All MIBs › RITTAL-CMC-TC-MIB
Category: Environmental Monitoring
Description: Defines textual conventions and enumerated types for the Rittal CMC monitoring system MIBs.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is RITTAL-CMC-TC-MIB?
RITTAL-CMC-TC-MIB is a textual-conventions-only support module for the Rittal CMC (Computer Multi Control) environmental monitoring system MIB family, used in Rittal server-rack enclosures to monitor rack-level environmental conditions such as temperature, humidity, and access/door status. As a TC (Textual Convention) module it defines shared data types and enumerations reused by the operational Rittal CMC MIBs rather than any managed objects or tables of its own, so it exposes no directly pollable runtime data. Consequently it has no monitoring role by itself; its purpose is purely to standardize value ranges and status enumerations (e.g., sensor status codes) referenced by the companion Rittal CMC data MIBs that report temperature, humidity, fan, and door-contact status. It is explicitly a dependency of the other Rittal CMC MIB modules rather than depending on external standards itself. It is used wherever Rittal CMC environmental monitoring units are deployed, typically in data-center server racks and enclosures. Network engineers evaluating or troubleshooting this functionality can download the RITTAL-CMC-TC-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in RITTAL-CMC-TC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Rittal CMC (Computer Multi Control) rack environmental monitoring unit
Monitoring Examples
This module defines only textual conventions (shared data types/enumerations) with no managed objects or tables of its own, so there is no monitoring scenario to describe; its objects are consumed by other Rittal CMC MIBs that expose the actual temperature, humidity, and door-status data for a Rittal rack enclosure.
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| enterprises |
From RFC1213-MIB
| DisplayString | |
| sysContact | |
| sysDescr | |
| sysLocation | |
| sysName |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| rittal | 1.3.6.1.4.1.2606 | |||
| cmcTc | 1.3.6.1.4.1.2606.4 | |||
| NTF alarmSensorUnit1 | 1.3.6.1.4.1.2606.4.0.1 | Alarm of Sensor unit 1 | ||
| NTF alarmSensorUnit2 | 1.3.6.1.4.1.2606.4.0.2 | Alarm of sensor unit 2 | ||
| NTF alarmSensorUnit3 | 1.3.6.1.4.1.2606.4.0.3 | Alarm of sensor unit 3 | ||
| NTF alarmSensorUnit4 | 1.3.6.1.4.1.2606.4.0.4 | Alarm of sensor unit 4 | ||
| NTF alarmUnit1 | 1.3.6.1.4.1.2606.4.0.5 | Alarm of unit 1 | ||
| NTF alarmUnit2 | 1.3.6.1.4.1.2606.4.0.6 | Alarm of unit 2 | ||
| NTF alarmUnit3 | 1.3.6.1.4.1.2606.4.0.7 | Alarm of unit 3 | ||
| NTF alarmUnit4 | 1.3.6.1.4.1.2606.4.0.8 | Alarm of unit 4 | ||
| NTF alarmValues | 1.3.6.1.4.1.2606.4.0.9 | Alarm of values measured by external card | ||
| NTF configChanged | 1.3.6.1.4.1.2606.4.0.10 | The configuration of the cmc has changed, this trap is send if new setup is saved. Configuration can be changed by Terminal, Telnet, Web or SNMP *** NOT IMPLEMENTED *** | ||
| cmcTcMibRev | 1.3.6.1.4.1.2606.4.1 | |||
| INT cmcTcMibMajRev | 1.3.6.1.4.1.2606.4.1.1 | INTEGER | read-only | The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information, correct interpretation of data may require a MIB document with the same major revision level. |
| INT cmcTcMibMinRev | 1.3.6.1.4.1.2606.4.1.2 | INTEGER | read-only | The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred. |
| INT cmcTcMibCondition | 1.3.6.1.4.1.2606.4.1.3 | INTEGER | read-only | The overall condition (status) of the system represented by this MIB. (2) OK (3) a minor problem, warning condition (yellow LED on CMC) (4) a major problem (red LED on CMC) (5) configuration of sensor units changed or unit detected (red/yellow/green LED on CMC) |
| cmcTcStatus | 1.3.6.1.4.1.2606.4.2 | |||
| INT cmcTcStatusDeviceCMC | 1.3.6.1.4.1.2606.4.2.1 | INTEGER | read-only | General Status of CMC-TC unit itself (1) failed (2) OK |
| INT cmcTcUnitsConnected | 1.3.6.1.4.1.2606.4.2.2 | INTEGER | read-only | Number of sensor units connected to the CMC, Port 1 to 4 |
