SDH-ETS-MIB

MIB Reference — IPNetwork Monitor

All MIBsSDH-ETS-MIB

Organization: SAGEM-Tolbiac drd/ddp/tmhd

Last Updated: 2002-05-22

Category: Microwave Radio - SAGEM

Description:

Manages SAGEM SDH synchronous transport equipment configuration and performance monitoring.

Imported Objects

From EQUIPMENT-MIB

SagemBoolean
Severity

From SAGEM-DR-MIB

sagemDrMODULE-IDENTITY

From SNMPv2-SMI

MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

DisplayString

What Is SDH-ETS-MIB?

SDH-ETS-MIB is a SAGEM-Tolbiac (drd/ddp/tmhd division) proprietary MIB (per ETSI ETS 300 304, built on EQUIPMENT-MIB/SAGEM-DR-MIB, referenced by XCON-MIB for cross-connections) defining the SDH transmission portion of network-element equipment. Its SPI (SDH Physical Interface) TTP (Trail Termination Point) table, keyed by index, records STM level, type, name, board index/access, monitor/failure/severity settings, loopback, LOS (Loss of Signal), and TF (Transmission Failure), while a companion RS (Regenerator Section) TTP table records monitor/name/failure/severity, EOW mode, and E1/F1 source pointers. As a status/configuration MIB it lets an administrator confirm SDH termination-point alarm severity and loopback state on a SAGEM SDH network element. It is deployed on SAGEM-Tolbiac SDH transmission network-element equipment. Engineers can download the SDH-ETS-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in SDH-ETS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • SDH termination-point alarm severity and loopback state

Supported Devices

  • SAGEM-Tolbiac SDH transmission network-element equipment

Monitoring Examples

An administrator checks spiTTPFailure and spiTTPLos to diagnose a signal-loss condition on a SAGEM SDH network element's termination point.

