SHELF-MIB

MIB Reference — IPNetwork Monitor

All MIBsSHELF-MIB

Organization: SAGEM-Tolbiac drd/ddp/tmhd

Last Updated: 2000-12-06

Category: Microwave Radio - SAGEM

Description:

Manages SAGEM shelf chassis slot configuration, card inventory, and power distribution status.

Imported Objects

From EQUIPMENT-MIB

SagemBoolean
Severity

From SAGEM-DR-MIB

sagemDrMODULE-IDENTITY

From SNMPv2-SMI

Counter32
MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

DisplayString

What Is SHELF-MIB?

SHELF-MIB is a vendor-specific MIB for SAGEM ADR (Access and transmission) equipment, modeling the physical shelf/chassis structure of the device including slot layout, installed card inventory, and power distribution. Its data category is hardware inventory and status: which cards occupy which slots, what type each card is, and the health of the shelf's power feeds. Its monitoring purpose is squarely hardware status tracking, letting an administrator confirm that expected line/service cards are present and recognized in their slots and that shelf power distribution is functioning normally, which is critical on modular access/transmission shelves where a power or slot fault can take down multiple subscriber-facing circuits at once. It is part of SAGEM's broader ADR equipment MIB family and would work alongside interface- and service-specific MIBs covering the traffic carried by those cards. It is deployed in telecom access network sites using SAGEM ADR transmission/access shelf equipment. Engineers can download the SHELF-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in SHELF-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • SAGEM ADR access/transmission shelf equipment

Monitoring Examples

No sample objects were provided for this module in the available data, so a concrete polling scenario referencing real object names cannot be constructed without inventing unconfirmed names; based on the module description, a shelf/slot/card inventory table with power status objects would be expected but specific object names are not confirmed here.

