All MIBs › PROTECTION-MIB › sncWtr
sncWtr
Module: PROTECTION-MIB
OID (symbolic): PROTECTION-MIB::sncWtr
OID (numeric): 1.3.6.1.4.1.1038.130.30.2.1.21
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The time (in seconds) the Protection unit function waits before considering a chanel as good after a fail.
What is sncWtr?
Wait-to-restore time, in seconds, that the SNC protection function holds off before treating a recovered channel as good again after a failure, the SNC-level counterpart of mspWtr.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1038.130.30.2.1.21 snmpwalk -v2c -c public <target> PROTECTION-MIB::sncWtr
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1038.130.30.2.1.21.1 snmpget -v2c -c public <target> PROTECTION-MIB::sncWtr.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1038.130.30.2.1.21.1 i <value>
Start monitoring SAGEM SDH/radio link transmission equipment (protection switching) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PROTECTION-MIB::sncWtr OID value, configure state conditions and alerts, and monitor any SAGEM SDH/radio link transmission equipment (protection switching) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1038 | sagemDr | SAGEM-DR-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1038.130 | protection | PROTECTION-MIB |
| 1.3.6.1.4.1.1038.130.30 | sncp | PROTECTION-MIB |
| 1.3.6.1.4.1.1038.130.30.2 | sncTable | PROTECTION-MIB |
| 1.3.6.1.4.1.1038.130.30.2.1 | sncEntry | PROTECTION-MIB |
| 1.3.6.1.4.1.1038.130.30.2.1.21 | sncWtr | PROTECTION-MIB |