All MIBs › HPOTHERTRAP-MIB
Category: Alarm and Event Management, Vendor: HP/HPE
Description: Defines miscellaneous SNMP trap notifications for HP devices not covered by other HP-specific MIB modules.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HPOTHERTRAP-MIB?
HPOTHERTRAP-MIB is an HP vendor-specific MIB module that defines miscellaneous SNMP trap/notification objects for HP devices and OEM-integrated components (such as Adaptec storage controllers) that are not covered by HP's other dedicated MIB modules. Its sample objects are largely OID-tree placeholder nodes (hp, adaptec, nm, hpnsa, hpnsaECC, hpnsaRemoteAssist) used to organize trap definitions rather than runtime data variables, suggesting this module functions mainly as a notification/registration catalog. Where it does carry monitoring relevance, it is tied to fault/event status -- for instance, ECC memory error events (hpnsaECC) and remote-assist related notifications (hpnsaRemoteAssist) point to hardware-fault and remote-support alerting rather than continuous counters. It depends on HP's broader Network Storage/Server Agent (NSA) MIB family for the objects referenced inside the traps it defines. It would be deployed on HP servers and storage systems (including those with Adaptec RAID/storage controllers) where centralized SNMP trap collection is used for hardware fault alerting, with HPOTHERTRAP-MIB SNMP monitoring covering the miscellaneous events not captured by HP's other dedicated modules.
IPNetwork Monitor allows you to monitor SNMP objects defined in HPOTHERTRAP-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- HP servers and storage systems (including Adaptec-based storage controllers)
Monitoring Examples
Because the visible sample_objects are OID-tree organizational nodes (hp, adaptec, nm, hpnsa, hpnsaECC, hpnsaRemoteAssist) rather than runtime data variables, this module is best understood as a trap/notification definition catalog; a realistic use would be an SNMP trap receiver catching an hpnsaECC-branch notification to alert on a detected ECC memory error, but the MIB itself does not expose pollable status counters in the sample provided.
What Can Be Monitored
- ECC memory error notifications
- remote-assist related alerts
This MIB depends on
Related MIBs
Imported Objects
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| enterprises |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| hp | 1.3.6.1.4.1.11 | |||
| nm | 1.3.6.1.4.1.11.2 | |||
| hpnsa | 1.3.6.1.4.1.11.2.23 | |||
| NTF hPFWUpdate1 | 1.3.6.1.4.1.11.2.23.0.101 | Front Panel Controller firmware updated | ||
| NTF hPFWUpdate2 | 1.3.6.1.4.1.11.2.23.0.102 | Primary Hot Swap Cage Controller firmware updated | ||
| NTF hPFWUpdate3 | 1.3.6.1.4.1.11.2.23.0.103 | Secondary Hot Swap Cage Controller firmware updated | ||
| NTF hPFWUpdate4 | 1.3.6.1.4.1.11.2.23.0.104 | NetServer Management Controller firmware updated | ||
| NTF hPFWUpdate5 | 1.3.6.1.4.1.11.2.23.0.105 | CPU Management Controller firmware updated | ||
| NTF storageCap1 | 1.3.6.1.4.1.11.2.23.0.4096 | Volume Storage Capacity has exceeded the warning threshold level. | ||
| NTF storageCap3 | 1.3.6.1.4.1.11.2.23.0.4097 | Volume Storage Capacity has exceeded the minor threshold level. | ||
| NTF storageCap5 | 1.3.6.1.4.1.11.2.23.0.4098 | Volume Storage Capacity has exceeded the major threshold level. | ||
| NTF systemHW1 | 1.3.6.1.4.1.11.2.23.0.4356 | Post Error has occurred. | ||
| NTF hPDiskSystem1 | 1.3.6.1.4.1.11.2.23.0.8210 | The Defect List Threshold has been exceeded. | ||
| NTF hPRaid1 | 1.3.6.1.4.1.11.2.23.0.8609 | HPDA Controller: Cache Error | ||
| NTF hPRaid3 | 1.3.6.1.4.1.11.2.23.0.8625 | HPDA Logical Drive: Critical | ||
| NTF hPRaid4 | 1.3.6.1.4.1.11.2.23.0.8626 | HPDA Logical Drive Not Available | ||
| NTF hPRaid5 | 1.3.6.1.4.1.11.2.23.0.8641 | HPDA Hot Spare:Failed | ||
| NTF hPRaid7 | 1.3.6.1.4.1.11.2.23.0.8642 | HPDA Hot Spare Succeeded | ||
| NTF hPRaid8 | 1.3.6.1.4.1.11.2.23.0.8657 | HPDA Hard Disk Failed | ||
| NTF hPRaid10 | 1.3.6.1.4.1.11.2.23.0.8673 | HPDA Threshold Exceeded: Parity | ||
| NTF hPRaid12 | 1.3.6.1.4.1.11.2.23.0.8674 | HPDA Threshold Exceeded: Soft Errors | ||
| NTF hPRaid14 | 1.3.6.1.4.1.11.2.23.0.8675 | HPDA Threshold Exceeded: Hardware Errors | ||
| NTF hPRaid16 | 1.3.6.1.4.1.11.2.23.0.8676 | HPDA Threshold Exceeded: Miscellaneous Errors | ||
| NTF hPRaid18 | 1.3.6.1.4.1.11.2.23.0.8677 | HPDA Controller: NVRAM Age | ||
| NTF redundantPower1 | 1.3.6.1.4.1.11.2.23.0.9101 | The Redundant Power Supply module is not operating properly, but there is no power supply module hardware failure. | ||
| NTF redundantPower2 | 1.3.6.1.4.1.11.2.23.0.9103 | Indicates a failure with the AC power source that is connected to one of the redundant power supply units. | ||
| NTF redundantPower4 | 1.3.6.1.4.1.11.2.23.0.9105 | Indicates that one of the redundant power supply modules is not in normal operating condition. | ||
| NTF redundantPower5 | 1.3.6.1.4.1.11.2.23.0.9106 | Indicates that one of the redundant power supply modules is in over temperature protection mode. | ||
| NTF redundantPower7 | 1.3.6.1.4.1.11.2.23.0.9107 | Indicates that one of the redundant power supply modules has been physically removed from the HP NetServer Power Supply Subsystem. | ||
| NTF redundantPower8 | 1.3.6.1.4.1.11.2.23.0.9108 | Indicates that one of the redundant power supply modules has been physically inserted into the HP NetServer Power Supply Subsystem. | ||
| NTF redundantPower9 | 1.3.6.1.4.1.11.2.23.0.9109 | Indicates that one of the redundant power supply modules in the HP NetServer has recovered from an over temperature protection mode. | ||
| NTF redundantPower11 | 1.3.6.1.4.1.11.2.23.0.9110 | Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the warning temperature level. | ||
| NTF redundantPower13 | 1.3.6.1.4.1.11.2.23.0.9111 | Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the emergency temperature level. | ||
| NTF redundantPower14 | 1.3.6.1.4.1.11.2.23.0.9112 | Power System failure A/C Lost | ||
| NTF redundantPower15 | 1.3.6.1.4.1.11.2.23.0.9113 | The Power Supply Subsystem has fewer than the required number of Power Supply Units installed for normal operation or is having problems powering up or down. | ||
| NTF redundantPower37 | 1.3.6.1.4.1.11.2.23.0.9114 | Power Supply Subsystem soft failure | ||