OIDs
OID symbolicOID numericTypeAccessDescription
shelf1.3.6.1.4.1.1038.150The MIB module specific for ADR equipment
SAG adrHotReset1.3.6.1.4.1.1038.150.1SagemBooleanread-writeSoftware hot reset when this variable is set to TRUE
led1.3.6.1.4.1.1038.150.2
INT ledNumber1.3.6.1.4.1.1038.150.2.1INTEGERread-onlyNumber of led in equipment.
ledTable1.3.6.1.4.1.1038.150.2.2not-accessibleList of led in equipment.
ledEntry1.3.6.1.4.1.1038.150.2.2.1not-accessibleA particular led of the equipment.
INT ledIndex1.3.6.1.4.1.1038.150.2.2.1.1INTEGERread-onlyA unique value which identify a particular led.
INT ledPosition1.3.6.1.4.1.1038.150.2.2.1.2INTEGERread-onlyA reference to the associated Board on the equipment.
LED ledType1.3.6.1.4.1.1038.150.2.2.1.3LedTyperead-onlyType of the Led.
LED ledStatus1.3.6.1.4.1.1038.150.2.2.1.4LedStatusread-onlyStatus of this Led.
holdTime1.3.6.1.4.1.1038.150.3
HOL adrFailHoldOffTime1.3.6.1.4.1.1038.150.3.1HoldTimeread-writeFailure hold off time : the time interval during which the defect is present and the failure is not raised
HOL adrFailHoldOnTime1.3.6.1.4.1.1038.150.3.2HoldTimeread-writeFailure hold on time : the time interval during which the defect is cleared and the failure is not
board1.3.6.1.4.1.1038.150.20
INT boardNumber1.3.6.1.4.1.1038.150.20.1INTEGERread-onlyNumber of board in equipment.
boardTable1.3.6.1.4.1.1038.150.20.2not-accessibleList of board in equipment.
boardEntry1.3.6.1.4.1.1038.150.20.2.1not-accessibleA particular board of the equipment.
INT boardIndex1.3.6.1.4.1.1038.150.20.2.1.1INTEGERread-onlyA unique value which identify a particular slot. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to hardware. Each equipment maintain its own pool of values: ex ADR155c : A = 1, B = 2, ... M = 5, Fan = 6 ex ADR2500c: Fan = 1, PSU1 = 2, ...Trib1 = 8, Trib6= 13, Line1 = 14,... Switch2 = 17, Shelf = 18
STR boardSlotName1.3.6.1.4.1.1038.150.20.2.1.2DisplayStringread-onlyA DisplayString which identify the name of a particular slot. Its value is fixed at equipment design time. It is usualy related to hardware ex ADR155c : A, B, ... Fan ex ADR2500c: Fan, CCU, CTRL, PSU1, ... TRIB5, .... SWITCH1, ...
INT boardExpectType1.3.6.1.4.1.1038.150.20.2.1.3INTEGERread-writeA value which configure the expected type. If used, this one must be equal to one of existent boardListIndex for the considerated board. Otherwise, the value is set to 0. Known types are readable in boardListTable
INT boardInsertType1.3.6.1.4.1.1038.150.20.2.1.4INTEGERread-onlyWhen the inserted board doesn't match with the expexted board the boardMismatch failure is generated. The type of the card could be found in hardware inventory.
STR boardExpectFamily1.3.6.1.4.1.1038.150.20.2.1.5DisplayStringread-onlyBoard Family corresponding to the specified expected kind. This value is send by the equipment. ex ADR155c : ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
STR boardInsertFamily1.3.6.1.4.1.1038.150.20.2.1.6DisplayStringread-onlyBoard Family corresponding to the type of inserted board. ex ADR155c : ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
SAG boardActive1.3.6.1.4.1.1038.150.20.2.1.7SagemBooleanread-writeWhen the value of this field is set to false, the transmission of this board stop and the board could properly be extracted
INT boardFirstPortIndex1.3.6.1.4.1.1038.150.20.2.1.8INTEGERread-onlyIf the card is a card with physical ports, then the value is the first index of a physical interface (SPI, PPI) in the mib SDH-ETS. Else, the value is 0.
PRO boardProtectionType1.3.6.1.4.1.1038.150.20.2.1.9ProtectionTyperead-writeThe value of this field indicates the kind of wanted card protection. The default value is NONE. if value is changed in cardP(1)then an entry is created in cardpTable. But this table has to be completed (by setting the cardpReliefIndex,...) to obtain a configured protection. if value is changed in None(0)then the associated entry in cardpTable is deleted. Some cards don't accept any protection. In that case, the value of this field will remain to NONE
SAG boardMonitor1.3.6.1.4.1.1038.150.20.2.1.10SagemBooleanread-writeWhen the value of this field is set to false, the failure detection is stopped for this board.
BOA boardFailure1.3.6.1.4.1.1038.150.20.2.1.11BoardFailureread-onlyActive failures on board
SEV boardSeverity1.3.6.1.4.1.1038.150.20.2.1.12Severityread-onlyA reference to failure severity for boards.
SEV boardMissingSev1.3.6.1.4.1.1038.150.20.2.1.13Severityread-writeA reference to failure severity for boards.
SEV boardMismatchSev1.3.6.1.4.1.1038.150.20.2.1.14Severityread-writeA reference to failure severity for boards.
SEV boardDefectiveSev1.3.6.1.4.1.1038.150.20.2.1.15Severityread-writeA reference to failure severity for boards.
boardList1.3.6.1.4.1.1038.150.30
INT boardListNumber1.3.6.1.4.1.1038.150.30.1INTEGERread-onlyNumber of entry of the boardList Table
