| OID symbolic | OID numeric | Type | Access | Description |
| optixsonetFacilityMgt | 1.3.6.1.4.1.2011.2.25.4.20.2 | | | Enter the description for this MIB module. |
| ds3PortAttribTable | 1.3.6.1.4.1.2011.2.25.4.20.2.1 | | not-accessible | The DS3 facilities configuration Table |
| ds3PortAttribEntry | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1 | | not-accessible | The DS3 facilities configuration entry |
| G32 ds3PortIndexSlotId | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.1 | Gauge32 | read-only | Slot number.
This will indicate what is the slot
of the object. |
| G32 ds3PortIndexPortId | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.2 | Gauge32 | read-only | Port Number.
This will indicate what is the Port
of the object. |
| INT ds3PortAttribReq | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.3 | INTEGER | read-write | High or low receive equalizer. |
| INT ds3PortAttribLbo | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.4 | INTEGER | read-write | Line build out.
Line build out (DS3 port) values
Value Description
1 Cable length range from 0 to 225 feet.
2 Cable length range from 226 to 450 feet. |
| INT ds3PortAttribLineCde | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.5 | INTEGER | read-only | DS3 line code. Valid value is B3ZS. |
| INT ds3PortAttribFmt | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.6 | INTEGER | read-write | Frame format. Valid values are CBIT, M23 or UNFRAMED.
For PDM3 unit, if the port type is DS3_ASYN_STS1,
then can be CBIT, M23 or UNFRAMED. If the port
type is DS3_TMUX_DS1 or DS3_SRV_DS1, then the only can be CBIT or M23. |
| INT ds3PortAttribTACC | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.7 | INTEGER | read-write | Defines the DS3 port as a test access port with a selected unique TAP number. |
| INT ds3PortAttribLof2ais | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.8 | INTEGER | read-write | The parameter is provisioned to determine whether or
not to generate DS3 AIS for the DS3 LOF. The Valid
value of this parameter is 'no' and 'yes'.
PQT3/PQT3A/PQT3P/PQT3B units support this parameter. |
| OCT ds3PortAttribSvtimer | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.9 | OCTET STRING | read-write | Signal validation timer in minutes. Valid values are shown below.
Value Description
From 00-03 Signal validation timer in minutes. Only valid if auto in-service feature is supported. is a string, and format is: HH-MM.
to 48-00 HH - Hour, it is an integer ranging from 0 to 48;
MM - Minute, it is an integer ranging from 0 to 59. The longest time is 48 hours. Default is 00-03 (3 minutes). |
| OCT ds3PortAttribPST | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.10 | OCTET STRING | read-write | The primary state of the entity.
Administrative State (PST) Definition
IS Puts the entity in service.
OOS Puts the entity out of service. |
| OCT ds3PortAttribSST | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.11 | OCTET STRING | read-write | The secondary state of the entity.
Administrative State (PST) Definition.
AINS Puts the entity in automatic in-service.
MT Removes the entity from service for maintenance. |
| LPB ds3LoopbackStatus | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.12 | LpbkType | read-write | This variable represents the current state of the
loopback on the DS3 interface. It contains
information about loopbacks established by a
manager and remotely from the far end. |
| G32 ds3LoopbackTimeout | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.13 | Gauge32 | read-only | The remnant time that loop-back will be released. |
| INT ds3RemoteALWFELPBK | 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.14 | INTEGER | read-write | (Optional) Far-end loopback allowance attribute of the port. If it is
enable, the automatic far-end loopbacks are allowed. It is either enable or
disable. The system default is enable. The parameter type is ENABLE_DISABLE,
which disables or enables an attribute.Automatic application of loopbacks
originating from the far end can be initiated on the T3 ports of
a PDM3 card. |
| ds1PortAttribTable | 1.3.6.1.4.1.2011.2.25.4.20.2.2 | | not-accessible | The DS1 facilities configuration Table |
| ds1PortAttribEntry | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1 | | not-accessible | The DS1 facilities configuration entry |
| G32 ds1PortIndexSlotId | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.1 | Gauge32 | read-only | Slot number.
This will indicate what is the slot
of the object. |
| G32 ds1PortIndexPortId | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.2 | Gauge32 | read-only | Port Number.
This will indicate what is the Port of the object.For the Transmux unit this is the DS3 port number.And for other Ds1 units, it's the Ds1 port Number. |
| G32 ds1PortIndexPath | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.3 | Gauge32 | read-only | Ds1 identifier of the Transmux unit .For DS1 in a Transmux unit, it is equivalent to DS1 port number of its Transmux unit.
For other Ds1 units, It will be zero. |
| INT ds1PortAttribLbo | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.4 | INTEGER | read-write | Line build out.
