All MIBs › HHMSAGENT-MIB
Category: Domain: Environmental Monitoring
Description: Honeywell HMS SNMP agent MIB providing management objects for Honeywell HMS industrial communication gateways.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HHMSAGENT-MIB?
HHMSAGENT-MIB is a Honeywell-specific MIB for the SNMP agent embedded in Honeywell HMS (Honeywell Management System) industrial communication gateways, which bridge field-level industrial protocols to IP networks. It generally exposes management objects covering the gateway's own status and configuration rather than a broader third-party device's data. Its primary monitoring value would be in confirming that the gateway's software agent and underlying hardware are alive and functioning — the kind of module used to check basic device/process health on an industrial gateway rather than deep performance counters. No module description or sample objects were available for this MIB, so its exact object structure cannot be described in further detail. It is typically deployed in industrial automation environments where Honeywell HMS gateways connect field devices into a plant's broader SNMP-based network management system. Engineers can download the HHMSAGENT-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in HHMSAGENT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- AKCP environmental monitoring devices (sensorProbe/securityProbe series)
Monitoring Examples
No sample objects were provided for this MIB, and without a module description or concrete object names, a specific realistic monitoring scenario cannot be honestly constructed; in general, a MIB of this type would be polled to confirm the gateway's agent process is responsive and reporting basic operational state.
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| IpAddress | |
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| akcp | 1.3.6.1.4.1.3854 | |||
| hhmsagent | 1.3.6.1.4.1.3854.1 | |||
| NTF hhmsUnknownStatus | 1.3.6.1.4.1.3854.1.0.0 | hhmsagent status went to Unknown | ||
| NTF hhmsNormalStatus | 1.3.6.1.4.1.3854.1.0.1 | hhmsagent status is Normal | ||
| NTF hhmsWarningStatus | 1.3.6.1.4.1.3854.1.0.2 | hhmsagent status went to Warning | ||
| NTF hhmsCriticalStatus | 1.3.6.1.4.1.3854.1.0.3 | hhmsagent status went to Critical | ||
| NTF hhmsDownStatus | 1.3.6.1.4.1.3854.1.0.4 | hhmsagent status went to Disabled | ||
| NTF hhmsTemperatureStatus | 1.3.6.1.4.1.3854.1.0.10 | Temperature sensor trap | ||
| NTF hhmsHumidityStatus | 1.3.6.1.4.1.3854.1.0.20 | Humidity sensor trap | ||
| NTF hhmsSwitchStatus | 1.3.6.1.4.1.3854.1.0.30 | Switch sensor trap | ||
| NTF hhmsPowerMonitorStatus | 1.3.6.1.4.1.3854.1.0.40 | Power Monitor sensor trap | ||
| hhmsAgentSummary | 1.3.6.1.4.1.3854.1.1 | |||
| STR hhmsAgentLocation | 1.3.6.1.4.1.3854.1.1.1 | DisplayString | read-write | The Agent location |
| INT hhmsAgentStatus | 1.3.6.1.4.1.3854.1.1.2 | INTEGER | read-only | The current status of this Agent. The status of the agent is the worst status of all the sensors usder the control of this agent. |
| INT hhmsNumberBadSensors | 1.3.6.1.4.1.3854.1.1.4 | INTEGER | read-only | How many sensors controlled by this agent are not functioning properly |
| STR hhmsLocationBadSensor | 1.3.6.1.4.1.3854.1.1.5 | DisplayString | read-only | The Location of the first bad sensor controlled by this agent. |
| STR hhmsAgentManufName | 1.3.6.1.4.1.3854.1.1.6 | DisplayString | read-only | The manufacturers name |
