Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is IES5206-TRAPS-MIB?
IES5206-TRAPS-MIB is a vendor-specific SNMP notification (trap) MIB associated with the IES 5206 network access device, apparently a broadband/access aggregation platform. As a traps-only module it belongs to the fault-management area of network device monitoring rather than defining polled data objects. It exposes categories of data limited to asynchronous event notifications - system alarms, hardware faults, and configuration-change events - rather than a browsable table of live counters. Its practical monitoring value is alerting a network operations center to hardware failures, link-status changes, or system resets on the IES 5206 platform as they occur, complementing periodic polling of other status MIBs. It likely depends on the standard SNMPv2 notification framework (SNMPv2-TC/SNMPv2-CONF) for its trap definitions, and is deployed wherever IES 5206 access devices sit at a carrier or enterprise network edge. Network engineers evaluating or troubleshooting this functionality can download the IES5206-TRAPS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in IES5206-TRAPS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- IES 5206 access/aggregation device
Monitoring Examples
No module description or sample objects were available for this MIB, so specific trap object names cannot be grounded; its documented purpose, inferred from the module name, is limited to defining vendor-specific SNMP trap notifications (such as alarm-raised/alarm-cleared or link-state events) for the IES 5206 device rather than exposing a pollable data table.
What Can Be Monitored
- system alarm traps
- hardware fault events
- link up/down notifications
- configuration change events
This MIB depends on
Related MIBs
Imported Objects
| IANAItuEventType | |
| IANAItuProbableCause |
From IES5206-MIB
| coaConfAnalyticMethod | OBJECT-TYPE |
| coaConfIssueThreshold | OBJECT-TYPE |
| ies5206 | MODULE-IDENTITY |
| slotModuleId | OBJECT-TYPE |
| sysBootupFwVersion | OBJECT-TYPE |
| sysFwUpgradeStatus | OBJECT-TYPE |
| temperatureConfIndex | OBJECT-TYPE |
| temperatureCurValue | OBJECT-TYPE |
| transceiverDdmInfoEntryAlarmMax | OBJECT-TYPE |
| transceiverDdmInfoEntryAlarmMin | OBJECT-TYPE |
| transceiverDdmInfoEntryCurrent | OBJECT-TYPE |
| transceiverDdmInfoEntryType | OBJECT-TYPE |
| transceiverDdmInfoEntryWarnMax | OBJECT-TYPE |
| transceiverDdmInfoEntryWarnMin | OBJECT-TYPE |
| transceiverPerOntRxPower | OBJECT-TYPE |
| voltageConfIndex | OBJECT-TYPE |
| voltageCurValue | OBJECT-TYPE |
From IF-MIB
| ifAdminStatus | OBJECT-TYPE |
| ifOperStatus | OBJECT-TYPE |
From RFC1213-MIB
| DisplayString | |
| ifIndex |
From SNMPv2-SMI
| IpAddress | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
How to Use in IPNetwork Monitor
Example using gponRogueOntDetectStatus OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| trap | 1.3.6.1.4.1.890.1.5.13.13.19 | |||
| object | 1.3.6.1.4.1.890.1.5.13.13.19.1 | |||
| INT loopguardSenderIfIndex | 1.3.6.1.4.1.890.1.5.13.13.19.1.1 | INTEGER | not-accessible | A unique value, greater than zero, for each interface. The index of sender interface which sends detected loop guard probe packet. |
| STR sysProblemCause | 1.3.6.1.4.1.890.1.5.13.13.19.1.2 | DisplayString | not-accessible | It describes the problem occurred in the system, e.g. maintenance operation failures, system reboot, error log, ...etc. 1: cold start by power cycle, HW_WDG, overheat, maintenance button, ... 2: operatos reboots the system |
| INT sysMacAntiSpoofOrig | 1.3.6.1.4.1.890.1.5.13.13.19.1.3 | INTEGER | not-accessible | The Original ifIndex of Mac-AntiSpoofing. |
| INT sysMacAntiSpoofNew | 1.3.6.1.4.1.890.1.5.13.13.19.1.4 | INTEGER | not-accessible | The New ifIndex of Mac-AntiSpoofing. |
| STR sysMacAntiSpoofMAC | 1.3.6.1.4.1.890.1.5.13.13.19.1.5 | DisplayString | not-accessible | The MAC of Mac-AntiSpoofing. |
| U32 sysCoaIssuedLoad | 1.3.6.1.4.1.890.1.5.13.13.19.1.6 | Unsigned32 | not-accessible | CPU analyzed utilization when CPU overload alarm is issued. |
| INT xdslDevId | 1.3.6.1.4.1.890.1.5.13.13.19.1.13 | INTEGER | read-only | The device ID of DSP device on board. |
| INT timerefSource | 1.3.6.1.4.1.890.1.5.13.13.19.1.18 | INTEGER | read-only | The system receive timing reference signal correctly. The varable in the binding list is current reference, 0: freerun, 1: GPS module, 2: IEEE 1588, 3: SyncE |
| U32 dhcpServerIpv4Address | 1.3.6.1.4.1.890.1.5.13.13.19.1.19 | Unsigned32 | read-only | IPv4 address of DHCP server address. Note: if an IPv4 address is a.b.c.d then it converts to be (a<<24 + b<<16 + c<<8 + d) |
| U32 dhcpLeasedIpv4Address | 1.3.6.1.4.1.890.1.5.13.13.19.1.20 | Unsigned32 | read-only | The leased IPv4 address from a DHCP server Note: if an IPv4 address is a.b.c.d then it converts to be (a<<24 + b<<16 + c<<8 + d) |
| U32 dhcpIfIndex | 1.3.6.1.4.1.890.1.5.13.13.19.1.21 | Unsigned32 | read-only | The DHCP client inteface |
| U32 currBondingIfIndex | 1.3.6.1.4.1.890.1.5.13.13.19.1.22 | Unsigned32 | read-only | The current bonding ifIndex which a DSL port joined. Value starts from DSL max port plus 1 |
| U32 lastBondingIfIndex | 1.3.6.1.4.1.890.1.5.13.13.19.1.23 | Unsigned32 | read-only | The last bonding ifIndex which a DSL port joined. Value starts from DSL max port plus 1 |
| IAN sysRestartEventType | 1.3.6.1.4.1.890.1.5.13.13.19.1.24 | IANAItuEventType | not-accessible | The variable describes the event that caused system restart. |
| INT sysRestartProbableCause | 1.3.6.1.4.1.890.1.5.13.13.19.1.25 | INTEGER | not-accessible | The variable describes the probable cause that caused system restart. Below probable cause shall be implemented accordingly. sysResetCause is '1' (hardware related) and if sysRestartErrorCode is 1: power input missing - powerProblem (58) 2: hardware watchdog triggered - processorProblems (535) 3: overheat triggered - highTemperature (123) 4: maintenance button pressed > 8 seconds - maunal (1025) sysResetCause is '2' (software related) and if sysRestartCode is 1: triggered by software watchdog - softwareProgramError (546) 2: restart caused by program exception (additional context stored for reference) - softwareError (163) 3: restart caused by software program intentionally - softwareError (163). sysResetCause is '3' (operation related) and if sysRestartErrorCode is 1: operator press maintenance button 7 seconds - maintenance (1026) 2: operator reset manually (either by SNMP or CLI command) - manual (1025) 3: firmware upgrade - sfwrDownloadFailure (156) |
| INT slotModuleId | 1.3.6.1.4.1.890.1.5.13.13.19.1.27 | INTEGER | read-only | Slot ID |
| IAN iesIANAEventType | 1.3.6.1.4.1.890.1.5.13.13.19.1.28 | IANAItuEventType | read-only | An object to indicate that trap belongs to which IANA event type. |
| IAN iesIANAProbableCause | 1.3.6.1.4.1.890.1.5.13.13.19.1.29 | IANAItuProbableCause | read-only | An object to indicate that trap belongs to which IANA problem cause. Below probable causes shall be supported: 1: power input missing - powerProblem (58) 2: hardware watchdog triggered - processorProblems (535) 3: overheat triggered - highTemperature (123) 4: maintenance button pressed > 8 seconds - maunal (1025) 5: triggered by software watchdog - softwareProgramError (546) 6: restart caused by program exception (additional context stored for reference) - softwareError (163) 7: restart caused by software program intentionally - softwareError (163). 8: operator press HW reset button - maintenance (1026) 9: operator reset manually (either by SNMP or CLI command) - manual (1025) 10: firmware upgrade - sfwrDownloadFailure (156) |
| U32 sysMoaIssuedLoad | 1.3.6.1.4.1.890.1.5.13.13.19.1.30 | Unsigned32 | not-accessible | Memory analyzed utilization when memory overload alarm is issued. |
| INT gponOntId | 1.3.6.1.4.1.890.1.5.13.13.19.1.31 | INTEGER | read-only | gpon ont ID |
| INT gponOntCardId | 1.3.6.1.4.1.890.1.5.13.13.19.1.32 | INTEGER | read-only | gpon ont card ID |
| INT gponOntCardPortId | 1.3.6.1.4.1.890.1.5.13.13.19.1.33 | INTEGER | read-only | gpon ont card port ID |
| INT gponMeClassId | 1.3.6.1.4.1.890.1.5.13.13.19.1.34 | INTEGER | read-only | gpon managed entity class value |
| INT gponRogueOntDetectStatusEx | 1.3.6.1.4.1.890.1.5.13.13.19.1.35 | INTEGER | read-only | Below is the status of rouge ont detection: 1: start rogue detection 2: stop rogue detection 3: detect rogue exist 4: rogue ont does not exist 5: discover rogue ont |
| STR gponOntSerialNumber | 1.3.6.1.4.1.890.1.5.13.13.19.1.36 | DisplayString | not-accessible | The serial number of ont |
| STR gponOntPassword | 1.3.6.1.4.1.890.1.5.13.13.19.1.37 | DisplayString | not-accessible | The password of ont |
| STR gponUserName | 1.3.6.1.4.1.890.1.5.13.13.19.1.38 | DisplayString | not-accessible | User name |
| INT gponMacSubSlotId | 1.3.6.1.4.1.890.1.5.13.13.19.1.39 | INTEGER | read-only | gpon MAC subslot ID |
| INT mstpInstanceId | 1.3.6.1.4.1.890.1.5.13.13.19.1.40 | INTEGER | read-only | mstp instance number |
| INT gponOntMacAntiSpoofOrig | 1.3.6.1.4.1.890.1.5.13.13.19.1.41 | INTEGER | not-accessible | The original gpon ont ID of Mac-AntiSpoofing. |
| INT gponOntMacAntiSpoofNew | 1.3.6.1.4.1.890.1.5.13.13.19.1.42 | INTEGER | not-accessible | The new gpon ont ID of Mac-AntiSpoofing. |
| INT gponOntMacAntiSpoofMAC | 1.3.6.1.4.1.890.1.5.13.13.19.1.43 | INTEGER | not-accessible | The gpon ont MAC of Mac-AntiSpoofing. |
