.1.4.1.1038.110.60.2.1.2 | STMLevel | read-only | The STM-n level of the multiplex section adaptation. |
| MSA msaSinkType | 1.3.6.1.4.1.1038.110.60.2.1.3 | MsaSinkType | read-only | Type of msa sinkPointer: msa or mst |
| INT msaSinkPointer | 1.3.6.1.4.1.1038.110.60.2.1.4 | INTEGER | read-only | A reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and points to the MST it is hard wired with. |
| STR msaName | 1.3.6.1.4.1.1038.110.60.2.1.5 | DisplayString | read-write | A text string which identifies the particular entry among the multiplex section adaptation entries. |
| MSA msaSrc1Type | 1.3.6.1.4.1.1038.110.60.2.1.6 | MsaSrcType | read-only | Type of msa srcPointer: msa or vc4 |
| MSA msaSrc2Type | 1.3.6.1.4.1.1038.110.60.2.1.7 | MsaSrcType | read-only | Type of msa srcPointer: msa or vc4 |
| MSA msaSrc3Type | 1.3.6.1.4.1.1038.110.60.2.1.8 | MsaSrcType | read-only | Type of msa srcPointer: msa or vc4 |
| MSA msaSrc4Type | 1.3.6.1.4.1.1038.110.60.2.1.9 | MsaSrcType | read-only | Type of msa srcPointer: msa or vc4 |
| INT msaSrc1Pointer | 1.3.6.1.4.1.1038.110.60.2.1.10 | INTEGER | read-only | Table index of the object which sends the data flow to this function on equipment side. For STM16: 4 pseudo STM4 (group of 4STM1) identified by their index in msaTable. Theses indexes must be differents to thoses used by the MST Table. For STM4: 4 VC4 identified by their index in vc4Table For STM1: 1 VC4 identified by its index in vc4Table |
| INT msaSrc2Pointer | 1.3.6.1.4.1.1038.110.60.2.1.11 | INTEGER | read-only | A reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with. |
| INT msaSrc3Pointer | 1.3.6.1.4.1.1038.110.60.2.1.12 | INTEGER | read-only | A reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with. |
| INT msaSrc4Pointer | 1.3.6.1.4.1.1038.110.60.2.1.13 | INTEGER | read-only | A reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with. |
| au4CTP | 1.3.6.1.4.1.1038.110.70 | |||
| INT au4CTPNumber | 1.3.6.1.4.1.1038.110.70.1 | INTEGER | read-only | Number of administrative unit order 4 in equipment. |
| au4CTPTable | 1.3.6.1.4.1.1038.110.70.2 | not-accessible | List of administrative unit order 4 in equipment which are availables for new connection or used in connection. In that case, an indication on the connection type is set into the au4CTPCnxType Variable. All au4 CTP, which are made up of lower connection level (tu3 or tu12), are set to 'used' value with 'tu' type connection indication . | |
| au4CTPEntry | 1.3.6.1.4.1.1038.110.70.2.1 | not-accessible | A particular administrative unit order 4 of the equipment. | |
| INT au4CTPIndex | 1.3.6.1.4.1.1038.110.70.2.1.1 | INTEGER | read-only | A unique value which identify a particular administrative unit order 4. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| CTP au4CTPStatus | 1.3.6.1.4.1.1038.110.70.2.1.2 | CTPStatus | read-only | au4 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP |
| AU4 au4CTPCnxType | 1.3.6.1.4.1.1038.110.70.2.1.3 | Au4CTPCnxType | read-only | au4 connection Type: none, au4, au4-4c,au4-16c,tu. The 'none' value is used when there is no connection with this output CTP |
| STR au4CTPName | 1.3.6.1.4.1.1038.110.70.2.1.4 | DisplayString | read-write | A text string which identifies the particular entry among the administrative unit order 4 entries. |
| SAG au4CTPMonitor | 1.3.6.1.4.1.1038.110.70.2.1.6 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this administrative unit order 4. |
| AU4 au4CTPFailure | 1.3.6.1.4.1.1038.110.70.2.1.7 | Au4CTPFailure | read-only | Active failures on administrative unit order 4 |
| SEV au4CTPSeverity | 1.3.6.1.4.1.1038.110.70.2.1.8 | Severity | read-only | A reference to failure severity for administrative unit order 4. |
| SEV au4CTPAis | 1.3.6.1.4.1.1038.110.70.2.1.20 | Severity | read-write | Severity associed with Alarme Indication Signal failure for administrative unit order 4. |