| STR hhmsAgentHelpUrl | 1.3.6.1.4.1.3854.1.1.7 | DisplayString | read-only | The URL of the web based help |
| INT hhmsAgentHtmlView | 1.3.6.1.4.1.3854.1.1.8 | INTEGER | read-write | Which view of the sensors the user is served via the web server |
| STR hhmsAgentHtmlStandardTitle | 1.3.6.1.4.1.3854.1.1.9 | DisplayString | read-write | The titles of the standard html view |
| STR hhmsAgentHtmlStandardButton | 1.3.6.1.4.1.3854.1.1.10 | DisplayString | read-write | The buttons of the standard html view |
| hhmsSensor | 1.3.6.1.4.1.3854.1.2 | |||
| hhmsSensorArrayTable | 1.3.6.1.4.1.3854.1.2.2 | |||
| hhmsSensorArrayEntry | 1.3.6.1.4.1.3854.1.2.2.1 | |||
| IP hhmsSensorArrayHost | 1.3.6.1.4.1.3854.1.2.2.1.1 | IpAddress | read-write | The Host of this sensor, this is the IP address |
| INT hhmsSensorArrayUseDHCP | 1.3.6.1.4.1.3854.1.2.2.1.2 | INTEGER | read-write | To use DHCP enter a 1, to use a static IP address enter a 2 |
| STR hhmsSensorArrayMAC | 1.3.6.1.4.1.3854.1.2.2.1.3 | DisplayString | read-only | The MAC address of this sensor. |
| STR hhmsSensorArraySetCommunity | 1.3.6.1.4.1.3854.1.2.2.1.4 | DisplayString | read-write | The sensorArray community string used for snmp Sets |
| STR hhmsSensorArrayGetCommunity | 1.3.6.1.4.1.3854.1.2.2.1.5 | DisplayString | read-write | The sensorArray community string used for snmp Gets |
| STR hhmsSensorArrayDescription | 1.3.6.1.4.1.3854.1.2.2.1.6 | DisplayString | read-write | A Description of this sensorArray |
| STR hhmsSensorArrayLocation | 1.3.6.1.4.1.3854.1.2.2.1.7 | DisplayString | read-write | The description of the physical location of this sensorArray |
| STR hhmsSensorArrayLastUpdate | 1.3.6.1.4.1.3854.1.2.2.1.8 | DisplayString | read-only | The last time the sensorArray was read |
| INT hhmsSensorArrayStatus | 1.3.6.1.4.1.3854.1.2.2.1.9 | INTEGER | read-only | The current status of this sensorArray |
| INT hhmsSensorArrayOnline | 1.3.6.1.4.1.3854.1.2.2.1.10 | INTEGER | read-only | If this sensorArray is currently online |
| INT hhmsSensorArrayGoOnline | 1.3.6.1.4.1.3854.1.2.2.1.11 | INTEGER | read-write | To put online enter a 1, to take offline enter a 2 |
| INT hhmsSensorArrayReadInterval | 1.3.6.1.4.1.3854.1.2.2.1.12 | INTEGER | read-write | How many seconds between readings of this sensor |
| INT hhmsSensorArrayReceiveTimeout | 1.3.6.1.4.1.3854.1.2.2.1.13 | INTEGER | read-write | How many seconds to wait to receive data from the sensor |
| INT hhmsSensorArrayReceiveRetries | 1.3.6.1.4.1.3854.1.2.2.1.14 | INTEGER | read-write | How many times to retry to receive data before giving up. A -1 means never give up trying |
| INT hhmsSensorArrayVersion | 1.3.6.1.4.1.3854.1.2.2.1.15 | INTEGER | read-only | The version of this SensorArray |
| hhmsSensorArrayTempTable | 1.3.6.1.4.1.3854.1.2.2.1.16 | not-accessible | This table contains the data for every Temperature Sensor in the SensorArray. Each row in the table contains data for a different Temperature Sensor. | |
| hhmsSensorArrayTempEntry | 1.3.6.1.4.1.3854.1.2.2.1.16.1 | not-accessible | This is an entry in the hhmsSensorArrayTempEntry Table | |
| STR hhmsSensorArrayTempDescription | 1.3.6.1.4.1.3854.1.2.2.1.16.1.1 | DisplayString | read-write | A Description of this sensor |
| STR hhmsSensorArrayTempLocation | 1.3.6.1.4.1.3854.1.2.2.1.16.1.2 | DisplayString | read-write | The physical location of this sensor |
| INT hhmsSensorArrayTempDegree | 1.3.6.1.4.1.3854.1.2.2.1.16.1.3 | INTEGER | read-only | The degrees in this sensor |