OIDs
OID symbolicOID numericTypeAccessDescription
sdhEts1.3.6.1.4.1.1038.110The MIB module defines SDH transmition part of an equipment This MIB use the logical model defined in ETSI ETS 300 304. ETS 300 304 (February 1997) defines the SDH information model for the Network Element. This MIB refers to SHELF-MIB for the definition of the Board that supports the interface. This MIB is refered by XCON-MIB that uses the definition of termination point to create cross connection. This MIB also define configuration of the different SDH blocs such as alarm monitoring and severity and give the current status of the termination point.
spiTTP1.3.6.1.4.1.1038.110.10
INT spiTTPNumber1.3.6.1.4.1.1038.110.10.1INTEGERread-onlyNumber of synchronous physical interface in equipment = number of element in spiTTPTable
spiTTPTable1.3.6.1.4.1.1038.110.10.2not-accessibleList of synchronous physical interface in equipment.
spiTTPEntry1.3.6.1.4.1.1038.110.10.2.1not-accessibleA particular synchronous physical interface of the equipment.
INT spiTTPIndex1.3.6.1.4.1.1038.110.10.2.1.1INTEGERread-onlyA unique value which identify a particular synchronous physical interface. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware. Exemple: For ADR155c equipement index are 1,64,127,190 for STM1 interfaces. For ADR2500c equipement index are: 1,1009,2017,3025,4033,5041,6049,7057 for 8 STM16 or 8 STM4, 1,253,505,757 1009,1261,1513,1765 | 2017,2269,2521,2773 3025,3277,3529,3781 | --> for 8 (4*STM1) 4033,4285,4537,4789 5041,5293,5545,5797 | 6049,6301,6553,6805 7057,7309,7561,7813 |
STM spiTTPStmLevel1.3.6.1.4.1.1038.110.10.2.1.2STMLevelread-onlyThe STM-n level of the interface.
SPI spiTTPType1.3.6.1.4.1.1038.110.10.2.1.3SpiTTPTyperead-onlyThe kind of the interface: electrical or optical
STR spiTTPName1.3.6.1.4.1.1038.110.10.2.1.4DisplayStringread-writeA text string which identifies the particular entry among the synchronous physical interface entries.
INT spiTTPBoardIndex1.3.6.1.4.1.1038.110.10.2.1.5INTEGERread-onlyIndex of the Board that supports the physical acces of this interface. This index refers to another MIB that defines the board
INT spiTTPBoardAcces1.3.6.1.4.1.1038.110.10.2.1.6INTEGERread-onlyFriendly Index of the physical acces on the Board that supports the interface
SAG spiTTPMonitor1.3.6.1.4.1.1038.110.10.2.1.7SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this synchronous physical interface.
SPI spiTTPFailure1.3.6.1.4.1.1038.110.10.2.1.8SpiTTPFailureread-onlyActive failures on synchronous physical interface
SEV spiTTPSeverity1.3.6.1.4.1.1038.110.10.2.1.9Severityread-onlySeverity associed with active failure for synchronous physical interface.
LOO spiTTPLoopback1.3.6.1.4.1.1038.110.10.2.1.10Loopbackread-writeThis field gives the active loopback status on the synchronous physical interface. When its value is `line' the data flow recieved from the port side is sent back to the line. When its value is `equipment' the data flow recieved form equipment side is send back. The field can be set to a particular loopback value, even if there no garantee that the loopback is really done. The real loopback status of the interface must be checked in the response. The loopback can be cleared by the equipment when it cannot remain for any reason.
SEV spiTTPLos1.3.6.1.4.1.1038.110.10.2.1.20Severityread-writeSeverity associed with Loss Of Signal failure for synchronous physical interface.
SEV spiTTPTf1.3.6.1.4.1.1038.110.10.2.1.21Severityread-writeSeverity associed with Tranmit Fail failure for synchronous physical interface.
rsTTP1.3.6.1.4.1.1038.110.20
rsTTPTable1.3.6.1.4.1.1038.110.20.2not-accessibleList of regenerator section terminaison in equipment.
rsTTPEntry1.3.6.1.4.1.1038.110.20.2.1not-accessibleA particular regenerator section terminaison of the equipment.
INT rsTTPIndex1.3.6.1.4.1.1038.110.20.2.1.1INTEGERread-onlyA unique value which identify a particular synchronous physical interface. The value of this index is always the same as spiTTPIndex.
SAG rsTTPMonitor1.3.6.1.4.1.1038.110.20.2.1.2SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this regenerator section terminaison.
STR rsTTPName1.3.6.1.4.1.1038.110.20.2.1.3DisplayStringread-writeA text string which identifies the particular entry among the regenerator section terminaison entries.
RST rsTTPFailure1.3.6.1.4.1.1038.110.20.2.1.4RsTTPFailureread-onlyActive failures on regenerator section terminaison
SEV rsTTPSeverity1.3.6.1.4.1.1038.110.20.2.1.5Severityread-onlySeverity associed active Failure for regenerator section terminaison.
EOW rsTTPEOWMode1.3.6.1.4.1.1038.110.20.2.1.8EOWModeread-onlyMode used for EOW: Codir or contradir Master
INT rsTTPE1SrcPointer1.3.6.1.4.1.1038.110.20.2.1.9INTEGERread-onlyA reference to the object which sends the data flow to E1 RSOH byte (index in X21 table) Usualy E1 carries X21 EOW (engineering order wire) data and thus the pointer s value reference a mib X21 port entry. Zero indicates not used
INT rsTTPF1SrcPointer1.3.6.1.4.1.1038.110.20.2.1.10INTEGERread-onlyA reference to the object which sends the data flow to F1 RSOH byte.Zero indicates not used
INT rsTTPSesThreshold1.3.6.1.4.1.1038.110.20.2.1.11INTEGERread-onlyThe number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function
INT rsTTPEOWByteLine1.3.6.1.4.1.1038.110.20.2.1.12INTEGERread-writeThe line determines the SOH byte selected for Engineering Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and finish with 5 lines of MSOH (5,6,7,8,9) E1 is on line 2 column 4. Zero indicates EOW not used, value different from 2 means EOW not on E1
