| OID symbolic | OID numeric | Type | Access | Description |
| hpicfSyslogMIB | 1.3.6.1.4.1.11.2.14.14.1 | | | The MIB module for configuring and
monitoring Syslog applications.
The HP Syslog application sends Syslog messages. |
| hpicfSyslogNotifications | 1.3.6.1.4.1.11.2.14.14.1.0 | | | |
| NTF hpicfSyslogStatusChanged | 1.3.6.1.4.1.11.2.14.14.1.0.1 | | | This notification is sent when any of the objects
listed are accessed. For example, when the first server
address is entered, the application
starts [hpicfSyslogOperationsStatus is ''started'' ]. When
the last server address is removed, the Syslog application
stops [hpicfSyslogOperationsStatus is ''stopped''].
The value of hpicfSyslogOperationsStatus will be the
new status of the Syslog application after the change.
Another example, when a server address is added, a
notification is sent indicating the index used to store
the row information, as well as the address type,
the address itself, the description if given , and the
row status. |
| hpicfSyslogObjects | 1.3.6.1.4.1.11.2.14.14.1.1 | | | |
| hpicfSyslogControlTable | 1.3.6.1.4.1.11.2.14.14.1.1.1 | | not-accessible | A table containing the configuration parameters
pertaining to the hpicfSyslog applications serviced by an
SNMP agent. |
| hpicfSyslogControlEntry | 1.3.6.1.4.1.11.2.14.14.1.1.1.1 | | not-accessible | The configuration parameters pertaining to a Syslog
application. |
| I32 hpicfSyslogControlIndex | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.1 | Integer32 | not-accessible | The Index that uniquely identifies the Syslog
application in the hpicfSyslogControlTable.
The value of the index for a Syslog application
may not be the same across system reboots.
Users and applications will need to determine
the index of a Syslog application after system
reboots.
Initial implementation allows integers (1..6). |
| STR hpicfSyslogControlDescr | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.2 | SnmpAdminString | read-create | A user definable description of the Syslog application.
This description could be used by Syslog management
applications e.g. in reports or in user interfaces.
For the description to be persistent across reboots, the
conceptual row must be in the 'active' state.
Also, refer to note in hpicfSyslogControlRowStatus, for
additional limitations. |
| IPt hpicfSyslogControlBindAddrType | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.3 | InetAddressType | read-create | The type of Internet address which follows
in hpicfSyslogControlBindAddr.
Currently only IPv4 is supported. |
| IP hpicfSyslogControlBindAddr | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.4 | InetAddress | read-create | The specific address the Syslog sender will bind to.
The format of the address is specified by the
corresponding hpicfSyslogControlBindAddrType object. |
| ROW hpicfSyslogControlRowStatus | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.5 | RowStatus | read-create | This object is used to create, modify and delete rows in
the hpicfSyslogControlTable.
The value of hpicfSyslogControlDescr can be changed
when this object is in state ''active'' or in
''notInService''.
The other objects in a row can be modified only when the
value of this object in the corresponding conceptual row
is not ''active''. Thus to modify one or more of the
objects in this conceptual row,
a. change the row status to ''notInService'',
b. change the values of the row
c. change the row status to ''active''
The hpicfSyslogControlRowStatus may be changed to
''active'' if all the managed objects in the conceptual
row with MAX-ACCESS read-create have been assigned valid
values.