| INT hhmsSensorArrayTempStatus | 1.3.6.1.4.1.3854.1.2.2.1.16.1.4 | INTEGER | read-only | The current status of this Sensor |
| INT hhmsSensorArrayTempOnline | 1.3.6.1.4.1.3854.1.2.2.1.16.1.5 | INTEGER | read-only | If this Sensor is currently online |
| INT hhmsSensorArrayTempGoOnline | 1.3.6.1.4.1.3854.1.2.2.1.16.1.6 | INTEGER | read-write | To put online enter a 1, to take offline enter a 2 |
| INT hhmsSensorArrayTempHighWarning | 1.3.6.1.4.1.3854.1.2.2.1.16.1.7 | INTEGER | read-write | How hot this sensor gets before it sends a warning |
| INT hhmsSensorArrayTempHighCritical | 1.3.6.1.4.1.3854.1.2.2.1.16.1.8 | INTEGER | read-write | How hot this sensor gets before it sends a critical event |
| INT hhmsSensorArrayTempLowWarning | 1.3.6.1.4.1.3854.1.2.2.1.16.1.9 | INTEGER | read-write | How cold this sensor gets before it sends a warning |
| INT hhmsSensorArrayTempLowCritical | 1.3.6.1.4.1.3854.1.2.2.1.16.1.10 | INTEGER | read-write | How cold this sensor gets before it sends a critical event |
| INT hhmsSensorArrayTempRearm | 1.3.6.1.4.1.3854.1.2.2.1.16.1.11 | INTEGER | read-write | The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down hhmsTempRearm degrees below warning before the status goes to normal |
| INT hhmsSensorArrayTempDegreeType | 1.3.6.1.4.1.3854.1.2.2.1.16.1.12 | INTEGER | read-write | The degrees are in fahrenheit(0) or in celsius(1) |
| INT hhmsSensorArrayTempSensorType | 1.3.6.1.4.1.3854.1.2.2.1.16.1.13 | INTEGER | read-write | The type of temperture sensor |
| INT hhmsSensorArrayTempTestStatus | 1.3.6.1.4.1.3854.1.2.2.1.16.1.14 | INTEGER | read-write | Set the status for test purposes |
| INT hhmsSensorArrayTempTestDegree | 1.3.6.1.4.1.3854.1.2.2.1.16.1.15 | INTEGER | read-write | Enter the degrees in this sensor for test purposes |
| INT hhmsSensorArrayTempIndex | 1.3.6.1.4.1.3854.1.2.2.1.16.1.16 | INTEGER | read-only | The index into the temperature sensor table |
| hhmsSensorArrayHumidityTable | 1.3.6.1.4.1.3854.1.2.2.1.17 | not-accessible | This table contains the data for every Humidity Sensor in the SensorArray. Each row in the table contains data for a different Humidity Sensor. | |
| hhmsSensorArrayHumidityEntry | 1.3.6.1.4.1.3854.1.2.2.1.17.1 | not-accessible | This is an entry in the hhmsSensorArrayHumidityEntry Table | |
| STR hhmsSensorArrayHumidityDescription | 1.3.6.1.4.1.3854.1.2.2.1.17.1.1 | DisplayString | read-write | A Description of this sensor |
| STR hhmsSensorArrayHumidityLocation | 1.3.6.1.4.1.3854.1.2.2.1.17.1.2 | DisplayString | read-write | The physical location of this sensor |
| INT hhmsSensorArrayHumidityPercent | 1.3.6.1.4.1.3854.1.2.2.1.17.1.3 | INTEGER | read-only | The relative humidity percentage measured by this sensor |
| INT hhmsSensorArrayHumidityStatus | 1.3.6.1.4.1.3854.1.2.2.1.17.1.4 | INTEGER | read-only | The current status of this Sensor |
| INT hhmsSensorArrayHumidityOnline | 1.3.6.1.4.1.3854.1.2.2.1.17.1.5 | INTEGER | read-only | If this Sensor is currently online |
| INT hhmsSensorArrayHumidityGoOnline | 1.3.6.1.4.1.3854.1.2.2.1.17.1.6 | INTEGER | read-write | To put online enter a 1, to take offline enter a 2 |
| INT hhmsSensorArrayHumidityHighWarning | 1.3.6.1.4.1.3854.1.2.2.1.17.1.7 | INTEGER | read-write | How high the relative humidity this sensor measures before it sends a warning |
| INT hhmsSensorArrayHumidityHighCritical | 1.3.6.1.4.1.3854.1.2.2.1.17.1.8 | INTEGER | read-write | How high the relative humidity this sensor measures before it becomes critical |