boardListTable1.3.6.1.4.1.1038.150.30.2not-accessibleList of board type able to be managed by this equipment . In order to manage a new type, just insert the board and if the family match with a known family, this table will be expand automaticaly with the new type inserted The XX fist value defined ( with boardSlotName = Shelf = 18 for ADR2500c) is a list all possible type of boardInsertedType.
boardListEntry1.3.6.1.4.1.1038.150.30.2.1not-accessibleA particular boardList of the equipment.
INT boardListIndex1.3.6.1.4.1.1038.150.30.2.1.1INTEGERread-onlyA unique value.
INT boardListSlot1.3.6.1.4.1.1038.150.30.2.1.2INTEGERread-onlyA reference to the corresponding Slot.
STR boardListType1.3.6.1.4.1.1038.150.30.2.1.3DisplayStringread-onlyIn order to manage a new type, just insert the board and if the family match with a known family, this table will be expand automaticaly with the new type inserted. ex ADR155c : ex ADR2500c: 4S1.1, S4.1, L16.2, SWITCH, ...
softInv1.3.6.1.4.1.1038.150.40
INT softInventoryNumber1.3.6.1.4.1.1038.150.40.1INTEGERread-onlyNumber of entry of the softInventory Table
softInventoryTable1.3.6.1.4.1.1038.150.40.2not-accessibleList of software inventory used
softInventoryEntry1.3.6.1.4.1.1038.150.40.2.1not-accessibleA particular boardList of the equipment.
INT softInventoryIndex1.3.6.1.4.1.1038.150.40.2.1.1INTEGERread-onlyA unique value.
INT softInventoryBoard1.3.6.1.4.1.1038.150.40.2.1.2INTEGERread-onlyA reference to the corresponding Slot. This variable is needed because some boards have their owns Applicative and Boot codes.
STR softInventoryType1.3.6.1.4.1.1038.150.40.2.1.3DisplayStringread-onlyIndication of type software
STR softInventoryCode1.3.6.1.4.1.1038.150.40.2.1.4DisplayStringread-onlyIndication of version code
STR softInventoryExt1.3.6.1.4.1.1038.150.40.2.1.5DisplayStringread-onlyIndication of extension code. This one is not mandatory.
hardInv1.3.6.1.4.1.1038.150.50
INT hardInventoryNumber1.3.6.1.4.1.1038.150.50.1INTEGERread-onlyNumber of different hardware inventory in equipment.
hardInventoryTable1.3.6.1.4.1.1038.150.50.2not-accessibleList of hardware inventory in equipment. A hardware inventory is a description associed to a particular card
hardInventoryEntry1.3.6.1.4.1.1038.150.50.2.1not-accessibleA particular tInv of the equipment.
INT hardInventoryIndex1.3.6.1.4.1.1038.150.50.2.1.1INTEGERread-onlyIndex of the inventory entry that corresponds to a particular slot
STR hardInventoryBoard1.3.6.1.4.1.1038.150.50.2.1.2DisplayStringread-onlyFamily of card inserted in the slot
STR hardInventoryDescr1.3.6.1.4.1.1038.150.50.2.1.3DisplayStringread-onlyThe content of the inventory: a textual description
laser1.3.6.1.4.1.1038.150.100
INT laserNumber1.3.6.1.4.1.1038.150.100.1INTEGERread-onlyNumber of optical interface in equipment.
laserTable1.3.6.1.4.1.1038.150.100.2not-accessibleList of synchronous physical interface in equipment.
laserEntry1.3.6.1.4.1.1038.150.100.2.1not-accessibleA particular synchronous physical interface of the equipment.
INT laserIndex1.3.6.1.4.1.1038.150.100.2.1.1INTEGERread-only
SAG laserTxEnable1.3.6.1.4.1.1038.150.100.2.1.2SagemBooleanread-writeEnable(true) or disable(false) the laser output of the interface.
SAG laserALSEnable1.3.6.1.4.1.1038.150.100.2.1.3SagemBooleanread-writeAutomatic Laser Shutdown enable(true) or disable(false). When enabled, this function cuts the laser output when a los is detected on input signal.
SAG laserALSRestart2s1.3.6.1.4.1.1038.150.100.2.1.4SagemBooleanread-writeOperator command to start a one shot emission during 2s.
SAG laserALSRestart90s1.3.6.1.4.1.1038.150.100.2.1.5SagemBooleanread-writeOperator command to start a one shot emission during 90s.
eow1.3.6.1.4.1.1038.150.120
INT eowNumber1.3.6.1.4.1.1038.150.120.1INTEGERread-onlyNumber of EOW port in equipment.
eowTable1.3.6.1.4.1.1038.150.120.2not-accessibleList of EOW port in equipment.
eowEntry1.3.6.1.4.1.1038.150.120.2.1not-accessibleA particular EOW port of the equipment.
INT eowIndex1.3.6.1.4.1.1038.150.120.2.1.1INTEGERread-onlyA unique value which identify a particular EOW port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
STR eowName1.3.6.1.4.1.1038.150.120.2.1.2DisplayStringread-onlyA text string which identifies the particular entry among the EOW port entries.
EOW eowSrcType1.3.6.1.4.1.1038.150.120.2.1.6EOWTyperead-writeA reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection.
INT eowSrcPtr1.3.6.1.4.1.1038.150.120.2.1.7INTEGERread-writeA reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection.
EOW eowSinkType1.3.6.1.4.1.1038.150.120.2.1.8EOWTyperead-writeA reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection.
INT eowSinkPtr1.3.6.1.4.1.1038.150.120.2.1.9INTEGERread-writeA reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection.
EOW eowClockMode1.3.6.1.4.1.1038.150.120.2.1.10EOWClockModeread-writeSelect the direction of the two external synchronisation lines.

RFC description

SAGEM ADR equipment shelf management MIB covering hardware modules, board configuration, and system monitoring.

Start monitoring SAGEM ADR access/transmission shelf equipment (slot/card inventory and power-feed status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.