All MIBs › HUAWEI-ENT-VOICE-PORT-MIB
Organization: Huawei Technologies Co.,Ltd.
Last Updated: 2011-05-05
Category: Domain: VoIP/Telephony, Vendor: Huawei
Description: Huawei enterprise voice port MIB providing configuration and status objects for analog (FXS/FXO) and digital voice ports on Huawei routers.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HUAWEI-ENT-VOICE-PORT-MIB?
HUAWEI-ENT-VOICE-PORT-MIB is a Huawei Technologies Co.,Ltd. proprietary MIB configuring analog FXS voice-port parameters on Huawei enterprise voice gateways. Its config table, keyed by port index, records send/receive gain, dial mode, reverse-polarity enable/level, polarity-reverse mode, line lock, NLP (Non-Linear Processing) mode, CLIP reverse-polarity, impedance, current, high/low signal level, KC type, voltage, and actual send/receive gain, while an operational table reports service/admin state. As a configuration/status MIB it lets an administrator confirm FXS port audio-level and signaling settings on a Huawei voice gateway. It is deployed on Huawei Technologies enterprise voice gateways (FXS ports). Engineers can download the HUAWEI-ENT-VOICE-PORT-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in HUAWEI-ENT-VOICE-PORT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Huawei Technologies enterprise voice gateways (FXS ports)
Monitoring Examples
An administrator checks hwEntFxsPortActualSendGain and hwEntFxsPortSrvState to confirm audio level and service state on a Huawei FXS voice port.
What Can Be Monitored
- FXS port audio-gain and service/admin state
This MIB depends on
Related MIBs
Imported Objects
From HUAWEI-MIB
| hwDatacomm | OBJECT-IDENTITY |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| TimeTicks | |
| Unsigned32 | |
| private |
From SNMPv2-TC
| DisplayString | |
| RowStatus | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| INT hwEntBraPortAdminOper | 1.3.6.1.4.1.2011.5.25.252.4.1.5 | INTEGER | read-write | Indicates operation type the bra port. Options: remoteLoop(1) localLoop(2) cancelLoop(3) |
| INT hwEntBraPortAdminState | 1.3.6.1.4.1.2011.5.25.252.4.1.3 | INTEGER | read-only | Indicates admin state of the bra port. Options: noLoopNoTest(1) noLoopTest(2) localLoopNoTest(3) localLoopTest(4) remoteLoopNoTest(5) remoteLoopTest(6) |
| BIT hwEntBraPortAlarmState | 1.3.6.1.4.1.2011.5.25.252.4.1.4 | Bits | read-only | Indicates the alarm state of the bra port, from left to right, each bit represents one alarm state. 0 means no alarm present,1 means the alarm present. bit0: LT overload bit1: S port fault(EI2) bit2: U port fault(LOS/RSY) bit3: S port deactive(SAI) bit4: U port deactive(ACT) |
| INT hwEntBraPortAutoDeactive | 1.3.6.1.4.1.2011.5.25.252.3.1.3 | INTEGER | read-write | Indicates whether to support automatic deactivation. Options: enable(1) -Supported disable(2) -Not supported Default: disable(2) |
| I32 hwEntBraPortAutoDeactiveDelay | 1.3.6.1.4.1.2011.5.25.252.3.1.4 | Integer32 | read-write | Indicates the automatic deactivation delay of the bra port. Default: 30 Unit: second. |