| INT hhmsSensorArrayHumidityLowWarning | 1.3.6.1.4.1.3854.1.2.2.1.17.1.9 | INTEGER | read-write | How low the relative humidity this sensor measures before it sends a warning |
| INT hhmsSensorArrayHumidityLowCritical | 1.3.6.1.4.1.3854.1.2.2.1.17.1.10 | INTEGER | read-write | How low the relative humidity this sensor measures before it becomes critical |
| INT hhmsSensorArrayHumidityRearm | 1.3.6.1.4.1.3854.1.2.2.1.17.1.11 | INTEGER | read-write | The percent relative humidity to rearm the status. For example if status goes from normal to warning, the humidity must go down hhmsHumidityRearm below warning before the status goes to normal |
| INT hhmsSensorArrayHumidityTestStatus | 1.3.6.1.4.1.3854.1.2.2.1.17.1.12 | INTEGER | read-write | Set the status for test purposes |
| INT hhmsSensorArrayHumidityTestPercent | 1.3.6.1.4.1.3854.1.2.2.1.17.1.13 | INTEGER | read-write | Enter the percent of relative humidity in this sensor for test purposes |
| INT hhmsSensorArrayHumidityIndex | 1.3.6.1.4.1.3854.1.2.2.1.17.1.14 | INTEGER | read-only | The index into the Humidity sensor table |
| hhmsSensorArraySwitchTable | 1.3.6.1.4.1.3854.1.2.2.1.18 | not-accessible | This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor. | |
| hhmsSensorArraySwitchEntry | 1.3.6.1.4.1.3854.1.2.2.1.18.1 | not-accessible | This is an entry in the hhmsSensorArraySwitchEntry Table | |
| STR hhmsSensorArraySwitchDescription | 1.3.6.1.4.1.3854.1.2.2.1.18.1.1 | DisplayString | read-write | A Description of this sensor Switch |
| STR hhmsSensorArraySwitchLocation | 1.3.6.1.4.1.3854.1.2.2.1.18.1.2 | DisplayString | read-write | The physical location of this sensor Switch |
| INT hhmsSensorArraySwitchStatus | 1.3.6.1.4.1.3854.1.2.2.1.18.1.3 | INTEGER | read-only | The current status of this Sensor, only input switches have a status |
| INT hhmsSensorArraySwitchOnline | 1.3.6.1.4.1.3854.1.2.2.1.18.1.4 | INTEGER | read-only | If this Sensor is currently online |
| INT hhmsSensorArraySwitchGoOnline | 1.3.6.1.4.1.3854.1.2.2.1.18.1.5 | INTEGER | read-write | To put online enter a 1, to take offline enter a 2 |
| INT hhmsSensorArraySwitchDirection | 1.3.6.1.4.1.3854.1.2.2.1.18.1.6 | INTEGER | read-write | To set a switch to input enter 0. To set a switch to output enter 1 |
| INT hhmsSensorArraySwitchNormalState | 1.3.6.1.4.1.3854.1.2.2.1.18.1.7 | INTEGER | read-write | The normal state of an input switch. If an input switch is in this state it is normal, else it is critical. An open switch senses +5 volts. A closed switch senses 0 volts. |
| INT hhmsSensorArraySwitchOutputLevel | 1.3.6.1.4.1.3854.1.2.2.1.18.1.8 | INTEGER | read-write | An output swith can be set to this level |
| INT hhmsSensorArraySwitchTestState | 1.3.6.1.4.1.3854.1.2.2.1.18.1.9 | INTEGER | read-only | Enter the status of this Sensor for test purposes |
| INT hhmsSensorArraySwitchIndex | 1.3.6.1.4.1.3854.1.2.2.1.18.1.10 | INTEGER | read-only | The index into the Switch sensor table |
| hhmsSensorArraySerialTable | 1.3.6.1.4.1.3854.1.2.2.1.19 | not-accessible | This table contains the data for every Serial Port in the SensorArray. Each row in the table contains data for a different Serial Port. | |
| hhmsSensorArraySerialEntry | 1.3.6.1.4.1.3854.1.2.2.1.19.1 | not-accessible | This is an entry in the hhmsSensorArraySerialEntry Table | |
| STR hhmsSensorArraySerialDescription | 1.3.6.1.4.1.3854.1.2.2.1.19.1.1 | DisplayString | read-write | A Description of this Serial Port |
