| OID symbolic | OID numeric | Type | Access | Description |
| protection | 1.3.6.1.4.1.1038.130 | | | This MIB describe protection mechanisms used by SDH equipment |
| msp | 1.3.6.1.4.1.1038.130.10 | | | |
| INT mspNumber | 1.3.6.1.4.1.1038.130.10.1 | INTEGER | read-only | Number of multiplex section protection in equipment. |
| mspTable | 1.3.6.1.4.1.1038.130.10.2 | | not-accessible | List of multiplex section protection in equipment. |
| mspEntry | 1.3.6.1.4.1.1038.130.10.2.1 | | not-accessible | A particular multiplex section protection of the equipment.
Each entry is created in using the msTTPTable of the Sdh-Ets MIB. |
| INT mspIndex | 1.3.6.1.4.1.1038.130.10.2.1.1 | INTEGER | read-only | A unique value which identify a particular multiplex section protection.
This index is equal to an msTTPIndex(=spiIndex) which gives the interface involved .
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware. |
| INT mspWorkingPointer | 1.3.6.1.4.1.1038.130.10.2.1.2 | INTEGER | read-only | A reference to the object which sends the data flow to this
function on working synchronous port interface side.
In most equipments, this value cannot be changed and points to
the working MST it is hard wired with. |
| INT mspProtectionPointer | 1.3.6.1.4.1.1038.130.10.2.1.3 | INTEGER | read-write | A reference to the object which sends the data flow to this
function on protection synchronous port interface side.
In most equipments, this value cannot be changed and points to
the protection MST it is hard wired with.
When this variable is setting, the protection is created and activated (if it's possible).
The two considerated sections must have the same Stm Level. |
| MSP mspType | 1.3.6.1.4.1.1038.130.10.2.1.4 | MspType | read-write | Indication of the protection type. |
| MSP mspDir | 1.3.6.1.4.1.1038.130.10.2.1.5 | MspDirection | read-write | Indication of the direction. |
| TRA mspTraffic | 1.3.6.1.4.1.1038.130.10.2.1.6 | TrafficStatus | read-only | The value of this field indicates the protection switch position. |
| SAG mspRevertive | 1.3.6.1.4.1.1038.130.10.2.1.7 | SagemBoolean | read-write | If the value is true the msp function is allowed to spontaneously
switch back to working chanel when it is available.
If not, the msp can switch back to working chanel only if
protection chanel fails. |
| INT mspWtr | 1.3.6.1.4.1.1038.130.10.2.1.8 | INTEGER | read-write | The time (in seconds) the msp function waits before
considering a chanel as good after a fail. |
| MSP mspSfSdPriority | 1.3.6.1.4.1.1038.130.10.2.1.9 | MspPriority | read-write | Signal Fail and Signal Degrade can be treated according to two set
of priority. The equipement will send SF and SD events according to
the value of this field. |
| INT mspSfSdHoldOffTime | 1.3.6.1.4.1.1038.130.10.2.1.10 | INTEGER | read-write | The period (in tenth of seconds) during which a
sf or a Signal Degrade is
ignored by the MSP switch. |
| MSP mspCommand | 1.3.6.1.4.1.1038.130.10.2.1.11 | MspCommand | read-write | Manual or forced commands can be apply to the protection switch.
The forced and manual switch can be refused or cleared by equipment
if a higher priority APS command is received or if the protection chanel
is down.
When this field is set to manual or forced, the mspTraffic field
becomes read-write, and a set can be issued to specifie on which
chanel the command does apply.