| dsltrap | 1.3.6.1.4.1.890.1.5.13.13.19.2 | |||
| NTF xdslLinkDown | 1.3.6.1.4.1.890.1.5.13.13.19.2.1 | The trap signifies one dsl port is linked down. | ||
| NTF xdslLinkUp | 1.3.6.1.4.1.890.1.5.13.13.19.2.2 | The trap signifies one dsl port is linked up. | ||
| NTF xdslXtucLof | 1.3.6.1.4.1.890.1.5.13.13.19.2.3 | The trap signifies XTU-C Loss of Framing. | ||
| NTF xdslXtucLos | 1.3.6.1.4.1.890.1.5.13.13.19.2.4 | The trap signifies XTU-C Loss of Signal. | ||
| NTF xdslXturLof | 1.3.6.1.4.1.890.1.5.13.13.19.2.5 | The trap signifies XTU-R Loss of Framing. | ||
| NTF xdslXturLos | 1.3.6.1.4.1.890.1.5.13.13.19.2.6 | The trap signifies XTU-R Loss of Signal. | ||
| NTF xdslXturLpr | 1.3.6.1.4.1.890.1.5.13.13.19.2.7 | The trap signifies XTU-R Loss of Power. | ||
| NTF xdslXtucLofClear | 1.3.6.1.4.1.890.1.5.13.13.19.2.8 | The trap signifies XTU-C Loss of Framing is cleared. | ||
| NTF xdslXtucLosClear | 1.3.6.1.4.1.890.1.5.13.13.19.2.9 | The trap signifies XTU-C Loss of Signal is cleared. | ||
| NTF xdslXturLofClear | 1.3.6.1.4.1.890.1.5.13.13.19.2.10 | The trap signifies XTU-R Loss of Framing is cleared. | ||
| NTF xdslXturLosClear | 1.3.6.1.4.1.890.1.5.13.13.19.2.11 | The trap signifies XTU-R Loss of Signal is cleared. | ||
| NTF xdslXturLprClear | 1.3.6.1.4.1.890.1.5.13.13.19.2.12 | The trap signifies XTU-R Loss of Power is cleared. | ||
| NTF xdslDspDownloadFail | 1.3.6.1.4.1.890.1.5.13.13.19.2.15 | The trap signifies DSL modem code download failed. | ||
| NTF xdslDspDownloadFailClear | 1.3.6.1.4.1.890.1.5.13.13.19.2.16 | The trap signifies DSL modem code download fail is cleared. | ||
| NTF xdslDspInoperable | 1.3.6.1.4.1.890.1.5.13.13.19.2.17 | The trap signifies a DSL chip failure due to modem code download faied for 10 times. | ||
| equipment | 1.3.6.1.4.1.890.1.5.13.13.19.3 | |||
| NTF hwMonitorFail | 1.3.6.1.4.1.890.1.5.13.13.19.3.1 | Hardware monitor itself diagnosis is failed. | ||
| NTF voltageOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.3.2 | Send a message to notify the manager that the voltage of the system is out of range. The variable in the binding list is the current voltage in volt of the system. | ||
| NTF voltageNormal | 1.3.6.1.4.1.890.1.5.13.13.19.3.3 | Send a message to notify the manager that the low-voltage condition is over. The variable in the binding list is the current voltage in volt of the system. | ||
| NTF temperatureOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.3.4 | Send a message to notify the manager that the temperature of the system is out of range. The variable in the binding list is the current temperature in Celsius of the system. | ||
| NTF temperatureNormal | 1.3.6.1.4.1.890.1.5.13.13.19.3.5 | Send a message to notify the manager that temperature is back to normal (temperature_out_of_range condition disappeared). The variable in the binding list is the current temperature in Celsius of the system. | ||
| NTF fanRpmOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.3.6 | Send a message to notify the manager that the rpm of the fan is out of range. The variable in the binding list is the current rpm of the fan. | ||
| NTF fanRpmNormal | 1.3.6.1.4.1.890.1.5.13.13.19.3.7 | Send a message to notify the manager that the out-of-range condition of the fan is over. The variable in the binding list is the current rpm of the fan. | ||
| NTF hwRtcFail | 1.3.6.1.4.1.890.1.5.13.13.19.3.8 | Send a message to notify the manager that the hardware RTC is failed. | ||
| NTF extAlarmInput1Trigger | 1.3.6.1.4.1.890.1.5.13.13.19.3.9 | The trap signifies that the external alarm input 1 of MSC card is triggered. | ||
| NTF extAlarmInput1Release | 1.3.6.1.4.1.890.1.5.13.13.19.3.10 | The trap signifies that the external alarm input 1 of MSC card is released. | ||
| NTF extAlarmInput2Trigger | 1.3.6.1.4.1.890.1.5.13.13.19.3.11 | The trap signifies that the external alarm input 2 of MSC card is triggered. | ||
| NTF extAlarmInput2Release | 1.3.6.1.4.1.890.1.5.13.13.19.3.12 | The trap signifies that the external alarm input 2 of MSC card is released. | ||
| NTF extAlarmInput3Trigger | 1.3.6.1.4.1.890.1.5.13.13.19.3.13 | The trap signifies that the external alarm input 3 of MSC card is triggered. | ||
| NTF extAlarmInput3Release | 1.3.6.1.4.1.890.1.5.13.13.19.3.14 | The trap signifies that the external alarm input 3 of MSC card is released. | ||
| NTF extAlarmInput4Trigger | 1.3.6.1.4.1.890.1.5.13.13.19.3.15 | The trap signifies that the external alarm input 4 of MSC card is triggered. | ||
| NTF extAlarmInput4Release | 1.3.6.1.4.1.890.1.5.13.13.19.3.16 | The trap signifies that the external alarm input 4 of MSC card is released. | ||
| NTF extAlarmInput5Trigger | 1.3.6.1.4.1.890.1.5.13.13.19.3.17 | The trap signifies that the external alarm input 5 of MSC card is triggered. | ||
| NTF extAlarmInput5Release | 1.3.6.1.4.1.890.1.5.13.13.19.3.18 | The trap signifies that the external alarm input 5 of MSC card is released. | ||
| NTF extAlarmInput6Trigger | 1.3.6.1.4.1.890.1.5.13.13.19.3.19 | The trap signifies that the external alarm input 6 of MSC card is triggered. | ||
| NTF extAlarmInput6Release | 1.3.6.1.4.1.890.1.5.13.13.19.3.20 | The trap signifies that the external alarm input 6 of MSC card is released. | ||
| NTF extAlarmInput7Trigger | 1.3.6.1.4.1.890.1.5.13.13.19.3.21 | The trap signifies that the external alarm input 7 of MSC card is triggered. | ||
| NTF extAlarmInput7Release | 1.3.6.1.4.1.890.1.5.13.13.19.3.22 | The trap signifies that the external alarm input 7 of MSC card is released. | ||
| NTF extAlarmInput8Trigger | 1.3.6.1.4.1.890.1.5.13.13.19.3.23 | The trap signifies that the external alarm input 8 of MSC card is triggered. | ||
| NTF extAlarmInput8Release | 1.3.6.1.4.1.890.1.5.13.13.19.3.24 | The trap signifies that the external alarm input 8 of MSC card is released. | ||
| NTF power1NotExist | 1.3.6.1.4.1.890.1.5.13.13.19.3.29 | The trap signifies power 1 not detected. | ||
| NTF power1NotExistClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.30 | The trap signifies power 1 detected. | ||
| NTF power2NotExist | 1.3.6.1.4.1.890.1.5.13.13.19.3.31 | The trap signifies power 2 not detected. | ||
| NTF power2NotExistClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.32 | The trap signifies power 2 detected. | ||
| NTF power1VoltageFail | 1.3.6.1.4.1.890.1.5.13.13.19.3.33 | The trap signifies power 1 voltage fail. | ||
| NTF power1VoltageFailClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.34 | The trap signifies power 1 voltage is cleared. | ||
| NTF power2VoltageFail | 1.3.6.1.4.1.890.1.5.13.13.19.3.35 | The trap signifies power 2 voltage fail. | ||
| NTF power2VoltageFailClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.36 | The trap signifies power 2 voltage is cleared. | ||
| NTF modulePlugIn | 1.3.6.1.4.1.890.1.5.13.13.19.3.37 | A modulePlugIn trap signifies that the sending protocol entity recognizes that one module is plugged into the device. | ||
| NTF modulePullOut | 1.3.6.1.4.1.890.1.5.13.13.19.3.38 | A modulePullOut trap signifies that the sending protocol entity recognizes one module is pulled out from the device. | ||
| NTF moduleUp | 1.3.6.1.4.1.890.1.5.13.13.19.3.39 | A moduleUp trap signifies that the sending protocol entity recognizes that one of the modules represented in the agent's configuration has come up. | ||
| NTF moduleDown | 1.3.6.1.4.1.890.1.5.13.13.19.3.40 | A moduleDown trap signifies that the sending protocol entity recognizes a failure in one of the modules represented in the agent's configuration. | ||
| NTF moduleDisable | 1.3.6.1.4.1.890.1.5.13.13.19.3.41 | The trap signifies user disables one module. | ||
| NTF moduleInvalid | 1.3.6.1.4.1.890.1.5.13.13.19.3.43 | The trap signifies invalid modlue detected. | ||
| NTF moduleInvalidClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.44 | The trap signifies invalid modlue is cleared. | ||
| NTF timerefSync | 1.3.6.1.4.1.890.1.5.13.13.19.3.45 | The system receive timing reference signal correctly. The varable in the binding list is current reference. | ||
| NTF timerefNoSync | 1.3.6.1.4.1.890.1.5.13.13.19.3.46 | The system receive timing reference signal incorrectly. The varable in the binding list is last reference. | ||
| NTF timerefPresent | 1.3.6.1.4.1.890.1.5.13.13.19.3.47 | The system received timing reference signal. | ||
| NTF timerefNoPresent | 1.3.6.1.4.1.890.1.5.13.13.19.3.48 | The system does not receive timing reference signal. | ||
| NTF timerefToDSync | 1.3.6.1.4.1.890.1.5.13.13.19.3.49 | The system receives ToD sentence correctly. | ||
| NTF timerefToDNoSync | 1.3.6.1.4.1.890.1.5.13.13.19.3.50 | The system does not receive ToD sentence correctly. | ||
| NTF timerefChipFail | 1.3.6.1.4.1.890.1.5.13.13.19.3.51 | The system can not access clock synchronize chip correctly. | ||
| NTF moduleWrongFwVer | 1.3.6.1.4.1.890.1.5.13.13.19.3.52 | rddn-msc wrong fwVersion,skip provision | ||
| NTF moduleSwitchOver | 1.3.6.1.4.1.890.1.5.13.13.19.3.53 | rddn-msc switch over | ||
| NTF equipmentCpuOverload | 1.3.6.1.4.1.890.1.5.13.13.19.3.54 | Signifies equipment cpu is overload. | ||
| NTF equipmentCpuOverloadClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.55 | Signifies equipment cpu overload is cleared. | ||
| NTF acDown | 1.3.6.1.4.1.890.1.5.13.13.19.3.56 | The trap signifies AC power is down. | ||
