rxgx2Osw10bHoldTimeData

Module: OMNI-gx2OSW10B-MIB

OID (symbolic): OMNI-gx2OSW10B-MIB::rxgx2Osw10bHoldTimeData

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.15.6.5.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.

What is rxgx2Osw10bHoldTimeData?

Read-write INTEGER (0-1300 seconds) that sets the alarm hold/debounce timer for the analog alarm object identified by this row's spec index, so a brief noise spike on an optical-level or temperature reading doesn't immediately trip an alarm; validation data occupies the object's first two bytes and the actual hold-time value the last two.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.15.6.5.3
snmpwalk -v2c -c public <target> OMNI-gx2OSW10B-MIB::rxgx2Osw10bHoldTimeData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.15.6.5.3.1
snmpget -v2c -c public <target> OMNI-gx2OSW10B-MIB::rxgx2Osw10bHoldTimeData.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.15.6.5.3.1 i <value>

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 OSW10B optical switch module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2OSW10B-MIB::rxgx2Osw10bHoldTimeData OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 OSW10B optical switch module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.15gx2Osw10bGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.15.6gx2Osw10bHoldTimeTableOMNI-gx2OSW10B-MIB
1.3.6.1.4.1.1166.6.1.2.15.6.5gx2Osw10bHoldTimeEntryOMNI-gx2OSW10B-MIB
1.3.6.1.4.1.1166.6.1.2.15.6.5.3rxgx2Osw10bHoldTimeDataOMNI-gx2OSW10B-MIB