LIEBERT-SERIES-300-UPS-MIB

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsLIEBERT-SERIES-300-UPS-MIB

Category: Domain: Power/UPS, Vendor: Liebert

Description: Provides SNMP objects for managing the Liebert Series 300 UPS product line, covering input/output power and battery monitoring.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is LIEBERT-SERIES-300-UPS-MIB?

This is a Liebert MIB for managing the Series 300 Uninterruptible Power Supply (UPS) product line, covering input/output power characteristics and battery status. It exposes objects related to AC input/output voltage, current, and frequency, along with battery charge and runtime status, which together describe the electrical and backup-power health of the UPS unit. It is directly focused on monitoring hardware status such as battery health/charge level, on-battery/on-line operational state, and input power quality, all critical for detecting impending power failures or battery degradation. As a self-contained Liebert enterprise MIB it does not appear to depend on external vendor MIBs beyond standard SNMP conventions. It is deployed in data centers, telecom rooms, and server closets protected by a Liebert Series 300 UPS. Engineers can download the LIEBERT-SERIES-300-UPS-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in LIEBERT-SERIES-300-UPS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Liebert Series 300 UPS

Monitoring Examples

A facilities monitoring system would poll battery state-of-charge and runtime-remaining objects to predict how long the UPS can sustain a load during a power outage, alerting if runtime drops below a safety threshold. Input voltage/frequency objects would be checked to detect utility power sag or instability that triggered a transfer to battery, while output objects confirm the UPS is properly supplying connected equipment. A sustained on-battery operational state combined with declining battery charge would signal an imminent shutdown risk.

What Can Be Monitored

  • battery charge level
  • battery runtime remaining
  • on-line/on-battery operational state
  • input voltage and frequency
  • output voltage and load
Imported Objects

From RFC-1212

OBJECT-TYPE

From RFC-1215

TRAP-TYPE

From RFC1155-SMI

Counter
Gauge
TimeTicks
enterprises

From RFC1213-MIB

DisplayString
sysUpTime
OIDs

RFC description

Monitors power status and controls Liebert Series 300 uninterruptible power supply devices.

Start monitoring Liebert UPS systems with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download LIEBERT-SERIES-300-UPS-MIB