| cmcTcStatusSensorUnit1 | 1.3.6.1.4.1.2606.4.2.3 | |||
| INT cmcTcUnit1TypeOfDevice | 1.3.6.1.4.1.2606.4.2.3.1 | INTEGER | read-only | Type of sensor unit connected to port 1 |
| STR cmcTcUnit1Text | 1.3.6.1.4.1.2606.4.2.3.2 | DisplayString | read-write | Descriptional text for sensor unit connected to port 1 |
| INT cmcTcUnit1Serial | 1.3.6.1.4.1.2606.4.2.3.3 | INTEGER | read-only | Serialnumber of sensor unit connected to port 1 |
| INT cmcTcUnit1Status | 1.3.6.1.4.1.2606.4.2.3.4 | INTEGER | read-only | General Status sensor unit connected to port 1 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low |
| cmcTcStatusUnit1Sensors | 1.3.6.1.4.1.2606.4.2.3.5 | |||
| INT cmcTcUnit1NumberOfSensors | 1.3.6.1.4.1.2606.4.2.3.5.1 | INTEGER | read-only | Number of sensors connected to sensor unit 1 |
| cmcTcUnit1SensorTable | 1.3.6.1.4.1.2606.4.2.3.5.2 | not-accessible | Headline of sensor table | |
| cmcTcUnit1SensorEntry | 1.3.6.1.4.1.2606.4.2.3.5.2.1 | not-accessible | Entries of sensor table | |
| INT unit1SensorIndex | 1.3.6.1.4.1.2606.4.2.3.5.2.1.1 | INTEGER | read-only | Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfSensors. |
| INT unit1SensorType | 1.3.6.1.4.1.2606.4.2.3.5.2.1.2 | INTEGER | read-only | Type of sensor which is connected to sensor unit 1 to sensor[unit1SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage (OK, NOK) 18: voltage value 19: fan status, from CMC-TC-FAS-Unit 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit |
| STR unit1SensorText | 1.3.6.1.4.1.2606.4.2.3.5.2.1.3 | DisplayString | read-write | Descriptional text for each sensor (entry in the table) |
| INT unit1SensorStatus | 1.3.6.1.4.1.2606.4.2.3.5.2.1.4 | INTEGER | read-only | Actual status of the sensor |
| INT unit1SensorValue | 1.3.6.1.4.1.2606.4.2.3.5.2.1.5 | INTEGER | read-only | Value of sensor |
| INT unit1SensorSetHigh | 1.3.6.1.4.1.2606.4.2.3.5.2.1.6 | INTEGER | read-write | Value for high setpoint of sensor |
| INT unit1SensorSetLow | 1.3.6.1.4.1.2606.4.2.3.5.2.1.7 | INTEGER | read-write | Value for low setpoint of sensor, also used as alarm delay |
| INT unit1SensorSetWarn | 1.3.6.1.4.1.2606.4.2.3.5.2.1.8 | INTEGER | read-write | Value for warning setpoint of sensor, also used as fan threshold |
| cmcTcStatusUnit1Outputs | 1.3.6.1.4.1.2606.4.2.3.6 | |||
| INT cmcTcUnit1NumberOfOutputs | 1.3.6.1.4.1.2606.4.2.3.6.1 | INTEGER | read-only | Number of outputs available on sensor unit 1 |
| cmcTcUnit1OutputTable | 1.3.6.1.4.1.2606.4.2.3.6.2 | not-accessible | Headline of output table | |
| cmcTcUnit1OutputEntry | 1.3.6.1.4.1.2606.4.2.3.6.2.1 | not-accessible | Entries of output table | |
| INT unit1OutputIndex | 1.3.6.1.4.1.2606.4.2.3.6.2.1.1 | INTEGER | read-only | Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfOutputs. |
| INT unit1OutputType | 1.3.6.1.4.1.2606.4.2.3.6.2.1.2 | INTEGER | read-only | Type of output which is connected to sensor unit 1 to output[unit1OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) |
| STR unit1OutputText | 1.3.6.1.4.1.2606.4.2.3.6.2.1.3 | DisplayString | read-write | Descriptional text for each output (entry in the table) |
| INT unit1OutputStatus | 1.3.6.1.4.1.2606.4.2.3.6.2.1.4 | INTEGER | read-write | Actual status of the output |
| INT unit1OutputValue | 1.3.6.1.4.1.2606.4.2.3.6.2.1.5 | INTEGER | read-write | Value for output |
| INT unit1OutputSet | 1.3.6.1.4.1.2606.4.2.3.6.2.1.6 | INTEGER | read-write | Command for output |
| INT unit1OutputConfig | 1.3.6.1.4.1.2606.4.2.3.6.2.1.7 | INTEGER | read-write | Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control |
| INT unit1OutputDelay | 1.3.6.1.4.1.2606.4.2.3.6.2.1.8 | INTEGER | read-write | Unsigned Value for delay, after this time the output will fall into the previous state |
| INT unit1OutputTimeoutAction | 1.3.6.1.4.1.2606.4.2.3.6.2.1.9 | INTEGER | read-write | State for output if timeout (RS422) occurs |
| cmcTcStatusUnit1Msg | 1.3.6.1.4.1.2606.4.2.3.7 | |||
| INT cmcTcUnit1NumberOfMsgs | 1.3.6.1.4.1.2606.4.2.3.7.1 | INTEGER | read-only | Number of messages that can be created with sensor unit 1 |