INT rsTTPEOWByteColumn1.3.6.1.4.1.1038.110.20.2.1.13INTEGERread-writeThe column determines the SOH byte selected for Engineering Order Wire: SOH is composed of Col [1,9] E1 is on line 2 column 4. Zero indicates EOW not used, value different from 4 means EOW not on E1
SEV rsTTPLof1.3.6.1.4.1.1038.110.20.2.1.20Severityread-writeSeverity associed with Loss Of Frame failure for regenerator section terminaison.
rsCTP1.3.6.1.4.1.1038.110.25
msTTP1.3.6.1.4.1.1038.110.30
msTTPTable1.3.6.1.4.1.1038.110.30.2not-accessibleList of multiplex section terminaison in equipment.
msTTPEntry1.3.6.1.4.1.1038.110.30.2.1not-accessibleA particular multiplex section terminaison of the equipment.
INT msTTPIndex1.3.6.1.4.1.1038.110.30.2.1.1INTEGERread-onlyA unique value which identify a particular synchronous physical interface. The value of this index is always the same as spiTTPIndex
PRO msTTPProtectionType1.3.6.1.4.1.1038.110.30.2.1.2ProtectionTyperead-writeThe value of this field indicates the kind of wanted multiplex section protection. The default value is NONE. if value is changed in msp(1) or msSPRing(2) then (if it's possible) an entry is created respectivelly in mspTable or msSPRingTable. But these tables have to be completed to obtain a configured protection. If value is changed in None(0)then the associated entry in mspTable or msSPRingTable is deleted (if it's possible).
SAG msTTPMonitor1.3.6.1.4.1.1038.110.30.2.1.3SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this multiplex section terminaison.
STR msTTPName1.3.6.1.4.1.1038.110.30.2.1.4DisplayStringread-writeA text string which identifies the particular entry among the multiplex section terminaison entries.
MST msTTPFailure1.3.6.1.4.1.1038.110.30.2.1.5MsTTPFailureread-onlyActive failures on multiplex section terminaison
SEV msTTPSeverity1.3.6.1.4.1.1038.110.30.2.1.6Severityread-onlySeverity associed with active failures on multiplex section terminaison.
EOW msTTPEOWMode1.3.6.1.4.1.1038.110.30.2.1.7EOWModeread-onlyMode used for EOW: Codir or contradir Master
INT msTTPE2SrcPointer1.3.6.1.4.1.1038.110.30.2.1.8INTEGERread-onlyA reference to the object which sends the data flow to E2 MSOH byte. Usualy E2 carries X21 EOW (engineering order wire) data. The reference is an index in X21 table.Zero indicates not used
INT msTTPEOWByteLine1.3.6.1.4.1.1038.110.30.2.1.9INTEGERread-writeThe line determines the SOH byte selected for Engineering Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and finish with 5 lines of MSOH (5,6,7,8,9) E2 is on line 9 column 7. Zero indicates not used, value different from 9 means EOW not on E2
INT msTTPEOWByteColumn1.3.6.1.4.1.1038.110.30.2.1.10INTEGERread-writeThe column determines the SOH byte selected for Engineering Order Wire: SOH is composed of Col [1,9] E2 is on line 9 column 7. Zero indicates EOW not used, value different from 7 means EOW not on E2
SAG msTTPMonEber1.3.6.1.4.1.1038.110.30.2.1.11SagemBooleanread-writeIf the value of this field is true, the eber is monitored and is used as MSP and SETS criterium. If this defect is detected, an ais signal is send downstream and rdi upstream.
INT msTTPSdThreshold1.3.6.1.4.1.1038.110.30.2.1.12INTEGERread-writeA Signal Degrade failure is declared if the error block rate is greater than 1E(-mstSdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - mstSdThreshold).
INT msTTPSesThreshold1.3.6.1.4.1.1038.110.30.2.1.13INTEGERread-onlyThe number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function
SEV msTTPEber1.3.6.1.4.1.1038.110.30.2.1.20Severityread-writeSeverity associed with Excecive Bit Error Rate failure for multiplex section terminaison.
SEV msTTPSd1.3.6.1.4.1.1038.110.30.2.1.21Severityread-writeSeverity associed with Signal Degrade failure for multiplex section terminaison.
SEV msTTPRdi1.3.6.1.4.1.1038.110.30.2.1.22Severityread-writeSeverity associed with Remote Defect Indication failure for multiplex section terminaison.
msCTP1.3.6.1.4.1.1038.110.35
msa1.3.6.1.4.1.1038.110.60
msaTable1.3.6.1.4.1.1038.110.60.2not-accessibleList of multiplex section adaptation in equipment.
msaEntry1.3.6.1.4.1.1038.110.60.2.1not-accessibleA particular multiplex section adaptation of the equipment.
INT msaIndex1.3.6.1.4.1.1038.110.60.2.1.1INTEGERread-onlyIndex of a particular entry among the multiplex section adaptation entries.
STM msaSTMLevel1.3.6.1.4.1.1038.110.60.2.1.2STMLevelread-onlyThe STM-n level of the multiplex section adaptation.
MSA msaSinkType1.3.6.1.4.1.1038.110.60.2.1.3MsaSinkTyperead-onlyType of msa sinkPointer: msa or mst
INT msaSinkPointer1.3.6.1.4.1.1038.110.60.2.1.4INTEGERread-onlyA reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and points to the MST it is hard wired with.
STR msaName1.3.6.1.4.1.1038.110.60.2.1.5DisplayStringread-writeA text string which identifies the particular entry among the multiplex section adaptation entries.
MSA msaSrc1Type1.3.6.1.4.1.1038.110.60.2.1.6MsaSrcTyperead-onlyType of msa srcPointer: msa or vc4
MSA msaSrc2Type1.3.6.1.4.1.1038.110.60.2.1.7MsaSrcTyperead-onlyType of msa srcPointer: msa or vc4
MSA msaSrc3Type1.3.6.1.4.1.1038.110.60.2.1.8MsaSrcTyperead-onlyType of msa srcPointer: msa or vc4
MSA msaSrc4Type1.3.6.1.4.1.1038.110.60.2.1.9MsaSrcTyperead-onlyType of msa srcPointer: msa or vc4
INT msaSrc1Pointer1.3.6.1.4.1.1038.110.60.2.1.10INTEGERread-onlyTable index of the object which sends the data flow to this function on equipment side. For STM16: 4 pseudo STM4 (group of 4STM1) identified by their index in msaTable. Theses indexes must be differents to thoses used by the MST Table. For STM4: 4 VC4 identified by their index in vc4Table For STM1: 1 VC4 identified by its index in vc4Table