| NTF temperature1 | 1.3.6.1.4.1.11.2.23.0.12288 | Server temperature monitor cannot read temperature data. | ||
| NTF temperature2 | 1.3.6.1.4.1.11.2.23.0.12289 | Server temperature has exceeded the warning temperature threshold. | ||
| NTF temperature3 | 1.3.6.1.4.1.11.2.23.0.12290 | Server temperature has exceeded the emergency temperature threshold. | ||
| NTF networkCard1 | 1.3.6.1.4.1.11.2.23.0.16385 | The total number of packets with receive errors has exceeded the threshold. | ||
| NTF networkCard5 | 1.3.6.1.4.1.11.2.23.0.16386 | The total number of packets with transmit errors has exceeded the threshold. | ||
| NTF networkCard9 | 1.3.6.1.4.1.11.2.23.0.16387 | The total number of LAN Adapter reset errors has exceeded the threshold. | ||
| NTF networkCard13 | 1.3.6.1.4.1.11.2.23.0.16388 | The total number of alignment and CRC errors has exceeded the threshold. | ||
| NTF networkCard17 | 1.3.6.1.4.1.11.2.23.0.16389 | The total number of giant frame packets has exceeded the threshold. | ||
| NTF networkCard21 | 1.3.6.1.4.1.11.2.23.0.16390 | The total number of packets with length less than the required minimum length has exceeded the threshold. | ||
| NTF networkCard25 | 1.3.6.1.4.1.11.2.23.0.16391 | The total number of late collision errors has exceeded the threshold (the network is too large). | ||
| NTF networkCard29 | 1.3.6.1.4.1.11.2.23.0.16392 | The total number of colliding packets has exceeded the threshold (the network is too busy). | ||
| NTF networkCard33 | 1.3.6.1.4.1.11.2.23.0.16393 | The total number of carrier sense errors has exceeded the threshold. | ||
| NTF networkCard37 | 1.3.6.1.4.1.11.2.23.0.16394 | The total number of adapter deferrals has exceeded the threshold (the network is forever busy). | ||
| NTF networkCard41 | 1.3.6.1.4.1.11.2.23.0.16395 | The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. | ||
| NTF networkCard45 | 1.3.6.1.4.1.11.2.23.0.16396 | The total number of Receive Overflow errors has exceeded the threshold. | ||
| NTF networkCard49 | 1.3.6.1.4.1.11.2.23.0.16397 | LAN adapter utilization count has exceeded the threshold. | ||
| NTF networkCard53 | 1.3.6.1.4.1.11.2.23.0.16398 | The LAN adapter which the alarms were configured for, has been replaced by another type of LAN adapter. | ||
| NTF networkCard55 | 1.3.6.1.4.1.11.2.23.0.16399 | There possibly is a dataflow problem with your HP LAN adapter. | ||
| NTF networkCard56 | 1.3.6.1.4.1.11.2.23.0.16400 | The HP LAN adapter driver did not receive a transmit complete interrupt. | ||
| NTF networkCard57 | 1.3.6.1.4.1.11.2.23.0.16401 | There possibly is a dataflow problem with your HP LAN adapter. | ||
| NTF networkCard58 | 1.3.6.1.4.1.11.2.23.0.16402 | There is a dataflow problem with your HP LAN adapter - receive interrupts are being generated, but no receive packets are being present. | ||
| NTF networkCard59 | 1.3.6.1.4.1.11.2.23.0.16403 | There possibly is a problem with your HP LAN adapter - it generates too many buffer pointer errors. | ||
| NTF networkCard60 | 1.3.6.1.4.1.11.2.23.0.16404 | There possibly is a problem with your HP LAN adapter - DMA timed out while transmitting or receiving a packet. | ||
| NTF networkCard61 | 1.3.6.1.4.1.11.2.23.0.16405 | The HP LAN adapter is transmitting faster than the media can handle. | ||
| NTF networkCard62 | 1.3.6.1.4.1.11.2.23.0.16406 | The number of buffer fragments has exceeded the maximum number allowed by the network protocol in your HP LAN adapter. | ||
| NTF networkCard63 | 1.3.6.1.4.1.11.2.23.0.16407 | The total number of errors due to requests of an ECB being denied has exceeded the threshold. | ||
| NTF networkCard64 | 1.3.6.1.4.1.11.2.23.0.16408 | There possibly is a problem with your HP LAN adapter running in bus master mode. | ||
| NTF networkCard65 | 1.3.6.1.4.1.11.2.23.0.16418 | The active NIC in a redundant group has failed. The standby NIC has taken over. | ||
| NTF networkCard67 | 1.3.6.1.4.1.11.2.23.0.16419 | A previously failed NIC in a redundant group has become operational. | ||
| NTF networkCard69 | 1.3.6.1.4.1.11.2.23.0.16420 | The standby NIC in a redundant group has failed. | ||
| NTF networkCard71 | 1.3.6.1.4.1.11.2.23.0.16421 | All NICs (active and standby) in a redundant group have failed. | ||
| NTF systemHW6 | 1.3.6.1.4.1.11.2.23.0.20528 | Parity error has been detected in parity memory | ||
| NTF systemHW8 | 1.3.6.1.4.1.11.2.23.0.20544 | One of the bus masters caused a bus timeout | ||
| NTF systemHW7 | 1.3.6.1.4.1.11.2.23.0.20545 | IPMB Protocol Error | ||
| NTF systemHW73 | 1.3.6.1.4.1.11.2.23.0.20546 | NOS memory dump initiated | ||
| NTF systemHW9 | 1.3.6.1.4.1.11.2.23.0.20560 | I/0 channel check activated by device in EISA slot caused an error | ||
| NTF systemHW11 | 1.3.6.1.4.1.11.2.23.0.20576 | Software NMI has been generated | ||
| NTF systemHW12 | 1.3.6.1.4.1.11.2.23.0.20577 | Uncorrectable Bus Error | ||
| NTF systemHW64 | 1.3.6.1.4.1.11.2.23.0.20578 | Cache Protocol and Parity error | ||
| NTF systemHW65 | 1.3.6.1.4.1.11.2.23.0.20579 | Correctable data error | ||
| NTF systemHW13 | 1.3.6.1.4.1.11.2.23.0.20592 | Memory size has been adjusted during the Power-On-Self-Test during the last boot | ||
| NTF systemHW14 | 1.3.6.1.4.1.11.2.23.0.20624 | Parity error has occurred on a transfer to/from a device on one of the PCI buses | ||
| NTF systemHW16 | 1.3.6.1.4.1.11.2.23.0.20640 | System error has occurred in the PCI subsystem | ||
| NTF systemHW21 | 1.3.6.1.4.1.11.2.23.0.20656 | Processor or Terminator (#) not detected | ||
| NTF systemHW18 | 1.3.6.1.4.1.11.2.23.0.20657 | An uncorrectable Processor problem was detected. | ||
| NTF systemHW19 | 1.3.6.1.4.1.11.2.23.0.20658 | Processor (#) Disabled | ||
| NTF systemHW59 | 1.3.6.1.4.1.11.2.23.0.20659 | The CPU processor module is currently functioning properly, but it is no longer operating within acceptable margins | ||
| NTF systemHW20 | 1.3.6.1.4.1.11.2.23.0.20660 | Processor or Terminator Card Not Detected | ||
| NTF systemHW22 | 1.3.6.1.4.1.11.2.23.0.20661 | Processor Internal Error | ||
| NTF systemHW23 | 1.3.6.1.4.1.11.2.23.0.20662 | Processor Thermal Trip Failure | ||
| NTF systemHW24 | 1.3.6.1.4.1.11.2.23.0.20663 | Processor failed internal self test | ||
| NTF systemHW25 | 1.3.6.1.4.1.11.2.23.0.20664 | Processor hung during POST | ||
