Category: Hardware Inventory

Description:

Manages NMS Communications chassis hardware configuration, slot inventory, and module status for enterprise switches.

Imported Objects

From NMS-SMI

nmstemporaryOBJECT-IDENTITY

From RFC-1212

OBJECT-TYPE

From RFC1155-SMI

Gauge32
TimeTicks

From RFC1213-MIB

DisplayString

What Is NMS-CHASSIS?

NMS-CHASSIS is a hardware-inventory MIB from NMS Communications for managing chassis-based telecom/media-processing equipment, covering chassis configuration, slot inventory, and per-module status. It belongs to the telecom media gateway/DSP hardware platform technology area. Its data centers on physical hardware inventory and status — chassis slot occupancy, installed module identification, and module operational state. It is explicitly aimed at monitoring hardware status: verifying which modules are present in which slots, whether each module is operating normally or has failed, and overall chassis health, which is central to detecting hardware faults in a modular telecom platform. No sample objects were provided, so a full NMS-CHASSIS OID list cannot be confirmed from this batch, but the module clearly depends on standard entity/chassis conventions common to modular telecom hardware MIBs. It is deployed in telecom/media-gateway environments running NMS Communications chassis-based DSP or voice-processing platforms.

IPNetwork Monitor allows you to monitor SNMP objects defined in NMS-CHASSIS. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • NMS Communications chassis-based media/DSP processing platforms

Monitoring Examples

No concrete sample objects were supplied for NMS-CHASSIS, so a specific polling scenario using real object names cannot be honestly constructed; based on the module's description an operator would likely poll a slot/module status table to detect an empty or failed slot, but this is inferred rather than object-verified.