| cmcTcUnit1MsgTable | 1.3.6.1.4.1.2606.4.2.3.7.2 | not-accessible | Headline of message table | |
| cmcTcUnit1MsgEntry | 1.3.6.1.4.1.2606.4.2.3.7.2.1 | not-accessible | Entries of message table | |
| INT unit1MsgIndex | 1.3.6.1.4.1.2606.4.2.3.7.2.1.1 | INTEGER | read-only | Index for the list of message entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfMsgs. |
| STR unit1MsgText | 1.3.6.1.4.1.2606.4.2.3.7.2.1.2 | DisplayString | read-write | Descriptional text for each message (entry in the table) |
| INT unit1MsgStatus | 1.3.6.1.4.1.2606.4.2.3.7.2.1.3 | INTEGER | read-only | Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber |
| INT unit1MsgRelay | 1.3.6.1.4.1.2606.4.2.3.7.2.1.4 | INTEGER | read-write | Setup of Alarm relay for this message/alarm 1: no switching of alarm relay 2: switching of alarm relay |
| INT unit1MsgBeeper | 1.3.6.1.4.1.2606.4.2.3.7.2.1.5 | INTEGER | read-write | Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm |
| INT unit1MsgTrap1 | 1.3.6.1.4.1.2606.4.2.3.7.2.1.6 | INTEGER | read-write | Trap receiver 1 activated |
| INT unit1MsgTrap2 | 1.3.6.1.4.1.2606.4.2.3.7.2.1.7 | INTEGER | read-write | Trap receiver 2 activated |
| INT unit1MsgTrap3 | 1.3.6.1.4.1.2606.4.2.3.7.2.1.8 | INTEGER | read-write | Trap receiver 3 activated |
| INT unit1MsgTrap4 | 1.3.6.1.4.1.2606.4.2.3.7.2.1.9 | INTEGER | read-write | Trap receiver 4 and Event Logging activated |
| INT unit1MsgQuit | 1.3.6.1.4.1.2606.4.2.3.7.2.1.10 | INTEGER | read-write | Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key |
| cmcTcStatusSensorUnit2 | 1.3.6.1.4.1.2606.4.2.4 | |||
| INT cmcTcUnit2TypeOfDevice | 1.3.6.1.4.1.2606.4.2.4.1 | INTEGER | read-only | Type of sensor unit connected to port 2 |
| STR cmcTcUnit2Text | 1.3.6.1.4.1.2606.4.2.4.2 | DisplayString | read-write | Descriptional text for sensor unit connected to port 2 |
| INT cmcTcUnit2Serial | 1.3.6.1.4.1.2606.4.2.4.3 | INTEGER | read-only | Serialnumber of sensor unit connected to port 2 |
| INT cmcTcUnit2Status | 1.3.6.1.4.1.2606.4.2.4.4 | INTEGER | read-only | General Status sensor unit connected to port 2 (1) OK (2) error (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required (6) sensor unit detected, needs to be confirmed (8) supply voltage is too low |
| cmcTcStatusUnit2Sensors | 1.3.6.1.4.1.2606.4.2.4.5 | |||
| INT cmcTcUnit2NumberOfSensors | 1.3.6.1.4.1.2606.4.2.4.5.1 | INTEGER | read-only | Number of sensors connected to sensor unit 2 |
| cmcTcUnit2SensorTable | 1.3.6.1.4.1.2606.4.2.4.5.2 | not-accessible | Headline of sensor table | |
| cmcTcUnit2SensorEntry | 1.3.6.1.4.1.2606.4.2.4.5.2.1 | not-accessible | Entries of sensor table | |
| INT unit2SensorIndex | 1.3.6.1.4.1.2606.4.2.4.5.2.1.1 | INTEGER | read-only | Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfSensors. |
| INT unit2SensorType | 1.3.6.1.4.1.2606.4.2.4.5.2.1.2 | INTEGER | read-only | Type of sensor which is connected to sensor unit 2 to sensor[unit2SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit |
| STR unit2SensorText | 1.3.6.1.4.1.2606.4.2.4.5.2.1.3 | DisplayString | read-write | Descriptional text for each sensor (entry in the table) |
| INT unit2SensorStatus | 1.3.6.1.4.1.2606.4.2.4.5.2.1.4 | INTEGER | read-only | Actual status of the sensor |
| INT unit2SensorValue | 1.3.6.1.4.1.2606.4.2.4.5.2.1.5 | INTEGER | read-only | Value of sensor |
| INT unit2SensorSetHigh | 1.3.6.1.4.1.2606.4.2.4.5.2.1.6 | INTEGER | read-write | Value for high setpoint of sensor |
| INT unit2SensorSetLow | 1.3.6.1.4.1.2606.4.2.4.5.2.1.7 | INTEGER | read-write | Value for low setpoint of sensor, also used as alarm delay |
| INT unit2SensorSetWarn | 1.3.6.1.4.1.2606.4.2.4.5.2.1.8 | INTEGER | read-write | Value for warning setpoint of sensor, also used as fan threshold |
| cmcTcStatusUnit2Outputs | 1.3.6.1.4.1.2606.4.2.4.6 | |||
| INT cmcTcUnit2NumberOfOutputs | 1.3.6.1.4.1.2606.4.2.4.6.1 | INTEGER | read-only | Number of outputs available on sensor unit 2 |
| cmcTcUnit2OutputTable | 1.3.6.1.4.1.2606.4.2.4.6.2 | not-accessible | Headline of output table | |
| cmcTcUnit2OutputEntry | 1.3.6.1.4.1.2606.4.2.4.6.2.1 | not-accessible | Entries of output table | |