| hwEntBraPortConfigEntry | 1.3.6.1.4.1.2011.5.25.252.3.1 | not-accessible | Indicates the attribute configuration entry of the bra port. | |
| hwEntBraPortConfigGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.3 | The HwEntBraPortConfig group. | ||
| hwEntBraPortConfigTable | 1.3.6.1.4.1.2011.5.25.252.3 | not-accessible | Indicates the attribute configuration table of the bra port. | |
| I32 hwEntBraPortIndex | 1.3.6.1.4.1.2011.5.25.252.3.1.1 | Integer32 | not-accessible | Indicates the slot/subcard/port index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| INT hwEntBraPortL1ActiveMode | 1.3.6.1.4.1.2011.5.25.252.3.1.6 | INTEGER | read-write | Indicates layer 1 active mode of the bra port. Options: stable(1) unstable(2) Default: unstable(2). |
| INT hwEntBraPortL2Monitor | 1.3.6.1.4.1.2011.5.25.252.3.1.8 | INTEGER | read-write | Indicates whether to support layer 2 error statistic. enable(1) -Supported disable(2) -Not supported Default: enable(1) |
| hwEntBraPortOperEntry | 1.3.6.1.4.1.2011.5.25.252.4.1 | not-accessible | Indicates the operation entry (management, maintenance, and status query) of the bra ports. | |
| hwEntBraPortOperGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.4 | The HwEntBraPortOper group. | ||
| I32 hwEntBraPortOperIndex | 1.3.6.1.4.1.2011.5.25.252.4.1.1 | Integer32 | not-accessible | Indicates the BrPortOper index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| hwEntBraPortOperTable | 1.3.6.1.4.1.2011.5.25.252.4 | not-accessible | Indicates the operation table (management, maintenance, and status query) of the bra ports. | |
| INT hwEntBraPortRemotePower | 1.3.6.1.4.1.2011.5.25.252.3.1.2 | INTEGER | read-write | Indicates whether to support remote power supply. Options: enable(1) -Supported disable(2) -Not supported Default: disable(2) |
| INT hwEntBraPortSrvState | 1.3.6.1.4.1.2011.5.25.252.4.1.2 | INTEGER | read-only | Indicates state of the bra port. Options: normal(1) fault(2) deactive(3) powerdeny(4) |
| INT hwEntBraPortUniAlarmReport | 1.3.6.1.4.1.2011.5.25.252.3.1.7 | INTEGER | read-write | Indicates whether to support user network interface fault alarm. enable(1) -Supported disable(2) -Not supported Default: disable(2) |
| INT hwEntBraPortWorkMode | 1.3.6.1.4.1.2011.5.25.252.3.1.5 | INTEGER | read-write | Indicates the bra port working mode. p2mp(1) -Point to multi-point p2p(2) -Point to point Default: p2mp(1) |
| I32 hwEntFxoPortAcImpedance | 1.3.6.1.4.1.2011.5.25.252.8.1.5 | Integer32 | read-write | Indicates AC impedance of the fxo port. 0: 600 1: 900 2: 270 + (750 || 150 nF) and 275 + (780 || 150 nF) 3: 220 + (820 || 120 nF) and 220 + (820 || 115 nF) 4: 370 + (620 || 310 nF) 5: 320 + (1050 || 230 nF) 6: 370 + (820 || 110 nF) 7: 275 + (780 || 115 nF) 8: 20 + (820 || 110 nF) 9: 350 + (1000 || 210 nF) 10: 200 + (680 || 100 nF) 11: 600 + 2.16 F 12: 900 + 1 F 13: 900 + 2.16 F 14: 600 + 1 F 15: Global impedance Default: 0 Unit: |
| INT hwEntFxoPortAdminOper | 1.3.6.1.4.1.2011.5.25.252.9.1.5 | INTEGER | read-write | Indicates the operate type. Options: remoteLoop(1) localLoop(2) cancelLoop(3) |