INT msaSrc2Pointer1.3.6.1.4.1.1038.110.60.2.1.11INTEGERread-onlyA reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with.
INT msaSrc3Pointer1.3.6.1.4.1.1038.110.60.2.1.12INTEGERread-onlyA reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with.
INT msaSrc4Pointer1.3.6.1.4.1.1038.110.60.2.1.13INTEGERread-onlyA reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with.
au4CTP1.3.6.1.4.1.1038.110.70
INT au4CTPNumber1.3.6.1.4.1.1038.110.70.1INTEGERread-onlyNumber of administrative unit order 4 in equipment.
au4CTPTable1.3.6.1.4.1.1038.110.70.2not-accessibleList of administrative unit order 4 in equipment which are availables for new connection or used in connection. In that case, an indication on the connection type is set into the au4CTPCnxType Variable. All au4 CTP, which are made up of lower connection level (tu3 or tu12), are set to 'used' value with 'tu' type connection indication .
au4CTPEntry1.3.6.1.4.1.1038.110.70.2.1not-accessibleA particular administrative unit order 4 of the equipment.
INT au4CTPIndex1.3.6.1.4.1.1038.110.70.2.1.1INTEGERread-onlyA unique value which identify a particular administrative unit order 4. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
CTP au4CTPStatus1.3.6.1.4.1.1038.110.70.2.1.2CTPStatusread-onlyau4 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP
AU4 au4CTPCnxType1.3.6.1.4.1.1038.110.70.2.1.3Au4CTPCnxTyperead-onlyau4 connection Type: none, au4, au4-4c,au4-16c,tu. The 'none' value is used when there is no connection with this output CTP
STR au4CTPName1.3.6.1.4.1.1038.110.70.2.1.4DisplayStringread-writeA text string which identifies the particular entry among the administrative unit order 4 entries.
SAG au4CTPMonitor1.3.6.1.4.1.1038.110.70.2.1.6SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this administrative unit order 4.
AU4 au4CTPFailure1.3.6.1.4.1.1038.110.70.2.1.7Au4CTPFailureread-onlyActive failures on administrative unit order 4
SEV au4CTPSeverity1.3.6.1.4.1.1038.110.70.2.1.8Severityread-onlyA reference to failure severity for administrative unit order 4.
SEV au4CTPAis1.3.6.1.4.1.1038.110.70.2.1.20Severityread-writeSeverity associed with Alarme Indication Signal failure for administrative unit order 4.
SEV au4CTPLop1.3.6.1.4.1.1038.110.70.2.1.21Severityread-writeSeverity associed with Loss Of Pointer failure for administrative unit order 4.
SEV au4CTPLom1.3.6.1.4.1.1038.110.70.2.1.22Severityread-writeSeverity associed with Loss Of MultiFrame failure for administrative unit order 4.
vc4TTP1.3.6.1.4.1.1038.110.100
INT vc4TTPNumber1.3.6.1.4.1.1038.110.100.1INTEGERread-onlyNumber of virtual container order 4 in equipment.
vc4TTPTable1.3.6.1.4.1.1038.110.100.2not-accessibleList of virtual container order 4 in equipment.The number of records depends on the kinds of configured boards
vc4TTPEntry1.3.6.1.4.1.1038.110.100.2.1not-accessibleA particular virtual container order 4 of the equipment.
INT vc4TTPIndex1.3.6.1.4.1.1038.110.100.2.1.1INTEGERread-onlyA unique value which identify a particular virtual container order 4. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
INT vc4TTPSinkPointer1.3.6.1.4.1.1038.110.100.2.1.2INTEGERread-onlyA reference to the object which sends the data flow to this function on synchronous or unsynchronous port interface side. This pointer corresponds to an index in the msTTPTable or nspiTTPTable.
VC4 vc4TTPSinkType1.3.6.1.4.1.1038.110.100.2.1.3Vc4TTPSinkTyperead-onlyA reference to the kind of the sink Pointer
STR vc4TTPName1.3.6.1.4.1.1038.110.100.2.1.5DisplayStringread-writeA text string which identifies the particular entry among the virtual container order 4 entries.
SAG vc4TTPMonitor1.3.6.1.4.1.1038.110.100.2.1.6SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this virtual container order 4.
VC4 vc4TTPFailure1.3.6.1.4.1.1038.110.100.2.1.7Vc4TTPFailureread-onlyActive failures on virtual container order 4
SEV vc4TTPSeverity1.3.6.1.4.1.1038.110.100.2.1.8Severityread-onlyA reference to failure severity for virtual container order 4.
VC4 vc4TTPTraceMode1.3.6.1.4.1.1038.110.100.2.1.9Vc4TTPTraceModeread-writeConfiguration of the pathTrace length (1 byte or 16 bytes).
OCT vc4TTPPathTraceExpected1.3.6.1.4.1.1038.110.100.2.1.11OCTET STRINGread-writeThe path trace is a user string that always follows the vc4. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace.
OCT vc4TTPPathTraceSent1.3.6.1.4.1.1038.110.100.2.1.12OCTET STRINGread-writeThe path trace is a user string that always follows the vc4. The value of this field is sent in j1 byte as path trace for this vc4. The default value is `all 0'.
OCT vc4TTPPathTraceReceived1.3.6.1.4.1.1038.110.100.2.1.13OCTET STRINGread-onlyThe path trace is a user string that always follows the vc4. The value is the actual path trace received in j1 byte
VC4 vc4TTPLabelExpected1.3.6.1.4.1.1038.110.100.2.1.14Vc4TTPSignalLabelread-onlyThe signal label indicates the multiplexing structure of the vc4. If the signal label received for this vc4 is not null and does not match this field, a Signal Label Mismatch failure is detected. If the received label is null a virtual container UNEQuiped failure is detected.
VC4 vc4TTPLabelSent1.3.6.1.4.1.1038.110.100.2.1.15Vc4TTPSignalLabelread-writeThe signal label indicates the multiplexing structure of the vc4. The value of this field in sent as signal label for the vc4.