| SEV au4CTPLop | 1.3.6.1.4.1.1038.110.70.2.1.21 | Severity | read-write | Severity associed with Loss Of Pointer failure for administrative unit order 4. |
| SEV au4CTPLom | 1.3.6.1.4.1.1038.110.70.2.1.22 | Severity | read-write | Severity associed with Loss Of MultiFrame failure for administrative unit order 4. |
| vc4TTP | 1.3.6.1.4.1.1038.110.100 | |||
| INT vc4TTPNumber | 1.3.6.1.4.1.1038.110.100.1 | INTEGER | read-only | Number of virtual container order 4 in equipment. |
| vc4TTPTable | 1.3.6.1.4.1.1038.110.100.2 | not-accessible | List of virtual container order 4 in equipment.The number of records depends on the kinds of configured boards | |
| vc4TTPEntry | 1.3.6.1.4.1.1038.110.100.2.1 | not-accessible | A particular virtual container order 4 of the equipment. | |
| INT vc4TTPIndex | 1.3.6.1.4.1.1038.110.100.2.1.1 | INTEGER | read-only | A unique value which identify a particular virtual container order 4. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| INT vc4TTPSinkPointer | 1.3.6.1.4.1.1038.110.100.2.1.2 | INTEGER | read-only | A reference to the object which sends the data flow to this function on synchronous or unsynchronous port interface side. This pointer corresponds to an index in the msTTPTable or nspiTTPTable. |
| VC4 vc4TTPSinkType | 1.3.6.1.4.1.1038.110.100.2.1.3 | Vc4TTPSinkType | read-only | A reference to the kind of the sink Pointer |
| STR vc4TTPName | 1.3.6.1.4.1.1038.110.100.2.1.5 | DisplayString | read-write | A text string which identifies the particular entry among the virtual container order 4 entries. |
| SAG vc4TTPMonitor | 1.3.6.1.4.1.1038.110.100.2.1.6 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this virtual container order 4. |
| VC4 vc4TTPFailure | 1.3.6.1.4.1.1038.110.100.2.1.7 | Vc4TTPFailure | read-only | Active failures on virtual container order 4 |
| SEV vc4TTPSeverity | 1.3.6.1.4.1.1038.110.100.2.1.8 | Severity | read-only | A reference to failure severity for virtual container order 4. |
| VC4 vc4TTPTraceMode | 1.3.6.1.4.1.1038.110.100.2.1.9 | Vc4TTPTraceMode | read-write | Configuration of the pathTrace length (1 byte or 16 bytes). |
| OCT vc4TTPPathTraceExpected | 1.3.6.1.4.1.1038.110.100.2.1.11 | OCTET STRING | read-write | The path trace is a user string that always follows the vc4. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace. |
| OCT vc4TTPPathTraceSent | 1.3.6.1.4.1.1038.110.100.2.1.12 | OCTET STRING | read-write | The path trace is a user string that always follows the vc4. The value of this field is sent in j1 byte as path trace for this vc4. The default value is `all 0'. |
| OCT vc4TTPPathTraceReceived | 1.3.6.1.4.1.1038.110.100.2.1.13 | OCTET STRING | read-only | The path trace is a user string that always follows the vc4. The value is the actual path trace received in j1 byte |
| VC4 vc4TTPLabelExpected | 1.3.6.1.4.1.1038.110.100.2.1.14 | Vc4TTPSignalLabel | read-only | The signal label indicates the multiplexing structure of the vc4. If the signal label received for this vc4 is not null and does not match this field, a Signal Label Mismatch failure is detected. If the received label is null a virtual container UNEQuiped failure is detected. |
| VC4 vc4TTPLabelSent | 1.3.6.1.4.1.1038.110.100.2.1.15 | Vc4TTPSignalLabel | read-write | The signal label indicates the multiplexing structure of the vc4. The value of this field in sent as signal label for the vc4. |
| VC4 vc4TTPLabelReceived | 1.3.6.1.4.1.1038.110.100.2.1.16 | Vc4TTPSignalLabel | read-only | The signal label indicates the multiplexing structure of the vc4. The value of this field is the actual received signal label for this vc4 |
| INT vc4TTPSdThreshold | 1.3.6.1.4.1.1038.110.100.2.1.17 | INTEGER | read-write | A Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold). |
| INT vc4TTPSesThreshold | 1.3.6.1.4.1.1038.110.100.2.1.18 | INTEGER | read-only | The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
| SAG vc4TTPBidirectionnal | 1.3.6.1.4.1.1038.110.100.2.1.19 | SagemBoolean | read-write | If set to false the equipment does not send Remote Defect Indication. |