| NTF systemHW26 | 1.3.6.1.4.1.11.2.23.0.20665 | Processor startup/initialization failed | ||
| NTF systemHW60 | 1.3.6.1.4.1.11.2.23.0.20666 | PCI Hot Plug fault deasserted | ||
| NTF systemHW61 | 1.3.6.1.4.1.11.2.23.0.20667 | PCI Hot Plug Powered On | ||
| NTF systemHW62 | 1.3.6.1.4.1.11.2.23.0.20668 | PCI Hot Plug fault asserted | ||
| NTF systemHW63 | 1.3.6.1.4.1.11.2.23.0.20669 | PCI Hot Plug Powered off | ||
| NTF systemHW27 | 1.3.6.1.4.1.11.2.23.0.20670 | Multiple Fan Failure | ||
| NTF systemHW79 | 1.3.6.1.4.1.11.2.23.0.20671 | Configuration error in a processor slot | ||
| NTF systemHW28 | 1.3.6.1.4.1.11.2.23.0.20672 | Timeout of failsafe timer has occurred | ||
| NTF systemHW81s | 1.3.6.1.4.1.11.2.23.0.20673 | CPU thermal trip | ||
| NTF systemHW82s | 1.3.6.1.4.1.11.2.23.0.20674 | CPU hot warning | ||
| NTF systemHW80s | 1.3.6.1.4.1.11.2.23.0.20675 | CPU internal error | ||
| NTF systemHW83 | 1.3.6.1.4.1.11.2.23.0.20676 | CPU mismatch | ||
| NTF systemHW58 | 1.3.6.1.4.1.11.2.23.0.20680 | Front Panel Button Violation | ||
| NTF systemHW29 | 1.3.6.1.4.1.11.2.23.0.20704 | Error logging for a specific error has been disabled due to too many errors of that kind in a short time period | ||
| NTF systemHW43 | 1.3.6.1.4.1.11.2.23.0.20736 | An event of warning severity has occurred in the system. For example, chassis door has been opened | ||
| NTF systemHW44 | 1.3.6.1.4.1.11.2.23.0.20737 | An event of critical severity has occurred in the system. For example, both system fans have failed | ||
| NTF voltage2 | 1.3.6.1.4.1.11.2.23.0.20738 | Fatal voltage threshold on one of the system voltage sensors has been exceeded. Voltage sensors are +12V, +5V, -12V, +3.3V to PCI, +3.3V to Processor | ||
| NTF voltage1 | 1.3.6.1.4.1.11.2.23.0.20739 | Warning voltage threshold on one of the system voltage channels has been exceeded. Voltage channels are +12V, +5V, -12V, +3.3V to PCI, +3.3V to Processor | ||
| NTF systemHW10 | 1.3.6.1.4.1.11.2.23.0.20740 | Voltage utilization warning | ||
| NTF systemHW11s | 1.3.6.1.4.1.11.2.23.0.20741 | Voltage utilization error | ||
| NTF aSR1 | 1.3.6.1.4.1.11.2.23.0.20752 | Server has been restarted after the system watchdog timer has timed out due to NOS being hung | ||
| NTF aSR2 | 1.3.6.1.4.1.11.2.23.0.20753 | OS Watchdog Shutdown | ||
| NTF aSR3 | 1.3.6.1.4.1.11.2.23.0.20754 | OS Watchdog poweroff | ||
| NTF systemFW3 | 1.3.6.1.4.1.11.2.23.0.20755 | OS Boot Complete | ||
| NTF systemFW2 | 1.3.6.1.4.1.11.2.23.0.20756 | System Firmware Boot Start | ||
| NTF systemFW4 | 1.3.6.1.4.1.11.2.23.0.20757 | Machine Check Initiated | ||
| NTF systemFW1 | 1.3.6.1.4.1.11.2.23.0.20758 | Generic trap for Critical or Fatal type E0 event from system firmware | ||
| NTF fibreChannel5 | 1.3.6.1.4.1.11.2.23.0.20759 | The Fibre Channel Adapter is Online | ||
| NTF fibreChannel6 | 1.3.6.1.4.1.11.2.23.0.20760 | The Fibre Channel Adapter is Offline | ||
| NTF systemHW30 | 1.3.6.1.4.1.11.2.23.0.20800 | EISA Configuration Utility has altered system configuration | ||
| NTF systemHW48 | 1.3.6.1.4.1.11.2.23.0.20832 | The hardware eventlog has been cleared. | ||
| NTF systemHW49 | 1.3.6.1.4.1.11.2.23.0.20833 | An unrecognized HW log event was detected. | ||
| NTF systemHW50 | 1.3.6.1.4.1.11.2.23.0.20848 | The system has been rebooted. | ||
| NTF systemHW51 | 1.3.6.1.4.1.11.2.23.0.22528 | The Processor in the indicated slot has been disabled by the BIOS. | ||
| NTF systemHW57 | 1.3.6.1.4.1.11.2.23.0.22544 | A single or multiple ECC Error has been detected on the P6 bus. | ||
| NTF hPFan7 | 1.3.6.1.4.1.11.2.23.0.22576 | One of the fans in the Processor/PCI fan tray stopped. | ||
| NTF hPFan8 | 1.3.6.1.4.1.11.2.23.0.22593 | Two or more of the fans in the Processor/PCI Fan Tray have stopped or have been removed. | ||
| NTF hPFan9 | 1.3.6.1.4.1.11.2.23.0.22608 | Fan problem in Processor/PCI Fan Tray has been corrected. | ||
| NTF aSR8 | 1.3.6.1.4.1.11.2.23.0.22624 | The System has been reset by the microcontroller firmware because watchdog timer expired. | ||
| NTF hPFan10 | 1.3.6.1.4.1.11.2.23.0.22640 | One of the fans in the Memory Fan Tray stopped. | ||
| NTF systemHW52 | 1.3.6.1.4.1.11.2.23.0.22651 | A user has halted the system with the NMI switch on the front panel. | ||
| NTF hPFan11 | 1.3.6.1.4.1.11.2.23.0.22657 | Two or more of the fans in the Memory Fan Tray have stopped or been removed. | ||
| NTF hPFan12 | 1.3.6.1.4.1.11.2.23.0.22672 | Fan problem in the Memory Fan Tray has been corrected. | ||
| NTF systemHW53 | 1.3.6.1.4.1.11.2.23.0.22688 | Previously disabled Processor has been reinstalled. | ||
| NTF redundantPower16 | 1.3.6.1.4.1.11.2.23.0.22705 | Temperature alert on designated Power Supply. | ||
| NTF redundantPower18 | 1.3.6.1.4.1.11.2.23.0.22706 | Fan failure on designated Power Supply. | ||
| NTF redundantPower20 | 1.3.6.1.4.1.11.2.23.0.22707 | Voltage error on designated Power Supply. | ||
| NTF redundantPower21 | 1.3.6.1.4.1.11.2.23.0.22708 | Fan speed-up on designated Power Supply. | ||
| NTF redundantPower23 | 1.3.6.1.4.1.11.2.23.0.22709 | A power supply's 3.3 volt supply has gone bad | ||
| NTF redundantPower24 | 1.3.6.1.4.1.11.2.23.0.22710 | A power supply's 5 volt supply has gone bad | ||
| NTF redundantPower25 | 1.3.6.1.4.1.11.2.23.0.22711 | A power supply's 12 volt supply has gone bad | ||
| NTF redundantPower26 | 1.3.6.1.4.1.11.2.23.0.22712 | A power supply's -12 volt supply has gone bad | ||
| NTF redundantPower27 | 1.3.6.1.4.1.11.2.23.0.22720 | Indicated Power Supply has been removed or is not connected properly. | ||
| NTF redundantPower28 | 1.3.6.1.4.1.11.2.23.0.22736 | The indicated Power Supply has been inserted. | ||
| NTF systemHW54 | 1.3.6.1.4.1.11.2.23.0.22752 | The system has been reset because Control Board detected a critical error. | ||
| NTF systemHW55 | 1.3.6.1.4.1.11.2.23.0.22768 | The system has been power-cycled because Control Board detected a critical error. | ||
| NTF systemHW56 | 1.3.6.1.4.1.11.2.23.0.22785 | The Processor Card is missing or not properly terminated in indicated processor module. | ||
| NTF hPEnvironment7 | 1.3.6.1.4.1.11.2.23.0.22801 | Voltage Regulating Module (VRM) on the indicated processor module had failed. | ||
| NTF storageCap2 | 1.3.6.1.4.1.11.2.23.0.24096 | Volume Storage Capacity has exceeded the warning threshold level. | ||