VC4 vc4TTPLabelReceived1.3.6.1.4.1.1038.110.100.2.1.16Vc4TTPSignalLabelread-onlyThe signal label indicates the multiplexing structure of the vc4. The value of this field is the actual received signal label for this vc4
INT vc4TTPSdThreshold1.3.6.1.4.1.1038.110.100.2.1.17INTEGERread-writeA Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold).
INT vc4TTPSesThreshold1.3.6.1.4.1.1038.110.100.2.1.18INTEGERread-onlyThe number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function
SAG vc4TTPBidirectionnal1.3.6.1.4.1.1038.110.100.2.1.19SagemBooleanread-writeIf set to false the equipment does not send Remote Defect Indication.
SEV vc4TTPRdi1.3.6.1.4.1.1038.110.100.2.1.20Severityread-writeSeverity associed with Remote Defect Indication failure for virtual container order 4.
SEV vc4TTPSd1.3.6.1.4.1.1038.110.100.2.1.21Severityread-writeSeverity associed with Signal Degrade failure for virtual container order 4.
SEV vc4TTPUneq1.3.6.1.4.1.1038.110.100.2.1.22Severityread-writeSeverity associed with virtual container UNEQuiped failure for virtual container order 4.
SEV vc4TTPPlm1.3.6.1.4.1.1038.110.100.2.1.23Severityread-writeSeverity associed with Path Label Mismatch failure for virtual container order 4.
SAG vc4TTPTimDis1.3.6.1.4.1.1038.110.100.2.1.24SagemBooleanread-writeIf set to true the equipment does not manage the Tim Failure.
SEV vc4TTPTim1.3.6.1.4.1.1038.110.100.2.1.25Severityread-writeSeverity associed with Trail Identifier Mismatch failure for virtual container order 4.
tu3CTP1.3.6.1.4.1.1038.110.120
INT tu3CTPNumber1.3.6.1.4.1.1038.110.120.1INTEGERread-onlyNumber of tributary unit in equipment.
tu3CTPTable1.3.6.1.4.1.1038.110.120.2not-accessibleList of tributary units order 3 in equipment which are availables for new connection or used in the same connection level. In that case, an indication on the connection point status is set into the tu3CTPStatus Variable. All tu3 CTP, which are involved in different connection level (tu12 or au4), disappear from this List.
tu3CTPEntry1.3.6.1.4.1.1038.110.120.2.1not-accessibleA particular tributary unit of the equipment.
INT tu3CTPIndex1.3.6.1.4.1.1038.110.120.2.1.1INTEGERread-onlyIndex that identifies the particular entry among the tributary unit entries.
CTP tu3CTPStatus1.3.6.1.4.1.1038.110.120.2.1.2CTPStatusread-onlytu3 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP
STR tu3CTPName1.3.6.1.4.1.1038.110.120.2.1.5DisplayStringread-writeA text string which identifies the particular entry among the tributary unit entries.
SAG tu3CTPMonitor1.3.6.1.4.1.1038.110.120.2.1.6SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this tributary unit.
TU3 tu3CTPFailure1.3.6.1.4.1.1038.110.120.2.1.7Tu3CTPFailureread-onlyActive failures on tributary unit
SEV tu3CTPSeverity1.3.6.1.4.1.1038.110.120.2.1.8Severityread-onlyA reference to failure severity for tributary unit.
SEV tu3CTPAis1.3.6.1.4.1.1038.110.120.2.1.20Severityread-writeSeverity associed with Alarme Indication Signal failure for tributary unit.
SEV tu3CTPLop1.3.6.1.4.1.1038.110.120.2.1.21Severityread-writeSeverity associed with Loss Of Pointer failure for tributary unit.
vc3TTP1.3.6.1.4.1.1038.110.130
INT vc3TTPNumber1.3.6.1.4.1.1038.110.130.1INTEGERread-onlyNumber of virtual container order 3 in equipment.
vc3TTPTable1.3.6.1.4.1.1038.110.130.2not-accessibleList of virtual container order 3 in equipment.The number of records depends on the kinds of configured boards
vc3TTPEntry1.3.6.1.4.1.1038.110.130.2.1not-accessibleA particular virtual container order 3 of the equipment.
INT vc3TTPIndex1.3.6.1.4.1.1038.110.130.2.1.1INTEGERread-onlyA unique value which identify a particular virtual container order 3. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
INT vc3TTPSinkPointer1.3.6.1.4.1.1038.110.130.2.1.2INTEGERread-onlyA reference to the object which sends the data flow to this function on non-sdh physical port side.
VC3 vc3TTPSinkType1.3.6.1.4.1.1038.110.130.2.1.3Vc3TTPSinkTyperead-onlyA reference to the kind of the sink Pointer
STR vc3TTPName1.3.6.1.4.1.1038.110.130.2.1.5DisplayStringread-writeA text string which identifies the particular entry among the virtual container order 3 entries.
SAG vc3TTPMonitor1.3.6.1.4.1.1038.110.130.2.1.6SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this virtual container order 3.
VCL vc3TTPFailure1.3.6.1.4.1.1038.110.130.2.1.7VcLoFailureread-onlyActive failures on virtual container order 3
SEV vc3TTPSeverity1.3.6.1.4.1.1038.110.130.2.1.8Severityread-onlyA reference to failure severity for virtual container order 3.
OCT vc3TTPPathTraceExpected1.3.6.1.4.1.1038.110.130.2.1.9OCTET STRINGread-writeThe path trace is a user string that always follows the vc3. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace.
OCT vc3TTPPathTraceSent1.3.6.1.4.1.1038.110.130.2.1.10OCTET STRINGread-writeThe path trace is a user string that always follows the vc3. The value of this field is sent in j1 byte as path trace for this vc3. The default value is `all 0'.
OCT vc3TTPPathTraceReceived1.3.6.1.4.1.1038.110.130.2.1.11OCTET STRINGread-onlyThe path trace is a user string that always follows the vc3. The value is the actual path trace received in j1 byte
VC3 vc3TTPLabelExpected1.3.6.1.4.1.1038.110.130.2.1.12Vc3TTPSignalLabelread-onlyThe signal label indicates the multiplexing structure of the vc3. Usualy the value of this field cannot be modified as most equipment use the asynchronous bit multiplexing. For historical reasons the receipt of label `unspecified ' does not produce a Signal Label Mismatch failure.