| INT hwEntFxoPortAdminState | 1.3.6.1.4.1.2011.5.25.252.9.1.3 | INTEGER | read-only | Indicates the fxo port Admin state. Options: noLoopNoTest(1) noLoopTest(2) localLoopNoTest(3) localLoopTest(4) remoteLoopNoTest(5) remoteLoopTest(6) |
| hwEntFxoPortConfigEntry | 1.3.6.1.4.1.2011.5.25.252.8.1 | not-accessible | Indicates the attribute configuration entry of fxo ports. | |
| hwEntFxoPortConfigGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.8 | The HwEntFxoPortConfig group. | ||
| hwEntFxoPortConfigTable | 1.3.6.1.4.1.2011.5.25.252.8 | not-accessible | Indicates the attribute configuration table of fxo ports. | |
| I32 hwEntFxoPortDcImpedance | 1.3.6.1.4.1.2011.5.25.252.8.1.4 | Integer32 | read-write | Indicates DC impedance of the fxo port. 0: 50 1: 800 Default: 0 Unit: |
| I32 hwEntFxoPortFeedMaxCurrent | 1.3.6.1.4.1.2011.5.25.252.8.1.13 | Integer32 | read-write | Indicates the max feed current. 0: 25mA 1: 30mA 2: 35mA 3: 40mA Default: 2 |
| I32 hwEntFxoPortFeedMaxVoltage | 1.3.6.1.4.1.2011.5.25.252.8.1.11 | Integer32 | read-write | Indicates the max feed voltage. Default: -20 Unit:V |
| I32 hwEntFxoPortFeedMinCurrent | 1.3.6.1.4.1.2011.5.25.252.8.1.14 | Integer32 | read-write | Indicates the min of the PTP feed current. 0: 16mA 1: 17mA 2: 18mA 3: 19mA 4: 20mA Default: 0 |
| I32 hwEntFxoPortFeedMinVoltage | 1.3.6.1.4.1.2011.5.25.252.8.1.12 | Integer32 | read-write | Indicates the min feed voltage. Default: -80 Unit:V |
| I32 hwEntFxoPortIndex | 1.3.6.1.4.1.2011.5.25.252.8.1.1 | Integer32 | not-accessible | Indicates the slot/subcard/port index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| INT hwEntFxoPortLineState | 1.3.6.1.4.1.2011.5.25.252.9.1.4 | INTEGER | read-only | Indicates line state of the fxo port. Options: normal(1) fault(2) unknown(3) |
| hwEntFxoPortOperEntry | 1.3.6.1.4.1.2011.5.25.252.9.1 | not-accessible | Indicates the operation entry (management, maintenance, and status query) of the fxo ports. | |
| hwEntFxoPortOperGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.9 | The HwEntFxoPortOper group. | ||
| I32 hwEntFxoPortOperIndex | 1.3.6.1.4.1.2011.5.25.252.9.1.1 | Integer32 | not-accessible | Indicates the FxsPortOper index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| hwEntFxoPortOperTable | 1.3.6.1.4.1.2011.5.25.252.9 | not-accessible | Indicates the operation table (management, maintenance, and status query) of the fxo ports. | |
| I32 hwEntFxoPortRecvGain | 1.3.6.1.4.1.2011.5.25.252.8.1.3 | Integer32 | read-write | Indicates receive gain of the fxo port. 0: 13.5dB, 1: 13.0dB, 2: 12.5dB 3: 12.0dB, 4: 11.5dB, 5: 11.0dB 6: 10.5dB, 7: 10.0dB, 8: 9.5dB 9: 9.0dB, 10: 8.5dB, 11: 8.0dB 12: 7.5dB, 13: 7.0dB, 14: 6.5dB 15: 6.0dB, 16: 5.5dB, 17: 5.0dB 18: 4.5dB, 19: 4.0dB, 20: 3.5dB 21: 3.0dB, 22: 2.5dB, 23: 2.0dB 24: 1.5dB, 25: 1.0dB, 26: 0.5dB 27: 0dB, 28: -0.5dB, 29: -1.0dB 30: -1.5dB, 31: -2.0dB, 32: -2.5dB 33: -3.0dB, 34: -3.5dB, 35: -4.0dB 36: -4.5dB, 37: -5.0dB, 38: -5.5dB 39: -6.0dB, 40: -6.5dB, 41: -7.0dB 42: -7.5dB, 43: -8.0dB, 44: -8.5dB 45: -9.0dB, 46: -9.5dB, 47: -10.0dB 48: -10.5dB, 49: -11.0dB, 50: -11.5dB 51: -12.0dB, 52: -12.5dB, 53: -13.0dB 54: -13.5dB, 55: -14.0dB, 56: -14.5dB 57: -15.0dB, 58: -15.5dB, 59: -16.0dB 60: -16.5dB Default: 34 |