| STR hhmsSensorArraySerialLocation | 1.3.6.1.4.1.3854.1.2.2.1.19.1.2 | DisplayString | read-write | The physical location of this Serial Port |
| INT hhmsSensorArraySerialStatus | 1.3.6.1.4.1.3854.1.2.2.1.19.1.3 | INTEGER | read-only | The current status of this Serial Port |
| INT hhmsSensorArraySerialOnline | 1.3.6.1.4.1.3854.1.2.2.1.19.1.4 | INTEGER | read-only | If this Serial Port is currently online |
| INT hhmsSensorArraySerialGoOnline | 1.3.6.1.4.1.3854.1.2.2.1.19.1.5 | INTEGER | read-write | To put online enter a 1, to take offline enter a 2 |
| STR hhmsSensorArraySerialData | 1.3.6.1.4.1.3854.1.2.2.1.19.1.6 | DisplayString | read-write | Write sends data, read gets data from this Serial Port |
| INT hhmsSensorArraySerialBaud | 1.3.6.1.4.1.3854.1.2.2.1.19.1.7 | INTEGER | read-write | Choose the baud rate for this serial port |
| INT hhmsSensorArraySerialDataBits | 1.3.6.1.4.1.3854.1.2.2.1.19.1.8 | INTEGER | read-write | Parity bit for this serial port |
| INT hhmsSensorArraySerialParity | 1.3.6.1.4.1.3854.1.2.2.1.19.1.9 | INTEGER | read-write | Parity bit for this serial port |
| INT hhmsSensorArraySerialStop | 1.3.6.1.4.1.3854.1.2.2.1.19.1.10 | INTEGER | read-write | Stop bits for this serial port |
| INT hhmsSensorArraySerialCTS | 1.3.6.1.4.1.3854.1.2.2.1.19.1.11 | INTEGER | read-write | Turn CTS on or off for this serial port |
| INT hhmsSensorArraySerialRTS | 1.3.6.1.4.1.3854.1.2.2.1.19.1.12 | INTEGER | read-write | Turn RTS on or off for this serial port |
| STR hhmsSensorArraySerialConfig | 1.3.6.1.4.1.3854.1.2.2.1.19.1.13 | DisplayString | read-write | A Description of this Serial Port |
| INT hhmsSensorArraySerialIndex | 1.3.6.1.4.1.3854.1.2.2.1.19.1.14 | INTEGER | read-only | The index into the Serial table |
| INT hhmsSensorArrayDebug | 1.3.6.1.4.1.3854.1.2.2.1.20 | INTEGER | read-write | Turn on or off debug messages |
| STR hhmsSensorArrayDebugIP | 1.3.6.1.4.1.3854.1.2.2.1.21 | DisplayString | read-write | The IP address to send debug messages to |
| INT hhmsSensorArrayTrapResend | 1.3.6.1.4.1.3854.1.2.2.1.22 | INTEGER | read-write | If traps for Warning or Error should be resent. Traps for Normal status are sent once |
| INT hhmsSensorArrayTrapResendInterval | 1.3.6.1.4.1.3854.1.2.2.1.23 | INTEGER | read-write | How often to resend mail or Traps. Enter the number of seconds from 15 to 65535. Mail for WARNING and ERROR are resent at this interval. Traps for Normal status are sent once |
| INT hhmsSensorArraySendTraps | 1.3.6.1.4.1.3854.1.2.2.1.24 | INTEGER | read-write | Turn on or off the sending of traps |
| IP hhmsSensorArrayTrapDestination | 1.3.6.1.4.1.3854.1.2.2.1.25 | IpAddress | read-write | The IP address of the trap destination |
| STR hhmsSensorArrayTrapCommunity | 1.3.6.1.4.1.3854.1.2.2.1.26 | DisplayString | read-write | The community string of the trap destination |
| IP hhmsSensorArrayTrapDefaultGateway | 1.3.6.1.4.1.3854.1.2.2.1.27 | IpAddress | read-write | If the trap destination is on another network, enter the IP address of the router |
| INT hhmsSensorArrayTrapUseDefaultGateway | 1.3.6.1.4.1.3854.1.2.2.1.28 | INTEGER | read-write | If the trap destination uses the default gateway |
| STR hhmsSensorArrayTrapDestinationMac | 1.3.6.1.4.1.3854.1.2.2.1.29 | DisplayString | read-write | If the trap destination MAC address |
| INT hhmsSensorArraySendMail | 1.3.6.1.4.1.3854.1.2.2.1.30 | INTEGER | read-write | Turn on or off the sending of Mail |