| NTF storageCap4 | 1.3.6.1.4.1.11.2.23.0.24097 | Volume Storage Capacity has exceeded the minor threshold level. | ||
| NTF storageCap6 | 1.3.6.1.4.1.11.2.23.0.24098 | Volume Storage Capacity has exceeded the major threshold level. | ||
| NTF systemHW2 | 1.3.6.1.4.1.11.2.23.0.24356 | Post Error has occurred. | ||
| NTF systemHW3 | 1.3.6.1.4.1.11.2.23.0.24358 | Post Error has occurred. | ||
| NTF temperature4 | 1.3.6.1.4.1.11.2.23.0.24449 | Hot Swap Cage : Temperature monitor error occurred | ||
| NTF temperature5 | 1.3.6.1.4.1.11.2.23.0.24451 | Hot Swap Cage : Warning temperature exceeded | ||
| NTF temperature6 | 1.3.6.1.4.1.11.2.23.0.24452 | Hot Swap Cage : Emergency temperature exceeded! | ||
| NTF systemHW32 | 1.3.6.1.4.1.11.2.23.0.24453 | Power connection failure in one of the devices in the hot swap cage | ||
| NTF systemHW34 | 1.3.6.1.4.1.11.2.23.0.24454 | A device has been removed from the hot swap cage | ||
| NTF systemHW35 | 1.3.6.1.4.1.11.2.23.0.24455 | A device has been inserted into the hot swap cage | ||
| NTF systemHW45 | 1.3.6.1.4.1.11.2.23.0.24456 | Event log is getting full. | ||
| NTF hPEnvironment1 | 1.3.6.1.4.1.11.2.23.0.25000 | One of the voltage sensors crossed its lower non-critical threshold. | ||
| NTF hPEnvironment2 | 1.3.6.1.4.1.11.2.23.0.25001 | One of the voltage sensors crossed its lower critical threshold. | ||
| NTF hPEnvironment3 | 1.3.6.1.4.1.11.2.23.0.25002 | One of the voltage sensors crossed its lower non-recoverable threshold. | ||
| NTF hPEnvironment4 | 1.3.6.1.4.1.11.2.23.0.25003 | One of the voltage sensors crossed its upper non-critical threshold. | ||
| NTF hPEnvironment5 | 1.3.6.1.4.1.11.2.23.0.25004 | One of the voltage sensors crossed its upper critical threshold. | ||
| NTF hPEnvironment6 | 1.3.6.1.4.1.11.2.23.0.25005 | One of the voltage sensors crossed its upper non-recoverable threshold. | ||
| NTF systemHW7s | 1.3.6.1.4.1.11.2.23.0.25006 | VRM failure | ||
| NTF hPTemperature1 | 1.3.6.1.4.1.11.2.23.0.25007 | One of the temperature sensors crossed its lower non-critical threshold. | ||
| NTF hPTemperature2 | 1.3.6.1.4.1.11.2.23.0.25008 | One of the temperature sensors crossed its lower critical threshold. | ||
| NTF hPTemperature3 | 1.3.6.1.4.1.11.2.23.0.25009 | One of the temperature sensors crossed its lower non-recoverable threshold. | ||
| NTF hPTemperature4 | 1.3.6.1.4.1.11.2.23.0.25010 | One of the temperature sensors crossed its upper non-critical threshold. | ||
| NTF hPTemperature5 | 1.3.6.1.4.1.11.2.23.0.25011 | One of the temperature sensors crossed its upper critical threshold. | ||
| NTF hPTemperature6 | 1.3.6.1.4.1.11.2.23.0.25012 | One of the temperature sensors crossed its upper non-recoverable threshold. | ||
| NTF hPFan1 | 1.3.6.1.4.1.11.2.23.0.25013 | One of the fan sensors crossed its lower non-critical threshold. | ||
| NTF hPFan2 | 1.3.6.1.4.1.11.2.23.0.25014 | One of the fan sensors crossed its lower critical threshold. | ||
| NTF hPFan3 | 1.3.6.1.4.1.11.2.23.0.25015 | One of the fan sensors crossed its lower non-recoverable threshold. | ||
| NTF hPFan4 | 1.3.6.1.4.1.11.2.23.0.25016 | One of the fan sensors crossed its upper non-critical threshold. | ||
| NTF hPFan5 | 1.3.6.1.4.1.11.2.23.0.25017 | One of the fan sensors crossed its upper critical threshold. | ||
| NTF hPFan6 | 1.3.6.1.4.1.11.2.23.0.25018 | One of the fan sensors crossed its upper non-recoverable threshold. | ||
| NTF hPChassis1 | 1.3.6.1.4.1.11.2.23.0.25019 | The chassis has been opened. | ||
| NTF hPChassis2 | 1.3.6.1.4.1.11.2.23.0.25020 | I/O area open | ||
| NTF hPChassis3 | 1.3.6.1.4.1.11.2.23.0.25021 | Processor area open | ||
| NTF systemHW80 | 1.3.6.1.4.1.11.2.23.0.25022 | Battery cycles have gone beyond the upper non-critical range | ||
| NTF systemHW81 | 1.3.6.1.4.1.11.2.23.0.25023 | Battery cycles have gone beyond the upper critical range | ||
| NTF systemHW82 | 1.3.6.1.4.1.11.2.23.0.25024 | Battery cycles have gone beyond the upper non-recoverable range | ||
| NTF hPFan13 | 1.3.6.1.4.1.11.2.23.0.25025 | A system fan module error has occurred | ||
| NTF hPFan14 | 1.3.6.1.4.1.11.2.23.0.25026 | A system fan module error has occurred | ||
| NTF hPFan15 | 1.3.6.1.4.1.11.2.23.0.25027 | Fan module failure | ||
| NTF hPFan16 | 1.3.6.1.4.1.11.2.23.0.25028 | Fan module failure | ||
| NTF systemHW84 | 1.3.6.1.4.1.11.2.23.0.25780 | Unrecoverable chipset error has occurred in system board . | ||
| NTF hPRaid2 | 1.3.6.1.4.1.11.2.23.0.28609 | HPDA Controller: Cache Error | ||
| NTF hPRaid6 | 1.3.6.1.4.1.11.2.23.0.28641 | HPDA Hot Spare:Failed | ||
| NTF hPRaid9 | 1.3.6.1.4.1.11.2.23.0.28657 | HPDA Hard Disk Failed | ||
| NTF hPRaid11 | 1.3.6.1.4.1.11.2.23.0.28673 | HPDA Threshold Exceeded: Parity | ||
| NTF hPRaid13 | 1.3.6.1.4.1.11.2.23.0.28674 | HPDA Threshold Exceeded: Soft Errors | ||
| NTF hPRaid15 | 1.3.6.1.4.1.11.2.23.0.28675 | HPDA Threshold Exceeded: Hardware Errors | ||
| NTF hPRaid17 | 1.3.6.1.4.1.11.2.23.0.28676 | HPDA Threshold Exceeded: Miscellaneous Errors | ||
| NTF hPRaid19 | 1.3.6.1.4.1.11.2.23.0.28677 | HPDA Controller: NVRAM Age | ||
| NTF redundantPower29 | 1.3.6.1.4.1.11.2.23.0.29101 | Indicated Power Supply has been removed. | ||
| NTF redundantPower30 | 1.3.6.1.4.1.11.2.23.0.29102 | The indicated Power Supply has been inserted. | ||
| NTF redundantPower31 | 1.3.6.1.4.1.11.2.23.0.29103 | The indicated Power Supply Unit power has failed. | ||
| NTF redundantPower33 | 1.3.6.1.4.1.11.2.23.0.29104 | Power supply subsystem redundancy gained. | ||
| NTF redundantPower34 | 1.3.6.1.4.1.11.2.23.0.29105 | Power supply sunsystem redundancy lost. | ||
| NTF redundantPower35 | 1.3.6.1.4.1.11.2.23.0.29106 | The server Power Supply Subsystem has fewer than the required number of Power Supply Units installed for normal operation. | ||
| NTF redundantPower36 | 1.3.6.1.4.1.11.2.23.0.29107 | The server Power Supply Subsystem has fewer than the required number of Power Supply Units installed for normal operation. | ||
| NTF redundantPower32 | 1.3.6.1.4.1.11.2.23.0.29109 | Predictive failure/alert in power supply | ||
| NTF systemHW4 | 1.3.6.1.4.1.11.2.23.0.34356 | System boot (POST Complete). | ||
| NTF systemHW5 | 1.3.6.1.4.1.11.2.23.0.34357 | Netserver Management Controller started | ||
| NTF systemHW46 | 1.3.6.1.4.1.11.2.23.0.34456 | Event log cleared | ||
| NTF systemHW47 | 1.3.6.1.4.1.11.2.23.0.44456 | SDR area cleared | ||
