HH3C-E1-MIB :: hh3ce1InterfaceInErrs

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HH3C-E1-MIB › hh3ce1InterfaceInErrs

hh3ce1InterfaceInErrs

Module: HH3C-E1-MIB

OID (symbolic): HH3C-E1-MIB::hh3ce1InterfaceInErrs

OID (numeric): 1.3.6.1.4.1.25506.2.28.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of error received on this interface

What is hh3ce1InterfaceInErrs?

Counts the total number of receive errors seen on this E1 interface, combining all the more specific inbound error counters in this table. Admins check this first as a general health indicator before drilling into runts, CRC, or alignment errors to find the root cause.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.28.1.1.1
snmpwalk -v2c -c public <target> HH3C-E1-MIB::hh3ce1InterfaceInErrs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.28.1.1.1.1
snmpget -v2c -c public <target> HH3C-E1-MIB::hh3ce1InterfaceInErrs.1

Start monitoring H3C router with E1 WAN interface card with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-E1-MIB::hh3ce1InterfaceInErrs OID value, configure state conditions and alerts, and monitor any H3C router with E1 WAN interface card from a single console.

How to Use in IPNetwork Monitor

Select an H3C router with E1 WAN interface card as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hh3ce1InterfaceInErrs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of error received on this interface. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.2hh3cCommonHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.2.28hh3cE1HH3C-E1-MIB
1.3.6.1.4.1.25506.2.28.1hh3ce1InterfaceStatusTableHH3C-E1-MIB
1.3.6.1.4.1.25506.2.28.1.1hh3ce1InterfaceStatusEntryHH3C-E1-MIB
1.3.6.1.4.1.25506.2.28.1.1.1hh3ce1InterfaceInErrsHH3C-E1-MIB