| SEV vc4TTPRdi | 1.3.6.1.4.1.1038.110.100.2.1.20 | Severity | read-write | Severity associed with Remote Defect Indication failure for virtual container order 4. |
| SEV vc4TTPSd | 1.3.6.1.4.1.1038.110.100.2.1.21 | Severity | read-write | Severity associed with Signal Degrade failure for virtual container order 4. |
| SEV vc4TTPUneq | 1.3.6.1.4.1.1038.110.100.2.1.22 | Severity | read-write | Severity associed with virtual container UNEQuiped failure for virtual container order 4. |
| SEV vc4TTPPlm | 1.3.6.1.4.1.1038.110.100.2.1.23 | Severity | read-write | Severity associed with Path Label Mismatch failure for virtual container order 4. |
| SAG vc4TTPTimDis | 1.3.6.1.4.1.1038.110.100.2.1.24 | SagemBoolean | read-write | If set to true the equipment does not manage the Tim Failure. |
| SEV vc4TTPTim | 1.3.6.1.4.1.1038.110.100.2.1.25 | Severity | read-write | Severity associed with Trail Identifier Mismatch failure for virtual container order 4. |
| tu3CTP | 1.3.6.1.4.1.1038.110.120 | |||
| INT tu3CTPNumber | 1.3.6.1.4.1.1038.110.120.1 | INTEGER | read-only | Number of tributary unit in equipment. |
| tu3CTPTable | 1.3.6.1.4.1.1038.110.120.2 | not-accessible | List of tributary units order 3 in equipment which are availables for new connection or used in the same connection level. In that case, an indication on the connection point status is set into the tu3CTPStatus Variable. All tu3 CTP, which are involved in different connection level (tu12 or au4), disappear from this List. | |
| tu3CTPEntry | 1.3.6.1.4.1.1038.110.120.2.1 | not-accessible | A particular tributary unit of the equipment. | |
| INT tu3CTPIndex | 1.3.6.1.4.1.1038.110.120.2.1.1 | INTEGER | read-only | Index that identifies the particular entry among the tributary unit entries. |
| CTP tu3CTPStatus | 1.3.6.1.4.1.1038.110.120.2.1.2 | CTPStatus | read-only | tu3 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP |
| STR tu3CTPName | 1.3.6.1.4.1.1038.110.120.2.1.5 | DisplayString | read-write | A text string which identifies the particular entry among the tributary unit entries. |
| SAG tu3CTPMonitor | 1.3.6.1.4.1.1038.110.120.2.1.6 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this tributary unit. |
| TU3 tu3CTPFailure | 1.3.6.1.4.1.1038.110.120.2.1.7 | Tu3CTPFailure | read-only | Active failures on tributary unit |
| SEV tu3CTPSeverity | 1.3.6.1.4.1.1038.110.120.2.1.8 | Severity | read-only | A reference to failure severity for tributary unit. |
| SEV tu3CTPAis | 1.3.6.1.4.1.1038.110.120.2.1.20 | Severity | read-write | Severity associed with Alarme Indication Signal failure for tributary unit. |
| SEV tu3CTPLop | 1.3.6.1.4.1.1038.110.120.2.1.21 | Severity | read-write | Severity associed with Loss Of Pointer failure for tributary unit. |
| vc3TTP | 1.3.6.1.4.1.1038.110.130 | |||
| INT vc3TTPNumber | 1.3.6.1.4.1.1038.110.130.1 | INTEGER | read-only | Number of virtual container order 3 in equipment. |
| vc3TTPTable | 1.3.6.1.4.1.1038.110.130.2 | not-accessible | List of virtual container order 3 in equipment.The number of records depends on the kinds of configured boards | |
| vc3TTPEntry | 1.3.6.1.4.1.1038.110.130.2.1 | not-accessible | A particular virtual container order 3 of the equipment. | |
| INT vc3TTPIndex | 1.3.6.1.4.1.1038.110.130.2.1.1 | INTEGER | read-only | A unique value which identify a particular virtual container order 3. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| INT vc3TTPSinkPointer | 1.3.6.1.4.1.1038.110.130.2.1.2 | INTEGER | read-only | A reference to the object which sends the data flow to this function on non-sdh physical port side. |
| VC3 vc3TTPSinkType | 1.3.6.1.4.1.1038.110.130.2.1.3 | Vc3TTPSinkType | read-only | A reference to the kind of the sink Pointer |
| STR vc3TTPName | 1.3.6.1.4.1.1038.110.130.2.1.5 | DisplayString | read-write | A text string which identifies the particular entry among the virtual container order 3 entries. |