| INT unit2OutputIndex | 1.3.6.1.4.1.2606.4.2.4.6.2.1.1 | INTEGER | read-only | Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfOutputs. |
| INT unit2OutputType | 1.3.6.1.4.1.2606.4.2.4.6.2.1.2 | INTEGER | read-only | Type of output which is connected to sensor unit 2 to output[unit2OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) |
| STR unit2OutputText | 1.3.6.1.4.1.2606.4.2.4.6.2.1.3 | DisplayString | read-write | Descriptional text for each output (entry in the table) |
| INT unit2OutputStatus | 1.3.6.1.4.1.2606.4.2.4.6.2.1.4 | INTEGER | read-write | Actual status of the output |
| INT unit2OutputValue | 1.3.6.1.4.1.2606.4.2.4.6.2.1.5 | INTEGER | read-write | Signed value for output |
| INT unit2OutputSet | 1.3.6.1.4.1.2606.4.2.4.6.2.1.6 | INTEGER | read-write | Command for output |
| INT unit2OutputConfig | 1.3.6.1.4.1.2606.4.2.4.6.2.1.7 | INTEGER | read-write | Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control |
| INT unit2OutputDelay | 1.3.6.1.4.1.2606.4.2.4.6.2.1.8 | INTEGER | read-write | Unsigned Value for delay, after this time the output will fall into the previous state |
| INT unit2OutputTimeoutAction | 1.3.6.1.4.1.2606.4.2.4.6.2.1.9 | INTEGER | read-write | State for output if timeout (RS422) occurs |
| cmcTcStatusUnit2Msg | 1.3.6.1.4.1.2606.4.2.4.7 | |||
| INT cmcTcUnit2NumberOfMsgs | 1.3.6.1.4.1.2606.4.2.4.7.1 | INTEGER | read-only | Number of alarms that can be created with sensor unit 2 |
| cmcTcUnit2MsgTable | 1.3.6.1.4.1.2606.4.2.4.7.2 | not-accessible | Headline of message table | |
| cmcTcUnit2MsgEntry | 1.3.6.1.4.1.2606.4.2.4.7.2.1 | not-accessible | Entries of message table | |
| INT unit2MsgIndex | 1.3.6.1.4.1.2606.4.2.4.7.2.1.1 | INTEGER | read-only | Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfMsgs. |
| STR unit2MsgText | 1.3.6.1.4.1.2606.4.2.4.7.2.1.2 | DisplayString | read-write | Descriptional text for each message (entry in the table) |
| INT unit2MsgStatus | 1.3.6.1.4.1.2606.4.2.4.7.2.1.3 | INTEGER | read-only | Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber |
| INT unit2MsgRelay | 1.3.6.1.4.1.2606.4.2.4.7.2.1.4 | INTEGER | read-write | Setup of Alarm relay for this alarm 2: no switching of alarm relay 1: switching of alarm relay |
| INT unit2MsgBeeper | 1.3.6.1.4.1.2606.4.2.4.7.2.1.5 | INTEGER | read-write | Setup of Alarm beeper for this alarm 2: no audible alarm 1: audible alarm |
| INT unit2MsgTrap1 | 1.3.6.1.4.1.2606.4.2.4.7.2.1.6 | INTEGER | read-write | Trap receiver 1 activated |
| INT unit2MsgTrap2 | 1.3.6.1.4.1.2606.4.2.4.7.2.1.7 | INTEGER | read-write | Trap receiver 2 activated |
| INT unit2MsgTrap3 | 1.3.6.1.4.1.2606.4.2.4.7.2.1.8 | INTEGER | read-write | Trap receiver 3 activated |
| INT unit2MsgTrap4 | 1.3.6.1.4.1.2606.4.2.4.7.2.1.9 | INTEGER | read-write | Trap receiver 4 and Event Logging activated |
| INT unit2MsgQuit | 1.3.6.1.4.1.2606.4.2.4.7.2.1.10 | INTEGER | read-write | Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key |
| cmcTcStatusSensorUnit3 | 1.3.6.1.4.1.2606.4.2.5 | |||
| INT cmcTcUnit3TypeOfDevice | 1.3.6.1.4.1.2606.4.2.5.1 | INTEGER | read-only | Type of sensor unit connected to port 3 |
| STR cmcTcUnit3Text | 1.3.6.1.4.1.2606.4.2.5.2 | DisplayString | read-write | Descriptional text for sensor unit connected to port 3 |
| INT cmcTcUnit3Serial | 1.3.6.1.4.1.2606.4.2.5.3 | INTEGER | read-only | Serialnumber of sensor unit connected to port 3 |
| INT cmcTcUnit3Status | 1.3.6.1.4.1.2606.4.2.5.4 | INTEGER | read-only | General Status sensor unit connected to port 3 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low |
| cmcTcStatusUnit3Sensors | 1.3.6.1.4.1.2606.4.2.5.5 | |||
| INT cmcTcUnit3NumberOfSensors | 1.3.6.1.4.1.2606.4.2.5.5.1 | INTEGER | read-only | Number of sensors connected to sensor unit 3 |
| cmcTcUnit3SensorTable | 1.3.6.1.4.1.2606.4.2.5.5.2 | not-accessible | Headline of sensor table | |
| cmcTcUnit3SensorEntry | 1.3.6.1.4.1.2606.4.2.5.5.2.1 | not-accessible | Entries of sensor table | |
| INT unit3SensorIndex | 1.3.6.1.4.1.2606.4.2.5.5.2.1.1 | INTEGER | read-only | Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfSensors. |