Commands:
LP (Lockout of Protection)
LW (Lockout of Working channel)
FSW (Forced Switch of a Working channel to protection)
FSP (Forced Switch of a Protection channel to working) case 1+1
MSW (Manual Switch of a Working channel to protection)
MSp (Manual Switch of a Protection channel to working) case 1+1
EXER (EXERcise) |
| MSP mspInitiator | 1.3.6.1.4.1.1038.130.10.2.1.12 | MspInitiator | read-only | Indicates the initiator equipment. |
| MSP mspStatus | 1.3.6.1.4.1.1038.130.10.2.1.13 | MspStatus | read-only | Indicates the initiator equipment status :
lockoutProtection(15),
forcedSwitch(14),
highSF(13),
lowSF(12),
highSD(11),
lowSD(10),
manualSwitch(8),
waitToRestore(6),
exercise(4),
reverseRequest(2),
doNotRevert(1),
noRequest(0) |
| SAG mspMonitor | 1.3.6.1.4.1.1038.130.10.2.1.14 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection
is stopped for this multiplex section protection. |
| MSP mspFailure | 1.3.6.1.4.1.1038.130.10.2.1.15 | MspFailure | read-only | Active failures on multiplex section protection. |
| SEV mspSeverity | 1.3.6.1.4.1.1038.130.10.2.1.16 | Severity | read-only | A reference to failure severity for multiplex section protection. |
| SEV mspPam | 1.3.6.1.4.1.1038.130.10.2.1.20 | Severity | read-write | Severity associed with Protection Architecture Mismatch failure
for multiplex section protection. |
| SEV mspScm | 1.3.6.1.4.1.1038.130.10.2.1.21 | Severity | read-write | Severity associed with Selector Control Mismatch failure
for multiplex section protection. |
| SEV mspOtm | 1.3.6.1.4.1.1038.130.10.2.1.22 | Severity | read-write | Severity associed with Operation Type Mismatch failure
for multiplex section protection. |
| msSPRing | 1.3.6.1.4.1.1038.130.20 | | | |
| INT msSPRingNumber | 1.3.6.1.4.1.1038.130.20.1 | INTEGER | read-only | Number of multiplex section protection in equipment. |
| msSPRingTable | 1.3.6.1.4.1.1038.130.20.6 | | not-accessible | List of multiplex section protection in equipment. |
| msSPRingEntry | 1.3.6.1.4.1.1038.130.20.6.1 | | not-accessible | A particular multiplex section protection of the equipment.
Each entry is created in using the msTTPTable of the Sdh-Ets MIB.
spiIndex gives the interface involved (line east or west) |
| INT msSPRingIndex | 1.3.6.1.4.1.1038.130.20.6.1.1 | INTEGER | read-only | A unique value which identify a particular SPRing = West STM index. |
| INT msSPRingWestPointer | 1.3.6.1.4.1.1038.130.20.6.1.2 | INTEGER | read-only | A reference to the object which sends the data flow to this
function on synchronous port interface side.
In most equipments, this value cannot be changed and points to
the West MST it is hard wired with. |
| INT msSPRingEastPointer | 1.3.6.1.4.1.1038.130.20.6.1.3 | INTEGER | read-write | A reference to the object which sends the data flow to this
function on synchronous port interface side.
In most equipments, this value cannot be changed and points to
the East MST it is hard wired with.
When this variable is setting, the protection is created and activated (if it's possible).
The two considerated sections must have the same Stm Level. |
| INT msSPRingWtr | 1.3.6.1.4.1.1038.130.20.6.1.5 | INTEGER | read-write | The time (in seconds) the spring function waits before
considering a chanel as good after a fail. |
| INT msSPRingSfSdHoldOffTime | 1.3.6.1.4.1.1038.130.20.6.1.6 | INTEGER | read-write | The period (in tenth of seconds) during which a
sf or a Signal Degrade is ignored by the SPRing switch. |
| INT msSPRingCommandSide | 1.3.6.1.4.1.1038.130.20.6.1.7 | INTEGER | read-write | Side of the command |
| MSS msSPRingCommand | 1.3.6.1.4.1.1038.130.20.6.1.8 | MsSPRingCommand | read-write | Manual or forced commands can be apply to the protection switch. |
| MSS msSPRingInitiator1 | 1.3.6.1.4.1.1038.130.20.6.1.10 | MsSPRingID | read-only | A reference(ID) to the equipment that initiate the SWITCH; this is mainly the Master
when the equipment is in SWITCH state; in some case like bidirectional SF both equipment
of the couple equipment are Master.
In PASS state Master and Slave are undeterminated |
| MSS msSPRingInitiator2 | 1.3.6.1.4.1.1038.130.20.6.1.11 | MsSPRingID | read-only | A reference(ID) to the equipment that respond to the SWITCH; this is mainly the Slave
when the equipment is in SWITCH state; in some case like bidirectional SF both equipment
of the couple equipment are Master.