| NTF acDownClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.57 | The trap signifies AC down alarm is cleared. | ||
| NTF battTempOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.3.58 | The trap signifies battery temperature is out of range. | ||
| NTF battTempOutOfRangeClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.59 | The trap signifies battery temperature out of range alarm is cleared. | ||
| NTF battVoltageLow | 1.3.6.1.4.1.890.1.5.13.13.19.3.60 | The trap signifies battery voltage is under the threshold. | ||
| NTF battVoltageLowClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.61 | The trap signifies battery voltage low alarm is cleared. | ||
| NTF battVoltageCritic | 1.3.6.1.4.1.890.1.5.13.13.19.3.62 | The trap signifies battery voltage is under the threshold. | ||
| NTF battVoltageCriticClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.63 | The trap signifies battery voltage critical alarm is cleared. | ||
| NTF battVoltageError | 1.3.6.1.4.1.890.1.5.13.13.19.3.64 | The trap signifies the battery voltage is too low to be charged. | ||
| NTF battVoltageErrorClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.65 | The trap signifies battery voltage error alarm is cleared. | ||
| NTF battAbsent | 1.3.6.1.4.1.890.1.5.13.13.19.3.66 | The trap signifies no battery is detected. | ||
| NTF battAbsentClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.67 | The trap signifies battery absent alarm is cleared. | ||
| NTF currentFault | 1.3.6.1.4.1.890.1.5.13.13.19.3.68 | The trap signifies charge current exceed the threshold. | ||
| NTF currentFaultClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.69 | The trap signifies charge current fault alarm is cleared. | ||
| NTF chargeOvertime | 1.3.6.1.4.1.890.1.5.13.13.19.3.70 | The trap signifies charge overtime. | ||
| NTF chargeOvertimeClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.71 | The trap signifies charge overtime is cleared. | ||
| NTF battInfoInvalid | 1.3.6.1.4.1.890.1.5.13.13.19.3.72 | The trap signifies battery capacity invalid. | ||
| NTF battInfoInvalidClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.73 | The trap signifies battery capacity invalid is cleared. | ||
| NTF noThermal | 1.3.6.1.4.1.890.1.5.13.13.19.3.74 | The trap signifies no thermal sensor connected. | ||
| NTF noThermalClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.75 | The trap signifies no thermal sensor connected is cleared. | ||
| NTF power1Overheat | 1.3.6.1.4.1.890.1.5.13.13.19.3.76 | The trap signifies power 1 overheat. | ||
| NTF power1OverheatClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.77 | The trap signifies power 1 overheat is cleared. | ||
| NTF power2Overheat | 1.3.6.1.4.1.890.1.5.13.13.19.3.78 | The trap signifies power 2 overheat. | ||
| NTF power2OverheatClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.79 | The trap signifies power 2 overheat is cleared. | ||
| NTF power1LmSensorFault | 1.3.6.1.4.1.890.1.5.13.13.19.3.80 | The trap signifies power 1 LM5064 senseor fault. | ||
| NTF power1LmSensorFaultClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.81 | The trap signifies power 1 LM5064 senseor fault is cleared. | ||
| NTF power2LmSensorFault | 1.3.6.1.4.1.890.1.5.13.13.19.3.82 | The trap signifies power 2 LM5064 senseor fault. | ||
| NTF power2LmSensorFaultClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.83 | The trap signifies power 2 LM5064 senseor fault is cleared. | ||
| NTF dcDown | 1.3.6.1.4.1.890.1.5.13.13.19.3.84 | The trap signifies DC power is down. | ||
| NTF dcDownClear | 1.3.6.1.4.1.890.1.5.13.13.19.3.85 | The trap signifies DC down alarm is cleared. | ||
| systrap | 1.3.6.1.4.1.890.1.5.13.13.19.4 | |||
| NTF sysMacAntiSpoofing | 1.3.6.1.4.1.890.1.5.13.13.19.4.1 | MAC anti-spoofing happened. | ||
| NTF sysAlarmClearEnable | 1.3.6.1.4.1.890.1.5.13.13.19.4.2 | Alarm clear is activated. | ||
| NTF sysLoginFailure | 1.3.6.1.4.1.890.1.5.13.13.19.4.3 | User login is failed. | ||
| NTF reboot | 1.3.6.1.4.1.890.1.5.13.13.19.4.4 | Send a message to the manager that the system is going to shutdown. The variable is the reason that causes the system to shutdown. Note: this notification should be sent before rebooting. | ||
| NTF cpuOverload | 1.3.6.1.4.1.890.1.5.13.13.19.4.5 | Signifies cpu is overload. | ||
| NTF cpuOverloadClear | 1.3.6.1.4.1.890.1.5.13.13.19.4.6 | Signifies cpu overload is cleared. | ||
| NTF cfgUploadFail | 1.3.6.1.4.1.890.1.5.13.13.19.4.7 | Signifies configuration file uploading to EMS failed. | ||
| NTF cfgReloadFail | 1.3.6.1.4.1.890.1.5.13.13.19.4.8 | Signifies configuration file reload from FLASH failed. | ||
| NTF writeFlashFail | 1.3.6.1.4.1.890.1.5.13.13.19.4.9 | Signifies writing to flash failed. | ||
| NTF mfgDataFail | 1.3.6.1.4.1.890.1.5.13.13.19.4.10 | Signifies invalid manufacturing data. | ||
| NTF swDownloadNotification | 1.3.6.1.4.1.890.1.5.13.13.19.4.18 | Signifies SW image downloading/installing/restoring/reverting status. | ||
| NTF cfgChangeNotification | 1.3.6.1.4.1.890.1.5.13.13.19.4.19 | Signifies configuration change from CLI command. | ||
| NTF dhcpLeasedNotification | 1.3.6.1.4.1.890.1.5.13.13.19.4.20 | To indicate the system complete DHCP lease process. The variable bindings are: 1) 1: inband management interface; 2: reserved management interface(unused). 2) the IP address of DHCP server. 3) the IP address leased from DHCP server. | ||
| NTF sysRestartNotification | 1.3.6.1.4.1.890.1.5.13.13.19.4.21 | This is a trap to unify system restart trap definition. The standard ones ('warm start' and 'cold start') are no longer supported. 1) sysBootupFwVersion: the system happened restart with booting up firmware version. 2) sysRestartCause: what reason caused system restart. 3) sysRestartErrorCode: if this is a restart caused by software problem then error code is specified. '0': is specified is not related to software. | ||
| NTF dhcpLeasedFailNotification | 1.3.6.1.4.1.890.1.5.13.13.19.4.22 | To indicate the system failed to complete DHCP lease process on management interface. The variable bindings are: 1) 1: inband management interface; 2: reserved management interface(unused). | ||
| NTF dhcpLeasedFailNotificationClear | 1.3.6.1.4.1.890.1.5.13.13.19.4.23 | Clear dhcpLeasedFailNotification. The variable bindings are: 1) 1: inband management interface; 2: reserved management interface(unused). | ||
| NTF loopguard | 1.3.6.1.4.1.890.1.5.13.13.19.4.24 | The trap signifies loop is detected by ifIndex. The detected loop is between ifIndex and loopguardSenderIfIndex. | ||
| NTF loopguardClear | 1.3.6.1.4.1.890.1.5.13.13.19.4.25 | The trap signifies loop in ifIndex is cleared. | ||
| NTF htPortPolicer | 1.3.6.1.4.1.890.1.5.13.13.19.4.26 | The trap signifies host termination attack is detected in ifIndex. | ||
| NTF sysAlarmCutoffEnable | 1.3.6.1.4.1.890.1.5.13.13.19.4.27 | Alarm cutoff is activated. | ||
| NTF memoryOverload | 1.3.6.1.4.1.890.1.5.13.13.19.4.28 | Signifies memory is overload. | ||
| NTF memoryOverloadClear | 1.3.6.1.4.1.890.1.5.13.13.19.4.29 | Signifies memory overload is cleared. | ||
| NTF macTableFull | 1.3.6.1.4.1.890.1.5.13.13.19.4.30 | Signifies MAC forwarding table full. | ||
| NTF macTableFullClear | 1.3.6.1.4.1.890.1.5.13.13.19.4.31 | Signifies MAC forwarding table full is cleared. | ||
| NTF mstpNewRoot | 1.3.6.1.4.1.890.1.5.13.13.19.4.32 | The newRoot trap indicates that the sending agent has become the new root of the Spanning Tree; the trap is sent by a bridge soon after its election as the new root, e.g., upon expiration of the Topology Change Timer, immediately subsequent to its election. Implementation of this trap is optional. | ||
| NTF mstpTopologyChange | 1.3.6.1.4.1.890.1.5.13.13.19.4.33 | A topologyChange is sent if the topology changed of MSTP has detected. | ||
| NTF fwChange | 1.3.6.1.4.1.890.1.5.13.13.19.4.34 | A fw_change is sent if the firmware changed of system has detected. | ||
| NTF reloadCfg | 1.3.6.1.4.1.890.1.5.13.13.19.4.35 | Signifies configuration reload from CLI command. | ||
| NTF sysLoginSuccess | 1.3.6.1.4.1.890.1.5.13.13.19.4.36 | User login is OK. | ||
| NTF protectSwitchSuccess | 1.3.6.1.4.1.890.1.5.13.13.19.4.37 | Protect switch success. | ||
| NTF protectSwitchFailed | 1.3.6.1.4.1.890.1.5.13.13.19.4.38 | Protect switch failed. | ||
| getrap | 1.3.6.1.4.1.890.1.5.13.13.19.5 | |||
| NTF geLinkDown | 1.3.6.1.4.1.890.1.5.13.13.19.5.1 | The trap signifies one ethernet port is linked down. | ||
| NTF geLinkUp | 1.3.6.1.4.1.890.1.5.13.13.19.5.2 | The trap signifies one ethernet port is linked up. | ||
| NTF geSfpCurrentTca | 1.3.6.1.4.1.890.1.5.13.13.19.5.4 | The trap signifies SFP module is over current threshold. | ||
| NTF geSfpVoltageTca | 1.3.6.1.4.1.890.1.5.13.13.19.5.5 | The trap signifies SFP module is over voltage threshold. | ||
| NTF geSfpTemperatureTca | 1.3.6.1.4.1.890.1.5.13.13.19.5.6 | The trap signifies SFP module is over temperature threshold. | ||
| NTF geSfpTxPowerTca | 1.3.6.1.4.1.890.1.5.13.13.19.5.7 | The trap signifies SFP module is over TX power threshold. | ||
| NTF geSfpRxPowerTca | 1.3.6.1.4.1.890.1.5.13.13.19.5.8 | The trap signifies SFP module is over RX power threshold. | ||
| NTF geSfpCurrentTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.5.9 | The trap signifies SFP module is over current threshold cleared. | ||