| SAG vc3TTPMonitor | 1.3.6.1.4.1.1038.110.130.2.1.6 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this virtual container order 3. |
| VCL vc3TTPFailure | 1.3.6.1.4.1.1038.110.130.2.1.7 | VcLoFailure | read-only | Active failures on virtual container order 3 |
| SEV vc3TTPSeverity | 1.3.6.1.4.1.1038.110.130.2.1.8 | Severity | read-only | A reference to failure severity for virtual container order 3. |
| OCT vc3TTPPathTraceExpected | 1.3.6.1.4.1.1038.110.130.2.1.9 | OCTET STRING | read-write | The path trace is a user string that always follows the vc3. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace. |
| OCT vc3TTPPathTraceSent | 1.3.6.1.4.1.1038.110.130.2.1.10 | OCTET STRING | read-write | The path trace is a user string that always follows the vc3. The value of this field is sent in j1 byte as path trace for this vc3. The default value is `all 0'. |
| OCT vc3TTPPathTraceReceived | 1.3.6.1.4.1.1038.110.130.2.1.11 | OCTET STRING | read-only | The path trace is a user string that always follows the vc3. The value is the actual path trace received in j1 byte |
| VC3 vc3TTPLabelExpected | 1.3.6.1.4.1.1038.110.130.2.1.12 | Vc3TTPSignalLabel | read-only | The signal label indicates the multiplexing structure of the vc3. Usualy the value of this field cannot be modified as most equipment use the asynchronous bit multiplexing. For historical reasons the receipt of label `unspecified ' does not produce a Signal Label Mismatch failure. |
| VC3 vc3TTPLabelSent | 1.3.6.1.4.1.1038.110.130.2.1.13 | Vc3TTPSignalLabel | read-write | The signal label indicates the multiplexing structure of the vc3. The value of this field is sent as signal label for the vc3. The unspecified value is used for compatibilty with old sdh equipments. The `unequiped' value actives low order unequiped generator (lug). In this case all 1 signal is inserted down and up stream. |
| VC3 vc3TTPLabelReceived | 1.3.6.1.4.1.1038.110.130.2.1.14 | Vc3TTPSignalLabel | read-only | The signal label indicates the multiplexing structure of the vc3. The value of this field is the actual received signal label for this vc3 |
| INT vc3TTPSdThreshold | 1.3.6.1.4.1.1038.110.130.2.1.15 | INTEGER | read-write | A Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold). |
| INT vc3TTPSesThreshold | 1.3.6.1.4.1.1038.110.130.2.1.16 | INTEGER | read-only | The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
| SAG vc3TTPBidirectionnal | 1.3.6.1.4.1.1038.110.130.2.1.17 | SagemBoolean | read-write | If set to false the equipment does not send Remote Defect Indication. |
| SEV vc3TTPRdi | 1.3.6.1.4.1.1038.110.130.2.1.20 | Severity | read-write | Severity associed with Remote Defect Indication failure for virtual container order 3. |
| SEV vc3TTPSd | 1.3.6.1.4.1.1038.110.130.2.1.21 | Severity | read-write | Severity associed with Signal Degrade failure for virtual container order 3. |
| SEV vc3TTPUneq | 1.3.6.1.4.1.1038.110.130.2.1.22 | Severity | read-write | Severity associed with virtual container UNEQuiped failure for virtual container order 3. |
| SEV vc3TTPPlm | 1.3.6.1.4.1.1038.110.130.2.1.23 | Severity | read-write | Severity associed with Path Label Mismatch failure for virtual container order 3. |
| SEV vc3TTPTim | 1.3.6.1.4.1.1038.110.130.2.1.24 | Severity | read-write | Severity associed with Trail Identifier Mismatch failure for virtual container order 3. |
| tu12CTP | 1.3.6.1.4.1.1038.110.140 | |||
| INT tu12CTPNumber | 1.3.6.1.4.1.1038.110.140.1 | INTEGER | read-only | Number of tributary unit in equipment. |
| tu12CTPTable | 1.3.6.1.4.1.1038.110.140.2 | not-accessible | List of tributary unit order 12 in equipment which are availables for new connection or used in the same connection level. In that case, an indication on the connection point Status is set into the tu12CTPStatus Variable. All tu12 CTP, which are involved in a different connection level (tu3 or au4), disappear from this List. | |