| INT unit3SensorType | 1.3.6.1.4.1.2606.4.2.5.5.2.1.2 | INTEGER | read-only | Type of sensor which is connected to sensor unit 3 to sensor[unit3SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit |
| STR unit3SensorText | 1.3.6.1.4.1.2606.4.2.5.5.2.1.3 | DisplayString | read-write | Descriptional text for each sensor (entry in the table) |
| INT unit3SensorStatus | 1.3.6.1.4.1.2606.4.2.5.5.2.1.4 | INTEGER | read-only | Actual status of the sensor |
| INT unit3SensorValue | 1.3.6.1.4.1.2606.4.2.5.5.2.1.5 | INTEGER | read-only | Value of sensor |
| INT unit3SensorSetHigh | 1.3.6.1.4.1.2606.4.2.5.5.2.1.6 | INTEGER | read-write | Value for high setpoint of sensor |
| INT unit3SensorSetLow | 1.3.6.1.4.1.2606.4.2.5.5.2.1.7 | INTEGER | read-write | Value for low setpoint of sensor |
| INT unit3SensorSetWarn | 1.3.6.1.4.1.2606.4.2.5.5.2.1.8 | INTEGER | read-write | Value for warning setpoint of sensor, also used as fan threshold |
| cmcTcStatusUnit3Outputs | 1.3.6.1.4.1.2606.4.2.5.6 | |||
| INT cmcTcUnit3NumberOfOutputs | 1.3.6.1.4.1.2606.4.2.5.6.1 | INTEGER | read-only | Number of outputs available on sensor unit 3 |
| cmcTcUnit3OutputTable | 1.3.6.1.4.1.2606.4.2.5.6.2 | not-accessible | Headline of output table | |
| cmcTcUnit3OutputEntry | 1.3.6.1.4.1.2606.4.2.5.6.2.1 | not-accessible | Entries of output table | |
| INT unit3OutputIndex | 1.3.6.1.4.1.2606.4.2.5.6.2.1.1 | INTEGER | read-only | Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfOutputs. |
| INT unit3OutputType | 1.3.6.1.4.1.2606.4.2.5.6.2.1.2 | INTEGER | read-only | Type of output which is connected to sensor unit 3 to output[unit3OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) |
| STR unit3OutputText | 1.3.6.1.4.1.2606.4.2.5.6.2.1.3 | DisplayString | read-write | Descriptional text for each output (entry in the table) |
| INT unit3OutputStatus | 1.3.6.1.4.1.2606.4.2.5.6.2.1.4 | INTEGER | read-write | Actual status of the output |
| INT unit3OutputValue | 1.3.6.1.4.1.2606.4.2.5.6.2.1.5 | INTEGER | read-write | Value for output |
| INT unit3OutputSet | 1.3.6.1.4.1.2606.4.2.5.6.2.1.6 | INTEGER | read-write | Command for output |
| INT unit3OutputConfig | 1.3.6.1.4.1.2606.4.2.5.6.2.1.7 | INTEGER | read-write | Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control |
| INT unit3OutputDelay | 1.3.6.1.4.1.2606.4.2.5.6.2.1.8 | INTEGER | read-write | Unsigned Value for delay, after this time the output will fall into the previous state |
| INT unit3OutputTimeoutAction | 1.3.6.1.4.1.2606.4.2.5.6.2.1.9 | INTEGER | read-write | State for output if timeout (RS422) occurs |
| cmcTcStatusUnit3Msg | 1.3.6.1.4.1.2606.4.2.5.7 | |||
| INT cmcTcUnit3NumberOfMsgs | 1.3.6.1.4.1.2606.4.2.5.7.1 | INTEGER | read-only | Number of alarms that can be created with sensor unit 3 |
| cmcTcUnit3MsgTable | 1.3.6.1.4.1.2606.4.2.5.7.2 | not-accessible | Headline of message table | |
| cmcTcUnit3MsgEntry | 1.3.6.1.4.1.2606.4.2.5.7.2.1 | not-accessible | Entries of message table | |
| INT unit3MsgIndex | 1.3.6.1.4.1.2606.4.2.5.7.2.1.1 | INTEGER | read-only | Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfMsgs. |
| STR unit3MsgText | 1.3.6.1.4.1.2606.4.2.5.7.2.1.2 | DisplayString | read-write | Descriptional text for each message (entry in the table) |
| INT unit3MsgStatus | 1.3.6.1.4.1.2606.4.2.5.7.2.1.3 | INTEGER | read-only | Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber |
| INT unit3MsgRelay | 1.3.6.1.4.1.2606.4.2.5.7.2.1.4 | INTEGER | read-write | Setup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relay |
| INT unit3MsgBeeper | 1.3.6.1.4.1.2606.4.2.5.7.2.1.5 | INTEGER | read-write | Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm |
| INT unit3MsgTrap1 | 1.3.6.1.4.1.2606.4.2.5.7.2.1.6 | INTEGER | read-write | Trap receiver 1 activated |
| INT unit3MsgTrap2 | 1.3.6.1.4.1.2606.4.2.5.7.2.1.7 | INTEGER | read-write | Trap receiver 2 activated |
| INT unit3MsgTrap3 | 1.3.6.1.4.1.2606.4.2.5.7.2.1.8 | INTEGER | read-write | Trap receiver 3 activated |
| INT unit3MsgTrap4 | 1.3.6.1.4.1.2606.4.2.5.7.2.1.9 | INTEGER | read-write | Trap receiver 4 and Event Logging activated |