| I32 hwEntFxoPortRingAcAmplitude | 1.3.6.1.4.1.2011.5.25.252.8.1.9 | Integer32 | read-write | Indicates the ring of the AC amplitude. 0: 74V 1: 65V 2: 50V Default: 2 |
| I32 hwEntFxoPortRingFrequency | 1.3.6.1.4.1.2011.5.25.252.8.1.8 | Integer32 | read-write | Indicates the ring frequency. 0: 16Hz 1: 25Hz 2: 50Hz Default: 1 |
| I32 hwEntFxoPortRingMaxInterval | 1.3.6.1.4.1.2011.5.25.252.8.1.7 | Integer32 | read-write | Indicates the max of the ring interval time. 0: not use, 1: 128ms, 2: 256ms, 3: 284ms 4: 512ms, 5: 640ms, 6: 768ms, 7: 896ms 8: 1024ms, 9: 1152ms, 10: 1280ms, 11: 1408ms 12: 1536ms, 13: 1664ms, 14: 1792ms, 15: 1920ms 16: 2000ms, 17: 2500ms, 18: 3000ms, 19: 3500ms 20: 4000ms, 21: 4500ms, 22: 5000ms, 23: 6000ms 24: 7000ms, 25: 8000ms, 26: 9000ms, 27: 10000ms 28: 15000ms Default: 0 |
| I32 hwEntFxoPortRingMinDuration | 1.3.6.1.4.1.2011.5.25.252.8.1.6 | Integer32 | read-write | Indicates the min of the ring duration time. 0: 100ms 1: 150ms 2: 200ms 3: 256ms 4: 384ms 5: 512ms 6: 640ms 7: 1024ms Default: 2 |
| I32 hwEntFxoPortRingOffset | 1.3.6.1.4.1.2011.5.25.252.8.1.10 | Integer32 | read-write | Indicates the ring offset. 0-100: -50V ~ 50V Default: 70 |
| I32 hwEntFxoPortSendGain | 1.3.6.1.4.1.2011.5.25.252.8.1.2 | Integer32 | read-write | Indicates send gain of the fxo port. 0: 13.5dB, 1: 13.0dB, 2: 12.5dB 3: 12.0dB, 4: 11.5dB, 5: 11.0dB 6: 10.5dB, 7: 10.0dB, 8: 9.5dB 9: 9.0dB, 10: 8.5dB, 11: 8.0dB 12: 7.5dB, 13: 7.0dB, 14: 6.5dB 15: 6.0dB, 16: 5.5dB, 17: 5.0dB 18: 4.5dB, 19: 4.0dB, 20: 3.5dB 21: 3.0dB, 22: 2.5dB, 23: 2.0dB 24: 1.5dB, 25: 1.0dB, 26: 0.5dB 27: 0dB, 28: -0.5dB, 29: -1.0dB 30: -1.5dB, 31: -2.0dB, 32: -2.5dB 33: -3.0dB, 34: -3.5dB, 35: -4.0dB 36: -4.5dB, 37: -5.0dB, 38: -5.5dB 39: -6.0dB, 40: -6.5dB, 41: -7.0dB 42: -7.5dB, 43: -8.0dB, 44: -8.5dB 45: -9.0dB, 46: -9.5dB, 47: -10.0dB 48: -10.5dB, 49: -11.0dB, 50: -11.5dB 51: -12.0dB, 52: -12.5dB, 53: -13.0dB 54: -13.5dB, 55: -14.0dB, 56: -14.5dB 57: -15.0dB, 58: -15.5dB, 59: -16.0dB 60: -16.5dB Default: 27 |
| INT hwEntFxoPortSrvState | 1.3.6.1.4.1.2011.5.25.252.9.1.2 | INTEGER | read-only | Indicates state of the fxo port. Options: normal(1) fault(2) deactive(3) powredeny(4) |
| I32 hwEntFxsPortActualRecvGain | 1.3.6.1.4.1.2011.5.25.252.1.1.18 | Integer32 | read-only | Indicates the actual receive gain of the fxs port. 0: 0 dB 1: -0.5 dB 2: -1 dB 3: -1.5 dB 4: -2 dB 5: -2.5 dB 6: -3 dB 7: -3.5 dB 8: -4 dB 9: -4.5 dB 10: -5 dB 11: -5.5 dB 12: -6 dB 13: -6.5 dB 14: -7 dB 15: -7.5 dB 16: -8 dB 17: -8.5 dB 18: -9 dB 19: -9.5 dB 20: -10 dB 21: -10.5 dB 22: -11 dB 23: -11.5 dB 24: -12 dB 255: null |
| I32 hwEntFxsPortActualSendGain | 1.3.6.1.4.1.2011.5.25.252.1.1.17 | Integer32 | read-only | Indicates the actual send gain of the fxs port. 0: 5 dB 1: 4.5 dB 2: 4 dB 3: 3.5 dB 4: 3 dB 5: 2.5 dB 6: 2 dB 7: 1.5 dB 8: 1 dB 9: 0.5 dB 10: 0 dB 11: -0.5 dB 12: -1 dB 13: -1.5 dB 14: -2 dB 15: -2.5 dB 16: -3 dB 17: -3.5 dB 18: -4 dB 19: -4.5 dB 20: -5 dB 21: -5.5 dB 22: -6 dB 255: null |