The information in each conceptual row is only persist
across reboots if the row status is 'active'. |
| T/F hpicfSyslogControlBindAddrIsOobm | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.6 | TruthValue | read-create | This object indicates the specific address to which
Syslog sender will bind is on OOBM interface. This
mib object will be applicable only if there is a
physical OOBM port on the device. |
| INT hpicfSyslogControlSmmLog | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.7 | INTEGER | read-create | This object is applicable for a device with a standby management
module like 8200zl. When the value of this object is set to
enabled, all the log messages from the standby management
module(SMM) will be sent to the Syslog server. If the value is
disabled, the log messages from the standby management module
will not be sent to the Syslog server. By default, this is
disabled. |
| INT hpicfSyslogControlTransportProtocol | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.8 | INTEGER | read-write | The transport protocol used for the connection to the Syslog server
associated with this row. The default value is UDP. |
| INE hpicfSyslogControlDestinationPort | 1.3.6.1.4.1.11.2.14.14.1.1.1.1.9 | InetPortNumber | read-write | The socket port used by the transport protocol to connect to the
Syslog server associated with this row. The default Syslog port
for UDP is 514, for TCP is 1470, and for TLS is 6514. |
| hpicfSyslogOperations | 1.3.6.1.4.1.11.2.14.14.1.1.2 | | | |
| C32 hpicfSyslogOperationsMsgsTransmittedEx | 1.3.6.1.4.1.11.2.14.14.1.1.2.1 | Counter32 | read-only | The number of messages transmitted by the Syslog
sender. This does not include the messages that could
not be queued for transmission by the hpicfSyslog sender.
Discontinuities in the value of this counter can
occur at re-initialization of the management system,
and at other times as indicated by the value of
hpicfSyslogOperationsCounterDiscontinuityTime. |
| C32 hpicfSyslogOperationsMsgsDropped | 1.3.6.1.4.1.11.2.14.14.1.1.2.2 | Counter32 | read-only | The number of messages that could not be queued
for transmission by the Syslog sender.
Discontinuities in the value of this counter can
occur at re-initialization of the management system,
and at other times as indicated by the value of
hpicfSyslogOperationsCounterDiscontinuityTime. |
| TIM hpicfSyslogOperationsLastMsgTransmittedTime | 1.3.6.1.4.1.11.2.14.14.1.1.2.3 | TimeStamp | read-only | The value of sysUpTime when the last message
was transmitted by the hpicfSyslog sender.
If no messages have been transmitted by this Syslog
application, since the last re-initialization of the local
management subsystem, then this object will have a
zero value. |
| TIM hpicfSyslogOperationsStartTime | 1.3.6.1.4.1.11.2.14.14.1.1.2.4 | TimeStamp | read-only | The value of sysUpTime when this Syslog application was
started. |
| STR hpicfSyslogOperationsLastError | 1.3.6.1.4.1.11.2.14.14.1.1.2.5 | SnmpAdminString | read-only | A description of the last error related to sending
a Syslog message that was encountered by this Syslog
application.
If no error has been encountered by this Syslog
application then the value of this object will be a
zero-length string.
If no error has been encountered by this Syslog
application since the last re-initialization of the
local management subsystem then the value of this
object will be a zero-length string. |
| TIM hpicfSyslogOperationsLastErrorTime | 1.3.6.1.4.1.11.2.14.14.1.1.2.6 | TimeStamp | read-only | The value of sysUpTime when the last error was
encountered.
If no error has been encountered by this Syslog
application since the last re-initialization of the
local management subsystem, then this object will
have a zero value. |
| TIM hpicfSyslogOperationsCounterDiscontinuityTime | 1.3.6.1.4.1.11.2.14.14.1.1.2.7 | TimeStamp | read-only | The value of sysUpTime on the most recent occasion
at which any one or more of this Syslog application's
counters, viz., counters with OID prefix
'hpicfSyslogOperationsMsgsTransmitted' or
'hpicfSyslogOperationsMsgsDropped' suffered a
discontinuity.