| tu12CTPEntry | 1.3.6.1.4.1.1038.110.140.2.1 | not-accessible | A particular tributary unit of the equipment. | |
| INT tu12CTPIndex | 1.3.6.1.4.1.1038.110.140.2.1.1 | INTEGER | read-only | A unique value which identify a particular tu12. |
| CTP tu12CTPStatus | 1.3.6.1.4.1.1038.110.140.2.1.2 | CTPStatus | read-only | tu12 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP |
| STR tu12CTPName | 1.3.6.1.4.1.1038.110.140.2.1.5 | DisplayString | read-write | A text string which identifies the particular entry among the tributary unit entries. |
| SAG tu12CTPMonitor | 1.3.6.1.4.1.1038.110.140.2.1.6 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this tributary unit. |
| TU1 tu12CTPFailure | 1.3.6.1.4.1.1038.110.140.2.1.7 | Tu12CTPFailure | read-only | Active failures on tributary unit |
| SEV tu12CTPSeverity | 1.3.6.1.4.1.1038.110.140.2.1.8 | Severity | read-only | A reference to failure severity for tributary unit. |
| SEV tu12CTPAis | 1.3.6.1.4.1.1038.110.140.2.1.20 | Severity | read-write | Severity associed with Alarme Indication Signal failure for tributary unit. |
| SEV tu12CTPLop | 1.3.6.1.4.1.1038.110.140.2.1.21 | Severity | read-write | Severity associed with Loss Of Pointer failure for tributary unit. |
| vc12TTP | 1.3.6.1.4.1.1038.110.150 | |||
| INT vc12TTPNumber | 1.3.6.1.4.1.1038.110.150.1 | INTEGER | read-only | Number of virtual container order 12 in equipment. |
| vc12TTPTable | 1.3.6.1.4.1.1038.110.150.2 | not-accessible | List of virtual container order 12 in equipment.The number of records depends on the kinds of configured boards | |
| vc12TTPEntry | 1.3.6.1.4.1.1038.110.150.2.1 | not-accessible | A particular virtual container order 12 of the equipment. | |
| INT vc12TTPIndex | 1.3.6.1.4.1.1038.110.150.2.1.1 | INTEGER | read-only | A unique value which identify a particular virtual container order 12. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| INT vc12TTPSinkPointer | 1.3.6.1.4.1.1038.110.150.2.1.2 | INTEGER | read-only | A reference to the object which sends the data flow to this function on non-sdh physical port side. |
| VC1 vc12TTPSinkType | 1.3.6.1.4.1.1038.110.150.2.1.3 | Vc12TTPSinkType | read-only | A reference to the kind of the sink Pointer |
| STR vc12TTPName | 1.3.6.1.4.1.1038.110.150.2.1.5 | DisplayString | read-write | A text string which identifies the particular entry among the virtual container order 12 entries. |
| SAG vc12TTPMonitor | 1.3.6.1.4.1.1038.110.150.2.1.6 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this virtual container order 12. |
| VCL vc12TTPFailure | 1.3.6.1.4.1.1038.110.150.2.1.7 | VcLoFailure | read-only | Active failures on virtual container order 12 |
| SEV vc12TTPSeverity | 1.3.6.1.4.1.1038.110.150.2.1.8 | Severity | read-only | A reference to failure severity for virtual container order 12. |
| OCT vc12TTPPathTraceExpected | 1.3.6.1.4.1.1038.110.150.2.1.9 | OCTET STRING | read-write | The path trace is a user string that always follows the vc12. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace. |
| OCT vc12TTPPathTraceSent | 1.3.6.1.4.1.1038.110.150.2.1.10 | OCTET STRING | read-write | The path trace is a user string that always follows the vc12. The value of this field is sent in j2 byte as path trace for this vc12. The default value is `all 0'. |
| OCT vc12TTPPathTraceReceived | 1.3.6.1.4.1.1038.110.150.2.1.11 | OCTET STRING | read-only | The path trace is a user string that always follows the vc12. The value is the actual path trace received in j2 byte |
| VC1 vc12TTPLabelExpected | 1.3.6.1.4.1.1038.110.150.2.1.12 | Vc12TTPSignalLabel | read-only | The signal label indicates the multiplexing structure of the vc12. Usualy the value of this field cannot be modified as most equipment use the asynchronous bit multiplexing. For historical reasons the receipt of label `unspecified ' does not produce a Signal Label Mismatch failure. |