| NTF systemHW83s | 1.3.6.1.4.1.11.2.23.0.44457 | FRU internal use area cleared | ||
| NTF systemHW100 | 1.3.6.1.4.1.11.2.23.0.53001 | SMART predictive failure detected | ||
| NTF systemHW33 | 1.3.6.1.4.1.11.2.23.0.54453 | system Voltage failure | ||
| NTF systemHW36 | 1.3.6.1.4.1.11.2.23.0.54454 | A SCSI cable has been removed from the hot swap cage. | ||
| NTF systemHW37 | 1.3.6.1.4.1.11.2.23.0.54455 | A SCSI cable was attached to hot swap cage. | ||
| NTF systemHW38 | 1.3.6.1.4.1.11.2.23.0.54456 | A SCSI terminator has been removed from the hot swap cage. | ||
| NTF systemHW39 | 1.3.6.1.4.1.11.2.23.0.54457 | A SCSI terminator has been attached in the hot swap cage. | ||
| NTF systemHW74 | 1.3.6.1.4.1.11.2.23.0.54460 | SCSI Duplex Board has been removed | ||
| NTF systemHW75 | 1.3.6.1.4.1.11.2.23.0.54461 | SCSI Duplex Board has been inserted | ||
| NTF systemHW78 | 1.3.6.1.4.1.11.2.23.0.54464 | SCSI Bus Type has changed | ||
| NTF systemHW76 | 1.3.6.1.4.1.11.2.23.0.54465 | Normal ACPI server shutdown | ||
| NTF systemHW77 | 1.3.6.1.4.1.11.2.23.0.54466 | ACPI hardware failure | ||
| NTF networkCard2 | 1.3.6.1.4.1.11.2.23.0.116385 | The total number of packets with receive errors has exceeded the threshold. | ||
| NTF networkCard6 | 1.3.6.1.4.1.11.2.23.0.116386 | The total number of packets with transmit errors has exceeded the threshold. | ||
| NTF networkCard10 | 1.3.6.1.4.1.11.2.23.0.116387 | The total number of LAN Adapter reset errors has exceeded the threshold. | ||
| NTF networkCard14 | 1.3.6.1.4.1.11.2.23.0.116388 | The total number of alignment and CRC errors has exceeded the threshold. | ||
| NTF networkCard18 | 1.3.6.1.4.1.11.2.23.0.116389 | The total number of giant frame packets has exceeded the threshold. | ||
| NTF networkCard22 | 1.3.6.1.4.1.11.2.23.0.116390 | The total number of packets with length less than the required minimum length has exceeded the threshold. | ||
| NTF networkCard26 | 1.3.6.1.4.1.11.2.23.0.116391 | The total number of late collision errors has exceeded the threshold (the network is too large). | ||
| NTF networkCard30 | 1.3.6.1.4.1.11.2.23.0.116392 | The total number of colliding packets has exceeded the threshold (the network is too busy). | ||
| NTF networkCard34 | 1.3.6.1.4.1.11.2.23.0.116393 | The total number of carrier sense errors has exceeded the threshold. | ||
| NTF networkCard38 | 1.3.6.1.4.1.11.2.23.0.116394 | The total number of adapter deferrals has exceeded the threshold (the network is forever busy). | ||
| NTF networkCard42 | 1.3.6.1.4.1.11.2.23.0.116395 | The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. | ||
| NTF networkCard46 | 1.3.6.1.4.1.11.2.23.0.116396 | The total number of Receive Overflow errors has exceeded the threshold. | ||
| NTF networkCard50 | 1.3.6.1.4.1.11.2.23.0.116397 | LAN adapter utilization count has exceeded the threshold. | ||
| NTF networkCard54 | 1.3.6.1.4.1.11.2.23.0.116398 | The LAN adapter which the alarms were configured for, has been replaced by another type of LAN adapter. | ||
| NTF networkCard66 | 1.3.6.1.4.1.11.2.23.0.116418 | The active NIC in a redundant group has failed. The standby NIC has taken over. | ||
| NTF networkCard68 | 1.3.6.1.4.1.11.2.23.0.116419 | A previously failed NIC in a redundant group has become operational. | ||
| NTF networkCard70 | 1.3.6.1.4.1.11.2.23.0.116420 | The standby NIC in a redundant group has failed. | ||
| NTF networkCard72 | 1.3.6.1.4.1.11.2.23.0.116421 | All NICs (active and standby) in a redundant group have failed. | ||
| NTF redundantPower3 | 1.3.6.1.4.1.11.2.23.0.209103 | Indicates a failure with the AC power source that is connected to one of the redundant power supply units. | ||
| NTF redundantPower6 | 1.3.6.1.4.1.11.2.23.0.209106 | Indicates that one of the redundant power supply modules is in over temperature protection mode. | ||
| NTF redundantPower10 | 1.3.6.1.4.1.11.2.23.0.209109 | Indicates that one of the redundant power supply modules in the HP NetServer has recovered from an over temperature protection mode. | ||
| NTF redundantPower12 | 1.3.6.1.4.1.11.2.23.0.209110 | Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the warning temperature level. | ||
| NTF networkCard3 | 1.3.6.1.4.1.11.2.23.0.216385 | The total number of packets with receive errors has exceeded the threshold. | ||
| NTF networkCard7 | 1.3.6.1.4.1.11.2.23.0.216386 | The total number of packets with transmit errors has exceeded the threshold. | ||
| NTF networkCard11 | 1.3.6.1.4.1.11.2.23.0.216387 | The total number of LAN Adapter reset errors has exceeded the threshold. | ||
| NTF networkCard15 | 1.3.6.1.4.1.11.2.23.0.216388 | The total number of alignment and CRC errors has exceeded the threshold. | ||
| NTF networkCard19 | 1.3.6.1.4.1.11.2.23.0.216389 | The total number of giant frame packets has exceeded the threshold. | ||
| NTF networkCard23 | 1.3.6.1.4.1.11.2.23.0.216390 | The total number of packets with length less than the required minimum length has exceeded the threshold. | ||
| NTF networkCard27 | 1.3.6.1.4.1.11.2.23.0.216391 | The total number of late collision errors has exceeded the threshold (the network is too large). | ||
| NTF networkCard31 | 1.3.6.1.4.1.11.2.23.0.216392 | The total number of colliding packets has exceeded the threshold (the network is too busy). | ||
| NTF networkCard35 | 1.3.6.1.4.1.11.2.23.0.216393 | The total number of carrier sense errors has exceeded the threshold. | ||
| NTF networkCard39 | 1.3.6.1.4.1.11.2.23.0.216394 | The total number of adapter deferrals has exceeded the threshold (the network is forever busy). | ||
| NTF networkCard43 | 1.3.6.1.4.1.11.2.23.0.216395 | The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. | ||
| NTF networkCard47 | 1.3.6.1.4.1.11.2.23.0.216396 | The total number of Receive Overflow errors has exceeded the threshold. | ||
| NTF networkCard51 | 1.3.6.1.4.1.11.2.23.0.216397 | LAN adapter utilization count has exceeded the threshold. | ||
| NTF systemHW10s | 1.3.6.1.4.1.11.2.23.0.220560 | I/0 channel check activated by device in EISA slot caused an error | ||
| NTF hPECCMemory10 | 1.3.6.1.4.1.11.2.23.0.220592 | System memory size reduced due to error in memory slot | ||
| NTF systemHW15 | 1.3.6.1.4.1.11.2.23.0.220624 | Parity error has occurred on a transfer to or from a device on one of the PCI buses | ||