OIDs
OID symbolicOID numericTypeAccessDescription
nmschassis1.3.6.1.4.1.11606.10.3.6
INT nmschassisType1.3.6.1.4.1.11606.10.3.6.1INTEGERread-onlyChassis type.
STR nmschassisVersion1.3.6.1.4.1.11606.10.3.6.2DisplayStringread-onlyChassis hardware revision level, or an empty string if unavailable.
STR nmschassisId1.3.6.1.4.1.11606.10.3.6.3DisplayStringread-writeUnique ID string. Defaults to chassis serial number if available, otherwise empty.
STR nmsromSysVersion1.3.6.1.4.1.11606.10.3.6.4DisplayStringread-onlyROM system software version, or an empty string if unavailable.
INT nmsprocessorRam1.3.6.1.4.1.11606.10.3.6.5INTEGERread-onlyBytes of RAM available to CPU.
INT nmsnvRAMSize1.3.6.1.4.1.11606.10.3.6.6INTEGERread-onlyBytes of non-volatile configuration memory.
INT nmsnvRAMUsed1.3.6.1.4.1.11606.10.3.6.7INTEGERread-onlyBytes of non-volatile configuration memory in use.
INT nmsconfigRegister1.3.6.1.4.1.11606.10.3.6.8INTEGERread-onlyValue of configuration register.
INT nmsconfigRegNext1.3.6.1.4.1.11606.10.3.6.9INTEGERread-onlyValue of configuration register at next reload.
nmscardTable1.3.6.1.4.1.11606.10.3.6.10not-accessibleChassis card table.
nmscardTableEntry1.3.6.1.4.1.11606.10.3.6.10.1not-accessibleChassis card table.
INT nmscardIndex1.3.6.1.4.1.11606.10.3.6.10.1.1INTEGERread-onlyIndex into cardTable (not physical chassis slot number).
INT nmscardType1.3.6.1.4.1.11606.10.3.6.10.1.2INTEGERread-onlyFunctional type of this card.
STR nmscardDescr1.3.6.1.4.1.11606.10.3.6.10.1.3DisplayStringread-onlyText description of this card.
STR nmscardSerial1.3.6.1.4.1.11606.10.3.6.10.1.4DisplayStringread-onlyThe serial number of this card, or 0 if unavailable.
STR nmscardHwVersion1.3.6.1.4.1.11606.10.3.6.10.1.5DisplayStringread-onlyHardware revision level of this card, or an empty string if unavailable.
STR nmscardSwVersion1.3.6.1.4.1.11606.10.3.6.10.1.6DisplayStringread-onlyVersion of the firmware or microcode installed on this card, or an empty string if unavailable.
INT nmscardSlotNumber1.3.6.1.4.1.11606.10.3.6.10.1.7INTEGERread-onlySlot number relative to the containing card or chassis, or -1 if neither applicable nor determinable.
INT nmscardContainedByIndex1.3.6.1.4.1.11606.10.3.6.10.1.8INTEGERread-onlycardIndex of the parent card which directly contains this card, or 0 if contained by the chassis, or -1 if not applicable nor determinable.
INT nmscardOperStatus1.3.6.1.4.1.11606.10.3.6.10.1.9INTEGERread-onlyThe operational status of the card. nmscardOperStatus is up when a card is recognized by the device and is enabled for operation. nmscardOperStatus is down if the card is not recognized by the device, or if it is not enabled for operation. nmscardOperStatus is standby if the card is enabled and acting as a standby slave
INT nmscardSlots1.3.6.1.4.1.11606.10.3.6.10.1.10INTEGERread-onlyNumber of slots on this card, or 0 if no slots or not applicable, or -1 if not determinable.
INT nmscardCPUUtilization1.3.6.1.4.1.11606.10.3.6.10.1.11INTEGERread-onlyCPU Utilization of Card. unit:1%
INT nmscardMEMUtilization1.3.6.1.4.1.11606.10.3.6.10.1.12INTEGERread-onlyMemory Utilization of Card. unit:1%
INT nmscardTemperature1.3.6.1.4.1.11606.10.3.6.10.1.13INTEGERread-onlyTemperature of Card. unit: C
INT nmscardVoltage1.3.6.1.4.1.11606.10.3.6.10.1.14INTEGERread-onlyVoltage of Card. unit: V
INT nmscardPorts1.3.6.1.4.1.11606.10.3.6.10.1.15INTEGERread-onlyprots contained on the card
INT nmscardGenType1.3.6.1.4.1.11606.10.3.6.10.1.16INTEGERread-onlythe card genenral type
INT nmschassisSlots1.3.6.1.4.1.11606.10.3.6.11INTEGERread-onlyNumber of slots in this chassis, or -1 of neither applicable nor determinable.
nmscardIfIndexTable1.3.6.1.4.1.11606.10.3.6.12not-accessibleChassis card table.
nmscardIfIndexEntry1.3.6.1.4.1.11606.10.3.6.12.1not-accessibleChassis card table.
INT nmscardIfIndex1.3.6.1.4.1.11606.10.3.6.12.1.1INTEGERread-onlymatches RFC1213/RFC2233 ifTable IfIndex
INT nmscardIfPortNumber1.3.6.1.4.1.11606.10.3.6.12.1.2INTEGERread-onlyChassis port number, unique per port on a given card if available.
INT nmscardIfSlotNumber1.3.6.1.4.1.11606.10.3.6.12.1.3INTEGERread-onlynmscardIndex of the card in the Chassis nmscardTable which contains this interface.
