OMNI-gx2RFA1000-MIB :: gx2Rfa1000HoldTimeData

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsOMNI-gx2RFA1000-MIBgx2Rfa1000HoldTimeData

gx2Rfa1000HoldTimeData

Module: OMNI-gx2RFA1000-MIB

OID (symbolic): OMNI-gx2RFA1000-MIB::gx2Rfa1000HoldTimeData

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.22.6.5.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.

What is gx2Rfa1000HoldTimeData?

Sets the hold (debounce) time, in seconds from 0 to 1300, used to suppress noise on the alarm identified by this row's index before an alarm condition is reported. An admin raises this on a module that's throwing nuisance alarms from brief, transient readings, so only a sustained out-of-range condition actually triggers an alarm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.22.6.5.3
snmpwalk -v2c -c public <target> OMNI-gx2RFA1000-MIB::gx2Rfa1000HoldTimeData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.22.6.5.3.1
snmpget -v2c -c public <target> OMNI-gx2RFA1000-MIB::gx2Rfa1000HoldTimeData.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.22.6.5.3.1 i <value>

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RFA1000 RF amplifier module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2RFA1000-MIB::gx2Rfa1000HoldTimeData OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 RFA1000 RF amplifier module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.22gx2Rfa1000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.22.6gx2Rfa1000HoldTimeTableOMNI-gx2RFA1000-MIB
1.3.6.1.4.1.1166.6.1.2.22.6.5gx2Rfa1000HoldTimeEntryOMNI-gx2RFA1000-MIB
1.3.6.1.4.1.1166.6.1.2.22.6.5.3gx2Rfa1000HoldTimeDataOMNI-gx2RFA1000-MIB