SDH-ETS-MIB :: msTTPMonitor

MIB Reference — IPNetwork Monitor · Updated September 26, 2026

All MIBs › SDH-ETS-MIB › msTTPMonitor

msTTPMonitor

Module: SDH-ETS-MIB

OID (symbolic): SDH-ETS-MIB::msTTPMonitor

OID (numeric): 1.3.6.1.4.1.1038.110.30.2.1.3

Node type: OBJECT-TYPE

Type: SagemBoolean

Access: read-write

Description: When the value of this field is set to false, the failure detection is stopped for this multiplex section terminaison.

What is msTTPMonitor?

When set to false, disables failure detection at the multiplex-section layer for this interface, letting an operator suppress alarms on a section intentionally taken out of service.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1038.110.30.2.1.3
snmpwalk -v2c -c public <target> SDH-ETS-MIB::msTTPMonitor

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1038.110.30.2.1.3.1
snmpget -v2c -c public <target> SDH-ETS-MIB::msTTPMonitor.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1038.110.30.2.1.3.1 s <value>

Start monitoring SAGEM-Tolbiac SDH transmission network-element equipment (termination-point alarm severity/loopback) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SDH-ETS-MIB::msTTPMonitor OID value, configure state conditions and alerts, and monitor any SAGEM-Tolbiac SDH transmission network-element equipment (termination-point alarm severity/loopback) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1038sagemDrSAGEM-DR-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1038.110sdhEtsSDH-ETS-MIB
1.3.6.1.4.1.1038.110.30msTTPSDH-ETS-MIB
1.3.6.1.4.1.1038.110.30.2msTTPTableSDH-ETS-MIB
1.3.6.1.4.1.1038.110.30.2.1msTTPEntrySDH-ETS-MIB
1.3.6.1.4.1.1038.110.30.2.1.3msTTPMonitorSDH-ETS-MIB