| NTF systemHW17 | 1.3.6.1.4.1.11.2.23.0.220640 | System error has occurred in the PCI subsystem | ||
| NTF aSR4 | 1.3.6.1.4.1.11.2.23.0.220752 | Server has been restarted after the system watchdog timer has timed out due to NOS being hung | ||
| NTF systemHW31 | 1.3.6.1.4.1.11.2.23.0.220800 | Configuration Utility has altered system configuration | ||
| NTF redundantPower17 | 1.3.6.1.4.1.11.2.23.0.222705 | Temperature alert on designated Power Supply. | ||
| NTF redundantPower19 | 1.3.6.1.4.1.11.2.23.0.222706 | Fan failure on designated Power Supply. | ||
| NTF redundantPower22 | 1.3.6.1.4.1.11.2.23.0.222708 | Fan speed-up on designated Power Supply. | ||
| NTF temperature7 | 1.3.6.1.4.1.11.2.23.0.224449 | Hot Swap Cage : Temperature monitor error occurred | ||
| NTF temperature8 | 1.3.6.1.4.1.11.2.23.0.224451 | Hot Swap Cage : Warning temperature exceeded | ||
| NTF temperature9 | 1.3.6.1.4.1.11.2.23.0.224452 | Hot Swap Cage : Emergency temperature exceeded! | ||
| NTF systemHW40 | 1.3.6.1.4.1.11.2.23.0.224453 | Power connection failure in one of the devices in the hot swap cage | ||
| NTF systemHW41 | 1.3.6.1.4.1.11.2.23.0.224454 | A device has been removed from the hot swap cage | ||
| NTF systemHW42 | 1.3.6.1.4.1.11.2.23.0.224455 | A device has been inserted into the hot swap cage | ||
| NTF systemHW67 | 1.3.6.1.4.1.11.2.23.0.254454 | A SCSI cable has been removed from the hot swap cage. | ||
| NTF systemHW68 | 1.3.6.1.4.1.11.2.23.0.254455 | A SCSI cable was attached to the hot swap cage. | ||
| NTF systemHW69 | 1.3.6.1.4.1.11.2.23.0.254456 | A SCSI terminator has been removed from the hot swap cage. | ||
| NTF systemHW70 | 1.3.6.1.4.1.11.2.23.0.254457 | A SCSI terminator has been attached in the hot swap cage. | ||
| NTF networkCard4 | 1.3.6.1.4.1.11.2.23.0.316385 | The total number of packets with receive errors has exceeded the threshold. | ||
| NTF networkCard8 | 1.3.6.1.4.1.11.2.23.0.316386 | The total number of packets with transmit errors has exceeded the threshold. | ||
| NTF networkCard12 | 1.3.6.1.4.1.11.2.23.0.316387 | The total number of LAN Adapter reset errors has exceeded the threshold. | ||
| NTF networkCard16 | 1.3.6.1.4.1.11.2.23.0.316388 | The total number of alignment and CRC errors has exceeded the threshold. | ||
| NTF networkCard20 | 1.3.6.1.4.1.11.2.23.0.316389 | The total number of giant frame packets has exceeded the threshold. | ||
| NTF networkCard24 | 1.3.6.1.4.1.11.2.23.0.316390 | The total number of packets with length less than the required minimum length has exceeded the threshold. | ||
| NTF networkCard28 | 1.3.6.1.4.1.11.2.23.0.316391 | The total number of late collision errors has exceeded the threshold (the network is too large). | ||
| NTF networkCard32 | 1.3.6.1.4.1.11.2.23.0.316392 | The total number of colliding packets has exceeded the threshold (the network is too busy). | ||
| NTF networkCard36 | 1.3.6.1.4.1.11.2.23.0.316393 | The total number of carrier sense errors has exceeded the threshold. | ||
| NTF networkCard40 | 1.3.6.1.4.1.11.2.23.0.316394 | The total number of adapter deferrals has exceeded the threshold (the network is forever busy). | ||
| NTF networkCard44 | 1.3.6.1.4.1.11.2.23.0.316395 | The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. | ||
| NTF networkCard48 | 1.3.6.1.4.1.11.2.23.0.316396 | The total number of Receive Overflow errors has exceeded the threshold. | ||
| NTF networkCard52 | 1.3.6.1.4.1.11.2.23.0.316397 | LAN adapter utilization count has exceeded the threshold. | ||
| NTF aSR5 | 1.3.6.1.4.1.11.2.23.0.320752 | Server has not been restarted after the system watchdog timer has timed out due to NOS being hung | ||
| NTF systemHW71 | 1.3.6.1.4.1.11.2.23.0.324454 | A drive has been removed from the hot swap cage | ||
| NTF systemHW72 | 1.3.6.1.4.1.11.2.23.0.324455 | A drive has been inserted into the hot swap cage | ||
| NTF aSR6 | 1.3.6.1.4.1.11.2.23.0.420752 | Server has been powered down after the system watchdog timer has timed out due to NOS being hung | ||
| NTF aSR7 | 1.3.6.1.4.1.11.2.23.0.520752 | Server has been power cycled after the system watchdog timer has timed out due to NOS being hung | ||
| hpnsaECC | 1.3.6.1.4.1.11.2.23.6 | |||
| NTF hPECCMemory11 | 1.3.6.1.4.1.11.2.23.6.0.4360 | ECC error corrected in memory module | ||
| NTF hPECCMemory12 | 1.3.6.1.4.1.11.2.23.6.0.4361 | Uncorrectable multi-bit ECC error has occurred in memory module | ||
| NTF hPECCMemory13 | 1.3.6.1.4.1.11.2.23.6.0.4363 | Repeated ECC error corrected in memory module | ||
| NTF hPECCMemory14 | 1.3.6.1.4.1.11.2.23.6.0.4364 | ECC memory module is operating outside of acceptable margins | ||
| NTF hPECCMemory15 | 1.3.6.1.4.1.11.2.23.6.0.4365 | Memory Mirroring switched to Slave Set | ||
| NTF hPECCMemory16 | 1.3.6.1.4.1.11.2.23.6.0.4366 | Faulty row switched to Hot Spare row | ||
| NTF hPECCMemory2 | 1.3.6.1.4.1.11.2.23.6.0.24353 | A single-bit error has been corrected in one of the memory modules. | ||
| NTF hPECCMemory3 | 1.3.6.1.4.1.11.2.23.6.0.24354 | Predictive failure in a memory module | ||
| NTF hPECCMemory7 | 1.3.6.1.4.1.11.2.23.6.0.24357 | A Multiple-bit error has occurred in one of the memory modules | ||
| NTF hPECCMemory9 | 1.3.6.1.4.1.11.2.23.6.0.24359 | Single-bit repeated error | ||
| hpnsaRemoteAssist | 1.3.6.1.4.1.11.2.23.8 | |||
| NTF rAVoltage1 | 1.3.6.1.4.1.11.2.23.8.0.109 | The server has lost the power completely. | ||
| NTF rAVoltage2 | 1.3.6.1.4.1.11.2.23.8.0.111 | Voltage measured in the server has gone outside of -12V Upper Threshold. | ||
| NTF rAVoltage3 | 1.3.6.1.4.1.11.2.23.8.0.113 | Voltage measured in the server has gone outside of +3.3V Upper Threshold. | ||
| NTF rAVoltage4 | 1.3.6.1.4.1.11.2.23.8.0.114 | Voltage measured in the server has gone outside of +5V Upper Threshold. | ||
| NTF rAVoltage5 | 1.3.6.1.4.1.11.2.23.8.0.115 | Voltage measured in the server has gone outside of +12V Upper Threshold. | ||
| NTF rAVoltage6 | 1.3.6.1.4.1.11.2.23.8.0.121 | Voltage measured in the server has gone outside of -12V Lower Threshold. | ||
| NTF rAVoltage10 | 1.3.6.1.4.1.11.2.23.8.0.122 | The HP Remote Assistant Card's battery charging circuit is bad. | ||
| NTF rAVoltage7 | 1.3.6.1.4.1.11.2.23.8.0.123 | Voltage measured in the server has gone outside of +3.3V Lower Threshold. | ||
