PROTECTION-MIB :: mspCommand

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPROTECTION-MIBmspCommand

mspCommand

Module: PROTECTION-MIB

OID (symbolic): PROTECTION-MIB::mspCommand

OID (numeric): 1.3.6.1.4.1.1038.130.10.2.1.11

Node type: OBJECT-TYPE

Type: MspCommand

Access: read-write

Description: Manual or forced commands can be apply to the protection switch. The forced and manual switch can be refused or cleared by equipment if a higher priority APS command is received or if the protection chanel is down. When this field is set to manual or forced, the mspTraffic field becomes read-write, and a set can be issued to specifie on which chanel the command does apply. Commands: LP (Lockout of Protection) LW (Lockout of Working channel) FSW (Forced Switch of a Working channel to protection) FSP (Forced Switch of a Protection channel to working) case 1+1 MSW (Manual Switch of a Working channel to protection) MSp (Manual Switch of a Protection channel to working) case 1+1 EXER (EXERcise)

What is mspCommand?

Issues a manual or forced protection command against this MSP entry (e.g. Lockout of Protection, Forced Switch, Manual Switch, Exercise). Setting a manual/forced command also makes mspTraffic writable so the admin can specify exactly which channel the command targets; the equipment may still refuse or clear the command if a higher-priority APS event occurs or the protection channel is down.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1038.130.10.2.1.11
snmpwalk -v2c -c public <target> PROTECTION-MIB::mspCommand

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1038.130.10.2.1.11.1
snmpget -v2c -c public <target> PROTECTION-MIB::mspCommand.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1038.130.10.2.1.11.1 s <value>

Start monitoring SAGEM SDH/radio link transmission equipment (protection switching) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PROTECTION-MIB::mspCommand OID value, configure state conditions and alerts, and monitor any SAGEM SDH/radio link transmission equipment (protection switching) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1038sagemDrSAGEM-DR-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1038.130protectionPROTECTION-MIB
1.3.6.1.4.1.1038.130.10mspPROTECTION-MIB
1.3.6.1.4.1.1038.130.10.2mspTablePROTECTION-MIB
1.3.6.1.4.1.1038.130.10.2.1mspEntryPROTECTION-MIB
1.3.6.1.4.1.1038.130.10.2.1.11mspCommandPROTECTION-MIB