| INT unit3MsgQuit | 1.3.6.1.4.1.2606.4.2.5.7.2.1.10 | INTEGER | read-write | Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key |
| cmcTcStatusSensorUnit4 | 1.3.6.1.4.1.2606.4.2.6 | |||
| INT cmcTcUnit4TypeOfDevice | 1.3.6.1.4.1.2606.4.2.6.1 | INTEGER | read-only | Type of sensor unit connected to port 4 |
| STR cmcTcUnit4Text | 1.3.6.1.4.1.2606.4.2.6.2 | DisplayString | read-write | Descriptional text for sensor unit connected to port 4 |
| INT cmcTcUnit4Serial | 1.3.6.1.4.1.2606.4.2.6.3 | INTEGER | read-only | Serialnumber of sensor unit connected to port 4 |
| INT cmcTcUnit4Status | 1.3.6.1.4.1.2606.4.2.6.4 | INTEGER | read-only | General Status sensor unit connected to port 4 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low |
| cmcTcStatusUnit4Sensors | 1.3.6.1.4.1.2606.4.2.6.5 | |||
| INT cmcTcUnit4NumberOfSensors | 1.3.6.1.4.1.2606.4.2.6.5.1 | INTEGER | read-only | Number of sensors connected to sensor unit 4 |
| cmcTcUnit4SensorTable | 1.3.6.1.4.1.2606.4.2.6.5.2 | not-accessible | Headline of sensor table | |
| cmcTcUnit4SensorEntry | 1.3.6.1.4.1.2606.4.2.6.5.2.1 | not-accessible | Entries of sensor table | |
| INT unit4SensorIndex | 1.3.6.1.4.1.2606.4.2.6.5.2.1.1 | INTEGER | read-only | Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfSensors. |
| INT unit4SensorType | 1.3.6.1.4.1.2606.4.2.6.5.2.1.2 | INTEGER | read-only | Type of sensor which is connected to sensor unit 4 to sensor[unit4SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit |
| STR unit4SensorText | 1.3.6.1.4.1.2606.4.2.6.5.2.1.3 | DisplayString | read-write | Descriptional text for each sensor (entry in the table) |
| INT unit4SensorStatus | 1.3.6.1.4.1.2606.4.2.6.5.2.1.4 | INTEGER | read-only | Actual status of the sensor |
| INT unit4SensorValue | 1.3.6.1.4.1.2606.4.2.6.5.2.1.5 | INTEGER | read-only | Value of sensor |
| INT unit4SensorSetHigh | 1.3.6.1.4.1.2606.4.2.6.5.2.1.6 | INTEGER | read-write | Value for high setpoint of sensor |
| INT unit4SensorSetLow | 1.3.6.1.4.1.2606.4.2.6.5.2.1.7 | INTEGER | read-write | Value for low setpoint of sensor |
| INT unit4SensorSetWarn | 1.3.6.1.4.1.2606.4.2.6.5.2.1.8 | INTEGER | read-write | Value for warning setpoint of sensor, also used as fan threshold |
| cmcTcStatusUnit4Outputs | 1.3.6.1.4.1.2606.4.2.6.6 | |||
| INT cmcTcUnit4NumberOfOutputs | 1.3.6.1.4.1.2606.4.2.6.6.1 | INTEGER | read-only | Number of outputs available on sensor unit 4 |
| cmcTcUnit4OutputTable | 1.3.6.1.4.1.2606.4.2.6.6.2 | not-accessible | Headline of output table | |
| cmcTcUnit4OutputEntry | 1.3.6.1.4.1.2606.4.2.6.6.2.1 | not-accessible | Entries of output table | |
| INT unit4OutputIndex | 1.3.6.1.4.1.2606.4.2.6.6.2.1.1 | INTEGER | read-only | Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfOutputs. |
| INT unit4OutputType | 1.3.6.1.4.1.2606.4.2.6.6.2.1.2 | INTEGER | read-only | Type of output which is connected to sensor unit 4 to output[unit4OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) |
| STR unit4OutputText | 1.3.6.1.4.1.2606.4.2.6.6.2.1.3 | DisplayString | read-write | Descriptional text for each output (entry in the table) |
| INT unit4OutputStatus | 1.3.6.1.4.1.2606.4.2.6.6.2.1.4 | INTEGER | read-write | Actual status of the output |
| INT unit4OutputValue | 1.3.6.1.4.1.2606.4.2.6.6.2.1.5 | INTEGER | read-write | Value for output |
| INT unit4OutputSet | 1.3.6.1.4.1.2606.4.2.6.6.2.1.6 | INTEGER | read-write | Command for output |
| INT unit4OutputConfig | 1.3.6.1.4.1.2606.4.2.6.6.2.1.7 | INTEGER | read-write | Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control |
| INT unit4OutputDelay | 1.3.6.1.4.1.2606.4.2.6.6.2.1.8 | INTEGER | read-write | Unsigned Value for delay, after this time the output will fall into the previous state |
| INT unit4OutputTimeoutAction | 1.3.6.1.4.1.2606.4.2.6.6.2.1.9 | INTEGER | read-write | State for output if timeout (RS422) occurs |
| cmcTcStatusUnit4Msg | 1.3.6.1.4.1.2606.4.2.6.7 | |||
| INT cmcTcUnit4NumberOfMsgs | 1.3.6.1.4.1.2606.4.2.6.7.1 | INTEGER | read-only | Number of alarms that can be created with sensor unit 4 |
