NMS-CHASSIS :: nmsAuxClass

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNMS-CHASSISnmsAuxClass

nmsAuxClass

Module: NMS-CHASSIS

OID (symbolic): NMS-CHASSIS::nmsAuxClass

OID (numeric): 1.3.6.1.4.1.11606.10.3.6.15.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Auxiliary device,such as power supply ,fan...

What is nmsAuxClass?

Identifies the type of auxiliary device this table row describes: power(1) for a power supply, or fan(2) for a cooling fan. An admin uses this to filter the auxiliary table down to just power supplies or just fans when investigating a specific subsystem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11606.10.3.6.15.1.3
snmpwalk -v2c -c public <target> NMS-CHASSIS::nmsAuxClass

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11606.10.3.6.15.1.3.1
snmpget -v2c -c public <target> NMS-CHASSIS::nmsAuxClass.1

Start monitoring NMS Communications chassis-based media/DSP processing platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NMS-CHASSIS::nmsAuxClass OID value, configure state conditions and alerts, and monitor any NMS Communications chassis-based media/DSP processing platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11606pbnPBN-ROOT
1.3.6.1.4.1.11606.10nmsNMS-SMI
1.3.6.1.4.1.11606.10.3nmstemporaryNMS-SMI
Numeric OIDNameModule
1.3.6.1.4.1.11606.10.3.6nmschassisNMS-CHASSIS
1.3.6.1.4.1.11606.10.3.6.15nmsAuxTableNMS-CHASSIS
1.3.6.1.4.1.11606.10.3.6.15.1nmsAuxEntryNMS-CHASSIS
1.3.6.1.4.1.11606.10.3.6.15.1.3nmsAuxClassNMS-CHASSIS