| VC1 vc12TTPLabelSent | 1.3.6.1.4.1.1038.110.150.2.1.13 | Vc12TTPSignalLabel | read-write | The signal label indicates the multiplexing structure of the vc12. The value of this field is sent as signal label for the vc12. The unspecified value is used for compatibilty with old sdh equipments. The `unequiped' value actives low order unequiped generator (lug). In this case all 1 signal is inserted down and up stream. |
| VC1 vc12TTPLabelReceived | 1.3.6.1.4.1.1038.110.150.2.1.14 | Vc12TTPSignalLabel | read-only | The signal label indicates the multiplexing structure of the vc12. The value of this field is the actual received signal label for this vc12 |
| INT vc12TTPSdThreshold | 1.3.6.1.4.1.1038.110.150.2.1.15 | INTEGER | read-write | A Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold). |
| INT vc12TTPSesThreshold | 1.3.6.1.4.1.1038.110.150.2.1.16 | INTEGER | read-only | The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
| SAG vc12TTPBidirectionnal | 1.3.6.1.4.1.1038.110.150.2.1.17 | SagemBoolean | read-write | If set to false the equipment does not send Remote Defect Indication. |
| SEV vc12TTPRdi | 1.3.6.1.4.1.1038.110.150.2.1.20 | Severity | read-write | Severity associed with Remote Defect Indication failure for virtual container order 12. |
| SEV vc12TTPSd | 1.3.6.1.4.1.1038.110.150.2.1.21 | Severity | read-write | Severity associed with Signal Degrade failure for virtual container order 12. |
| SEV vc12TTPUneq | 1.3.6.1.4.1.1038.110.150.2.1.22 | Severity | read-write | Severity associed with virtual container UNEQuiped failure for virtual container order 12. |
| SEV vc12TTPPlm | 1.3.6.1.4.1.1038.110.150.2.1.23 | Severity | read-write | Severity associed with Path Label Mismatch failure for virtual container order 12. |
| SEV vc12TTPTim | 1.3.6.1.4.1.1038.110.150.2.1.24 | Severity | read-write | Severity associed with Trail Identifier Mismatch failure for virtual container order 12. |
| nspiCTP | 1.3.6.1.4.1.1038.110.160 | |||
| INT nspiCTPNumber | 1.3.6.1.4.1.1038.110.160.1 | INTEGER | read-only | A unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| nspiCTPTable | 1.3.6.1.4.1.1038.110.160.2 | not-accessible | List of non-sdh physical port in equipment. | |
| nspiCTPEntry | 1.3.6.1.4.1.1038.110.160.2.1 | not-accessible | A particular non-sdh physical port of the equipment. | |
| INT nspiCTPIndex | 1.3.6.1.4.1.1038.110.160.2.1.1 | INTEGER | read-only | A unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| NSP nspiCTPTTPType | 1.3.6.1.4.1.1038.110.160.2.1.2 | NspiSrcType | read-only | The type of VC which is associated to the nspi interface. |
| CTP nspiCTPStatus | 1.3.6.1.4.1.1038.110.160.2.1.3 | CTPStatus | read-only | nspi connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP |
| STR nspiCTPName | 1.3.6.1.4.1.1038.110.160.2.1.4 | DisplayString | read-write | A text string which identifies the particular entry among the non-sdh physical port entries. |
| nspiTTP | 1.3.6.1.4.1.1038.110.170 | |||
| INT nspiTTPNumber | 1.3.6.1.4.1.1038.110.170.1 | INTEGER | read-only | A unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| nspiTTPTable | 1.3.6.1.4.1.1038.110.170.2 | not-accessible | List of non-sdh physical port in equipment. | |
| nspiTTPEntry | 1.3.6.1.4.1.1038.110.170.2.1 | not-accessible | A particular non-sdh physical port of the equipment. | |
| INT nspiTTPIndex | 1.3.6.1.4.1.1038.110.170.2.1.1 | INTEGER | read-only | A unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| NSP nspiTTPType | 1.3.6.1.4.1.1038.110.170.2.1.2 | NspiTTPType | read-only | The type of media for the nspi interface. |
| NSP nspiTTPLevel | 1.3.6.1.4.1.1038.110.170.2.1.3 | NspiTTPLevel | read-only | The rate level of the nspi interface. |
| STR nspiTTPName | 1.3.6.1.4.1.1038.110.170.2.1.4 | DisplayString | read-write | A text string which identifies the particular entry among the non-sdh physical port entries. |