| NTF rAVoltage8 | 1.3.6.1.4.1.11.2.23.8.0.124 | Voltage measured in the server has gone outside of +5V Lower Threshold. | ||
| NTF rAVoltage9 | 1.3.6.1.4.1.11.2.23.8.0.125 | Voltage measured in the server has gone outside of +12V Lower Threshold. | ||
| NTF rATemp1 | 1.3.6.1.4.1.11.2.23.8.0.211 | The server temperature measured on the HP Remote Assistant Card has exceeded the configured warning threshold. | ||
| NTF rATemp2 | 1.3.6.1.4.1.11.2.23.8.0.221 | The server temperature measured on the HP Remote Assistant Card has exceeded the configured threshold and the server has been automatically shut down. | ||
| NTF rATemp4 | 1.3.6.1.4.1.11.2.23.8.0.231 | The server temperature measured on the HP Remote Assistant Card has exceeded the configured Graceful Shutdown threshold value by 5 degrees C and the server has been automatically shut down. | ||
| NTF rAOther1 | 1.3.6.1.4.1.11.2.23.8.0.401 | An administrator has logged in to the HP Remote Assistant Card. | ||
| NTF rAOther3 | 1.3.6.1.4.1.11.2.23.8.0.402 | An unauthorized user has made 3 or more unsuccessful attempts to log in to the HP Remote Assistant Card within a 5-minute period of time. | ||
| NTF rAOther5 | 1.3.6.1.4.1.11.2.23.8.0.403 | The HP Remote Assistant Card's battery charging circuit is bad. | ||
| NTF rAOther6 | 1.3.6.1.4.1.11.2.23.8.0.404 | The HP Remote Assistant Card has been shut down. | ||
| NTF rAOther20 | 1.3.6.1.4.1.11.2.23.8.0.405 | A remote user disconnected from the HP RA or Remote Control card. | ||
| NTF rAOther21 | 1.3.6.1.4.1.11.2.23.8.0.406 | An administrator has been automatically disconnected from the HP Remote Assistant board. The administrator was inactive for more than five minutes. | ||
| NTF rAOther23 | 1.3.6.1.4.1.11.2.23.8.0.407 | An administrator has been prematurely disconnected from the Remote Assistant board. | ||
| NTF rAOther25 | 1.3.6.1.4.1.11.2.23.8.0.408 | An administrator failed to connect to the HP Remote Assistant board on a dialback | ||
| NTF rAASR1 | 1.3.6.1.4.1.11.2.23.8.0.501 | ASR has stopped notifying the HP Remote Assistant Card that the system is running correctly (the server probably hung or crashed). | ||
| NTF rAASR2 | 1.3.6.1.4.1.11.2.23.8.0.502 | The HP Remote Assistant card has restarted the server due to the NOS being hung. | ||
| NTF rAASR3 | 1.3.6.1.4.1.11.2.23.8.0.503 | The Automatic Server Restart software has been enabled by the Remote Assistant ASR timer. | ||
| NTF rAASR4 | 1.3.6.1.4.1.11.2.23.8.0.504 | The HP Remote Assistant Automatic Server Restart timer has been disabled. | ||
| NTF rAOther7 | 1.3.6.1.4.1.11.2.23.8.0.601 | An administrator has executed a remote on the server via the HP Remote Assistant Card. | ||
| NTF rAOther9 | 1.3.6.1.4.1.11.2.23.8.0.602 | An administrator has executed a remote power cycle on the server via the HP Remote Assistant Card. | ||
| NTF rAOther12 | 1.3.6.1.4.1.11.2.23.8.0.603 | An administrator has executed a remote power down of the server via the HP Remote Assistant Card. | ||
| NTF rAOther18 | 1.3.6.1.4.1.11.2.23.8.0.701 | The server's BIOS has successfully initialized the HP Remote Assistant Card during the boot process. | ||
| NTF rABusUsage1 | 1.3.6.1.4.1.11.2.23.8.0.800 | The 5-minute average EISA bus utilization has exceeded the configured threshold. | ||
| NTF rAOther19 | 1.3.6.1.4.1.11.2.23.8.0.900 | An administrator has executed Test Page from the HP Remote Assistant Configuration Utility. | ||
| NTF rAOther29 | 1.3.6.1.4.1.11.2.23.8.0.901 | The HP Remote Assistant modem was unable to connect to the TAP paging service modem. | ||
| NTF rAOther31 | 1.3.6.1.4.1.11.2.23.8.0.902 | HP Remote Assistant was unable to connect with the TAP paging service. | ||
| NTF rAOther32 | 1.3.6.1.4.1.11.2.23.8.0.903 | HP Remote Assistant was unable to log on to the TAP paging service. | ||
| NTF rAOther35 | 1.3.6.1.4.1.11.2.23.8.0.904 | The HP Remote Assistant pager message was rejected | ||
| NTF rAOther10 | 1.3.6.1.4.1.11.2.23.8.0.1602 | A remote user has executed a remote power cycle on the server via the HP RA or Remote Control. | ||
| NTF rAOther13 | 1.3.6.1.4.1.11.2.23.8.0.1603 | A remote user has executed a remote power down of the server via the HP RA or Remote Control card. | ||
| NTF rATemp3 | 1.3.6.1.4.1.11.2.23.8.0.2221 | The server temperature or voltage levels measured by the remote management hardware has exceeded the configured threshold. The server has been automatically shut down. | ||
| NTF rAOther2 | 1.3.6.1.4.1.11.2.23.8.0.2401 | A remote user has logged in to the HP RA or Remote Control card. | ||
| NTF rAOther4 | 1.3.6.1.4.1.11.2.23.8.0.2402 | An unauthorized user has made 3 or more unsuccessful attempts to log in to the HP RA or Remote Control card. | ||
| NTF rAOther22 | 1.3.6.1.4.1.11.2.23.8.0.2406 | A remote user has been automatically disconnected from the HP RA or Remote Control card, because of inactivity. | ||
| NTF rAOther24 | 1.3.6.1.4.1.11.2.23.8.0.2407 | A remote user has been prematurely disconnected from the HP RA or Remote Control card. | ||
| NTF rAOther26 | 1.3.6.1.4.1.11.2.23.8.0.2408 | A remote user failed to connect to the HP RA or Remote Control on a dialback | ||
| NTF rAOther8 | 1.3.6.1.4.1.11.2.23.8.0.2601 | An administrator has executed a remote on the server via the HP RA or Remote Control card. | ||
| NTF rAOther17 | 1.3.6.1.4.1.11.2.23.8.0.2604 | A remote user has executed a remote graceful shutdown of the server via the HP RA or Remote Control card. | ||
| NTF rAOther30 | 1.3.6.1.4.1.11.2.23.8.0.2901 | The HP RA or Remote Control modem was unable to connect to the TAP paging service modem. | ||
| NTF rAOther33 | 1.3.6.1.4.1.11.2.23.8.0.2902 | The HP RA or Remote Control was unable to connect to the TAP paging service. | ||
| NTF rAOther34 | 1.3.6.1.4.1.11.2.23.8.0.2903 | The HP RA or Remote Control was unable to log on to the TAP paging service. | ||
| NTF rAOther36 | 1.3.6.1.4.1.11.2.23.8.0.2904 | The HP RA or Remote Control pager message was rejected by the TAP paging service. | ||
| NTF rAOther37 | 1.3.6.1.4.1.11.2.23.8.0.2905 | The HP RA or Remote Control email notification message was not sent correctly. | ||
| NTF rAOther38 | 1.3.6.1.4.1.11.2.23.8.0.2906 | A modem error has been detected on the remote management card. | ||
| NTF rAOther39 | 1.3.6.1.4.1.11.2.23.8.0.2907 | TopTools Remote Control Card memory test started | ||