| INT hwEntFxsPortAdminOper | 1.3.6.1.4.1.2011.5.25.252.2.1.5 | INTEGER | read-write | Indicates operation type the fxs port. Options: remoteLoop(1) localLoop(2) cancelLoop(3) |
| INT hwEntFxsPortAdminState | 1.3.6.1.4.1.2011.5.25.252.2.1.3 | INTEGER | read-only | Indicates admin state of the fxs port. Options: noLoopNoTest(1) noLoopTest(2) localLoopNoTest(3) localLoopTest(4) remoteLoopNoTest(5) remoteLoopTest(6) |
| INT hwEntFxsPortClipReversePole | 1.3.6.1.4.1.2011.5.25.252.1.1.10 | INTEGER | read-write | Indicates whether to support the polarity-reversing pulse when Clip. enable(1) disable(2) Default: disable(2) |
| hwEntFxsPortConfigEntry | 1.3.6.1.4.1.2011.5.25.252.1.1 | not-accessible | Indicates the attribute configuration entry of fxs ports. | |
| hwEntFxsPortConfigGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.1 | The hwEntFxsPortConfig group. | ||
| hwEntFxsPortConfigTable | 1.3.6.1.4.1.2011.5.25.252.1 | not-accessible | Indicates the attribute configuration table of fxs ports. | |
| I32 hwEntFxsPortCurrent | 1.3.6.1.4.1.2011.5.25.252.1.1.12 | Integer32 | read-write | Port current supported by the board. The value ranges from 0 to 1, which indicates the port current value. 0: 16mA steady current 1: 20mA steady current Default: 1 |
| INT hwEntFxsPortDialMode | 1.3.6.1.4.1.2011.5.25.252.1.1.4 | INTEGER | read-write | Indicates the dialing mode. Options: dtmfPulseBoth(1) -DTMF pulse both dtmfOnly(2) -DTMF only pulseOnly(3) -Pulse only Default: dtmfPulseBoth(1) |
| I32 hwEntFxsPortHighLevel | 1.3.6.1.4.1.2011.5.25.252.1.1.13 | Integer32 | read-write | Indicates the high power level width. Default: 100 Unit: ms |
| I32 hwEntFxsPortImpedance | 1.3.6.1.4.1.2011.5.25.252.1.1.11 | Integer32 | read-write | Indicates the port impedance of the board. Each value corresponds to the required impedance in a specified scenario. 0: Bureau machine in China (200+680|| 100nf) 1: User machine in China (200+560|| 100nf) 2: 600-ohm interface 3: Interface of Russia (150+510|| 47nf) 4: (220+820|| 115nf ) 5: (220+820|| 120nf ) 6: 900-ohm interface 7: Interface of Brazil (800|| 50nf) 8: BT0(Zin=87+1052||228nF+229||28.4nF, Zload=93+615||471nF+179||495nF+244||32nF) 9: HK-BT3(Zin=370+620|| 310nf,Zload=600) 10: HK-BT5(Zin=270+264|| 357nf+1434|| 265nf,Zload=600) 11: BT1(BT0 without AGC) 12: BT2(Zin=(87 +1052 //228nF+229 //28.4nF),Zload=(270 +264 //357nF+1434 //265nF)) 13: BT3(Zin=(87 +1052 //228nF+229 //28.4nF),Zload=(164 +162 //363nF+1227 //350nF)) 14: Commonly used in Europe (Zin= 270+750|| 150nf) 15: New zealand (Zin=370+620|| 310nf) Default: 2 |
| I32 hwEntFxsPortIndex | 1.3.6.1.4.1.2011.5.25.252.1.1.1 | Integer32 | not-accessible | Indicates the slot/subcard/port index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| INT hwEntFxsPortKcType | 1.3.6.1.4.1.2011.5.25.252.1.1.15 | INTEGER | read-write | Indicates the KC type. Options: 1. type16kc(1) 2. type12kc(2) Default: type16kc(1) |