| INT nspiTTPBoardIndex | 1.3.6.1.4.1.1038.110.170.2.1.5 | INTEGER | read-only | Index of the Board that supports the physical acces of this interface |
| INT nspiTTPBoardAcces | 1.3.6.1.4.1.1038.110.170.2.1.6 | INTEGER | read-only | Friendly Index of the physical acces on the Board that supports the interface |
| NSP nspiTTPSrcType | 1.3.6.1.4.1.1038.110.170.2.1.7 | NspiSrcType | read-only | A reference to the type of object which sends the data flow to this interface. Usually the value is vc12, vc3 or vc4 types. |
| INT nspiTTPSrcPointer | 1.3.6.1.4.1.1038.110.170.2.1.8 | INTEGER | read-only | A reference to the object which sends the data flow to this interface. Usually the value is the Index of a vc12, vc3 or vc4. |
| SAG nspiTTPMonitor | 1.3.6.1.4.1.1038.110.170.2.1.9 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this non-sdh physical port. |
| NSP nspiTTPFailure | 1.3.6.1.4.1.1038.110.170.2.1.10 | NspiTTPFailure | read-only | Active failures on non-sdh physical port |
| SEV nspiTTPSeverity | 1.3.6.1.4.1.1038.110.170.2.1.11 | Severity | read-only | A reference to failure severity for non-sdh physical port. |
| LOO nspiTTPLoopback | 1.3.6.1.4.1.1038.110.170.2.1.14 | Loopback | read-write | This field gives the active loopback status on the non-sdh physical port. When its value is `line' the data flow recieved from the port side is sent back to the line. When its value is `equipment' the data flow recieved form equipment side is send back. The field can be set to a particular loopback value, even if there no garantee that the loopback is really done. The real loopback status of the interface must be checked in the response. The loopback can be cleared by the equipment when it cannot remain for any reason. |
| SEV nspiTTPLos | 1.3.6.1.4.1.1038.110.170.2.1.20 | Severity | read-write | Severity associed with Loss Of Signal failure for non-sdh physical port. |
| SEV nspiTTPAis | 1.3.6.1.4.1.1038.110.170.2.1.21 | Severity | read-write | Severity associed with Alarme Indication Signal failure for non-sdh physical port. |
| channel | 1.3.6.1.4.1.1038.110.180 | |||
| INT channelNumber | 1.3.6.1.4.1.1038.110.180.1 | INTEGER | read-only | Number of SDH Channels in equipment. |
| channelTable | 1.3.6.1.4.1.1038.110.180.2 | not-accessible | List of SDH Channels in equipment. | |
| channelEntry | 1.3.6.1.4.1.1038.110.180.2.1 | not-accessible | A particular SDH Channel of the equipment. | |
| INT channelIndex | 1.3.6.1.4.1.1038.110.180.2.1.1 | INTEGER | read-only | A unique value which identify a particular SDH Channel. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
| CHA channelEncaps | 1.3.6.1.4.1.1038.110.180.2.1.2 | ChannelEncaps | read-write | The type of encapsulation used to map Data stream into Sdh containers |
| INT channelNbVc4 | 1.3.6.1.4.1.1038.110.180.2.1.5 | INTEGER | read-write | Number of VC4 into the channel. |
| INT channelNbVc3 | 1.3.6.1.4.1.1038.110.180.2.1.6 | INTEGER | read-write | Number of VC3 into the channel. |
| INT channelNbVc12 | 1.3.6.1.4.1.1038.110.180.2.1.7 | INTEGER | read-write | Number of VC12 into the channel. |
| CHA channelConcat | 1.3.6.1.4.1.1038.110.180.2.1.8 | ChannelConcat | read-write | The type of Concatenation used within the channel |
| INT channelAdminStatus | 1.3.6.1.4.1.1038.110.180.2.1.9 | INTEGER | read-write | The desired state of the channel. The testing(3) state indicates that no operational packets can be passed. |
| INT channelOperStatus | 1.3.6.1.4.1.1038.110.180.2.1.10 | INTEGER | read-only | The current operational state of the channel. The testing(3) state indicates that no operational packets can be passed. |
| INT channelFirstIndex | 1.3.6.1.4.1.1038.110.180.2.1.11 | INTEGER | read-write | Index of the first Vc in the Channel when it is configured. Otherwise this field is set to 0. |
| INT channelDelay | 1.3.6.1.4.1.1038.110.180.2.1.12 | INTEGER | read-write | This field give the maximum delay (in millisecondes) for receiving virtual concatenated frames. This field is set to 0 when channelConcat is different to virtual(1) |
