All MIBs › LANART-MIB
Category: Network Interfaces
Description:
LANART Corporation MIB for managing LANART network equipment including repeaters and network interface devices.
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| IpAddress | |
| NetworkAddress | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString |
From SNMP-REPEATER-MIB
| rptrPortOperStatus | OBJECT-TYPE |
What Is LANART-MIB?
LANART-MIB is a LANART Corporation enterprise MIB for managing LANART's network equipment, including repeaters and network interface/hub devices, based on its object names covering system configuration, link alerting, and twisted-pair port status. It exposes general system configuration, a link-alert facility, and a twisted-pair port table describing per-port state on hub/repeater hardware. Its monitoring purpose centers on hardware/link status: the twisted-pair port table and link-alert objects let an admin see whether individual repeater/hub ports have an active link and raise an alert when a port's link state changes, which is a hardware-connectivity health check for the device's ports. No explicit dependency on other standard MIBs is indicated in the available source. It was deployed on LANART Ethernet hubs/repeaters and related network interface devices in legacy Ethernet LAN installations, and administrators supporting such gear today typically start with a LANART-MIB download to load the module into their SNMP tool.
IPNetwork Monitor allows you to monitor SNMP objects defined in LANART-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- per-port twisted-pair link status
- link-alert notifications
- overall device system configuration
Supported Devices
- LANART Ethernet hub/repeater and network interface device
Monitoring Examples
An operator can poll laTpPortTable (via laTpPortEntry) to check the link status of each twisted-pair port on a LANART hub/repeater, and watch laLinkAlert for notifications when a port's link state changes — for example, flagging a port that has unexpectedly gone down. laSysConfig exposes overall device configuration relevant to interpreting those per-port readings.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| lanart | 1.3.6.1.4.1.712 | |||
| NTF laPortStatus | 1.3.6.1.4.1.712.0.1 | The laPortStatus trap conveys a change in status of a particular port. This trap is sent for a given port when either of the following status variables change for that port: rptrPortAdminStatus, laTpLinkTest The rptrHealth trap contains the rptrPortOperStatus object. | ||
| laMib1 | 1.3.6.1.4.1.712.1 | |||
| laProducts | 1.3.6.1.4.1.712.1.1 | |||
| laTpHub | 1.3.6.1.4.1.712.1.1.1 | |||
| laTpHub1 | 1.3.6.1.4.1.712.1.1.1.1 | |||
| etm120x | 1.3.6.1.4.1.712.1.1.1.1.12 | |||
| etm160x | 1.3.6.1.4.1.712.1.1.1.1.16 | |||
| etm240x | 1.3.6.1.4.1.712.1.1.1.1.24 | |||
| laTpHub2 | 1.3.6.1.4.1.712.1.1.1.2 | |||
| ete120x | 1.3.6.1.4.1.712.1.1.1.2.12 | |||
| ete160x | 1.3.6.1.4.1.712.1.1.1.2.16 | |||
| ete240x | 1.3.6.1.4.1.712.1.1.1.2.24 | |||
| laTpHub3 | 1.3.6.1.4.1.712.1.1.1.3 | |||
| bbAui | 1.3.6.1.4.1.712.1.1.1.3.0 | |||
| bbAuiTp | 1.3.6.1.4.1.712.1.1.1.3.1 | |||
| bbAuiBnc | 1.3.6.1.4.1.712.1.1.1.3.2 | |||
| bbAuiTpBnc | 1.3.6.1.4.1.712.1.1.1.3.3 | |||
| bbAui10BASE_FL | 1.3.6.1.4.1.712.1.1.1.3.4 | |||
| laHubMib | 1.3.6.1.4.1.712.1.2 | |||
| laSys | 1.3.6.1.4.1.712.1.2.1 | |||
| INT laSysConfig | 1.3.6.1.4.1.712.1.2.1.1 | INTEGER | read-write | Setting this object to save(1) will save all configuration variables to non-volatile memory. Setting this object to load(2) will configure the hub according to the stored configuration. Setting this object to factory(3) will configure the hub according to the factory settings. A return value of ok(4) means the non-volatile memory is operational. A return value of failed(5) means the non-volatile memory has failed. |
| INT laJoystick | 1.3.6.1.4.1.712.1.2.1.2 | INTEGER | read-write | Setting this object to disabled(2) prevents use of the four-position switch on the front panel. Resetting this object to enabled(1) allows use of the switch. |
| INT laLinkAlert | 1.3.6.1.4.1.712.1.2.1.3 | INTEGER | read-write | Setting this object enables or disables the LinkALERT feature of the backbone 10BASE-T or 10BASE-FL port. A return value of not-applicable indicates that none of the backbone ports feature LinkALERT. |
| laTpPort | 1.3.6.1.4.1.712.1.2.2 | |||
| laTpPortTable | 1.3.6.1.4.1.712.1.2.2.1 | not-accessible | Table of descriptive and status information about the ports. | |
| laTpPortEntry | 1.3.6.1.4.1.712.1.2.2.1.1 | not-accessible | An entry in the table, containing information about a single port. | |
| INT laTpPortGroupIndex | 1.3.6.1.4.1.712.1.2.2.1.1.1 | INTEGER | read-only | This object identifies the group containing the port for which this entry contains information. |
| INT laTpPortIndex | 1.3.6.1.4.1.712.1.2.2.1.1.2 | INTEGER | read-only | This object identifies the port within the group for which this entry contains information. |
| INT laTpLinkTest | 1.3.6.1.4.1.712.1.2.2.1.1.3 | INTEGER | read-write | Setting this object to disabled(2) disables the link test feature. This may be useful for interoperation with pre-10BASE-T equipment. Setting this object to enabled(1) enables the feature. A return value of failed(3) indicates a link test failure for this port. A return value of not-applicable(4) indicates that the specified port does not have a link test. |
| INT laTpAutoPolarity | 1.3.6.1.4.1.712.1.2.2.1.1.4 | INTEGER | read-write | Setting this object to disabled(2) disables the auto polarity test for this port. Setting this object to enabled(1) enables the feature. A return value of corrected(3) indicates that the polarity test has sensed a reversal on the receive wiring pair, and has corrected this fault by inverting its receive signal. A return value of not-applicable(4) indicates that the specified port does not support polarity correction. |
RFC description
Manages LAN Art hub products including system configuration, port status, and repeater management.
Start monitoring LANART Ethernet hub/repeater and network interface device with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.