| NTF geSfpVoltageTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.5.10 | The trap signifies SFP module is over voltage threshold cleared. | ||
| NTF geSfpTemperatureTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.5.11 | The trap signifies SFP module is over temperature threshold cleared. | ||
| NTF geSfpTxPowerTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.5.12 | The trap signifies SFP module is over TX power threshold cleared. | ||
| NTF geSfpRxPowerTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.5.13 | The trap signifies SFP module is over RX power threshold cleared. | ||
| gbondtrap | 1.3.6.1.4.1.890.1.5.13.13.19.7 | |||
| NTF gbondLinkDown | 1.3.6.1.4.1.890.1.5.13.13.19.7.1 | The trap signifies one gbond interface port link down. The 'ifIndex' is bonding interface index. | ||
| NTF gbondLinkUp | 1.3.6.1.4.1.890.1.5.13.13.19.7.2 | The trap signifies one gbond interface port linked up. The 'ifIndex' is bonding interface index. | ||
| gpontrap | 1.3.6.1.4.1.890.1.5.13.13.19.8 | |||
| NTF gponOntLos | 1.3.6.1.4.1.890.1.5.13.13.19.8.1 | The trap signifies ont is loss of signal. | ||
| NTF gponOntLosClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.2 | The trap signifies ont is loss of signal cleared. | ||
| NTF gponOntLof | 1.3.6.1.4.1.890.1.5.13.13.19.8.3 | The trap signifies ont is loss of frame. | ||
| NTF gponOntLofClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.4 | The trap signifies ont is loss of frame cleared. | ||
| NTF gponOntPloam | 1.3.6.1.4.1.890.1.5.13.13.19.8.5 | The trap signifies ont is loss of PLOAM. | ||
| NTF gponOntPloamClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.6 | The trap signifies ont is loss of PLOAM cleared. | ||
| NTF gponOntLcdg | 1.3.6.1.4.1.890.1.5.13.13.19.8.7 | The trap signifies ont is loss of GEM channel delineation. | ||
| NTF gponOntLcdgClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.8 | The trap signifies ont is loss of GEM channel delineation cleared. | ||
| NTF gponOntRdi | 1.3.6.1.4.1.890.1.5.13.13.19.8.9 | The trap signifies ont is remote defect indication. | ||
| NTF gponOntRdiClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.10 | The trap signifies ont is remote defect indication cleared. | ||
| NTF gponOntSuf | 1.3.6.1.4.1.890.1.5.13.13.19.8.11 | The trap signifies ont is startup failure. | ||
| NTF gponOntSufClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.12 | The trap signifies ont is startup failure cleared. | ||
| NTF gponOntLoa | 1.3.6.1.4.1.890.1.5.13.13.19.8.13 | The trap signifies ont is loss of acknowledge. | ||
| NTF gponOntLoaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.14 | The trap signifies ont is loss of acknowledge cleared. | ||
| NTF gponOntDg | 1.3.6.1.4.1.890.1.5.13.13.19.8.15 | The trap signifies ont receives dying-gasp. | ||
| NTF gponOntDgClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.16 | The trap signifies ont receives dying-gasp cleared. | ||
| NTF gponOntDf | 1.3.6.1.4.1.890.1.5.13.13.19.8.17 | The trap signifies ont deactivates failure. | ||
| NTF gponOntDfClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.18 | The trap signifies ont deactivates failure cleared. | ||
| NTF gponOntDow | 1.3.6.1.4.1.890.1.5.13.13.19.8.19 | The trap signifies ont is drift of window. | ||
| NTF gponOntDowClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.20 | The trap signifies ont is drift of window cleared. | ||
| NTF gponOntTiw | 1.3.6.1.4.1.890.1.5.13.13.19.8.21 | The trap signifies ont is transmission interference warning. | ||
| NTF gponOntTiwClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.22 | The trap signifies ont is transmission interference warning cleared. | ||
| NTF gponOntSf | 1.3.6.1.4.1.890.1.5.13.13.19.8.23 | The trap signifies ont is signal fail. | ||
| NTF gponOntSfClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.24 | The trap signifies ont is signal fail cleared. | ||
| NTF gponOntSd | 1.3.6.1.4.1.890.1.5.13.13.19.8.25 | The trap signifies ont is signal degraded. | ||
| NTF gponOntSdClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.26 | The trap signifies ont is signal degraded cleared. | ||
| NTF gponOntLok | 1.3.6.1.4.1.890.1.5.13.13.19.8.27 | The trap signifies ont is loss of key synch. | ||
| NTF gponOntLokClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.28 | The trap signifies ont is loss of key synch cleared. | ||
| NTF gponOntFecCorrByte | 1.3.6.1.4.1.890.1.5.13.13.19.8.29 | The trap signifies ont is FEC corrected byte. | ||
| NTF gponOntFecCorrByteClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.30 | The trap signifies ont is FEC corrected byte cleared. | ||
| NTF gponOntFecCorrCw | 1.3.6.1.4.1.890.1.5.13.13.19.8.31 | The trap signifies ont is FEC corrected code word. | ||
| NTF gponOntFecCorrCwClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.32 | The trap signifies ont is FEC corrected code word cleared. | ||
| NTF gponOntFecUnCorrCw | 1.3.6.1.4.1.890.1.5.13.13.19.8.33 | The trap signifies ont is FEC uncorrected code word. | ||
| NTF gponOntFecUnCorrCwClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.34 | The trap signifies ont is FEC uncorrected code word cleared. | ||
| NTF gponOntTcaBip | 1.3.6.1.4.1.890.1.5.13.13.19.8.35 | The trap signifies ont is bit interleaved parity. | ||
| NTF gponOntTcaBipClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.36 | The trap signifies ont is bit interleaved parity cleared. | ||
| NTF gponOntTcaRei | 1.3.6.1.4.1.890.1.5.13.13.19.8.37 | The trap signifies ont is remote error indication. | ||
| NTF gponOntTcaReiClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.38 | The trap signifies ont is remote error indication cleared. | ||
| NTF omciBatteryFailure | 1.3.6.1.4.1.890.1.5.13.13.19.8.67 | Battery is provisioned and present but cannot recharge. | ||
| NTF omciBatteryFailureClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.68 | Battery is provisioned and present but cannot recharge cleared. | ||
| NTF omciBatteryLow | 1.3.6.1.4.1.890.1.5.13.13.19.8.69 | Battery is provisioned and present but its voltage is too low. | ||
| NTF omciBatteryLowClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.70 | Battery is provisioned and present but its voltage is too low cleared. | ||
| NTF omciBatteryMissing | 1.3.6.1.4.1.890.1.5.13.13.19.8.71 | Battery is provisioned but missing. | ||
| NTF omciBatteryMissingClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.72 | Battery is provisioned but missing cleared. | ||
| NTF omciBlockLoss | 1.3.6.1.4.1.890.1.5.13.13.19.8.73 | Content loss in excess of threshold. | ||
| NTF omciBlockLossClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.74 | Content loss in excess of threshold cleared. | ||
| NTF omciCardAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.75 | Card in alarm. | ||
| NTF omciCardAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.76 | Card in alarm cleared. | ||
| NTF omciConFuncFail | 1.3.6.1.4.1.890.1.5.13.13.19.8.87 | Indicates a failure of the connecting function. | ||
| NTF omciConFuncFailClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.88 | Indicates a failure of the connecting function cleared. | ||
| NTF omciDataRateThrDownShift | 1.3.6.1.4.1.890.1.5.13.13.19.8.89 | Data rate threshold downshift. | ||
| NTF omciDataRateThrDownShiftClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.90 | Data rate threshold downshift cleared. | ||
| NTF omciDataRateThrUpShift | 1.3.6.1.4.1.890.1.5.13.13.19.8.91 | Data rate threshold upshift. | ||
| NTF omciDataRateThrUpShiftClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.92 | Data rate threshold upshift cleared. | ||
| NTF omciDeprecated | 1.3.6.1.4.1.890.1.5.13.13.19.8.93 | GEM interworking termination point. | ||
| NTF omciDeprecatedClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.94 | GEM interworking termination point cleared. | ||
| NTF omciDyingGasp | 1.3.6.1.4.1.890.1.5.13.13.19.8.97 | ONU is powering off imminently. | ||
| NTF omciDyingGaspClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.98 | ONU is powering off imminently cleared. | ||
| NTF omciEndToEndLossOfContinuity | 1.3.6.1.4.1.890.1.5.13.13.19.8.99 | Loss of continuity can be detected when the GEM port network CTP supports a GEM interworking termination point. | ||
| NTF omciEndToEndLossOfContinuityClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.100 | Loss of continuity can be detected when the GEM port network CTP supports a GEM interworking termination point cleared. | ||
| NTF omciEqptAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.101 | A failure on an internal interface or failed self-test. | ||
| NTF omciEqptAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.102 | A failure on an internal interface or failed self-test cleared. | ||
| NTF omciFeLossOfFraming | 1.3.6.1.4.1.890.1.5.13.13.19.8.103 | Far-end loss of frame. | ||
| NTF omciFeLossOfFramingClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.104 | Far-end loss of frame cleared. | ||
| NTF omciFeLossOfLink | 1.3.6.1.4.1.890.1.5.13.13.19.8.105 | Far-end loss of link. | ||
| NTF omciFeLossOfLinkClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.106 | Far-end loss of link cleared. | ||
| NTF omciFeLossOfPower | 1.3.6.1.4.1.890.1.5.13.13.19.8.107 | Far-end loss of power. | ||
| NTF omciFeLossOfPowerClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.108 | Far-end loss of power cleared. | ||