| STR hhmsSensorArrayMailRecpt | 1.3.6.1.4.1.3854.1.2.2.1.31 | DisplayString | read-write | The email address of the Recipient |
| STR hhmsSensorArrayMailFrom | 1.3.6.1.4.1.3854.1.2.2.1.32 | DisplayString | read-write | The email address of the Sender |
| IP hhmsSensorArrayMailSmpt | 1.3.6.1.4.1.3854.1.2.2.1.33 | IpAddress | read-write | The IP Address of the SMPT server. Note: This must be in dotted decimal form |
| IP hhmsSensorArrayMailGateway | 1.3.6.1.4.1.3854.1.2.2.1.34 | IpAddress | read-write | If the smpt server is on another network, enter the IP address of the router |
| INT hhmsSensorArrayMailUseGateway | 1.3.6.1.4.1.3854.1.2.2.1.35 | INTEGER | read-write | If the mail uses the default gateway |
| INT hhmsSensorArrayMailResendInterval | 1.3.6.1.4.1.3854.1.2.2.1.36 | INTEGER | read-write | How often to resend mail or Traps. Enter the number of seconds from 10 to 65535. Mail for WARNING and ERROR are resent at this interval. Mail for Normal status are sent once |
| INT hhmsSensorArrayMailMaxResend | 1.3.6.1.4.1.3854.1.2.2.1.37 | INTEGER | read-write | The maximum number of times to resend mail. If set to 0 only send once. The maximum value is 25 |
| STR hhmsSensorArrayMailDestinationMac | 1.3.6.1.4.1.3854.1.2.2.1.38 | DisplayString | read-write | If the mail destination MAC address, either the smpt server or the gateway |
| STR hhmsSensorArrayMailLastStatus | 1.3.6.1.4.1.3854.1.2.2.1.39 | DisplayString | read-only | The status of the most recent attempt to send an email |
| hhmsSensorArrayPowerControlTable | 1.3.6.1.4.1.3854.1.2.2.1.40 | not-accessible | This table contains the Power Control features in the sensorArray. | |
| hhmsSensorArrayPowerControlEntry | 1.3.6.1.4.1.3854.1.2.2.1.40.1 | not-accessible | This is an entry in the hhmsSensorArrayPowerControlEntry Table | |
| STR hhmsSensorArrayPowerModuleDescription | 1.3.6.1.4.1.3854.1.2.2.1.40.1.1 | DisplayString | read-write | A Description of this Power Module |
| INT hhmsSensorArrayPowerModuleStatus | 1.3.6.1.4.1.3854.1.2.2.1.40.1.2 | INTEGER | read-only | The current status of this Sensor |
| INT hhmsSensorArrayPowerModuleOnline | 1.3.6.1.4.1.3854.1.2.2.1.40.1.3 | INTEGER | read-only | If this Sensor is currently online |
| INT hhmsSensorArrayPowerModuleGoOnline | 1.3.6.1.4.1.3854.1.2.2.1.40.1.4 | INTEGER | read-write | To put online enter a 1, to take offline enter a 2 |
| STR hhmsSensorArrayPowerOutletDescription | 1.3.6.1.4.1.3854.1.2.2.1.40.1.5 | DisplayString | read-write | A Description of this Power Port |
| INT hhmsSensorArrayPowerOutletStatus | 1.3.6.1.4.1.3854.1.2.2.1.40.1.6 | INTEGER | read-only | The current status of this Sensor |
| INT hhmsSensorArrayPowerOutletSet | 1.3.6.1.4.1.3854.1.2.2.1.40.1.7 | INTEGER | read-write | The current status of this Sensor |
| INT hhmsSensorArrayPowerControlIndex | 1.3.6.1.4.1.3854.1.2.2.1.40.1.8 | INTEGER | read-only | The index into the Power Control table |
| hhmsSensorArrayPowerMonitorTable | 1.3.6.1.4.1.3854.1.2.2.1.41 | not-accessible | This table contains the Power Monitor features in the sensorArray. | |
| hhmsSensorArrayPowerMonitorEntry | 1.3.6.1.4.1.3854.1.2.2.1.41.1 | not-accessible | This is an entry in the hhmsSensorArrayPowerMonitorEntry Table | |
| STR hhmsSensorArrayPowerMonitorDescription | 1.3.6.1.4.1.3854.1.2.2.1.41.1.1 | DisplayString | read-write | A Description of this Power Monitor |