In PASS state Master and Slave are undeterminated |
| SAG msSPRingMonitor | 1.3.6.1.4.1.1038.130.20.6.1.12 | SagemBoolean | read-write | When the value of this field is set to false, the failure detection
is stopped for this multiplex section protection. |
| MSS msSPRingFailure | 1.3.6.1.4.1.1038.130.20.6.1.13 | MsSPRingFailure | read-only | Active failures on multiplex section protection |
| SEV msSPRingSeverity | 1.3.6.1.4.1.1038.130.20.6.1.14 | Severity | read-only | A reference to failure severity for multiplex section protection. |
| SEV msSPRingAto | 1.3.6.1.4.1.1038.130.20.6.1.21 | Severity | read-write | Severity associed with APS Time Out failure failure
for MS-SPRing. |
| SEV msSPRingArv | 1.3.6.1.4.1.1038.130.20.6.1.22 | Severity | read-write | Severity associed with APS Rules Violation failure failure
for MS-SPRing. |
| SEV msSPRingAun | 1.3.6.1.4.1.1038.130.20.6.1.23 | Severity | read-write | Severity associed with APS Unknown Node failure failure
for MS-SPRing. |
| SEV msSPRingPtm | 1.3.6.1.4.1.1038.130.20.6.1.24 | Severity | read-write | Severity associed with Potential Traffic Misconnection failure
for MS-SPRing. |
| SEV msSPRingMms | 1.3.6.1.4.1.1038.130.20.6.1.25 | Severity | read-write | Severity associed with Mutiple Multiplex Section Fail failure
for MS-SPRing. |
| SEV msSPRingExr | 1.3.6.1.4.1.1038.130.20.6.1.26 | Severity | read-write | Severity associed with EXeRcise failure
for MS-SPRing. |
| SAG msSPRingSimpleFailure | 1.3.6.1.4.1.1038.130.20.6.1.27 | SagemBoolean | read-write | Indicate if simple or multi ring failure must be considerated |
| MSS msSPRingId | 1.3.6.1.4.1.1038.130.20.6.1.28 | MsSPRingID | read-write | Ring Identifier of the equipement |
| STA msSPRingNodeState | 1.3.6.1.4.1.1038.130.20.6.1.29 | State | read-only | |
| INT msSPRingSwitchingSide | 1.3.6.1.4.1.1038.130.20.6.1.30 | INTEGER | read-only | Switching SideSide |
| TRA msSPRingWestTraffic | 1.3.6.1.4.1.1038.130.20.6.1.31 | TrafficStatus | read-only | The value of this field indicates the protection switch position. |
| TRA msSPRingEastTraffic | 1.3.6.1.4.1.1038.130.20.6.1.32 | TrafficStatus | read-only | The value of this field indicates the protection switch position. |
| MSS msSPRingWestStatus | 1.3.6.1.4.1.1038.130.20.6.1.33 | MsSPRingStatus | read-only | Indicates the local status:
OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8),
manualSwitch-R(6),
waitToRestore(5),exer-R(3),noRequest(0) |
| MSS msSPRingEastStatus | 1.3.6.1.4.1.1038.130.20.6.1.34 | MsSPRingStatus | read-only | Indicates the local status:
OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8),
manualSwitch-R(6),
waitToRestore(5),exer-R(3),noRequest(0) |
| msSPRingTopoMapTable | 1.3.6.1.4.1.1038.130.20.11 | | not-accessible | Topology Map of the ring = West STM index + Val (1<=Val<=16). |
| msSPRingTopoMapEntry | 1.3.6.1.4.1.1038.130.20.11.1 | | not-accessible | A particular entry of the ring topology map. |
| INT msSPRingTopoMapIndex | 1.3.6.1.4.1.1038.130.20.11.1.1 | INTEGER | read-only | index |
| MSS msSPRingTopoMapID | 1.3.6.1.4.1.1038.130.20.11.1.2 | MsSPRingID | read-write | identifier of the node |
| msSPRingMisconMapTable | 1.3.6.1.4.1.1038.130.20.21 | | not-accessible | Connectivity (misconnection) Map of the ring. |
| msSPRingMisconMapEntry | 1.3.6.1.4.1.1038.130.20.21.1 | | not-accessible | A particular entry of the ring connectivity (misconnection) map.