| INT hwEntFxsPortLineLock | 1.3.6.1.4.1.2011.5.25.252.1.1.8 | INTEGER | read-write | Indicates whether to support lock port. enable(1) disable(2) Default: enable(1) |
| INT hwEntFxsPortLineState | 1.3.6.1.4.1.2011.5.25.252.2.1.4 | INTEGER | read-only | Indicates line state of the fxs port. Options: normal(1) onEarth(2) unknown(3) |
| I32 hwEntFxsPortLowLevel | 1.3.6.1.4.1.2011.5.25.252.1.1.14 | Integer32 | read-write | Indicates the low power level width. Default: 300 Unit: ms |
| INT hwEntFxsPortNlpMode | 1.3.6.1.4.1.2011.5.25.252.1.1.9 | INTEGER | read-write | Indicates the Nlp mode of the port. normal(1) -Normal mode ecGainAdjust(2) -Ec gain adjust mode enhance(3) -Enhance mode reduce(4) -Reduce mode disable(5): -Close mode Default: normal(1) |
| hwEntFxsPortOperEntry | 1.3.6.1.4.1.2011.5.25.252.2.1 | not-accessible | Indicates the operation entry (management, maintenance, and status query) of the fxs ports. | |
| hwEntFxsPortOperGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.2 | The hwEntFxsPortOper group. | ||
| I32 hwEntFxsPortOperIndex | 1.3.6.1.4.1.2011.5.25.252.2.1.1 | Integer32 | not-accessible | Indicates the FxsPortOper index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| hwEntFxsPortOperTable | 1.3.6.1.4.1.2011.5.25.252.2 | not-accessible | Indicates the operation table (management, maintenance, and status query) of the fxs ports. | |
| INT hwEntFxsPortPolarityReverseMode | 1.3.6.1.4.1.2011.5.25.252.1.1.7 | INTEGER | read-write | Indicates the polarity reversal mode. Options: hard(1) -Hard polarity reversal soft(2) -Soft polarity reversal Default: hard(1) |
| I32 hwEntFxsPortRecvGain | 1.3.6.1.4.1.2011.5.25.252.1.1.3 | Integer32 | read-write | Indicates the receive gain the fxs port. 0: 0 dB 1: -0.5 dB 2: -1 dB 3: -1.5 dB 4: -2 dB 5: -2.5 dB 6: -3 dB 7: -3.5 dB 8: -4 dB 9: -4.5 dB 10: -5 dB 11: -5.5 dB 12: -6 dB 13: -6.5 dB 14: -7 dB 15: -7.5 dB 16: -8 dB 17: -8.5 dB 18: -9 dB 19: -9.5 dB 20: -10 dB 21: -10.5 dB 22: -11 dB 23: -11.5 dB 24: -12 dB Default: 14 |
| INT hwEntFxsPortReversePoleEnable | 1.3.6.1.4.1.2011.5.25.252.1.1.5 | INTEGER | read-write | Indicates whether to support the polarity-reversing pulse. Options: enable(1) disable(2) Default: enable(1) |
| I32 hwEntFxsPortReversePoleLevel | 1.3.6.1.4.1.2011.5.25.252.1.1.6 | Integer32 | read-write | Indicates the level width of the polarity-reversing pulse. Default: 100 Unit: ms Step: 10 ms. |
| I32 hwEntFxsPortSendGain | 1.3.6.1.4.1.2011.5.25.252.1.1.2 | Integer32 | read-write | Indicates the send gain the fxs port. 0: 5 dB 1: 4.5 dB 2: 4 dB 3: 3.5 dB 4: 3 dB 5: 2.5 dB 6: 2 dB 7: 1.5 dB 8: 1 dB 9: 0.5 dB 10: 0 dB 11: -0.5 dB 12: -1 dB 13: -1.5 dB 14: -2 dB 15: -2.5 dB 16: -3 dB 17: -3.5 dB 18: -4 dB 19: -4.5 dB 20: -5 dB 21: -5.5 dB 22: -6 dB Default: 10 |
| INT hwEntFxsPortSrvState | 1.3.6.1.4.1.2011.5.25.252.2.1.2 | INTEGER | read-only | Indicates state of the fxs port. Options: normal(1) fault(2) deactive(3) powerdeny(4) |
| I32 hwEntFxsPortVoltage | 1.3.6.1.4.1.2011.5.25.252.1.1.16 | Integer32 | read-write | Indicates the valid voltage value of KC. 0: 0.45 Vrms 1: 0.775 Vrms 2: 1.0 Vrms 3: 1.5 Vrms 4: 2.0 Vrms 5: 2.5 Vrms 6: 3.0 Vrms 7: 3.5 Vrms 8: 4.0 Vrms 9: 4.5 Vrms Default: 5 |