If no such discontinuities have occurred since the
last re-initialization of the local management
subsystem, then this object will have a zero value. |
| INT hpicfSyslogOperationsStatus | 1.3.6.1.4.1.11.2.14.14.1.1.2.8 | INTEGER | read-only | The status of the Syslog application. |
| hpicfSyslogPriority | 1.3.6.1.4.1.11.2.14.14.1.1.3 | | | |
| HPI hpicfSyslogPriorityFacility | 1.3.6.1.4.1.11.2.14.14.1.1.3.1 | HpicfSyslogFacility | read-write | The facility value of this entry. This value will
be returned in all Syslog message, regardless of
the process/daemon that originates the message. |
| HPI hpicfSyslogPrioritySeverity | 1.3.6.1.4.1.11.2.14.14.1.1.3.2 | HpicfSyslogSeverity | read-write | The severity value of this entry. Used to filter
'event' messages. |
| STR hpicfSyslogPriorityDescr | 1.3.6.1.4.1.11.2.14.14.1.1.3.3 | SnmpAdminString | read-write | A textual description of this priority entry. |
| HPI hpicfSyslogSystemModule | 1.3.6.1.4.1.11.2.14.14.1.1.3.4 | HpicfSyslogSystemModule | read-write | A system module value of this entry. Used to filter
'event' messages. |
| HPI hpicfSyslogOriginId | 1.3.6.1.4.1.11.2.14.14.1.1.3.5 | HpicfSyslogOriginId | read-write | Specifies the content of a HOSTNAME field in the HEADER of
a syslog message. This content can be either an IP address,
a hostname or none.
A value of (1) indicates the IP address of the outgoing interface.
A value of (2) indicates the hostname of the device.
A value of (3) indicates NILVALUE. Here, NILVALUE is defined as '-'. |
| hpicfSyslogStatistics | 1.3.6.1.4.1.11.2.14.14.1.1.4 | | | |
| hpicfSyslogGeneralStatistics | 1.3.6.1.4.1.11.2.14.14.1.1.4.1 | | | |
| C32 hpicfSyslogGeneralLogSent | 1.3.6.1.4.1.11.2.14.14.1.1.4.1.1 | Counter32 | read-only | Number of Syslog messages sent by the Syslog sender. |
| C32 hpicfSyslogGeneralLogRecv | 1.3.6.1.4.1.11.2.14.14.1.1.4.1.2 | Counter32 | read-only | Number of Syslog messages received by the Syslog
Server. |
| C32 hpicfSyslogGeneralLogRelay | 1.3.6.1.4.1.11.2.14.14.1.1.4.1.3 | Counter32 | read-only | The number of messages processed by the Syslog relay. |
| C32 hpicfSyslogGeneralSendError | 1.3.6.1.4.1.11.2.14.14.1.1.4.1.4 | Counter32 | read-only | Number of Syslog messages that failed during the
send process and this failed message will be
buffered for the retransmission process. |
| C32 hpicfSyslogGeneralLogResend | 1.3.6.1.4.1.11.2.14.14.1.1.4.1.5 | Counter32 | read-only | Number of Syslog messages re-transmitted successfully. |
| C32 hpicfSyslogGeneralResendError | 1.3.6.1.4.1.11.2.14.14.1.1.4.1.6 | Counter32 | read-only | Number of Syslog messages that failed during the
retransmission process.The Syslog retransmission
will happen if and only if Syslog send failed
while transmitting the buffered Syslog messages. |
| C32 hpicfSyslogGeneralLogBuffered | 1.3.6.1.4.1.11.2.14.14.1.1.4.1.7 | Counter32 | read-only | Current number of buffered Syslog messages that
are ready to be transmitted. |
| hpicfSyslogSeverityStatistics | 1.3.6.1.4.1.11.2.14.14.1.1.4.2 | | | |
| hpicfSyslogSeverityCounterInfoTable | 1.3.6.1.4.1.11.2.14.14.1.1.4.2.1 | | not-accessible | A table containing the Syslog severity statistics counter value. |
| hpicfSyslogSeverityCounterInfoEntry | 1.3.6.1.4.1.11.2.14.14.1.1.4.2.1.1 | | not-accessible | The configuration parameters pertaining to a Syslog severity