| SAG channelMonitor | 1.3.6.1.4.1.1038.110.180.2.1.13 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection is stopped for this channel. |
| CHA channelFailure | 1.3.6.1.4.1.1038.110.180.2.1.14 | ChannelFailure | read-only | Active failures on channel |
| SEV channelSeverity | 1.3.6.1.4.1.1038.110.180.2.1.15 | Severity | read-only | A reference to failure severity for non-sdh physical port. |
| SEV channelLoa | 1.3.6.1.4.1.1038.110.180.2.1.16 | Severity | read-write | Severity associated with Loss Of Alignment failure for channel. |
| SEV channelLom | 1.3.6.1.4.1.1038.110.180.2.1.17 | Severity | read-write | Severity associated with Loss Of Multiframe failure for channel. |
| SEV channelSqm | 1.3.6.1.4.1.1038.110.180.2.1.18 | Severity | read-write | Severity associated with Sequence Mismatch failure for channel. |
| bandwidth | 1.3.6.1.4.1.1038.110.190 | |||
| INT bandwidthNumber | 1.3.6.1.4.1.1038.110.190.1 | INTEGER | read-only | Number of bandwidth units which are available in the equipement. The number of units depends on their type (Vc4, Vc3, Vc12), on the number of Data card and on the bandwidth size which has been configured for this card. For a Data card which is mapped on a STM16, there are 16 Vc4 entries (or 3*16 Vc3 entries or 63*16 Vc12 entries) in the BandwidthTable. |
| bandwidthTable | 1.3.6.1.4.1.1038.110.190.2 | not-accessible | List of Bandwidth units in equipment. It represent the bandwidth occupation of each non-sdh card | |
| bandwidthEntry | 1.3.6.1.4.1.1038.110.190.2.1 | not-accessible | A particular unit part of a non-sdh card bandwidth. | |
| INT bandwidthIndex | 1.3.6.1.4.1.1038.110.190.2.1.1 | INTEGER | read-only | A unique value which identify a particular unit of a non-sdh card bandwidth. The value of index is a Vc Index which change when bandwidthSrcType value is modified. |
| INT bandwidthBoardIndex | 1.3.6.1.4.1.1038.110.190.2.1.2 | INTEGER | read-only | Index of the Board that supports the bandwidth unit. |
| NSP bandwidthSrcType | 1.3.6.1.4.1.1038.110.190.2.1.3 | NspiSrcType | read-write | Define the decomposition level of the bandwidth. |
| INT bandwidthSrcPointer | 1.3.6.1.4.1.1038.110.190.2.1.4 | INTEGER | read-only | this field is set to bandwidthIndex when the unit is used by a channel and set to 0 otherwise. It defines the TTP and CTP index associated to the channel. |
| NSP bandwidthSinkType | 1.3.6.1.4.1.1038.110.190.2.1.5 | NspiSrcType | read-write | A reference to the kind of the sink Pointer. Usually the value is Channel. |
| INT bandwidthSinkPointer | 1.3.6.1.4.1.1038.110.190.2.1.6 | INTEGER | read-write | A reference to the object which sends the data flow to this function on unsynchronous port interface side. This pointer corresponds to an index in the channelTable. |
| INT bandwidthAdminStatus | 1.3.6.1.4.1.1038.110.190.2.1.7 | INTEGER | read-write | The desired state of the Vc. The testing(3) state indicates that no operational packets can be passed. |
| INT bandwidthOperStatus | 1.3.6.1.4.1.1038.110.190.2.1.8 | INTEGER | read-only | The current operational state of the Vc. The testing(3) state indicates that no operational packets can be passed. |
| INT bandwidthPrevIndex | 1.3.6.1.4.1.1038.110.190.2.1.9 | INTEGER | read-only | A reference to the previous VC into the channel. This field is set to 0 if the VC is not associated to a channel or if it is the first Vc of the channel. |
| INT bandwidthNextIndex | 1.3.6.1.4.1.1038.110.190.2.1.10 | INTEGER | read-only | A reference to the next VC into the channel. This field is set to 0 if the VC is not associated to a channel or if it is the last Vc of the channel. |
RFC description
Defines SDH transmission path management following ETSI ETS 300 304 standard structure.
Start monitoring SAGEM-Tolbiac SDH transmission network-element equipment (termination-point alarm severity/loopback) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.