HH3C-LOGIC-VOLUME-MIB :: hh3cTISessionConnectionCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HH3C-LOGIC-VOLUME-MIB › hh3cTISessionConnectionCount

hh3cTISessionConnectionCount

Module: HH3C-LOGIC-VOLUME-MIB

OID (symbolic): HH3C-LOGIC-VOLUME-MIB::hh3cTISessionConnectionCount

OID (numeric): 1.3.6.1.4.1.25506.10.5.1.9.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This object describes the number of connections between the targets and initiators.

What is hh3cTISessionConnectionCount?

Counts the number of active connections within an iSCSI session between a target and initiator, which an admin can check to confirm multi-connection sessions (MC/S) are established as expected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.10.5.1.9.1.2
snmpwalk -v2c -c public <target> HH3C-LOGIC-VOLUME-MIB::hh3cTISessionConnectionCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.10.5.1.9.1.2.1
snmpget -v2c -c public <target> HH3C-LOGIC-VOLUME-MIB::hh3cTISessionConnectionCount.1

Start monitoring H3C storage array/converged storage platform (logical volume management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-LOGIC-VOLUME-MIB::hh3cTISessionConnectionCount OID value, configure state conditions and alerts, and monitor any H3C storage array/converged storage platform (logical volume management) from a single console.

How to Use in IPNetwork Monitor

Select an H3C storage array/converged storage platform (logical volume management) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hh3cTISessionConnectionCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object describes the number of connections between the targets and initiators. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.10hh3cStorageRefHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.10.5hh3cLogicVolumeHH3C-LOGIC-VOLUME-MIB
1.3.6.1.4.1.25506.10.5.1hh3cLvMibObjectsHH3C-LOGIC-VOLUME-MIB
1.3.6.1.4.1.25506.10.5.1.9hh3cTISessionTableHH3C-LOGIC-VOLUME-MIB
1.3.6.1.4.1.25506.10.5.1.9.1hh3cTISessionEntryHH3C-LOGIC-VOLUME-MIB
1.3.6.1.4.1.25506.10.5.1.9.1.2hh3cTISessionConnectionCountHH3C-LOGIC-VOLUME-MIB