| cmcTcUnit4MsgTable | 1.3.6.1.4.1.2606.4.2.6.7.2 | not-accessible | Headline of message table | |
| cmcTcUnit4MsgEntry | 1.3.6.1.4.1.2606.4.2.6.7.2.1 | not-accessible | Entries of message table | |
| INT unit4MsgIndex | 1.3.6.1.4.1.2606.4.2.6.7.2.1.1 | INTEGER | read-only | Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfMsgs. |
| STR unit4MsgText | 1.3.6.1.4.1.2606.4.2.6.7.2.1.2 | DisplayString | read-write | Descriptional text for each message (entry in the table) |
| INT unit4MsgStatus | 1.3.6.1.4.1.2606.4.2.6.7.2.1.3 | INTEGER | read-only | Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber |
| INT unit4MsgRelay | 1.3.6.1.4.1.2606.4.2.6.7.2.1.4 | INTEGER | read-write | Setup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relay |
| INT unit4MsgBeeper | 1.3.6.1.4.1.2606.4.2.6.7.2.1.5 | INTEGER | read-write | Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm |
| INT unit4MsgTrap1 | 1.3.6.1.4.1.2606.4.2.6.7.2.1.6 | INTEGER | read-write | Trap receiver 1 activated |
| INT unit4MsgTrap2 | 1.3.6.1.4.1.2606.4.2.6.7.2.1.7 | INTEGER | read-write | Trap receiver 2 activated |
| INT unit4MsgTrap3 | 1.3.6.1.4.1.2606.4.2.6.7.2.1.8 | INTEGER | read-write | Trap receiver 3 activated |
| INT unit4MsgTrap4 | 1.3.6.1.4.1.2606.4.2.6.7.2.1.9 | INTEGER | read-write | Trap receiver 4 and Event Logging activated |
| INT unit4MsgQuit | 1.3.6.1.4.1.2606.4.2.6.7.2.1.10 | INTEGER | read-write | Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key |
| cmcTcStatusExtUnit | 1.3.6.1.4.1.2606.4.2.7 | |||
| INT cmcTcValuesRelay | 1.3.6.1.4.1.2606.4.2.7.1 | INTEGER | read-write | Setup of Alarm relay for alarm ext. unit(s) 1: no switching of alarm relay 2: switching of alarm relay |
| INT cmcTcValuesBeeper | 1.3.6.1.4.1.2606.4.2.7.2 | INTEGER | read-write | Setup of Alarm beeper for alarm ext. unit(s) 1: no audible alarm 2: audible alarm |
| INT cmcTcValuesTrap1 | 1.3.6.1.4.1.2606.4.2.7.3 | INTEGER | read-write | Trap receiver 1 activated |
| INT cmcTcValuesTrap2 | 1.3.6.1.4.1.2606.4.2.7.4 | INTEGER | read-write | Trap receiver 2 activated |
| INT cmcTcValuesTrap3 | 1.3.6.1.4.1.2606.4.2.7.5 | INTEGER | read-write | Trap receiver 3 activated |
| INT cmcTcValuesTrap4 | 1.3.6.1.4.1.2606.4.2.7.6 | INTEGER | read-write | Trap receiver 4 and Event Logging activated |
| INT cmcTcNumberOfValues | 1.3.6.1.4.1.2606.4.2.7.7 | INTEGER | read-only | Number of values availabel on extension units connected to the CMC |
| cmcTcValuesTable | 1.3.6.1.4.1.2606.4.2.7.8 | not-accessible | Headline of values-table | |
| cmcTcValuesEntry | 1.3.6.1.4.1.2606.4.2.7.8.1 | not-accessible | Entries of values-table | |
| INT valuesIndex | 1.3.6.1.4.1.2606.4.2.7.8.1.1 | INTEGER | read-only | Index for the list of value entries. Its value ranges between 1 and the value of cmcTcNumberOfValues. |
| STR valuesText | 1.3.6.1.4.1.2606.4.2.7.8.1.2 | DisplayString | read-write | Descriptional text for each value (entry in the table) of the extension card |
| INT valuesStatus | 1.3.6.1.4.1.2606.4.2.7.8.1.3 | INTEGER | read-only | Actual status of the value of the extension card |
| INT valuesValue | 1.3.6.1.4.1.2606.4.2.7.8.1.4 | INTEGER | read-only | Value of sensor |
| INT valuesSetHigh | 1.3.6.1.4.1.2606.4.2.7.8.1.5 | INTEGER | read-write | Value for high setpoint of sensor |
| INT valuesSetLow | 1.3.6.1.4.1.2606.4.2.7.8.1.6 | INTEGER | read-write | Value for low setpoint of sensor |
| cmcTcSetup | 1.3.6.1.4.1.2606.4.3 | |||
| cmcTcSetupGeneral | 1.3.6.1.4.1.2606.4.3.1 | |||
| INT cmcTcSetTempUnit | 1.3.6.1.4.1.2606.4.3.1.1 | INTEGER | read-write | Unit of all temperature values and setpoints, Celsius or Fahrenheit |
| INT cmcTcSetBeeper | 1.3.6.1.4.1.2606.4.3.1.2 | INTEGER | read-write | Audible alarm in CMC-TC unit: (2): beeper is on (1): beeper is off (general) |
| INT cmcTcQuitRelay | 1.3.6.1.4.1.2606.4.3.1.3 | INTEGER | read-write | Enable or disable acknowledging currently active alarm relay (with 'C' on CMC-TC). |
| INT cmcTcLogicRelay | 1.3.6.1.4.1.2606.4.3.1.4 | INTEGER | read-write | Logic of alarm relay: (1) Relay will pick up in case of an alarm (2) Relay will release in case of an alarm (3) Relay off (general) |
