| OID symbolic | OID numeric | Type | Access | Description |
| gswitch | 1.3.6.1.4.1.629.2 | | | |
| nbase | 1.3.6.1.4.1.629 | | | |
| nbsAddressTable | 1.3.6.1.4.1.629.2.8 | | | |
| INT nbsAddrForwardTo | 1.3.6.1.4.1.629.2.8.1.1.6 | INTEGER | read-write | This indicates whether to forward frames destined
to this MAC address to all ports or only to the
destination port |
| INT nbsAddrIndex | 1.3.6.1.4.1.629.2.8.1.1.1 | INTEGER | read-only | An index from 1 to 8K. * (number of devices+1) |
| INT nbsAddrPort | 1.3.6.1.4.1.629.2.8.1.1.4 | INTEGER | read-write | The source port in this device |
| INT nbsAddrStatic | 1.3.6.1.4.1.629.2.8.1.1.5 | INTEGER | read-write | Static indecation bit in the MAC Address entry |
| INT nbsBackOffMode | 1.3.6.1.4.1.629.2.3.16 | INTEGER | read-write | The CSMA/CD normal Back of mode multiples the back-off
time frame after each each collision. In aggressive mode
it stops to multiply after the second time. This way it
will have an advantage of any other NIC who uses normal
back-off mode. |
| INT nbsBaseHardVers | 1.3.6.1.4.1.629.2.2.3 | INTEGER | read-only | Hardware version of base card |
| INT nbsBufferThreshold | 1.3.6.1.4.1.629.2.3.10 | INTEGER | read-write | Buffer Threshold Enable.
Meaningful only when RMONEn bit (internal) is set.
1 - The buffers allocated to the ports
are limited to the number which is written in the
Rx Buffers Threshold Register.
2 - There is no limitation on the buffers allocation |
| INT nbsCardHardVers | 1.3.6.1.4.1.629.2.2.4 | INTEGER | read-only | Hardware version of the agent card |
| INT nbsCardIndex | 1.3.6.1.4.1.629.2.9.1.1.1 | INTEGER | read-only | The slot#. An index from 1 to The number of slots. |
| nbsCardsEntry | 1.3.6.1.4.1.629.2.9.1.1 | | not-accessible | The entries (records) |
| nbsCardsTable | 1.3.6.1.4.1.629.2.9.1 | | not-accessible | define the Cards' Types
(for NH5500 and other GSWITCH HUBS..). |
| INT nbsCardType | 1.3.6.1.4.1.629.2.9.1.1.2 | INTEGER | read-only | The Card's type:
copper20Ethernet10or100Base (2) - Slot including 20 fast copper 10/100 MBps Ports;
copper40Ethernet10Base (3) - Slot including 40 normal copper 10 MBps Ports;
fibre10Ethernet100Base (6) - Slot including 10 fast fibre optic 100 MBps Ports;
universal (9) - Slot including Uplink Modules of the different types; |
| STR nbsCreatinDate | 1.3.6.1.4.1.629.2.2.10 | DisplayString | read-only | Agent software creation date and time |
| nbsDeviceControl | 1.3.6.1.4.1.629.2.3 | | | |
| nbsDevIdentify | 1.3.6.1.4.1.629.2.2 | | | |
| INT nbsForwardMulticast | 1.3.6.1.4.1.629.2.3.12 | INTEGER | read-write | Forward Multicast.
Enable - multicast packets are Forwarded only to the CPU.
Disable - multicast packets are being forward to all ports |
| INT nbsForwardUnkPkts | 1.3.6.1.4.1.629.2.3.15 | INTEGER | read-write | Forward Unknown Packets.
If defines whether the Switch-G will forward Unknown
packets to the Agent CPU or not.
1 - Forwared,
2 - Do not forwared |
| INT nbsLearningProcess | 1.3.6.1.4.1.629.2.3.7 | INTEGER | read-write | Disable Learning Process.
1 - Learning Process is disabled. The Switch-G will not learn
any new addresses from the wire.
2 - Learning Process is enabled |
| INT nbsLinkTest | 1.3.6.1.4.1.629.2.6.1.1.4 | INTEGER | read-only | Ports Link Test Fail.
