All MIBs › HH3C-E1-MIB
Organization: Hangzhou H3C Technologies Co., Ltd.
Last Updated: 2012-07-16
Category: Domain: WAN, Vendor: H3C/HH3C
Description: Manages E1 (2 Mbps) WAN interface configuration and performance monitoring on H3C router interface cards.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HH3C-E1-MIB?
HH3C-E1-MIB is an H3C enterprise MIB providing E1 (2.048 Mbps) WAN interface objects not covered by the standard RFC 1213/RFC 2233 interface MIBs, used to manage E1 trunk interfaces on H3C routers and WAN interface cards. It exposes a per-interface status table with detailed line-quality error counters covering CRC errors, alignment errors, framing errors, over-run/under-run (giants/runts) errors, and dribble/aborted-sequence errors. This is a hardware performance and fault-monitoring MIB: tracking these error counters over time reveals a degrading physical E1 line, cabling or clocking issues, or a failing interface card, complementing the interface's basic up/down status. It explicitly supplements standard IETF interface MIBs (RFC 1213, RFC 2233) rather than replacing them. Typical deployment is on H3C routers with E1 WAN interface modules used for leased-line or PDH transport connections, and administrators typically perform an HH3C-E1-MIB download to load the module definitions into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in HH3C-E1-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- H3C router with E1 WAN interface card
Monitoring Examples
An operator would poll hh3ce1InterfaceStatusTable (per hh3ce1InterfaceStatusEntry) and watch hh3ce1InterfaceInCrcErrs and hh3ce1InterfaceInAlignErrs for a rising trend, indicating physical line degradation on the E1 circuit. A jump in hh3ce1InterfaceInFramingErrs or hh3ce1InterfaceInOverRunsErrs would point to clocking mismatch or a card-level buffering problem on that E1 port.
What Can Be Monitored
- E1 interface CRC errors
- alignment errors
- framing errors
- over-run/under-run errors
- runts/giants errors
- aborted sequence errors
Imported Objects
From HH3C-OID-MIB
| hh3cCommon | OBJECT-IDENTITY |
From RFC1213-MIB
| ifIndex |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| RowStatus | |
| TEXTUAL-CONVENTION |
How to Use in IPNetwork Monitor
Example using hh3ce1InterfaceInErrs OID:
OIDs
RFC description
HH3C vendor-private MIB for E1 digital interface management and configuration on HH3C network devices.
Start monitoring H3C router with E1 WAN interface card with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.