VC3 vc3TTPLabelSent1.3.6.1.4.1.1038.110.130.2.1.13Vc3TTPSignalLabelread-writeThe signal label indicates the multiplexing structure of the vc3. The value of this field is sent as signal label for the vc3. The unspecified value is used for compatibilty with old sdh equipments. The `unequiped' value actives low order unequiped generator (lug). In this case all 1 signal is inserted down and up stream.
VC3 vc3TTPLabelReceived1.3.6.1.4.1.1038.110.130.2.1.14Vc3TTPSignalLabelread-onlyThe signal label indicates the multiplexing structure of the vc3. The value of this field is the actual received signal label for this vc3
INT vc3TTPSdThreshold1.3.6.1.4.1.1038.110.130.2.1.15INTEGERread-writeA Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold).
INT vc3TTPSesThreshold1.3.6.1.4.1.1038.110.130.2.1.16INTEGERread-onlyThe number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function
SAG vc3TTPBidirectionnal1.3.6.1.4.1.1038.110.130.2.1.17SagemBooleanread-writeIf set to false the equipment does not send Remote Defect Indication.
SEV vc3TTPRdi1.3.6.1.4.1.1038.110.130.2.1.20Severityread-writeSeverity associed with Remote Defect Indication failure for virtual container order 3.
SEV vc3TTPSd1.3.6.1.4.1.1038.110.130.2.1.21Severityread-writeSeverity associed with Signal Degrade failure for virtual container order 3.
SEV vc3TTPUneq1.3.6.1.4.1.1038.110.130.2.1.22Severityread-writeSeverity associed with virtual container UNEQuiped failure for virtual container order 3.
SEV vc3TTPPlm1.3.6.1.4.1.1038.110.130.2.1.23Severityread-writeSeverity associed with Path Label Mismatch failure for virtual container order 3.
SEV vc3TTPTim1.3.6.1.4.1.1038.110.130.2.1.24Severityread-writeSeverity associed with Trail Identifier Mismatch failure for virtual container order 3.
tu12CTP1.3.6.1.4.1.1038.110.140
INT tu12CTPNumber1.3.6.1.4.1.1038.110.140.1INTEGERread-onlyNumber of tributary unit in equipment.
tu12CTPTable1.3.6.1.4.1.1038.110.140.2not-accessibleList of tributary unit order 12 in equipment which are availables for new connection or used in the same connection level. In that case, an indication on the connection point Status is set into the tu12CTPStatus Variable. All tu12 CTP, which are involved in a different connection level (tu3 or au4), disappear from this List.
tu12CTPEntry1.3.6.1.4.1.1038.110.140.2.1not-accessibleA particular tributary unit of the equipment.
INT tu12CTPIndex1.3.6.1.4.1.1038.110.140.2.1.1INTEGERread-onlyA unique value which identify a particular tu12.
CTP tu12CTPStatus1.3.6.1.4.1.1038.110.140.2.1.2CTPStatusread-onlytu12 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP
STR tu12CTPName1.3.6.1.4.1.1038.110.140.2.1.5DisplayStringread-writeA text string which identifies the particular entry among the tributary unit entries.
SAG tu12CTPMonitor1.3.6.1.4.1.1038.110.140.2.1.6SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this tributary unit.
TU1 tu12CTPFailure1.3.6.1.4.1.1038.110.140.2.1.7Tu12CTPFailureread-onlyActive failures on tributary unit
SEV tu12CTPSeverity1.3.6.1.4.1.1038.110.140.2.1.8Severityread-onlyA reference to failure severity for tributary unit.
SEV tu12CTPAis1.3.6.1.4.1.1038.110.140.2.1.20Severityread-writeSeverity associed with Alarme Indication Signal failure for tributary unit.
SEV tu12CTPLop1.3.6.1.4.1.1038.110.140.2.1.21Severityread-writeSeverity associed with Loss Of Pointer failure for tributary unit.
vc12TTP1.3.6.1.4.1.1038.110.150
INT vc12TTPNumber1.3.6.1.4.1.1038.110.150.1INTEGERread-onlyNumber of virtual container order 12 in equipment.
vc12TTPTable1.3.6.1.4.1.1038.110.150.2not-accessibleList of virtual container order 12 in equipment.The number of records depends on the kinds of configured boards
vc12TTPEntry1.3.6.1.4.1.1038.110.150.2.1not-accessibleA particular virtual container order 12 of the equipment.
INT vc12TTPIndex1.3.6.1.4.1.1038.110.150.2.1.1INTEGERread-onlyA unique value which identify a particular virtual container order 12. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
INT vc12TTPSinkPointer1.3.6.1.4.1.1038.110.150.2.1.2INTEGERread-onlyA reference to the object which sends the data flow to this function on non-sdh physical port side.
VC1 vc12TTPSinkType1.3.6.1.4.1.1038.110.150.2.1.3Vc12TTPSinkTyperead-onlyA reference to the kind of the sink Pointer
STR vc12TTPName1.3.6.1.4.1.1038.110.150.2.1.5DisplayStringread-writeA text string which identifies the particular entry among the virtual container order 12 entries.
SAG vc12TTPMonitor1.3.6.1.4.1.1038.110.150.2.1.6SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this virtual container order 12.
VCL vc12TTPFailure1.3.6.1.4.1.1038.110.150.2.1.7VcLoFailureread-onlyActive failures on virtual container order 12
SEV vc12TTPSeverity1.3.6.1.4.1.1038.110.150.2.1.8Severityread-onlyA reference to failure severity for virtual container order 12.
OCT vc12TTPPathTraceExpected1.3.6.1.4.1.1038.110.150.2.1.9OCTET STRINGread-writeThe path trace is a user string that always follows the vc12. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace.
OCT vc12TTPPathTraceSent1.3.6.1.4.1.1038.110.150.2.1.10OCTET STRINGread-writeThe path trace is a user string that always follows the vc12. The value of this field is sent in j2 byte as path trace for this vc12. The default value is `all 0'.
OCT vc12TTPPathTraceReceived1.3.6.1.4.1.1038.110.150.2.1.11OCTET STRINGread-onlyThe path trace is a user string that always follows the vc12. The value is the actual path trace received in j2 byte