| INT hwEntVe1PortAccessMode | 1.3.6.1.4.1.2011.5.25.252.5.1.5 | INTEGER | read-write | Indicates physical layer digital section access mode of the ve1 port. Options: digitalAccess(1) directAccess(2) Default:digitalAccess(1) |
| INT hwEntVe1PortAdminOper | 1.3.6.1.4.1.2011.5.25.252.6.1.5 | INTEGER | read-write | Indicates operation type of the ve1 port. Options: remoteLoop(1) localLoop(2) cancelLoop(3) |
| INT hwEntVe1PortAdminState | 1.3.6.1.4.1.2011.5.25.252.6.1.3 | INTEGER | read-only | Indicates admin state of the ve1 port. Options: noLoopNoTest(1) noLoopTest(2) localLoopNoTest(3) localLoopTest(4) remoteLoopNoTest(5) remoteLoopTest(6) |
| hwEntVe1PortConfigEntry | 1.3.6.1.4.1.2011.5.25.252.5.1 | not-accessible | Indicates the attribute configuration entry of the ve1 ports. | |
| hwEntVe1PortConfigGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.5 | The HwEntVe1PortConfig group. | ||
| hwEntVe1PortConfigTable | 1.3.6.1.4.1.2011.5.25.252.5 | not-accessible | Indicates the attribute configuration table of the ve1 ports. | |
| I32 hwEntVe1PortCsesAlarmThreshold | 1.3.6.1.4.1.2011.5.25.252.7.1.4 | Integer32 | read-write | Indicates the sequential severe error second alarm threshold. Default: 4 |
| I32 hwEntVe1PortDmAlarmThreshold | 1.3.6.1.4.1.2011.5.25.252.7.1.2 | Integer32 | read-write | Indicates the degrade minute alarm threshold. Default: 8 |
| BIT hwEntVe1PortErrAlarmSwitch | 1.3.6.1.4.1.2011.5.25.252.5.1.7 | Bits | read-write | Indicates ve1 error alarm switches, from left to right, each bit respresent a switch. 0 means disable, 1 means enable. bit0: report pcm line fault alarm. bit1: when error rate reached ULF(Unconditional Line Failure) threshold, report pcm line fault alarm. bit2: when error rate reached OLF(Optional Line Failure) threshold, report pcm line fault alarm. bit3: when error rate reached LDT(Line Disturbance Transient Event) threshold, report ve1 digital line transient event alarm. bit4: when E1 frame slip frequency exceeded in observation interval reached degraded threshold, report event alarm. bit5: when any line temporary event occurs, report event alarm. Default: 111000 |
| I32 hwEntVe1PortEsAlarmThreshold | 1.3.6.1.4.1.2011.5.25.252.7.1.3 | Integer32 | read-write | Indicates the error second alarm threshold. Default: 432 |
| INT hwEntVe1PortFrameCheckMode | 1.3.6.1.4.1.2011.5.25.252.5.1.2 | INTEGER | read-write | Indicates the CRC4 frame check mode of the ve1 port. Options: enable(1) disable(2) Default: disable(2) |
| INT hwEntVe1PortImpedance | 1.3.6.1.4.1.2011.5.25.252.5.1.3 | INTEGER | read-write | Indicates impedance of the ve1 port. Options: ohm75(1) ohm120(2) Default: ohm75(1) |
| I32 hwEntVe1PortIndex | 1.3.6.1.4.1.2011.5.25.252.5.1.1 | Integer32 | not-accessible | Indicates the slot/subcard/port index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| hwEntVe1PortL1AlarmThresholdEntry | 1.3.6.1.4.1.2011.5.25.252.7.1 | not-accessible | degrade alarm threshold config entry of ve1 port. | |