| INT hhmsSensorArrayPowerMonitorCurrent | 1.3.6.1.4.1.3854.1.2.2.1.41.1.2 | INTEGER | read-write | The current in this sensor |
| INT hhmsSensorArrayPowerMonitorVoltage | 1.3.6.1.4.1.3854.1.2.2.1.41.1.3 | INTEGER | read-write | The voltage in this sensor |
| STR hhmsSensorArrayPowerMonitorPower | 1.3.6.1.4.1.3854.1.2.2.1.41.1.4 | DisplayString | read-write | The total energy measured so far by this sensor |
| INT hhmsSensorArrayPowerMonitorStatus | 1.3.6.1.4.1.3854.1.2.2.1.41.1.5 | INTEGER | read-only | The current status of this Sensor |
| INT hhmsSensorArrayPowerMonitorOnline | 1.3.6.1.4.1.3854.1.2.2.1.41.1.6 | INTEGER | read-only | If this Sensor is currently online |
| INT hhmsSensorArrayPowerMonitorGoOnline | 1.3.6.1.4.1.3854.1.2.2.1.41.1.7 | INTEGER | read-write | To put online enter a 1, to take offline enter a 2 |
| INT hhmsSensorArrayPowerMonitorHighWarning | 1.3.6.1.4.1.3854.1.2.2.1.41.1.8 | INTEGER | read-write | How many watts of power this sensor detects before the sensor status is set to warning |
| INT hhmsSensorArrayPowerMonitorHighCritical | 1.3.6.1.4.1.3854.1.2.2.1.41.1.9 | INTEGER | read-write | How many watts of power this sensor detects before the sensor status is set to critical |
| INT hhmsSensorArrayPowerMonitorLowWarning | 1.3.6.1.4.1.3854.1.2.2.1.41.1.10 | INTEGER | read-write | How many watts of power this sensor detects before the sensor status is set to warning |
| INT hhmsSensorArrayPowerMonitorLowCritical | 1.3.6.1.4.1.3854.1.2.2.1.41.1.11 | INTEGER | read-write | How many watts of power this sensor detects before the sensor status is set to critical |
| INT hhmsSensorArrayPowerMonitorRearm | 1.3.6.1.4.1.3854.1.2.2.1.41.1.12 | INTEGER | read-write | How many watts of power this sensor detects to rearm the status. For example if status goes from normal to warning, the temp must go down hhmsTempRearm degrees below warning before the status goes to normal |
| INT hhmsSensorArrayPowerMonitorIndex | 1.3.6.1.4.1.3854.1.2.2.1.41.1.13 | INTEGER | read-only | The index into the Power table |
| hhmsSensorArrayHighDriveTable | 1.3.6.1.4.1.3854.1.2.2.1.42 | not-accessible | This table contains the High Current Drivers in the sensorArray. | |
| hhmsSensorArrayHighDriveEntry | 1.3.6.1.4.1.3854.1.2.2.1.42.1 | not-accessible | This is an entry in the hhmsSensorArrayHighDriveEntry Table | |
| STR hhmsSensorArrayHighDriveDescription | 1.3.6.1.4.1.3854.1.2.2.1.42.1.1 | DisplayString | read-write | A Description of this Power Monitor |
| INT hhmsSensorArrayHighDriveOutputLevel | 1.3.6.1.4.1.3854.1.2.2.1.42.1.2 | INTEGER | read-write | The Driver can be on or off. If closed the Open Collector will sink current. If open the Open Collector will tri state |
| INT hhmsSensorArrayHighDriveIndex | 1.3.6.1.4.1.3854.1.2.2.1.42.1.3 | INTEGER | read-only | The index into the HighDrive table |
| hhmsSensorArrayCameraTable | 1.3.6.1.4.1.3854.1.2.2.1.43 | not-accessible | This table contains the Camera features in the sensorArray. | |
| hhmsSensorArrayCameraEntry | 1.3.6.1.4.1.3854.1.2.2.1.43.1 | not-accessible | This is an entry in the hhmsSensorArrayCameraEntry Table | |
| STR hhmsSensorArrayCameraDescription | 1.3.6.1.4.1.3854.1.2.2.1.43.1.1 | DisplayString | read-write | A Description of this Camera |
| INT hhmsSensorArrayCameraOnline | 1.3.6.1.4.1.3854.1.2.2.1.43.1.2 | INTEGER | read-only | If this Sensor is currently online |
| INT hhmsSensorArrayCameraGoOnline | 1.3.6.1.4.1.3854.1.2.2.1.43.1.3 | INTEGER | read-write | To put online enter a 1, to take offline enter a 2 |