VC1 vc12TTPLabelExpected1.3.6.1.4.1.1038.110.150.2.1.12Vc12TTPSignalLabelread-onlyThe signal label indicates the multiplexing structure of the vc12. Usualy the value of this field cannot be modified as most equipment use the asynchronous bit multiplexing. For historical reasons the receipt of label `unspecified ' does not produce a Signal Label Mismatch failure.
VC1 vc12TTPLabelSent1.3.6.1.4.1.1038.110.150.2.1.13Vc12TTPSignalLabelread-writeThe signal label indicates the multiplexing structure of the vc12. The value of this field is sent as signal label for the vc12. The unspecified value is used for compatibilty with old sdh equipments. The `unequiped' value actives low order unequiped generator (lug). In this case all 1 signal is inserted down and up stream.
VC1 vc12TTPLabelReceived1.3.6.1.4.1.1038.110.150.2.1.14Vc12TTPSignalLabelread-onlyThe signal label indicates the multiplexing structure of the vc12. The value of this field is the actual received signal label for this vc12
INT vc12TTPSdThreshold1.3.6.1.4.1.1038.110.150.2.1.15INTEGERread-writeA Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold).
INT vc12TTPSesThreshold1.3.6.1.4.1.1038.110.150.2.1.16INTEGERread-onlyThe number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function
SAG vc12TTPBidirectionnal1.3.6.1.4.1.1038.110.150.2.1.17SagemBooleanread-writeIf set to false the equipment does not send Remote Defect Indication.
SEV vc12TTPRdi1.3.6.1.4.1.1038.110.150.2.1.20Severityread-writeSeverity associed with Remote Defect Indication failure for virtual container order 12.
SEV vc12TTPSd1.3.6.1.4.1.1038.110.150.2.1.21Severityread-writeSeverity associed with Signal Degrade failure for virtual container order 12.
SEV vc12TTPUneq1.3.6.1.4.1.1038.110.150.2.1.22Severityread-writeSeverity associed with virtual container UNEQuiped failure for virtual container order 12.
SEV vc12TTPPlm1.3.6.1.4.1.1038.110.150.2.1.23Severityread-writeSeverity associed with Path Label Mismatch failure for virtual container order 12.
SEV vc12TTPTim1.3.6.1.4.1.1038.110.150.2.1.24Severityread-writeSeverity associed with Trail Identifier Mismatch failure for virtual container order 12.
nspiCTP1.3.6.1.4.1.1038.110.160
INT nspiCTPNumber1.3.6.1.4.1.1038.110.160.1INTEGERread-onlyA unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
nspiCTPTable1.3.6.1.4.1.1038.110.160.2not-accessibleList of non-sdh physical port in equipment.
nspiCTPEntry1.3.6.1.4.1.1038.110.160.2.1not-accessibleA particular non-sdh physical port of the equipment.
INT nspiCTPIndex1.3.6.1.4.1.1038.110.160.2.1.1INTEGERread-onlyA unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
NSP nspiCTPTTPType1.3.6.1.4.1.1038.110.160.2.1.2NspiSrcTyperead-onlyThe type of VC which is associated to the nspi interface.
CTP nspiCTPStatus1.3.6.1.4.1.1038.110.160.2.1.3CTPStatusread-onlynspi connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP
STR nspiCTPName1.3.6.1.4.1.1038.110.160.2.1.4DisplayStringread-writeA text string which identifies the particular entry among the non-sdh physical port entries.
nspiTTP1.3.6.1.4.1.1038.110.170
INT nspiTTPNumber1.3.6.1.4.1.1038.110.170.1INTEGERread-onlyA unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
nspiTTPTable1.3.6.1.4.1.1038.110.170.2not-accessibleList of non-sdh physical port in equipment.
nspiTTPEntry1.3.6.1.4.1.1038.110.170.2.1not-accessibleA particular non-sdh physical port of the equipment.
INT nspiTTPIndex1.3.6.1.4.1.1038.110.170.2.1.1INTEGERread-onlyA unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
NSP nspiTTPType1.3.6.1.4.1.1038.110.170.2.1.2NspiTTPTyperead-onlyThe type of media for the nspi interface.
NSP nspiTTPLevel1.3.6.1.4.1.1038.110.170.2.1.3NspiTTPLevelread-onlyThe rate level of the nspi interface.
STR nspiTTPName1.3.6.1.4.1.1038.110.170.2.1.4DisplayStringread-writeA text string which identifies the particular entry among the non-sdh physical port entries.
INT nspiTTPBoardIndex1.3.6.1.4.1.1038.110.170.2.1.5INTEGERread-onlyIndex of the Board that supports the physical acces of this interface
INT nspiTTPBoardAcces1.3.6.1.4.1.1038.110.170.2.1.6INTEGERread-onlyFriendly Index of the physical acces on the Board that supports the interface
NSP nspiTTPSrcType1.3.6.1.4.1.1038.110.170.2.1.7NspiSrcTyperead-onlyA reference to the type of object which sends the data flow to this interface. Usually the value is vc12, vc3 or vc4 types.
INT nspiTTPSrcPointer1.3.6.1.4.1.1038.110.170.2.1.8INTEGERread-onlyA reference to the object which sends the data flow to this interface. Usually the value is the Index of a vc12, vc3 or vc4.
SAG nspiTTPMonitor1.3.6.1.4.1.1038.110.170.2.1.9SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this non-sdh physical port.
NSP nspiTTPFailure1.3.6.1.4.1.1038.110.170.2.1.10NspiTTPFailureread-onlyActive failures on non-sdh physical port
SEV nspiTTPSeverity1.3.6.1.4.1.1038.110.170.2.1.11Severityread-onlyA reference to failure severity for non-sdh physical port.
LOO nspiTTPLoopback1.3.6.1.4.1.1038.110.170.2.1.14Loopbackread-writeThis field gives the active loopback status on the non-sdh physical port. When its value is `line' the data flow recieved from the port side is sent back to the line. When its value is `equipment' the data flow recieved form equipment side is send back. The field can be set to a particular loopback value, even if there no garantee that the loopback is really done. The real loopback status of the interface must be checked in the response. The loopback can be cleared by the equipment when it cannot remain for any reason.
SEV nspiTTPLos1.3.6.1.4.1.1038.110.170.2.1.20Severityread-writeSeverity associed with Loss Of Signal failure for non-sdh physical port.