All entries are created after setting the msSPRingWestPointer. |
| INT msSPRingMisconMapIndex | 1.3.6.1.4.1.1038.130.20.21.1.1 | INTEGER | read-only | Index = West STM index + Val (1<=Val<=16)
ADR2500c : val = 1 to 8 for West and 9 to 16 for East |
| MSS msSPRingMisconMapSide | 1.3.6.1.4.1.1038.130.20.21.1.2 | MsSPRingSide | read-only | Side (WestPointer/msSPRingEast) of the interface that supports the AU4 |
| MSS msSPRingMisconMapIn | 1.3.6.1.4.1.1038.130.20.21.1.3 | MsSPRingID | read-write | Node of the ring where the Au4 traffic enters the ring |
| MSS msSPRingMisconMapOut | 1.3.6.1.4.1.1038.130.20.21.1.4 | MsSPRingID | read-write | Node of the ring where the Au4 traffic exits the ring |
| INT msSPRingMisconMapTimeSlot | 1.3.6.1.4.1.1038.130.20.21.1.5 | INTEGER | read-write | Time Slot assignment for the AU4 |
| MIS msSPRingMisconMapType | 1.3.6.1.4.1.1038.130.20.21.1.6 | MisconMapType | read-write | If the value is equal to terminated, the traffic in the ring is inserted
or extracted at this node.
If the value is equal to passedThrough the traffic only cross the node |
| SAG msSPRingMisconMapLOAccess | 1.3.6.1.4.1.1038.130.20.21.1.7 | SagemBoolean | read-write | True if the AU4 is accessed at LO layers somewhere in the ring |
| msSPRingNUTTable | 1.3.6.1.4.1.1038.130.20.31 | | not-accessible | Topology Map of the ring. |
| msSPRingNUTEntry | 1.3.6.1.4.1.1038.130.20.31.1 | | not-accessible | A particular entry of the ring topology map. |
| INT msSPRingNUTIndex | 1.3.6.1.4.1.1038.130.20.31.1.1 | INTEGER | read-only | AU4 index = West STM index + Val (Val = working timeSlot; 1<=Val<=8) |
| SAG msSPRingNUTisNut | 1.3.6.1.4.1.1038.130.20.31.1.2 | SagemBoolean | read-write | Define if the traffic is used for NUT Traffic |
| sncp | 1.3.6.1.4.1.1038.130.30 | | | |
| INT sncNumber | 1.3.6.1.4.1.1038.130.30.1 | INTEGER | read-only | Number of snc in equipment. |
| sncTable | 1.3.6.1.4.1.1038.130.30.2 | | not-accessible | List of snc protection in equipment. |
| sncEntry | 1.3.6.1.4.1.1038.130.30.2.1 | | not-accessible | A particular SNC protection which is created in using the linkTable of the Xconnection MIB. |
| INT sncIndex | 1.3.6.1.4.1.1038.130.30.2.1.1 | INTEGER | read-only | sncIndex = 1000*sncType + sncTTPSink = linkIndex |
| INT sncCTPSink | 1.3.6.1.4.1.1038.130.30.2.1.2 | INTEGER | read-only | The value of this field is the index of the Output Connection to which
an snc function is applied. |
| LIN sncLinkType | 1.3.6.1.4.1.1038.130.30.2.1.3 | LinkType | read-only | Trail level of the connection |
| INT sncCTPSourceW | 1.3.6.1.4.1.1038.130.30.2.1.4 | INTEGER | read-only | The value of this field indicates the Working Input Connection Point which
composes the protection link of the Output Connection Point (sncIndex). |
| INT sncCTPSourceP | 1.3.6.1.4.1.1038.130.30.2.1.5 | INTEGER | read-write | The value of this field indicates the Protected Input Connection Point which
composes the protection link of the Output Connection Point (sncIndex).