| NTF omciFeLossOfSignal | 1.3.6.1.4.1.890.1.5.13.13.19.8.109 | Far-end loss of signal. | ||
| NTF omciFeLossOfSignalClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.110 | Far-end loss of signal cleared. | ||
| NTF omciGfsa | 1.3.6.1.4.1.890.1.5.13.13.19.8.113 | GEM frame starvation alarm. | ||
| NTF omciGfsaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.114 | GEM frame starvation alarm cleared. | ||
| NTF omciHighRxOpticalPower | 1.3.6.1.4.1.890.1.5.13.13.19.8.115 | Received downstream optical power above threshold. | ||
| NTF omciHighRxOpticalPowerClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.116 | Received downstream optical power above threshold cleared. | ||
| NTF omciHighTxOpticalPower | 1.3.6.1.4.1.890.1.5.13.13.19.8.117 | Transmit optical power above upper threshold. | ||
| NTF omciHighTxOpticalPowerClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.118 | Transmit optical power above upper threshold cleared. | ||
| NTF omciImproperCardRemoval | 1.3.6.1.4.1.890.1.5.13.13.19.8.119 | Card has been removed without being deprovisioned. | ||
| NTF omciImproperCardRemovalClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.120 | Card has been removed without being deprovisioned cleared. | ||
| NTF omciLanLos | 1.3.6.1.4.1.890.1.5.13.13.19.8.123 | No carrier at the Ethernet UNI. | ||
| NTF omciLanLosClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.124 | No carrier at the Ethernet UNI cleared. | ||
| NTF omciLaserBiasCur | 1.3.6.1.4.1.890.1.5.13.13.19.8.125 | Laser bias current above threshold determined by vendor; laser end of life pending. | ||
| NTF omciLaserBiasCurClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.126 | Laser bias current above threshold determined by vendor; laser end of life pending cleared. | ||
| NTF omciLaserEndOfLife | 1.3.6.1.4.1.890.1.5.13.13.19.8.127 | Failure of transmit laser imminent. | ||
| NTF omciLaserEndOfLifeClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.128 | Failure of transmit laser imminent cleared. | ||
| NTF omciLineConfigFailure | 1.3.6.1.4.1.890.1.5.13.13.19.8.129 | Line configuration failure. | ||
| NTF omciLineConfigFailureClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.130 | Line configuration failure cleared. | ||
| NTF omciLineInitializationFailure | 1.3.6.1.4.1.890.1.5.13.13.19.8.131 | Line initialization failure. | ||
| NTF omciLineInitializationFailureClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.132 | Line initialization failure cleared. | ||
| NTF omciLowLaserBiasCur | 1.3.6.1.4.1.890.1.5.13.13.19.8.139 | ONU has detected that the laser bias current is less than the configured threshold. | ||
| NTF omciLowLaserBiasCurClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.140 | ONU has detected that the laser bias current is less than the configured threshold cleared. | ||
| NTF omciLowPowerFeedVoltage | 1.3.6.1.4.1.890.1.5.13.13.19.8.141 | ONU has detected that the power feed voltage is less than the configured threshold. | ||
| NTF omciLowPowerFeedVoltageClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.142 | ONU has detected that the power feed voltage is less than the configured threshold cleared. | ||
| NTF omciLowRxOpticalPower | 1.3.6.1.4.1.890.1.5.13.13.19.8.143 | Received downstream optical power below threshold. | ||
| NTF omciLowRxOpticalPowerClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.144 | Received downstream optical power below threshold cleared. | ||
| NTF omciLowTemperature | 1.3.6.1.4.1.890.1.5.13.13.19.8.145 | ONU has detected that the temperature is under the configured threshold. | ||
| NTF omciLowTemperatureClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.146 | ONU has detected that the temperature is under the configured threshold cleared. | ||
| NTF omciLowTxOpticalPower | 1.3.6.1.4.1.890.1.5.13.13.19.8.147 | Transmit optical power below lower threshold. | ||
| NTF omciLowTxOpticalPowerClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.148 | Transmit optical power below lower threshold cleared. | ||
| NTF omciNeLossOfFraming | 1.3.6.1.4.1.890.1.5.13.13.19.8.149 | Near-end loss of frame. | ||
| NTF omciNeLossOfFramingClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.150 | Near-end loss of frame cleared. | ||
| NTF omciNeLossOfLink | 1.3.6.1.4.1.890.1.5.13.13.19.8.151 | Near-end loss of link. | ||
| NTF omciNeLossOfLinkClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.152 | Near-end loss of link cleared. | ||
| NTF omciNeLossOfPower | 1.3.6.1.4.1.890.1.5.13.13.19.8.153 | Near-end loss of power. | ||
| NTF omciNeLossOfPowerClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.154 | Near-end loss of power cleared. | ||
| NTF omciNeLossOfSignal | 1.3.6.1.4.1.890.1.5.13.13.19.8.155 | Near-end loss of signal. | ||
| NTF omciNeLossOfSignalClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.156 | Near-end loss of signal cleared. | ||
| NTF omciOntGTemperatureRed | 1.3.6.1.4.1.890.1.5.13.13.19.8.157 | Some services have been shut down to avoid equipment damage. | ||
| NTF omciOntGTemperatureRedClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.158 | Some services have been shut down to avoid equipment damage cleared. | ||
| NTF omciOntGTemperatureYellow | 1.3.6.1.4.1.890.1.5.13.13.19.8.159 | No service shutdown at present, but the circuit pack is operating beyond its recommended range. | ||
| NTF omciOntGTemperatureYellowClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.160 | No service shutdown at present, but the circuit pack is operating beyond its recommended range cleared. | ||
| NTF omciOntSelfTestFailure | 1.3.6.1.4.1.890.1.5.13.13.19.8.161 | ONU has failed autonomous self-test. | ||
| NTF omciOntSelfTestFailureClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.162 | ONU has failed autonomous self-test cleared. | ||
| NTF omciOnuManualPowerOff | 1.3.6.1.4.1.890.1.5.13.13.19.8.163 | The ONU is shutting down because the subscriber has turned off its power switch. | ||
| NTF omciOnuManualPowerOffClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.164 | The ONU is shutting down because the subscriber has turned off its power switch cleared. | ||
| NTF omciPhysicalIntrusionAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.167 | Applies if the ONU supports detection such as door or box open . | ||
| NTF omciPhysicalIntrusionAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.168 | Applies if the ONU supports detection such as door or box open cleared. | ||
| NTF omciPlugInEqptIdMismatchAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.169 | Applies if the ONU supports detection such as door or box open . | ||
| NTF omciPlugInEqptIdMismatchAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.170 | Applies if the ONU supports detection such as door or box open cleared. | ||
| NTF omciPlugInLimMissingAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.171 | Configured Plug-in LIM is not present. | ||
| NTF omciPlugInLimMissingAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.172 | Configured Plug-in LIM is not present cleared. | ||
| NTF omciPlugInTypeMismatchAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.173 | Inserted Plug-in LIM is wrong type. | ||
| NTF omciPlugInTypeMismatchAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.174 | Inserted Plug-in LIM is wrong type cleared. | ||
| NTF omciPoweringAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.175 | Fuse failure or failure of DC/DC converter. | ||
| NTF omciPoweringAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.176 | Fuse failure or failure of DC/DC converter cleared. | ||
| NTF omciProtectionSwitch | 1.3.6.1.4.1.890.1.5.13.13.19.8.177 | An autonomous equipment protection switch has occurred. | ||
| NTF omciProtectionSwitchClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.178 | An autonomous equipment protection switch has occurred cleared. | ||
| NTF omciSd | 1.3.6.1.4.1.890.1.5.13.13.19.8.185 | Bit error-based signal degrade. | ||
| NTF omciSdClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.186 | Bit error-based signal degrade cleared. | ||
| NTF omciSelfTestFailure | 1.3.6.1.4.1.890.1.5.13.13.19.8.187 | Failure of circuit pack autonomous self-test. | ||
| NTF omciSelfTestFailureClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.188 | Failure of circuit pack autonomous self-test cleared. | ||
| NTF omciSf | 1.3.6.1.4.1.890.1.5.13.13.19.8.189 | Bit error-based signal fail. | ||
| NTF omciSfClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.190 | Bit error-based signal fail cleared. | ||
| NTF omciSipUdRegAuth | 1.3.6.1.4.1.890.1.5.13.13.19.8.205 | Cannot authenticate a registration session. | ||
| NTF omciSipUdRegAuthClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.206 | Cannot authenticate a registration session cleared. | ||
| NTF omciSipUdRegFail | 1.3.6.1.4.1.890.1.5.13.13.19.8.207 | Failure response received from a registration server. | ||
| NTF omciSipUdRegFailClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.208 | Failure response received from a registration server cleared. | ||
| NTF omciSipUdRegTimeout | 1.3.6.1.4.1.890.1.5.13.13.19.8.209 | Timeout waiting for response from a registration server. | ||
| NTF omciSipUdRegTimeoutClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.210 | Timeout waiting for response from a registration server cleared. | ||