SEV nspiTTPAis1.3.6.1.4.1.1038.110.170.2.1.21Severityread-writeSeverity associed with Alarme Indication Signal failure for non-sdh physical port.
channel1.3.6.1.4.1.1038.110.180
INT channelNumber1.3.6.1.4.1.1038.110.180.1INTEGERread-onlyNumber of SDH Channels in equipment.
channelTable1.3.6.1.4.1.1038.110.180.2not-accessibleList of SDH Channels in equipment.
channelEntry1.3.6.1.4.1.1038.110.180.2.1not-accessibleA particular SDH Channel of the equipment.
INT channelIndex1.3.6.1.4.1.1038.110.180.2.1.1INTEGERread-onlyA unique value which identify a particular SDH Channel. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
CHA channelEncaps1.3.6.1.4.1.1038.110.180.2.1.2ChannelEncapsread-writeThe type of encapsulation used to map Data stream into Sdh containers
INT channelNbVc41.3.6.1.4.1.1038.110.180.2.1.5INTEGERread-writeNumber of VC4 into the channel.
INT channelNbVc31.3.6.1.4.1.1038.110.180.2.1.6INTEGERread-writeNumber of VC3 into the channel.
INT channelNbVc121.3.6.1.4.1.1038.110.180.2.1.7INTEGERread-writeNumber of VC12 into the channel.
CHA channelConcat1.3.6.1.4.1.1038.110.180.2.1.8ChannelConcatread-writeThe type of Concatenation used within the channel
INT channelAdminStatus1.3.6.1.4.1.1038.110.180.2.1.9INTEGERread-writeThe desired state of the channel. The testing(3) state indicates that no operational packets can be passed.
INT channelOperStatus1.3.6.1.4.1.1038.110.180.2.1.10INTEGERread-onlyThe current operational state of the channel. The testing(3) state indicates that no operational packets can be passed.
INT channelFirstIndex1.3.6.1.4.1.1038.110.180.2.1.11INTEGERread-writeIndex of the first Vc in the Channel when it is configured. Otherwise this field is set to 0.
INT channelDelay1.3.6.1.4.1.1038.110.180.2.1.12INTEGERread-writeThis field give the maximum delay (in millisecondes) for receiving virtual concatenated frames. This field is set to 0 when channelConcat is different to virtual(1)
SAG channelMonitor1.3.6.1.4.1.1038.110.180.2.1.13SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this channel.
CHA channelFailure1.3.6.1.4.1.1038.110.180.2.1.14ChannelFailureread-onlyActive failures on channel
SEV channelSeverity1.3.6.1.4.1.1038.110.180.2.1.15Severityread-onlyA reference to failure severity for non-sdh physical port.
SEV channelLoa1.3.6.1.4.1.1038.110.180.2.1.16Severityread-writeSeverity associated with Loss Of Alignment failure for channel.
SEV channelLom1.3.6.1.4.1.1038.110.180.2.1.17Severityread-writeSeverity associated with Loss Of Multiframe failure for channel.
SEV channelSqm1.3.6.1.4.1.1038.110.180.2.1.18Severityread-writeSeverity associated with Sequence Mismatch failure for channel.
bandwidth1.3.6.1.4.1.1038.110.190
INT bandwidthNumber1.3.6.1.4.1.1038.110.190.1INTEGERread-onlyNumber of bandwidth units which are available in the equipement. The number of units depends on their type (Vc4, Vc3, Vc12), on the number of Data card and on the bandwidth size which has been configured for this card. For a Data card which is mapped on a STM16, there are 16 Vc4 entries (or 3*16 Vc3 entries or 63*16 Vc12 entries) in the BandwidthTable.
bandwidthTable1.3.6.1.4.1.1038.110.190.2not-accessibleList of Bandwidth units in equipment. It represent the bandwidth occupation of each non-sdh card
bandwidthEntry1.3.6.1.4.1.1038.110.190.2.1not-accessibleA particular unit part of a non-sdh card bandwidth.
INT bandwidthIndex1.3.6.1.4.1.1038.110.190.2.1.1INTEGERread-onlyA unique value which identify a particular unit of a non-sdh card bandwidth. The value of index is a Vc Index which change when bandwidthSrcType value is modified.
INT bandwidthBoardIndex1.3.6.1.4.1.1038.110.190.2.1.2INTEGERread-onlyIndex of the Board that supports the bandwidth unit.
NSP bandwidthSrcType1.3.6.1.4.1.1038.110.190.2.1.3NspiSrcTyperead-writeDefine the decomposition level of the bandwidth.
INT bandwidthSrcPointer1.3.6.1.4.1.1038.110.190.2.1.4INTEGERread-onlythis field is set to bandwidthIndex when the unit is used by a channel and set to 0 otherwise. It defines the TTP and CTP index associated to the channel.
NSP bandwidthSinkType1.3.6.1.4.1.1038.110.190.2.1.5NspiSrcTyperead-writeA reference to the kind of the sink Pointer. Usually the value is Channel.
INT bandwidthSinkPointer1.3.6.1.4.1.1038.110.190.2.1.6INTEGERread-writeA reference to the object which sends the data flow to this function on unsynchronous port interface side. This pointer corresponds to an index in the channelTable.
INT bandwidthAdminStatus1.3.6.1.4.1.1038.110.190.2.1.7INTEGERread-writeThe desired state of the Vc. The testing(3) state indicates that no operational packets can be passed.
INT bandwidthOperStatus1.3.6.1.4.1.1038.110.190.2.1.8INTEGERread-onlyThe current operational state of the Vc. The testing(3) state indicates that no operational packets can be passed.
INT bandwidthPrevIndex1.3.6.1.4.1.1038.110.190.2.1.9INTEGERread-onlyA reference to the previous VC into the channel. This field is set to 0 if the VC is not associated to a channel or if it is the first Vc of the channel.
INT bandwidthNextIndex1.3.6.1.4.1.1038.110.190.2.1.10INTEGERread-onlyA reference to the next VC into the channel. This field is set to 0 if the VC is not associated to a channel or if it is the last Vc of the channel.

RFC description

Defines SDH transmission path management following ETSI ETS 300 304 standard structure.

Start monitoring SAGEM-Tolbiac SDH transmission network-element equipment (termination-point alarm severity/loopback) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download SDH-ETS-MIB