statistics. |
| I32 hpicfSyslogSeverityTypeIndex | 1.3.6.1.4.1.11.2.14.14.1.1.4.2.1.1.1 | Integer32 | not-accessible | The Index that uniquely identifies the Syslog
severity type. |
| HPI hpicfSyslogSeverityType | 1.3.6.1.4.1.11.2.14.14.1.1.4.2.1.1.2 | HpicfSyslogSeverity | read-only | The severity type for all the Syslog messages. |
| C32 hpicfSyslogSeverityCounter | 1.3.6.1.4.1.11.2.14.14.1.1.4.2.1.1.3 | Counter32 | read-only | Number of messages transmitted per severity. |
| hpicfSyslogFacilityStatistics | 1.3.6.1.4.1.11.2.14.14.1.1.4.3 | | | |
| hpicfSyslogFacilityCounterInfoTable | 1.3.6.1.4.1.11.2.14.14.1.1.4.3.1 | | not-accessible | A table containing the Syslog facility statistics counter values. |
| hpicfSyslogFacilityCounterInfoEntry | 1.3.6.1.4.1.11.2.14.14.1.1.4.3.1.1 | | not-accessible | The configuration parameters pertaining to a Syslog facility
statistics. |
| I32 hpicfSyslogfacilityCounterIndex | 1.3.6.1.4.1.11.2.14.14.1.1.4.3.1.1.1 | Integer32 | not-accessible | The Index that uniquely identifies the Syslog
facility. |
| HPI hpicfSyslogfacilityType | 1.3.6.1.4.1.11.2.14.14.1.1.4.3.1.1.2 | HpicfSyslogFacility | read-only | The facility type for all the Syslog messages. |
| C32 hpicfSyslogfacilityCounter | 1.3.6.1.4.1.11.2.14.14.1.1.4.3.1.1.3 | Counter32 | read-only | Number of Syslog messages transmitted per facilty. |
| hpicfSyslogLogMsgOptions | 1.3.6.1.4.1.11.2.14.14.1.1.5 | | | |
| T/F hpicfSyslogClearLog | 1.3.6.1.4.1.11.2.14.14.1.1.5.1 | TruthValue | read-write | Setting this object to TRUE will erase all event log messages.
This object always return FALSE when read. |
| T/F hpicfSyslogSecClearLog | 1.3.6.1.4.1.11.2.14.14.1.1.5.2 | TruthValue | read-write | Setting this object to TRUE will erase all security-related
log messages. This object always return FALSE when read. |
| hpicfSyslogServerStatisticsTable | 1.3.6.1.4.1.11.2.14.14.1.1.6 | | not-accessible | A table containing the statistical information
pertaining to each Syslog server indexed by
hpicfSyslogControlIndex. |
| hpicfSyslogServerStatisticsEntry | 1.3.6.1.4.1.11.2.14.14.1.1.6.1 | | not-accessible | The configuration parameters pertaining to a Syslog
application. |
| C32 hpicfSyslogServerLogSent | 1.3.6.1.4.1.11.2.14.14.1.1.6.1.1 | Counter32 | read-only | Number of Syslog messages sent by the Syslog sender. |
| C32 hpicfSyslogServerLogRecv | 1.3.6.1.4.1.11.2.14.14.1.1.6.1.2 | Counter32 | read-only | Number of Syslog messages received by the Syslog
Server. |
| C32 hpicfSyslogServerLogRelay | 1.3.6.1.4.1.11.2.14.14.1.1.6.1.3 | Counter32 | read-only | The number of messages processed by the Syslog relay. |
| C32 hpicfSyslogServerSendError | 1.3.6.1.4.1.11.2.14.14.1.1.6.1.4 | Counter32 | read-only | Number of Syslog messages that failed during the
send process and this failed message will be
buffered for the retransmission process. |
| C32 hpicfSyslogServerLogResend | 1.3.6.1.4.1.11.2.14.14.1.1.6.1.5 | Counter32 | read-only | Number of Syslog messages re-transmitted successfully. |
| C32 hpicfSyslogServerResendError | 1.3.6.1.4.1.11.2.14.14.1.1.6.1.6 | Counter32 | read-only | Number of Syslog messages that failed during the
retransmission process.The Syslog retransmission
will happen if and only if Syslog send failed
while transmitting the buffered Syslog messages. |