Line build out (DS1 port) values
Value Description
1 Cable length range from 0 to 131 feet.
2 Cable length range from 132 to 262 feet.
3 Cable length range from 263 to 393 feet.
4 Cable length range from 394 to 524 feet.
5 Cable length range from 525 to 655 feet. |
| INT ds1PortAttribLineCde | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.5 | INTEGER | read-write | DS1 Line coding. Valid value is AMI or B8ZS. Default is B8ZS. |
| INT ds1PortAttribFmt | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.6 | INTEGER | read-write | Frame format. Valid value is SF, ESF or UNFRAMED. |
| INT ds1PortAttribTACC | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.7 | INTEGER | read-write | Defines the DS1/T1 port as a test access port with a selected unique TAP number. |
| INT ds1PortAttribLof2ais | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.8 | INTEGER | read-write | The parameter is provisioned to determine whether or not to generate DS1 AIS for the DS1 LOF |
| OCT ds1PortAttribSvtimer | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.9 | OCTET STRING | read-write | Signal validation timer in minutes. Valid values are shown below.
Value Description
From 00-03 Signal validation timer in minutes. Only valid if auto in-service feature is supported. is a string, and format is: HH-MM.
to 48-00 HH - Hour, it is an integer ranging from 0 to 48;
MM - Minute, it is an integer ranging from 0 to 59. The longest time is 48 hours. Default is 00-03 (3 minutes). |
| OCT ds1PortAttribPST | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.10 | OCTET STRING | read-write | The primary state of the entity.
Administrative State (PST) Definition
IS Puts the entity in service.
OOS Puts the entity out of service. |
| OCT ds1PortAttribSST | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.11 | OCTET STRING | read-write | The secondary state of the entity.
Administrative State (PST) Definition.
AINS Puts the entity in automatic in-service.
MT Removes the entity from service for maintenance. |
| LPB ds1LoopbackStatus | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.12 | LpbkType | read-write | This variable represents the current state of the
loopback on the DS1 interface. It contains
information about loopbacks established by a
manager and remotely from the far end. |
| G32 ds1LoopbackTimeout | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.13 | Gauge32 | read-only | The remnant time that loop-back will be released. |
| INT ds1RemoteALWFELPBK | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.14 | INTEGER | read-write | (Optional) Far-end loopback allowance attribute of the port. If it is
enable, the automatic far-end loopbacks are allowed. It is either enable or
disable. The system default is enable. The parameter type is ENABLE_DISABLE,
which disables or enables an attribute.Automatic application of loopbacks
originating from the far end can be initiated on the T1 ports of
a PLT1,PDT1,PDT1P card.It indicates that the port not support this parameter
when the attribute is invalid. |
| G32 ds1PortLpbkAutomaticTime | 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.15 | Gauge32 | read-write | Time-out ticks (1 minute). For the T1 port default value is 120 (2 hours). 0 means time-out function is disabling. Valid values are 0~9999. |
| portTypeTable | 1.3.6.1.4.1.2011.2.25.4.20.2.3 | | not-accessible | Port type management table. |
| portTypeEntry | 1.3.6.1.4.1.2011.2.25.4.20.2.3.1 | | not-accessible | Port type management entry. |
| G32 portIndexSlotId | 1.3.6.1.4.1.2011.2.25.4.20.2.3.1.1 | Gauge32 | read-only | Slot number.
This will indicate what is the slot
of the object. |
| G32 portIndexPortId | 1.3.6.1.4.1.2011.2.25.4.20.2.3.1.2 | Gauge32 | read-only | Port Number.
This will indicate what is the Port
of the object. |
| NUM portType | 1.3.6.1.4.1.2011.2.25.4.20.2.3.1.3 | IntfType | read-write | The AID unit port type.Valid values are shown below.
INTFTYPE values
Value Description
DS3_ASYN_STS1 DS3 signal asynchronous mapped into STS1. Default for DS3 unit.
DS3_TMUX_DS1 Multiplexing and de-multiplexing of DS1s to/from DS3. Default for Transmux unit (PDM3).
DS1_ASYN_VT1 DS1 signal asynchronous mapped into VT1. Default for DS1 unit.
DS3_SRV_DS1 Multiplexing and de-multiplexing of DS1s to/from DS3 as M13 server.
EC1 EC1 signal mapped into STS1. PQT3A support EC1 service.
UAS It indicates there is no use of the port. |
| optixsonetFacilityMgtConformance | 1.3.6.1.4.1.2011.2.25.4.20.2.4 | | | |
| optixsonetFacilityMgtGroups | 1.3.6.1.4.1.2011.2.25.4.20.2.4.1 | | | |
| currentObjectGroup | 1.3.6.1.4.1.2011.2.25.4.20.2.4.1.1 | | | Enter the description of the created OBJECT-GROUP. |
| optixsonetFacilityMgtCompliances | 1.3.6.1.4.1.2011.2.25.4.20.2.4.2 | | | |
| basicCompliance | 1.3.6.1.4.1.2011.2.25.4.20.2.4.2.1 | | | Enter the description of the created MODULE-COMPLIANCE. |