| INT cmcTcWebAccess | 1.3.6.1.4.1.2606.4.3.1.5 | INTEGER | read-write | Web access via HTTP: (1) view only (2) full Access, read and set (3) Web disabled (general) |
| STR cmcTcSetupDate | 1.3.6.1.4.1.2606.4.3.1.6 | DisplayString | read-write | actual Date in format DD.MM.YYYY |
| STR cmcTcSetupTime | 1.3.6.1.4.1.2606.4.3.1.7 | DisplayString | read-write | actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59) |
| cmcTcTimerTable1 | 1.3.6.1.4.1.2606.4.3.1.8 | |||
| INT cmcTcTimerNumber | 1.3.6.1.4.1.2606.4.3.1.8.1 | INTEGER | read-only | Number of value-table entries=number of outlets available on this unit |
| cmcTcTimerTable | 1.3.6.1.4.1.2606.4.3.1.8.2 | not-accessible | Headline of status-table | |
| cmcTcTimerEntry | 1.3.6.1.4.1.2606.4.3.1.8.2.1 | not-accessible | Entries of timer-table | |
| INT cmcTcTimerIndex | 1.3.6.1.4.1.2606.4.3.1.8.2.1.1 | INTEGER | read-only | Index for the list of timer entries. Its value ranges between 1 and the value of cmcTcTimerNumber. |
| INT cmcTcTimerStatus | 1.3.6.1.4.1.2606.4.3.1.8.2.1.2 | INTEGER | read-only | Actual status of the timer |
| INT cmcTcTimerDayOfWeek | 1.3.6.1.4.1.2606.4.3.1.8.2.1.3 | INTEGER | read-write | Selection of day of week for timer to switch |
| STR cmcTcTimeOn | 1.3.6.1.4.1.2606.4.3.1.8.2.1.4 | DisplayString | read-write | Time to switch on current function, Format: HH:MM |
| STR cmcTcTimeOff | 1.3.6.1.4.1.2606.4.3.1.8.2.1.5 | DisplayString | read-write | Time to switch off current function, Format: HH:MM |
| INT cmcTcTimeControl | 1.3.6.1.4.1.2606.4.3.1.8.2.1.6 | INTEGER | read-write | Control via RTC |
| INT cmcTcTimerFunction | 1.3.6.1.4.1.2606.4.3.1.8.2.1.7 | INTEGER | read-write | Function which is controlled via timer 1: unlock via keypad 1 on unit 1 or remote input lock 1 is disabled 2: unlock via keypad 2 on unit 1 or remote input lock 2 is disabled 3 unlock via keypad 1 on unit 2 or remote input lock 1 is disabled 4: unlock via keypad 2 on unit 2 or remote input lock 2 is disabled 5: unlock via keypad 1 on unit 3 or remote input lock 1 is disabled 6: unlock via keypad 2 on unit 3 or remote input lock 2 is disabled 7: unlock via keypad 1 on unit 4 or remote input lock 1 is disabled 8: unlock via keypad 2 on unit 4 or remote input lock 2 is disabled 9: Lock of door 1 on unit 1 will be unlocked 10: Lock of door 2 on unit 1 will be unlocked 11: Lock of door 1 on unit 2 will be unlocked 12: Lock of door 2 on unit 2 will be unlocked 13: Lock of door 1 on unit 3 will be unlocked 14: Lock of door 2 on unit 3 will be unlocked 15: Lock of door 1 on unit 4 will be unlocked 16: Lock of door 2 on unit 4 will be unlocked 17-20: sending Traps to this Trap receiver will be disabled |
| cmcTcTrapControl | 1.3.6.1.4.1.2606.4.4 | |||
| cmcTcTraps | 1.3.6.1.4.1.2606.4.4.7 | |||
| INT cmcTcTraptableNumber | 1.3.6.1.4.1.2606.4.4.7.1 | INTEGER | read-only | Number of trapTable entries. The number of trap-receiver |
| cmcTcTrapTableTable | 1.3.6.1.4.1.2606.4.4.7.2 | not-accessible | A list of trap-receiver entries | |
| cmcTcTrapTableEntry | 1.3.6.1.4.1.2606.4.4.7.2.1 | not-accessible | Entries of trapTable | |
| INT trapIndex | 1.3.6.1.4.1.2606.4.4.7.2.1.1 | INTEGER | read-only | Index for the trap-receiver-table. Its value ranges between 1 and the value of traptableNumber |
| INT trapStatus | 1.3.6.1.4.1.2606.4.4.7.2.1.2 | INTEGER | read-write | Enable or disable trap receiver |
| STR trapIPaddress | 1.3.6.1.4.1.2606.4.4.7.2.1.3 | DisplayString | read-write | IP-address of trap-receiver |
| cmcTcControl | 1.3.6.1.4.1.2606.4.5 | |||
| INT cmcTcQuitUnit | 1.3.6.1.4.1.2606.4.5.1 | INTEGER | read-write | Command to quit (acknowledge) alarms of CMC-TC unit. Setting to 'quit' (2) will have same result as pressing 'C' on Units. Variable is automatically set back to 'noQuit' (1). |
RFC description
RITTAL CMC-TC facility management monitoring sensors, outputs, and environmental conditions.
Start monitoring Rittal CMC (Computer Multi Control) rack environmental monitoring unit (shared textual conventions) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.