When this variable is setting, the protection is created and activated (if it's possible). |
| TRA sncTrafficStatus | 1.3.6.1.4.1.1038.130.30.2.1.6 | TrafficStatus | read-only | This field indicates the Protection unit switch position. |
| TRI sncWorkingTriggerType | 1.3.6.1.4.1.1038.130.30.2.1.8 | TriggerCriterion | read-write | The value of this field is the criterion to trigger a switch for the Working Input
Connection Point.SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 ,
AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs.
SNC/N uses also SD criterion for switching: SD-V5 for VC12,
SD-B3 for VC3/VC4.
SNC+LAN adds MS-RDI as switching criterion for LAN connection.
NONE means that just board extractions and some board failures activate switching. |
| TRI sncProtectionTriggerType | 1.3.6.1.4.1.1038.130.30.2.1.9 | TriggerCriterion | read-write | The value of this field is the criterion to trigger a switch for the Protection Input
Connection Point. SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 ,
AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs.
SNC/N uses also SD criterion for switching: SD-V5 for VC12,
SD-B3 for VC3/VC4.
SNC+LAN adds MS-RDI as switching criterion for LAN connection.
NONE means that just board extractions and some board failures activate switching. |
| SAG sncRevertive | 1.3.6.1.4.1.1038.130.30.2.1.20 | SagemBoolean | read-write | If the value is true the Protection unit function is allowed
to spontaneously switch back to working chanel when it is available.
If not, the snc can switch back to working chanel only if
protection chanel fails. |
| INT sncWtr | 1.3.6.1.4.1.1038.130.30.2.1.21 | INTEGER | read-write | The time (in seconds) the Protection unit function waits before
considering a chanel as good after a fail. |
| SNC sncStateProcess | 1.3.6.1.4.1.1038.130.30.2.1.22 | SNCStateProcess | read-only | The value of this field indicates the state of the snc protection process. |
| INT sncHoldOffTime | 1.3.6.1.4.1.1038.130.30.2.1.23 | INTEGER | read-write | The time in tenth of seconds during which a protection trigger criterion is
ignored. |
| SNC sncCommand | 1.3.6.1.4.1.1038.130.30.2.1.24 | SNCCommand | read-write | Manual or forced commands can be apply to the protection unit.
The forced and manual switch can be refused or cleared by equipment
if a higher priority evenement is received or if the protection chanel
is down. |
| cardp | 1.3.6.1.4.1.1038.130.40 | | | |
| INT cardpNumber | 1.3.6.1.4.1.1038.130.40.1 | INTEGER | read-only | Number of card protections in equipment. |
| cardpTable | 1.3.6.1.4.1.1038.130.40.2 | | not-accessible | List of card protections in equipment. |
| cardpEntry | 1.3.6.1.4.1.1038.130.40.2.1 | | not-accessible | A particular card protection which is created in using the boardTable of the Shelf MIB. |
| INT cardpIndex | 1.3.6.1.4.1.1038.130.40.2.1.1 | INTEGER | read-only | cardpIndex = boardIndex in the Shelf Mib.
This index points to the working board. |
| CAR cardpBoardFamily | 1.3.6.1.4.1.1038.130.40.2.1.2 | CardpFamily | read-only | This field indicates the family of board concerned by the protection. |
| INT cardpReliefIndex | 1.3.6.1.4.1.1038.130.40.2.1.3 | INTEGER | read-write | A reference to the relief card. It must be an existing index in the boardTable of Shelf Mib.
The relief card and the protected Card must below to the same familly.
When this variable is setting, the protection is created and activated (if it's possible). |
| TRA cardpTrafficStatus | 1.3.6.1.4.1.1038.130.40.2.1.4 | TrafficStatus | read-only | Indication of the protection switch position. |
| CAR cardpCommand | 1.3.6.1.4.1.1038.130.40.2.1.5 | CardpCommand | read-write | Manual commands can be apply to the protection unit.
The manual switch can be refused or cleared by equipment
if a higher priority evenement is received or if the protection chanel
is down. |
| CAR cardpStatus | 1.3.6.1.4.1.1038.130.40.2.1.6 | CardpStatus | read-only | Indication of the current protection status |