Module: LaserJet-Series8000-MIB

OID (symbolic): LaserJet-Series8000-MIB::hrdeviceerrors

OID (numeric): 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. However, it is recommended that this object be initialized to zero. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Additional information (printer): Total number of read and write errors that have occurred since the printer was turned on. Returns status if attempting to perform a Get on this OID with no mass storage device installed. Returns 0 if the mass storage device is uninitialized. Additional information (mass storage): This is the number of critical alerts that have been entered into the alert table since the device was powered on. The maximum value for this object is 2^32-1. At power-on, this object will be set to zero.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6
snmpwalk -v2c -c public <target> LaserJet-Series8000-MIB::hrdeviceerrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6.1
snmpget -v2c -c public <target> LaserJet-Series8000-MIB::hrdeviceerrors.1

Start monitoring HP LaserJet 8000 series printer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LaserJet-Series8000-MIB::hrdeviceerrors OID value, configure state conditions and alerts, and monitor any HP LaserJet 8000 series printer from a single console.

How to Use in IPNetwork Monitor

Select an HP LaserJet 8000 series printer as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hrdeviceerrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of errors detected on this device. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (16 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9net_peripheralCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4netdmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2dmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.3hrmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.3.3hrDeviceCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2hrDeviceTableCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1hrDeviceEntryCLJ8500-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6hrdeviceerrorsLaserJet-Series8000-MIB