RAPID-CITY :: rcPlugOptModAux1HighAlarmThreshold

MIB Reference — IPNetwork Monitor

All MIBsRAPID-CITYrcPlugOptModAux1HighAlarmThreshold

rcPlugOptModAux1HighAlarmThreshold

Module: RAPID-CITY

OID (symbolic): RAPID-CITY::rcPlugOptModAux1HighAlarmThreshold

OID (numeric): 1.3.6.1.4.1.2272.1.71.1.1.43

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description:

This value represents the vendor specified high Aux1 threshold.

What is rcPlugOptModAux1HighAlarmThreshold?

This OID stores the vendor-specified alarm threshold for an auxiliary monitoring channel on an optical module. It tells you the maximum safe value before the system raises a high alarm. A field technician would reference this during hardware diagnostics to determine if an environmental reading is within acceptable operating limits.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2272.1.71.1.1.43
snmpwalk -v2c -c public <target> RAPID-CITY::rcPlugOptModAux1HighAlarmThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2272.1.71.1.1.43.1
snmpget -v2c -c public <target> RAPID-CITY::rcPlugOptModAux1HighAlarmThreshold.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> rcPlugOptModAux1HighAlarmThreshold.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.2272rapidCityRAPID-CITY
1.3.6.1.4.1.2272.1rcMgmtRAPID-CITY
1.3.6.1.4.1.2272.1.71rcPlugOptModRAPID-CITY
1.3.6.1.4.1.2272.1.71.1rcPlugOptModTableRAPID-CITY
1.3.6.1.4.1.2272.1.71.1.1rcPlugOptModEntryRAPID-CITY
1.3.6.1.4.1.2272.1.71.1.1.43rcPlugOptModAux1HighAlarmThresholdRAPID-CITY