| NTF rAOther40 | 1.3.6.1.4.1.11.2.23.8.0.2908 | TopTools Remote Control Card memory test completed | ||
| NTF rAOther41 | 1.3.6.1.4.1.11.2.23.8.0.2909 | TopTools Remote Control Card memory test stopped by user | ||
| NTF rAOther42 | 1.3.6.1.4.1.11.2.23.8.0.2910 | TopTools Remote Control Card memory test error | ||
| NTF rAOther43 | 1.3.6.1.4.1.11.2.23.8.0.2911 | TopTools Remote Control Card started | ||
| NTF rAOther44 | 1.3.6.1.4.1.11.2.23.8.0.2912 | TopTools Remote Control Card detects a serious internal error that prevents normal operation of the card | ||
| NTF rAOther45 | 1.3.6.1.4.1.11.2.23.8.0.2913 | The firmware on the TopTools Remote Control has been updated | ||
| NTF rAOther46 | 1.3.6.1.4.1.11.2.23.8.0.2914 | The TopTools Remote Control backup battery has discharged to a level where it will not be able to power the card | ||
| NTF rAOther47 | 1.3.6.1.4.1.11.2.23.8.0.2915 | The battery on the TopTools Remote Control card is disconnected | ||
| NTF rAOther48 | 1.3.6.1.4.1.11.2.23.8.0.2916 | Remote Control Card: DHCP has assigned a new IP address | ||
| NTF rAOther27 | 1.3.6.1.4.1.11.2.23.8.0.3408 | Integrated RA configuration reset to defaults | ||
| NTF rAOther11 | 1.3.6.1.4.1.11.2.23.8.0.3602 | A remote user has executed a remote hard reset on the server via the HP RA or Remote Control. | ||
| NTF rAOther14 | 1.3.6.1.4.1.11.2.23.8.0.3603 | A remote user has executed a remote power up of the server via the HP RA or Remote Control card. | ||
| NTF rAOther28 | 1.3.6.1.4.1.11.2.23.8.0.4408 | TopTools Remote Control card configuration was corrupted and has been restored to default settings. | ||
| NTF rAOther15 | 1.3.6.1.4.1.11.2.23.8.0.4603 | Automatic power shutdown due to critical condition. | ||
| NTF rAOther16 | 1.3.6.1.4.1.11.2.23.8.0.5603 | Front panel power down. | ||
| hpnr | 1.3.6.1.4.1.16 | |||
| hpNetRAID | 1.3.6.1.4.1.16.1 | |||
| hpNetRaidMib | 1.3.6.1.4.1.16.1.1 | |||
| raidTraps | 1.3.6.1.4.1.16.1.1.200 | |||
| adaptec | 1.3.6.1.4.1.795 | |||
| storagemanagement | 1.3.6.1.4.1.795.2 | |||
| cyclone | 1.3.6.1.4.1.795.2.5 | |||
| NTF sCSISmart22 | 1.3.6.1.4.1.795.2.5.0.126 | Aspi: initializing | ||
| cycTraps | 1.3.6.1.4.1.795.2.5.9000 | |||
| adaptecRaid | 1.3.6.1.4.1.795.3 | |||
| adaptecNm | 1.3.6.1.4.1.795.4 | |||
| adaptecNmScsiStatus | 1.3.6.1.4.1.795.4.1 | |||
| NTF adaptecSCSI1 | 1.3.6.1.4.1.795.4.1.0.8193 | Device Database has been corrupted. | ||
| NTF adaptecSCSI3 | 1.3.6.1.4.1.795.4.1.0.8194 | SCSI Status agent was unloaded from a NetWare Server. | ||
| NTF adaptecSCSI5 | 1.3.6.1.4.1.795.4.1.0.8196 | One of the SCSI HBAs can no longer be detected by the SCSI Status agent. | ||
| NTF adaptecSCSI7 | 1.3.6.1.4.1.795.4.1.0.8197 | A Host Adapter which has failed, has become accessible again. | ||
| NTF adaptecSCSI9 | 1.3.6.1.4.1.795.4.1.0.8198 | A new SCSI Host Bus Adapter has been discovered or device database has been cleared. | ||
| NTF adaptecSCSI11 | 1.3.6.1.4.1.795.4.1.0.8199 | One of the SCSI devices installed on the server can no longer be detected by the SCSI Status agent. | ||
| NTF adaptecSCSI13 | 1.3.6.1.4.1.795.4.1.0.8200 | A SCSI device which has failed, has become accessible again. | ||
| NTF adaptecSCSI15 | 1.3.6.1.4.1.795.4.1.0.8201 | A new SCSI device has been discovered. | ||
| NTF adaptecSCSI17 | 1.3.6.1.4.1.795.4.1.0.8205 | The SCSI Status agent detected that the Host Bus Adapter has been changed. | ||
| NTF adaptecSCSI21 | 1.3.6.1.4.1.795.4.1.0.8206 | The SCSI Status agent detected that a SCSI device installed on the server has been changed. | ||
| NTF adaptecSCSI19 | 1.3.6.1.4.1.795.4.1.0.8208 | The SCSI Status agent sent a request to an HBA and the request never completed. | ||
| NTF adaptecSCSI23 | 1.3.6.1.4.1.795.4.1.0.8209 | The SCSI Status agent sent a request to a SCSI device and the request never completed. | ||
| NTF adaptecSCSI2 | 1.3.6.1.4.1.795.4.1.0.18193 | Device Database has been corrupted. | ||
| NTF adaptecSCSI4 | 1.3.6.1.4.1.795.4.1.0.18194 | SCSI Status agent was unloaded from a NetWare Server. | ||
| NTF adaptecSCSI6 | 1.3.6.1.4.1.795.4.1.0.18196 | One of the SCSI HBAs can no longer be detected by the SCSI Status agent. | ||
| NTF adaptecSCSI8 | 1.3.6.1.4.1.795.4.1.0.18197 | A Host Adapter which has failed, has become accessible again. | ||
| NTF adaptecSCSI10 | 1.3.6.1.4.1.795.4.1.0.18198 | A new SCSI Host Bus Adapter has been discovered or device database has been cleared. | ||
| NTF adaptecSCSI12 | 1.3.6.1.4.1.795.4.1.0.18199 | One of the SCSI devices installed on the server can no longer be detected by the SCSI Status agent. | ||
| NTF adaptecSCSI14 | 1.3.6.1.4.1.795.4.1.0.18200 | A SCSI device which has failed, has become accessible again. | ||
| NTF adaptecSCSI16 | 1.3.6.1.4.1.795.4.1.0.18201 | A new SCSI device has been discovered. | ||
| NTF adaptecSCSI18 | 1.3.6.1.4.1.795.4.1.0.18205 | The SCSI Status agent detected that the Host Bus Adapter has been changed. | ||
| NTF adaptecSCSI22 | 1.3.6.1.4.1.795.4.1.0.18206 | The SCSI Status agent detected that a SCSI device installed on the server has been changed. | ||
| NTF adaptecSCSI20 | 1.3.6.1.4.1.795.4.1.0.18208 | The SCSI Status agent sent a request to an HBA and the request never completed. | ||
| NTF adaptecSCSI24 | 1.3.6.1.4.1.795.4.1.0.18209 | The SCSI Status agent sent a request to a SCSI device and the request never completed. | ||
| raidproducts | 1.3.6.1.4.1.795.10 | |||
| aac | 1.3.6.1.4.1.795.10.1 | |||
| aac_hpn | 1.3.6.1.4.1.795.10.1.50 | |||
| symbios | 1.3.6.1.4.1.1123 | |||
| coloradosprings | 1.3.6.1.4.1.1123.3 | |||
| scsi | 1.3.6.1.4.1.1123.3.1 | |||
| symc8xx | 1.3.6.1.4.1.1123.3.1.2 | |||
| symTrap | 1.3.6.1.4.1.1123.3.1.2.2 | |||
| eMylex1 | 1.3.6.1.4.1.1608 | |||
| eMylex2 | 1.3.6.1.4.1.1608.1 | |||
| eMylex3 | 1.3.6.1.4.1.1608.1.1 | |||
| eMylex4 | 1.3.6.1.4.1.1608.1.1.1 | |||
| eMylex5 | 1.3.6.1.4.1.1608.1.1.1.9 | |||
| eMylexRaidEventInformation | 1.3.6.1.4.1.1608.1.1.1.9.1 | |||
| dmtfStd | 1.3.6.1.4.1.1608.1.1.1.9.1.1 | |||
| dmtfComponents | 1.3.6.1.4.1.1608.1.1.1.9.1.1.1 | |||
| dmtfGroups | 1.3.6.1.4.1.1608.1.1.1.9.1.1.1.1 |
RFC description
HP enterprise MIB defining trap/alarm notifications for HP network devices; vendor-private.
Start monitoring HP servers and storage systems, incl. Adaptec-based storage controllers (misc. traps) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.