| hwEntVe1PortL1AlarmThresholdGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.7 | The HwEntVe1PortL1AlarmThreshold group. | ||
| I32 hwEntVe1PortL1AlarmThresholdIndex | 1.3.6.1.4.1.2011.5.25.252.7.1.1 | Integer32 | not-accessible | Indicates the Ve1PortOper index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| hwEntVe1PortL1AlarmThresholdTable | 1.3.6.1.4.1.2011.5.25.252.7 | not-accessible | degrade alarm threshold config table of ve1 port. | |
| INT hwEntVe1PortL2Monitor | 1.3.6.1.4.1.2011.5.25.252.5.1.6 | INTEGER | read-write | Indicates whether to support layer 2 error statistic of the ve1 port. enable(1) disable(2) Default: enable(1). |
| hwEntVe1PortOperEntry | 1.3.6.1.4.1.2011.5.25.252.6.1 | not-accessible | Indicates the operation entry (management, maintenance, and status query) of the ve1 ports. | |
| hwEntVe1PortOperGroup | 1.3.6.1.4.1.2011.5.25.252.10.2.6 | The HwEntVe1PortOper group. | ||
| I32 hwEntVe1PortOperIndex | 1.3.6.1.4.1.2011.5.25.252.6.1.1 | Integer32 | not-accessible | Indicates the Ve1PortOper index. bits 31-24 (8 bits): reserved bits 23-16 (8 bits): slot index bits 15-8 (8 bits): subcard index bits 7-0 (8 bits): port index |
| hwEntVe1PortOperTable | 1.3.6.1.4.1.2011.5.25.252.6 | not-accessible | Indicates the operation table (management, maintenance, and status query) of the ve1 ports. | |
| INT hwEntVe1PortSignalType | 1.3.6.1.4.1.2011.5.25.252.5.1.4 | INTEGER | read-write | Indicates signal type of the ve1 port. Options: ccs(1) cas(2) Default: ccs(1) |
| INT hwEntVe1PortSrvState | 1.3.6.1.4.1.2011.5.25.252.6.1.2 | INTEGER | read-only | Indicates state of the ve1 port. Options: normal(1) fault(2) lineAbnormal(3) powerdeny(4) |
| BIT hwEntVe1PortWarningState | 1.3.6.1.4.1.2011.5.25.252.6.1.4 | Bits | read-only | Indicates the alarm status of the ve1 line. 0 means no alarm present, 1 means the alarm present. bit0: LOS alarm bit1: AIS alarm bit2: LFA alarm bit3: LMFA alarm bit4: RRA alarm bit5: CRCER alarm bit6: SCOL alarm bit7: ULF alarm bit8: OLF alarm bit9: LDT alarm bit10: error second alarm,in direction ET/LT to NT1 bit11: error second alarm,in direction NT1 to ET/LT bit12: sequential severe error second alarm,in direction ET/LT to NT1 bit13: sequential severe error second alarm,in direction NT1 to ET/LT bit14: degrade minute alarm,in direction ET/LT to NT1 bit15: degrade minute alarm,in direction NT1 to ET/LT |
| hwEntVoicePortCompliance | 1.3.6.1.4.1.2011.5.25.252.10.1.1 | The compliance statement for systems supporting the this module. | ||
| hwEntVoicePortCompliances | 1.3.6.1.4.1.2011.5.25.252.10.1 | |||
| hwEntVoicePortConformance | 1.3.6.1.4.1.2011.5.25.252.10 | |||
| hwEntVoicePortGroups | 1.3.6.1.4.1.2011.5.25.252.10.2 | |||
| hwEntVoicePortMIB | 1.3.6.1.4.1.2011.5.25.252 | huawei VOICE PORT mib. |
RFC description
Manages FXS voice port configurations including gain, dialing mode, and impedance settings.
Start monitoring Huawei enterprise voice gateway (analog FXS voice ports) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.