| C32 hpicfSyslogServerLogBuffered | 1.3.6.1.4.1.11.2.14.14.1.1.6.1.7 | Counter32 | read-only | Current number of buffered Syslog messages that
are ready to be transmitted. |
| hpicfSyslogAlerts | 1.3.6.1.4.1.11.2.14.14.1.1.7 | | | |
| hpicfSyslogAlertsTable | 1.3.6.1.4.1.11.2.14.14.1.1.7.1 | | not-accessible | A table of entries containing configuration information
for transmitting alerts in Syslog messages. |
| hpicfSyslogAlertsEntry | 1.3.6.1.4.1.11.2.14.14.1.1.7.1.1 | | not-accessible | An entry in the 'hpicfSyslogAlertsTable'. |
| INT hpicfSyslogAlertIndex | 1.3.6.1.4.1.11.2.14.14.1.1.7.1.1.1 | INTEGER | not-accessible | The index which uniquely identifies a row in
the 'hpicfSyslogAlertsTable'.
runningCfgChg - the alert type indicating that
a change was made made to the
switch's running configuration. |
| INT hpicfSyslogAlertAdminStatus | 1.3.6.1.4.1.11.2.14.14.1.1.7.1.1.2 | INTEGER | read-write | Indicates whether the Syslog application is permitted
to generate given type of alerts in transmitted
Syslog messages. Default is disabled. |
| U32 hpicfSyslogAlertTransmitInterval | 1.3.6.1.4.1.11.2.14.14.1.1.7.1.1.3 | Unsigned32 | read-write | Specifies the transmission interval in seconds for
sending alerts in Syslog messages. Only one Syslog
message is allowed for transmission within this time
interval. Default value is 0, indicating there is no
rate limit for alerts transmission. |
| hpicfSyslogConformance | 1.3.6.1.4.1.11.2.14.14.1.3 | | | |
| hpicfSyslogGroups | 1.3.6.1.4.1.11.2.14.14.1.3.1 | | | |
| hpicfSyslogOperationsGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.1 | | | A collection of objects providing message related
statistics. |
| hpicfSyslogControlGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.2 | | | A collection of objects representing the run time
parameters for the Syslog applications. |
| hpicfSyslogPriorityGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.3 | | | A collection of objects representing the priority
groupings of hpicfSyslog messages. |
| hpicfSyslogNotificationGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.5 | | | A collection of notifications about the operational
state of a Syslog application. |
| hpicfSyslogControlGroupOobm | 1.3.6.1.4.1.11.2.14.14.1.3.1.6 | | | A collection of objects representing the run time
parameters for the OOBM aware Syslog applications. |
| hpicfSyslogGeneralStatisticsGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.7 | | | A collection of objects representing the general statistics
counter information. |
| hpicfSyslogSeverityStatisticsGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.8 | | | A collection of objects representing the severity statistics
counter information. |
| hpicfSyslogFacilityStatisticsGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.9 | | | A collection of objects representing the facility statistics
counter information. |
| hpicfSyslogControlGroupSmm | 1.3.6.1.4.1.11.2.14.14.1.3.1.10 | | | A collection of objects representing the log message for the
standby module. |
| hpicfSyslogLogMsgOptionsGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.11 | | | A collection of objects representing the log message information. |
| hpicfSyslogControlTransportGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.12 | | | A collection of objects representing the run time
parameters for the transport applications. |
| hpicfSyslogServerStatisticsGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.13 | | | A collection of objects representing the server specific
statistics counter information. |
| hpicfSyslogPriorityGroup1 | 1.3.6.1.4.1.11.2.14.14.1.3.1.14 | | | A collection of object for Syslog priority. |
| hpicfSyslogAlertsGroup | 1.3.6.1.4.1.11.2.14.14.1.3.1.15 | | | A collection of objects representing Syslog alerts information. |
| hpicfSyslogOriginIdGroup1 | 1.3.6.1.4.1.11.2.14.14.1.3.1.16 | | | An object for syslog origin ID. |
| hpicfSyslogLogMsgOptionsGroup1 | 1.3.6.1.4.1.11.2.14.14.1.3.1.17 | | | A collection of objects representing the log message information. |
| hpicfSyslogCompliances | 1.3.6.1.4.1.11.2.14.14.1.3.2 | | | |
| hpicfSyslogFullCompliance1 | 1.3.6.1.4.1.11.2.14.14.1.3.2.1 | | | The compliance statement for SNMP entities which
implement the SYSLOG-MIB with support for writable
objects and notifications. Such an implementation can
be both monitored and configured via SNMP. It can
also send notifications about change in the
operational status of the Syslog application. |
| hpicfSyslogFullCompliance2 | 1.3.6.1.4.1.11.2.14.14.1.3.2.2 | | | The compliance statement for SNMP entities which
implement the SYSLOG-MIB with support for writable
objects. Such an implementation can
be both monitored and configured via SNMP. |
| hpicfSyslogReadOnlyCompliance1 | 1.3.6.1.4.1.11.2.14.14.1.3.2.4 | | | The compliance statement for SNMP entities which
implement the hpicfSyslog MIB without support
for read-write (i.e. in read-only mode). It can
also send notifications about change in the
operational status of the Syslog application. |
| hpicfSyslogReadOnlyCompliance2 | 1.3.6.1.4.1.11.2.14.14.1.3.2.5 | | | The compliance statement for SNMP entities which
implement the hpicfSyslog MIB without support
for read-write (i.e. in read-only mode). |
| hpicfSyslogNotificationCompliance | 1.3.6.1.4.1.11.2.14.14.1.3.2.7 | | | The compliance statement for SNMP entities
which implement the SYSLOG-MIB and support
only notifications about change in the
operational status of a Syslog application. |
| hpicfSyslogFullComplianceOobm | 1.3.6.1.4.1.11.2.14.14.1.3.2.8 | | | The compliance statement for Syslog server configuration
with support for OOBM. |
| hpicfSyslogStatisticsCompliance | 1.3.6.1.4.1.11.2.14.14.1.3.2.9 | | | The compliance statement for SNMP entities
which implement the Syslog statistics. |
| hpicfSyslogSmmLogMsgCompliance | 1.3.6.1.4.1.11.2.14.14.1.3.2.10 | | | The compliance statement for Syslog
log messages for standby module. |
| hpicfSyslogTransportCompliance | 1.3.6.1.4.1.11.2.14.14.1.3.2.11 | | | The compliance statement for Syslog
transport . |
| hpicfSyslogPriorityCompliance | 1.3.6.1.4.1.11.2.14.14.1.3.2.12 | | | The compliance statement for Syslog
priority . |
| hpicfSyslogServerStatisticsCompliance | 1.3.6.1.4.1.11.2.14.14.1.3.2.13 | | | The compliance statement for syslog
server statistics . |
| hpicfSyslogAlertsCompliance | 1.3.6.1.4.1.11.2.14.14.1.3.2.14 | | | The compliance statement for Syslog alerts. |
| hpicfSyslogOriginIdCompliance | 1.3.6.1.4.1.11.2.14.14.1.3.2.15 | | | The compliance statement for syslog
origin id. |
| hpicfSyslogSmmLogMsgCompliance1 | 1.3.6.1.4.1.11.2.14.14.1.3.2.16 | | | The compliance statement for Syslog
log messages for standby module. |