| STR hhmsSensorArrayCameraUrlMain | 1.3.6.1.4.1.3854.1.2.2.1.43.1.4 | DisplayString | read-write | The URL of the Camera, for example http://10.1.1.7 |
| STR hhmsSensorArrayCameraUrlExtension | 1.3.6.1.4.1.3854.1.2.2.1.43.1.5 | DisplayString | read-write | The cgi extension for the Picture from this Camera for example /webcam/server.jpg |
| INT hhmsSensorArrayCameraRefreshRate | 1.3.6.1.4.1.3854.1.2.2.1.43.1.6 | INTEGER | read-write | How often to refresh the image on the browser in seconds from 5 to 254 |
| INT hhmsSensorArrayCameraIndex | 1.3.6.1.4.1.3854.1.2.2.1.43.1.7 | INTEGER | read-only | The index into the Camera table |
| INT hhmsSensorArrayTrapMailPollInterval | 1.3.6.1.4.1.3854.1.2.2.1.50 | INTEGER | read-write | How often the sensor thresholds are tested before sending traps or mail. This can vary from 3 to 15 seconds |
| INT hhmsSensorArraySendTestMail | 1.3.6.1.4.1.3854.1.2.2.1.51 | INTEGER | read-write | Send out an email test message |
| STR hhmsSensorArrayLastSystemError | 1.3.6.1.4.1.3854.1.2.2.1.52 | DisplayString | read-only | A text string containing the description of the last system error |
| INT hhmsSensorArrayDataCollectionPeriod | 1.3.6.1.4.1.3854.1.2.2.1.53 | INTEGER | read-write | The number of minutes between collections of the data logger. This can vary from 1 to 60 minutes |
| INT hhmsSensorArrayMailTimeout | 1.3.6.1.4.1.3854.1.2.2.1.54 | INTEGER | read-write | The number of seconds to wait for a timeout while sending email This can vary from 10 to 60 seconds |
| hhmsAgentConfig | 1.3.6.1.4.1.3854.1.5 | |||
| STR hhmsAgentVersion | 1.3.6.1.4.1.3854.1.5.1 | DisplayString | read-only | The hhms agent release version number |
| hhmsCompressedSummaryTable | 1.3.6.1.4.1.3854.1.5.7 | not-accessible | This table contains a way to get summary info to the browser using minimum communication. One get contains a PDU info from multiple sensorArrays | |
| hhmsCompressedSummaryEntry | 1.3.6.1.4.1.3854.1.5.7.1 | not-accessible | This is an entry in the hhmsCompressedSummary Table | |
| STR hhmsCompressedSummaryGet | 1.3.6.1.4.1.3854.1.5.7.1.1 | DisplayString | read-only | Get multiple compressed summary PDU |
| INT hhmsCompressedSummaryIndex | 1.3.6.1.4.1.3854.1.5.7.1.2 | INTEGER | read-only | The index into the compressed summary table |
| hhmsAgentTraps | 1.3.6.1.4.1.3854.1.7 | |||
| INT hhmsSensorStatus | 1.3.6.1.4.1.3854.1.7.1 | INTEGER | read-only | The current integer status of the sensor causing this trap to be sent |
| INT hhmsSensorValue | 1.3.6.1.4.1.3854.1.7.2 | INTEGER | read-only | The current integer value of the sensor causing this trap to be sent |
| INT hhmsSensorLevelExceeded | 1.3.6.1.4.1.3854.1.7.3 | INTEGER | read-only | The integer level that was exceeded causing this trap to be sent |
| INT hhmsSensorIndex | 1.3.6.1.4.1.3854.1.7.4 | INTEGER | read-only | The integer index of the sensor causing this trap to be sent |
| STR hhmsSensorName | 1.3.6.1.4.1.3854.1.7.5 | DisplayString | read-only | The name of the sensor causing this trap to be sent |
| STR hhmsSensorDescription | 1.3.6.1.4.1.3854.1.7.6 | DisplayString | read-only | The description of the sensor causing this trap to be sent |
RFC description
Monitors environmental sensors (temperature, humidity) status and alarms on AKCP Intelligent Rack PDU devices.
Start monitoring AKCP environmental monitoring unit (SNMP agent location) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.