| NTF omciTcaAlignErrorCount | 1.3.6.1.4.1.890.1.5.13.13.19.8.213 | Received frames that were not an integral number of octets in length and did not pass the FCS check. | ||
| NTF omciTcaAlignErrorCountClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.214 | Received frames that were not an integral number of octets in length and did not pass the FCS check cleared. | ||
| NTF omciTcaBridgeLearningEntryDiscard | 1.3.6.1.4.1.890.1.5.13.13.19.8.217 | Forwarding database entries that have been or would have been learned but were discarded or replaced due to a lack of space in the database table. | ||
| NTF omciTcaBridgeLearningEntryDiscardClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.218 | Forwarding database entries that have been or would have been learned but were discarded or replaced due to a lack of space in the database table cleared. | ||
| NTF omciTcaBufOverflowsRx | 1.3.6.1.4.1.890.1.5.13.13.19.8.221 | The number of times that the receive buffer overflowed. | ||
| NTF omciTcaBufOverflowsRxClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.222 | The number of times that the receive buffer overflowed cleared. | ||
| NTF omciTcaBufOverflowsTx | 1.3.6.1.4.1.890.1.5.13.13.19.8.223 | The number of times that the transmit buffer overflowed. | ||
| NTF omciTcaBufOverflowsTxClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.224 | The number of times that the transmit buffer overflowed cleared. | ||
| NTF omciTcaCarrierSenseErrorCount | 1.3.6.1.4.1.890.1.5.13.13.19.8.227 | The number of times that carrier sense was lost or never asserted when attempting to transmit a frame. | ||
| NTF omciTcaCarrierSenseErrorCountClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.228 | The number of times that carrier sense was lost or never asserted when attempting to transmit a frame cleared. | ||
| NTF omciTcaDeferredTx | 1.3.6.1.4.1.890.1.5.13.13.19.8.239 | First transmission attempt was delayed because the medium was busy. | ||
| NTF omciTcaDeferredTxClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.240 | First transmission attempt was delayed because the medium was busy cleared. | ||
| NTF omciTcaDelayExceededDiscard | 1.3.6.1.4.1.890.1.5.13.13.19.8.241 | Frames discarded on this port because transmission was delayed. | ||
| NTF omciTcaDelayExceededDiscardClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.242 | Frames discarded on this port because transmission was delayed cleared. | ||
| NTF omciTcaDropEvents | 1.3.6.1.4.1.890.1.5.13.13.19.8.245 | The total number of events in which packets were dropped due to a lack of resources. | ||
| NTF omciTcaDropEventsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.246 | The total number of events in which packets were dropped due to a lack of resources cleared. | ||
| NTF omciTcaEncryptionKeyErrors | 1.3.6.1.4.1.890.1.5.13.13.19.8.249 | GEM frames with erroneous encryption key indexes. | ||
| NTF omciTcaEncryptionKeyErrorsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.250 | GEM frames with erroneous encryption key indexes cleared. | ||
| NTF omciTcaEthFrameDsCrcErroredPackets | 1.3.6.1.4.1.890.1.5.13.13.19.8.255 | The total number of error packets received on downstream. | ||
| NTF omciTcaEthFrameDsCrcErroredPacketsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.256 | The total number of error packets received on downstream cleared. | ||
| NTF omciTcaEthFrameDsDropEvents | 1.3.6.1.4.1.890.1.5.13.13.19.8.257 | The total number of events in which frames were dropped due to a lack of resources on downstream. | ||
| NTF omciTcaEthFrameDsDropEventsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.258 | The total number of events in which frames were dropped due to a lack of resources on downstream cleared. | ||
| NTF omciTcaEthFrameDsOversizePackets | 1.3.6.1.4.1.890.1.5.13.13.19.8.259 | The total number of packets received that were longer than 1518 octets on downstream. | ||
| NTF omciTcaEthFrameDsOversizePacketsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.260 | The total number of packets received that were longer than 1518 octets on downstream cleared. | ||
| NTF omciTcaEthFrameDsUndersizePackets | 1.3.6.1.4.1.890.1.5.13.13.19.8.261 | The total number of packets received that were less than 64 octets long on downstream. | ||
| NTF omciTcaEthFrameDsUndersizePacketsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.262 | The total number of packets received that were less than 64 octets long on downstream cleared. | ||
| NTF omciTcaEthFrameUsCrcErroredPackets | 1.3.6.1.4.1.890.1.5.13.13.19.8.263 | The total number of error packets received on upstream. | ||
| NTF omciTcaEthFrameUsCrcErroredPacketsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.264 | The total number of error packets received on upstream cleared. | ||
| NTF omciTcaEthFrameUsDropEvents | 1.3.6.1.4.1.890.1.5.13.13.19.8.265 | The total number of events in which frames were dropped due to a lack of resources on upstream. | ||
| NTF omciTcaEthFrameUsDropEventsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.266 | The total number of events in which frames were dropped due to a lack of resources on upstream cleared. | ||
| NTF omciTcaEthFrameUsOversizePackets | 1.3.6.1.4.1.890.1.5.13.13.19.8.267 | The total number of packets received that were longer than 1518 octets long on upstream. | ||
| NTF omciTcaEthFrameUsOversizePacketsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.268 | The total number of packets received that were longer than 1518 octets long on upstream cleared. | ||
| NTF omciTcaEthFrameUsUndersizePackets | 1.3.6.1.4.1.890.1.5.13.13.19.8.269 | The total number of packets received that were less than 64 octets long on upstream. | ||
| NTF omciTcaEthFrameUsUndersizePacketsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.270 | The total number of packets received that were less than 64 octets long on upstream cleared. | ||
| NTF omciTcaExcessCollision | 1.3.6.1.4.1.890.1.5.13.13.19.8.271 | Transmission failed due to excessive collisions. | ||
| NTF omciTcaExcessCollisionClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.272 | Transmission failed due to excessive collisions cleared. | ||
| NTF omciTcaFcsErrors | 1.3.6.1.4.1.890.1.5.13.13.19.8.273 | Counts frames received on a particular interface that were an integral number of octets in length. | ||
| NTF omciTcaFcsErrorsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.274 | Counts frames received on a particular interface that were an integral number of octets in length cleared. | ||
| NTF omciTcaFragments | 1.3.6.1.4.1.890.1.5.13.13.19.8.277 | The total number of packets received that were less than 64 octets long. | ||
| NTF omciTcaFragmentsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.278 | The total number of packets received that were less than 64 octets long cleared. | ||
| NTF omciTcaFrameTooLongs | 1.3.6.1.4.1.890.1.5.13.13.19.8.279 | Counts received frames that exceeded the maximum permitted frame size. | ||
| NTF omciTcaFrameTooLongsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.280 | Counts received frames that exceeded the maximum permitted frame size cleared. | ||
| NTF omciTcaIntMacRx | 1.3.6.1.4.1.890.1.5.13.13.19.8.283 | Counts frames whose reception failed due to an internal MAC sublayer receive error. | ||
| NTF omciTcaIntMacRxClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.284 | Counts frames whose reception failed due to an internal MAC sublayer receive error cleared. | ||
| NTF omciTcaIntMacTx | 1.3.6.1.4.1.890.1.5.13.13.19.8.285 | Counts frames whose transmission failed due to an internal MAC sublayer transmit error. | ||
| NTF omciTcaIntMacTxClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.286 | Counts frames whose transmission failed due to an internal MAC sublayer transmit error cleared. | ||
| NTF omciTcaIpnpmDnsError | 1.3.6.1.4.1.890.1.5.13.13.19.8.287 | Counts DNS errors received. | ||
| NTF omciTcaIpnpmDnsErrorClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.288 | Counts DNS errors received cleared. | ||
| NTF omciTcaIpnpmIcmpError | 1.3.6.1.4.1.890.1.5.13.13.19.8.289 | Counts ICMP errors received. | ||
| NTF omciTcaIpnpmIcmpErrorClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.290 | Counts ICMP errors received cleared. | ||
| NTF omciTcaJabbers | 1.3.6.1.4.1.890.1.5.13.13.19.8.291 | The total number of packets received that were longer than 1518 octets. | ||
| NTF omciTcaJabbersClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.292 | The total number of packets received that were longer than 1518 octets cleared. | ||
| NTF omciTcaLateCollision | 1.3.6.1.4.1.890.1.5.13.13.19.8.293 | A collision was detected later than 512 bit times into the transmission of a packet. | ||
| NTF omciTcaLateCollisionClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.294 | A collision was detected later than 512 bit times into the transmission of a packet cleared. | ||
| NTF omciTcaMtuExceededDiscard | 1.3.6.1.4.1.890.1.5.13.13.19.8.297 | Counts frames discarded on this port because the MTU was exceeded. | ||
| NTF omciTcaMtuExceededDiscardClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.298 | Counts frames discarded on this port because the MTU was exceeded cleared. | ||
| NTF omciTcaMultiCollisions | 1.3.6.1.4.1.890.1.5.13.13.19.8.299 | Counts successfully transmitted frames whose transmission was delayed by more than one collision. | ||
| NTF omciTcaMultiCollisionsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.300 | Counts successfully transmitted frames whose transmission was delayed by more than one collision cleared. | ||
| NTF omciTcaPppoeFilteredFrameCount | 1.3.6.1.4.1.890.1.5.13.13.19.8.301 | Counts the number of frames discarded due to PPPoE filtering. | ||
| NTF omciTcaPppoeFilteredFrameCountClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.302 | Counts the number of frames discarded due to PPPoE filtering cleared. | ||
| NTF omciTcaRxAndDiscarded | 1.3.6.1.4.1.890.1.5.13.13.19.8.315 | Counts frames received on this port that were discarded due to errors. | ||
| NTF omciTcaRxAndDiscardedClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.316 | Counts frames received on this port that were discarded due to errors cleared. | ||
| NTF omciTcaSingleCollisionFrame | 1.3.6.1.4.1.890.1.5.13.13.19.8.339 | Counts successfully transmitted frames whose transmission was delayed by exactly one collision. | ||
| NTF omciTcaSingleCollisionFrameClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.340 | Counts successfully transmitted frames whose transmission was delayed by exactly one collision cleared. | ||
| NTF omciTcaSqeCount | 1.3.6.1.4.1.890.1.5.13.13.19.8.363 | The number of times that the SQE test error message was generated by the PLS sublayer. | ||
| NTF omciTcaSqeCountClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.364 | The number of times that the SQE test error message was generated by the PLS sublayer cleared. | ||
| NTF omciTcaUndersizePackets | 1.3.6.1.4.1.890.1.5.13.13.19.8.369 | The total number of packets received that were less than 64 octets long. | ||
| NTF omciTcaUndersizePacketsClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.370 | The total number of packets received that were less than 64 octets long cleared. | ||
| NTF omciTemperatureRed | 1.3.6.1.4.1.890.1.5.13.13.19.8.373 | Service has been shut down to avoid equipment damage. | ||
| NTF omciTemperatureRedClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.374 | Service has been shut down to avoid equipment damage cleared. | ||
| NTF omciTemperatureYellow | 1.3.6.1.4.1.890.1.5.13.13.19.8.375 | No service shutdown at present, but the circuit pack is operating beyond its recommended range. | ||
| NTF omciTemperatureYellowClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.376 | No service shutdown at present, but the circuit pack is operating beyond its recommended range cleared. | ||
| NTF omciVideoLos | 1.3.6.1.4.1.890.1.5.13.13.19.8.411 | No signal at the video UNI. | ||
| NTF omciVideoLosClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.412 | No signal at the video UNI cleared. | ||
| NTF omciVoltageRed | 1.3.6.1.4.1.890.1.5.13.13.19.8.417 | Some services have been shut down to avoid power collapse. | ||
| NTF omciVoltageRedClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.418 | Some services have been shut down to avoid power collapse cleared. | ||
| NTF omciVoltageYellowomci | 1.3.6.1.4.1.890.1.5.13.13.19.8.419 | No service shutdown at present, but the line power voltage is below its recommended minimum. | ||
| NTF omciVoltageYellowClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.420 | No service shutdown at present, but the line power voltage is below its recommended minimum cleared. | ||
| NTF omciXtucEsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.421 | XTU-C Errored seconds threshold crossing. | ||
| NTF omciXtucEsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.422 | XTU-C Errored seconds threshold crossing cleared. | ||
| NTF omciXtucFailedLineInitializationsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.423 | XTU-C Failure of line initializations threshold crossing. | ||
| NTF omciXtucFailedLineInitializationsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.424 | XTU-C Failure of line initializations threshold crossing cleared. | ||
| NTF omciXtucFailedShortInitializationsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.425 | XTU-C Failure of short Initializations threshold crossing. | ||
| NTF omciXtucFailedShortInitializationsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.426 | XTU-C Failure of short Initializations threshold crossing cleared. | ||
| NTF omciXtucFecSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.427 | XTU-C FEC seconds threshold crossing. | ||
| NTF omciXtucFecSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.428 | XTU-C FEC seconds threshold crossing cleared. | ||
| NTF omciXtucLineInitializationsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.429 | XTU-C Line initializations threshold crossing. | ||
| NTF omciXtucLineInitializationsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.430 | XTU-C Line initializations threshold crossing cleared. | ||
| NTF omciXtucLossOfFrameSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.431 | XTU-C Loss of frame seconds. | ||
| NTF omciXtucLossOfFrameSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.432 | XTU-C Loss of frame seconds cleared. | ||
| NTF omciXtucLossOfLinkSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.433 | XTU-C Loss of link seconds. | ||
| NTF omciXtucLossOfLinkSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.434 | XTU-C Loss of link seconds cleared. | ||
| NTF omciXtucLossOfPowerSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.435 | XTU-C Loss of power seconds. | ||
| NTF omciXtucLossOfPowerSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.436 | XTU-C Loss of power seconds cleared. | ||
| NTF omciXtucLossOfSignalSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.437 | XTU-C Loss of signal seconds. | ||
| NTF omciXtucLossOfSignalSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.438 | XTU-C Loss of signal seconds cleared. | ||
| NTF omciXtucSesTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.439 | XTU-C Severely errored seconds threshold crossing. | ||
| NTF omciXtucSesTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.440 | XTU-C Severely errored seconds threshold crossing cleared. | ||
| NTF omciXtucShortInitializationsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.441 | XTU-C Short initializations threshold crossing. | ||
| NTF omciXtucShortInitializationsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.442 | XTU-C Short initializations threshold crossing cleared. | ||
| NTF omciXtucUasTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.443 | XTU-C Unavailable seconds threshold crossing. | ||
| NTF omciXtucUasTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.444 | XTU-C Unavailable seconds threshold crossing cleared. | ||
| NTF omciXturEsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.445 | XTU-R Errored seconds threshold crossing. | ||
| NTF omciXturEsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.446 | XTU-R Errored seconds threshold crossing cleared. | ||
| NTF omciXturFecSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.447 | XTU-R Forward error correction anomaly. | ||
| NTF omciXturFecSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.448 | XTU-R Forward error correction anomaly cleared. | ||
| NTF omciXturLossOfFrameSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.449 | XTU-R Loss of frame seconds. | ||
| NTF omciXturLossOfFrameSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.450 | XTU-R Loss of frame seconds cleared. | ||
| NTF omciXturLossOfPowerSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.451 | XTU-R Loss of power seconds. | ||
| NTF omciXturLossOfPowerSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.452 | XTU-R Loss of power seconds cleared. | ||
| NTF omciXturLossOfSignalSecondsTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.453 | XTU-R Loss of signal seconds. | ||
| NTF omciXturLossOfSignalSecondsTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.454 | XTU-R Loss of signal seconds cleared. | ||
| NTF omciXturSesTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.455 | XTU-R severely errored seconds. | ||
| NTF omciXturSesTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.456 | XTU-R severely errored seconds cleared. | ||
| NTF omciXturUasTca | 1.3.6.1.4.1.890.1.5.13.13.19.8.457 | XTU-R Unavailable seconds threshold crossing. | ||
| NTF omciXturUasTcaClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.458 | XTU-R Unavailable seconds threshold crossing cleared. | ||
| NTF omciHighPowerFeedVoltage | 1.3.6.1.4.1.890.1.5.13.13.19.8.459 | ONU has detected that the power feed voltage is higher than the configured threshold. | ||
| NTF omciHighPowerFeedVoltageClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.460 | ONU has detected that the power feed voltage is higher than the configured threshold cleared. | ||
| NTF omciHighLaserBiasCur | 1.3.6.1.4.1.890.1.5.13.13.19.8.461 | ONU has detected that the laser bias current is higher than the configured threshold. | ||
| NTF omciHighLaserBiasCurClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.462 | ONU has detected that the laser bias current is higher than the configured threshold cleared. | ||
| NTF omciHighTemperature | 1.3.6.1.4.1.890.1.5.13.13.19.8.463 | ONU has detected that the temperature is above the configured threshold. | ||
| NTF omciHighTemperatureClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.464 | ONU has detected that the temperature is above the configured threshold cleared. | ||
