DKSF-201-9-X-X-1

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsDKSF-201-9-X-X-1

Organization: Alentis Electronics

Last Updated: 2015-08-17

Category: Domain: Environmental Monitoring, Vendor: NetPing/DKSF

Description: MIB for DKSF-201 NetPing device firmware 9.x providing remote environmental sensor and relay management objects.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is DKSF-201-9-X-X-1?

DKSF-201-9-X-X-1 is the vendor MIB for the NetPing DKSF-201 device (firmware 9.x), part of NetPing's line of network-attached remote sensing and control units used for environmental and power monitoring. It exposes objects for controllable relay outputs and power channel status, along with trap/notification configuration for alerting. As a remote monitoring appliance MIB, it is centrally about hardware status: relay state (on/off), power channel presence, and device event notifications, rather than traditional CPU/memory metrics, since the device itself is a small embedded sensor/controller rather than a general-purpose computer. It is a self-contained proprietary MIB with no apparent dependency on other standard MIBs beyond basic SNMP notification infrastructure. It is typically deployed in server rooms, telecom cabinets, or remote sites to remotely power-cycle equipment and receive alerts via SNMP traps or email. Engineers can download the DKSF-201-9-X-X-1 file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in DKSF-201-9-X-X-1. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • NetPing DKSF-201 remote sensing and relay control unit

Monitoring Examples

An administrator would poll the npRelayTable (npRelayEntry, indexed by npRelayN) to read npRelayState and npRelayMode, confirming whether a given relay channel is currently switched on or off, and could invoke npRelayFlip or npRelayStartReset to toggle or reset a relay remotely. The npPwrTable (npPwrEntry, npPwrChannelN) provides per-channel power status, useful for detecting a lost power feed to attached equipment. npTrapEmailTo and npTrapInfo show how the device is configured to send email or trap notifications when relay or power events occur, and npRelayMemo provides a human-readable label for each relay's purpose.

What Can Be Monitored

  • relay on/off state per channel
  • power channel status
  • relay reset/flip actions
  • trap and email notification configuration
  • relay channel labels/memo
Imported Objects

From SNMPv2-MIB

snmpTrapsOBJECT-IDENTITY

From SNMPv2-SMI

Counter32
Counter64
Gauge32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
TimeTicks
enterprises

From SNMPv2-TC

DisplayString
TEXTUAL-CONVENTION
TimeStamp
TruthValue

How to Use in IPNetwork Monitor

Example using npIoPulseCounter OID:

Select a NetPing DKSF-201 remote sensing and relay control unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type npIoPulseCounter into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the pulse Counter on IO input line (counts positive fronts) Write 0 to reset. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Generic MIB for NetPing remote environmental sensing and relay control devices. Manages sensors, output controls, and notification thresholds.

Start monitoring NetPing DKSF-201 remote sensing and relay control unit with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download DKSF-201-9-X-X-1