INT nmscardIfConnectorTypeEnabled1.3.6.1.4.1.11606.10.3.6.12.1.4INTEGERread-onlyInterface connector type currently enabled. Value will be 1 if not known or not used, or 2 if none of this ports' interface connectors are enabled.
INT nmscardIfCardIndex1.3.6.1.4.1.11606.10.3.6.12.1.5INTEGERread-onlynmscardIndex of the card in the Chassis nmscardTable which contains this interface.
TIK nmssysUpTimeAtLastChassisChange1.3.6.1.4.1.11606.10.3.6.13TimeTicksread-onlyTime in seconds100 from the last cold start to the last change in the chassis configuration. This value will be updated whenever the chassis experiences a change in the count, type, or slot position of a card in cardTable.
INT nmsBoxTemp1.3.6.1.4.1.11606.10.3.6.14INTEGERread-onlyThe environment temperature in the mechine box.
nmsAuxTable1.3.6.1.4.1.11606.10.3.6.15not-accessibleA list of Auxiliary devices status entries.
nmsAuxEntry1.3.6.1.4.1.11606.10.3.6.15.1not-accessibleAn entry of auxiliary devices status table.
G32 nmsAuxIndex1.3.6.1.4.1.11606.10.3.6.15.1.1Gauge32read-onlyThe index of Aux status table.
STR nmsAuxDescr1.3.6.1.4.1.11606.10.3.6.15.1.2DisplayStringread-onlyThe description of an auxiliary device.
INT nmsAuxClass1.3.6.1.4.1.11606.10.3.6.15.1.3INTEGERread-onlyAuxiliary device,such as power supply ,fan...
INT nmsAuxMode1.3.6.1.4.1.11606.10.3.6.15.1.4INTEGERread-onlyThe working mode of an auxiliary device.
INT nmsAuxState1.3.6.1.4.1.11606.10.3.6.15.1.5INTEGERread-onlyThe state of an auxiliary device.
nmssubcardTable1.3.6.1.4.1.11606.10.3.6.16not-accessibleChassis subcard table.
nmssubcardTableEntry1.3.6.1.4.1.11606.10.3.6.16.1not-accessibleChassis subcard table.
INT nmssubcardIndex1.3.6.1.4.1.11606.10.3.6.16.1.1INTEGERread-onlyIndex into subcardTable (not physical chassis slot number).
INT nmssubcardType1.3.6.1.4.1.11606.10.3.6.16.1.2INTEGERread-onlyFunctional type of this subcard.
STR nmssubcardDescr1.3.6.1.4.1.11606.10.3.6.16.1.3DisplayStringread-onlyText description of this subcard.
STR nmssubcardSerial1.3.6.1.4.1.11606.10.3.6.16.1.4DisplayStringread-onlyThe serial number of this subcard, or 0 if unavailable.
STR nmssubcardHwVersion1.3.6.1.4.1.11606.10.3.6.16.1.5DisplayStringread-onlyHardware revision level of this subcard, or an empty string if unavailable.
STR nmssubcardSwVersion1.3.6.1.4.1.11606.10.3.6.16.1.6DisplayStringread-onlyVersion of the firmware or microcode installed on this subcard, or an empty string if unavailable.
INT nmssubcardShelfNumber1.3.6.1.4.1.11606.10.3.6.16.1.7INTEGERread-onlySlot number relative to the containing subcard or chassis, or -1 if neither applicable nor determinable.
INT nmssubcardContainedByIndex1.3.6.1.4.1.11606.10.3.6.16.1.8INTEGERread-onlysubcardIndex of the parent subcard which directly contains this subcard, or 0 if contained by the chassis, or -1 if not applicable nor determinable.
INT nmssubcardOperStatus1.3.6.1.4.1.11606.10.3.6.16.1.9INTEGERread-onlyThe operational status of the subcard. nmssubcardOperStatus is up when a subcard is recognized by the device and is enabled for operation. nmssubcardOperStatus is down if the subcard is not recognized by the device, or if it is not enabled for operation. nmssubcardOperStatus is standby if the subcard is enabled and acting as a standby slave
INT nmssubcardSlots1.3.6.1.4.1.11606.10.3.6.16.1.10INTEGERread-onlyNumber of slots on this subcard, or 0 if no slots or not applicable, or -1 if not determinable.
INT nmssubcardContainedByShelf1.3.6.1.4.1.11606.10.3.6.16.1.11INTEGERread-only
INT nmssubcardSlotNumber1.3.6.1.4.1.11606.10.3.6.16.1.12INTEGERread-only
INT nmssubcardPorts1.3.6.1.4.1.11606.10.3.6.16.1.13INTEGERread-only
INT nmsHumidity1.3.6.1.4.1.11606.10.3.6.17INTEGERread-onlyValue of chassis humidity.
INT nmsSysErrorNum1.3.6.1.4.1.11606.10.3.6.18INTEGERread-onlyValue of sys error number.
INT nmsElectricCurrent1.3.6.1.4.1.11606.10.3.6.19INTEGERread-onlyValue of electric current.
INT nmsVoltageCurrent1.3.6.1.4.1.11606.10.3.6.20INTEGERread-onlyValue of electric current.

RFC description

Manages physical chassis components and hardware status for NMS telecommunications equipment.

Start monitoring NMS Communications chassis-based media/DSP processing platform with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download NMS-CHASSIS