| NTF omciOntgEqptAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.465 | Functional failure on an internal interface. | ||
| NTF omciOntgEqptAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.466 | Functional failure on an internal interface cleared. | ||
| NTF omciOntgPoweringAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.467 | Loss of external power to battery backup unit. | ||
| NTF omciOntgPoweringAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.468 | Loss of external power to battery backup unit cleared. | ||
| NTF rogueOntDetect | 1.3.6.1.4.1.890.1.5.13.13.19.8.501 | Rogue ont detection. The values of rouge ont detection status are shown as below: 1: start rogue detection 2: stop rogue detection 3: detect rogue exist 4: rogue ont does not exist 5: discover rogue ont Only detection status equals to 5, the serial number and password of rogue ont would be meaningful. Otherwise, the string of serial number and password of ont would be displayed to N/A. | ||
| NTF newOntDetect | 1.3.6.1.4.1.890.1.5.13.13.19.8.502 | New ont detect. | ||
| NTF ontSwDlStart | 1.3.6.1.4.1.890.1.5.13.13.19.8.503 | Software download start. | ||
| NTF ontSwDlStartClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.504 | Software download start cleared. | ||
| NTF ontSwDlSuccess | 1.3.6.1.4.1.890.1.5.13.13.19.8.505 | Software download success. | ||
| NTF ontSwDlFail | 1.3.6.1.4.1.890.1.5.13.13.19.8.506 | Software download fail. | ||
| NTF ponLos | 1.3.6.1.4.1.890.1.5.13.13.19.8.507 | Pon loss of signal. | ||
| NTF ponLosClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.508 | Pon loss of signal cleared. | ||
| NTF omciWanPppoeLinkUp | 1.3.6.1.4.1.890.1.5.13.13.19.8.509 | Ont wan port PPPoE link up. | ||
| NTF omciWanPppoeLinkDown | 1.3.6.1.4.1.890.1.5.13.13.19.8.510 | Ont wan port PPPoE link down. | ||
| NTF gponMacReset | 1.3.6.1.4.1.890.1.5.13.13.19.8.511 | Gpon mac reset. | ||
| NTF ontDdmiRxPowerFail | 1.3.6.1.4.1.890.1.5.13.13.19.8.512 | ONU DDMI Rx Power out of range. | ||
| NTF ontDdmiRxPowerFailClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.513 | ONU DDMI Rx Power out of range cleared. | ||
| NTF ponUnableGetOnuPw | 1.3.6.1.4.1.890.1.5.13.13.19.8.514 | Unable to get password. | ||
| NTF ponOutOfId | 1.3.6.1.4.1.890.1.5.13.13.19.8.515 | This PON port is out of register id for ONU. | ||
| NTF ddmiTempOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.8.551 | DDMI temperature out of range. | ||
| NTF ddmiTempOutOfRangeClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.552 | DDMI temperature out of range cleared. | ||
| NTF ddmiTxPwrOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.8.553 | DDMI TxPower out of range. | ||
| NTF ddmiTxPwrOutOfRangeClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.554 | DDMI TxPower out of range cleared. | ||
| NTF ddmiRxPwrOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.8.555 | DDMI RxPower out of range. | ||
| NTF ddmiRxPwrOutOfRangeClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.556 | DDMI RxPower out of range cleared. | ||
| NTF ddmiVoltageOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.8.557 | DDMI voltage out of range. | ||
| NTF ddmiVoltageOutOfRangeClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.558 | DDMI voltage out of range cleared. | ||
| NTF ddmiBiasOutOfRange | 1.3.6.1.4.1.890.1.5.13.13.19.8.559 | DDMI bias out of range. | ||
| NTF ddmiBiasOutOfRangeClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.560 | DDMI bias out of range cleared. | ||
| NTF gponLinkDown | 1.3.6.1.4.1.890.1.5.13.13.19.8.561 | The trap signifies one gpon port is linked down. | ||
| NTF gponLinkUp | 1.3.6.1.4.1.890.1.5.13.13.19.8.562 | The trap signifies one gpon port is linked up. | ||
| NTF cpuProtectionAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.563 | The trap signifies that CPU may become overloaded and be unable to handle regular tasks property due to receiving large numbers of control packets. | ||
| NTF cpuProtectionAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.564 | The trap signifies that disable port(s) become active or start receiving the packets again with error-disable recovery. | ||
| NTF authorizationFailure | 1.3.6.1.4.1.890.1.5.13.13.19.8.565 | The trap signifies that 802.1x authorization failure. | ||
| NTF highIngressRateAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.566 | The trap signifies that ingress rate is higher than configured threshold rate. | ||
| NTF highIngressRateAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.567 | The trap signifies that ingress rate is higher than configured threshold rate cleared. | ||
| NTF highEgressRateAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.568 | The trap signifies that egress rate is higher than configured threshold rate. | ||
| NTF highEgressRateAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.569 | The trap signifies that egress rate is higher than configured threshold rate cleared. | ||
| NTF discoverUnregisterOntAlarm | 1.3.6.1.4.1.890.1.5.13.13.19.8.570 | The trap signifies that system discovers unregistered ont. | ||
| NTF discoverUnregisterOntAlarmClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.571 | The trap signifies that system discovers unregistered ont cleared. | ||
| NTF omciTcaEthFrameUsCrcErroredFrames | 1.3.6.1.4.1.890.1.5.13.13.19.8.572 | The total number of error frames received on upstream. | ||
| NTF omciTcaEthFrameUsCrcErroredFramesClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.573 | The total number of error frames received on upstream cleared. | ||
| NTF omciTcaEthFrameUsOversizeFrames | 1.3.6.1.4.1.890.1.5.13.13.19.8.574 | The total number of frames received that were longer than 1518 octets long on upstream. | ||
| NTF omciTcaEthFrameUsOversizeFramesClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.575 | The total number of packets received that were longer than 1518 octets long on upstream cleared. | ||
| NTF omciTcaEthFrameUsUndersizeFrames | 1.3.6.1.4.1.890.1.5.13.13.19.8.576 | The total number of frames received that were less than 64 octets long on upstream. | ||
| NTF omciTcaEthFrameUsUndersizeFramesClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.577 | The total number of frames received that were less than 64 octets long on upstream cleared. | ||
| NTF ontMacAntiSpoofing | 1.3.6.1.4.1.890.1.5.13.13.19.8.578 | The gpon ont MAC anti-spoofing happened. | ||
| NTF gponOntTcaFecCodeword | 1.3.6.1.4.1.890.1.5.13.13.19.8.579 | The trap signifies ont is FEC codeword. | ||
| NTF gponOntTcaFecCodewordClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.580 | The trap signifies ont is FEC codeword cleared. | ||
| NTF gponOntTcaBipByte | 1.3.6.1.4.1.890.1.5.13.13.19.8.581 | The trap signifies ont is bip byte. | ||
| NTF gponOntTcaBipByteClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.582 | The trap signifies ont is bip byte cleared. | ||
| NTF gponOntTcaRxPloamCrc | 1.3.6.1.4.1.890.1.5.13.13.19.8.583 | Received PLOAMS with CRC errors. | ||
| NTF gponOntTcaRxPloamCrcClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.584 | Received PLOAMS with CRC errors cleared. | ||
| NTF gponOntTcaRxPloamNonidle | 1.3.6.1.4.1.890.1.5.13.13.19.8.585 | Received non-idle PLOAMS. | ||
| NTF gponOntTcaRxPloamNonidleClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.586 | Received non-idle PLOAMS cleared. | ||
| NTF gponOntTcaPositiveDrift | 1.3.6.1.4.1.890.1.5.13.13.19.8.587 | Accumulated positive drift in bits. | ||
| NTF gponOntTcaPositiveDriftClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.588 | Accumulated positive drift in bits cleared. | ||
| NTF gponOntTcaNegativeDrift | 1.3.6.1.4.1.890.1.5.13.13.19.8.589 | Accumulated negative drift in bits. | ||
| NTF gponOntTcaNegativeDriftClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.590 | Accumulated negative drift in bits cleared. | ||
| NTF gponOntTcaRxOmciPktCrc | 1.3.6.1.4.1.890.1.5.13.13.19.8.591 | Received OMCI packets with CRC errors. | ||
| NTF gponOntTcaRxOmciPktCrcClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.592 | Received OMCI packets with CRC errors cleared. | ||
| NTF gponOntTcaUnreceivedBurst | 1.3.6.1.4.1.890.1.5.13.13.19.8.593 | Un-received Burst allocated to the ONU. | ||
| NTF gponOntTcaUnreceivedBurstClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.594 | Un-received Burst allocated to the ONU cleared. | ||
| NTF gponOntTcaLcdgi | 1.3.6.1.4.1.890.1.5.13.13.19.8.595 | LCDGi errors. | ||
| NTF gponOntTcaLcdgiClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.596 | LCDGi errors cleared. | ||
| NTF gponOntTcaRdi | 1.3.6.1.4.1.890.1.5.13.13.19.8.597 | RDi errors. | ||
| NTF gponOntTcaRdiClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.598 | RDi errors cleared. | ||
| NTF gponOntOmciSuppress | 1.3.6.1.4.1.890.1.5.13.13.19.8.599 | OMCI suppress. | ||
| NTF gponOntTcaRxOmciPkt | 1.3.6.1.4.1.890.1.5.13.13.19.8.600 | Received OMCI packets. | ||
| NTF gponOntTcaRxOmciPktClear | 1.3.6.1.4.1.890.1.5.13.13.19.8.601 | Received OMCI packets cleared. | ||
| NTF gponRogueOntDetection | 1.3.6.1.4.1.890.1.5.13.13.19.8.602 | Detect suspected rogue onu. | ||
| NTF gponRogueOntElimination | 1.3.6.1.4.1.890.1.5.13.13.19.8.603 | Eliminate suspected rogue onu. |
RFC description
IES5206 network element alarms and traps for equipment, DSL, GPON, and system events.