Indicates the ports Link Test status
1 - Link Test Pass
2 - Link Test Fail |
| nbsMACAddrEntry | 1.3.6.1.4.1.629.2.8.1.1 | | not-accessible | The entries (records) |
| OCT nbsMACAddress | 1.3.6.1.4.1.629.2.8.1.1.3 | OCTET STRING | read-write | The MAC Address where the packet came from |
| nbsMACAddrTable | 1.3.6.1.4.1.629.2.8.1 | | not-accessible | The DRAM address table contains all the MAC addresses
up to 8K records. |
| INT nbsMacFirstGap | 1.3.6.1.4.1.629.2.11 | INTEGER | read-only | The index of the first gap (empty record) in the MAC table |
| INT nbsNMacRecords | 1.3.6.1.4.1.629.2.10 | INTEGER | read-only | The number of Records (addresses) in the MAC table |
| INT nbsNPorts | 1.3.6.1.4.1.629.2.1 | INTEGER | read-only | The number of ports in this device |
| INT nbsPALPortIndex | 1.3.6.1.4.1.629.2.12.1.1.1 | INTEGER | read-only | The number of the real existing PAL port.
(the same as [ifIndex] in the MIB-II). |
| INT nbsPALPortOpticPower | 1.3.6.1.4.1.629.2.12.1.1.2 | INTEGER | read-only | PAL Port Optic Power status.
(interval: 0 - 15) |
| nbsPALPorts | 1.3.6.1.4.1.629.2.12 | | | |
| nbsPALPortsEntry | 1.3.6.1.4.1.629.2.12.1.1 | | not-accessible | The PAL Optic Power Ports status. |
| nbsPALPortsTable | 1.3.6.1.4.1.629.2.12.1 | | not-accessible | Table contain data only for
the existing PAL modules ports. |
| INT nbsParitionEnable | 1.3.6.1.4.1.629.2.3.8 | INTEGER | read-write | Partition Mode Enable.
When more then 32 collisions occur while transmitting, the
Switch-G port enters to the Partition mode. It waits for the first
good packet from the wire and then return to Normal mode of opration.
In Partition mode transmitting fromthe port is enabled but receiving is disabled.
1 - Patrition mode,
2 - Normal mode |
| INT nbsPartition | 1.3.6.1.4.1.629.2.6.1.1.3 | INTEGER | read-only | Ports Partition.
Indicates the ports Partition status.
1 - No Partition (Normal mode)
2 - Partition |
| CTR nbsPortBadByteRec | 1.3.6.1.4.1.629.2.7.1.1.16 | Counter | read-only | Bad Bytes Recived.
Bytes with CRC errors and frame too long |
| CTR nbsPortBroadByteRec | 1.3.6.1.4.1.629.2.7.1.1.4 | Counter | read-only | Good Broadcast Bytes Recived |
| INT nbsPortBroadcast | 1.3.6.1.4.1.629.2.5.1.1.7 | INTEGER | read-write | Filter Broadcast.
1 - Broadcast packats are forwarded to all ports.
2 - The Switch-G discards Broadcast packats |
| CTR nbsPortBroadFramesRec | 1.3.6.1.4.1.629.2.7.1.1.8 | Counter | read-only | Broadcast Frames Recived |
| CTR nbsPortByteRec | 1.3.6.1.4.1.629.2.7.1.1.2 | Counter | read-only | Good Bytes Recived |
| CTR nbsPortByteSent | 1.3.6.1.4.1.629.2.7.1.1.5 | Counter | read-only | Good Bytes Sent |
| CTR nbsPortCollisions | 1.3.6.1.4.1.629.2.7.1.1.10 | Counter | read-only | Recive and Transmit Collision |
| CTR nbsPortCRCAligErr | 1.3.6.1.4.1.629.2.7.1.1.12 | Counter | read-only | Recive CRC or Alignment Error |
| INT nbsPortDuplex | 1.3.6.1.4.1.629.2.5.1.1.3 | INTEGER | read-write | Half/Full Duplex.
1 - Port works in Half-Duplex mode
2 - Port works in Full-Duplex mode |
| INT nbsPortEnable | 1.3.6.1.4.1.629.2.5.1.1.2 | INTEGER | read-write | Port Enable.
1 - Port is enabled
2 - Port is disabled |
| INT nbsPortForwardUnk | 1.3.6.1.4.1.629.2.5.1.1.8 | INTEGER | read-write | Forward Unknown.
1 - Unknown packats are forwarded.
2 - The Switch-G does not forward unknown packats
to this port |
| CTR nbsPortFrameLong | 1.3.6.1.4.1.629.2.7.1.1.14 | Counter | read-only | Recive Frames > 1518 bytes with Good CRC |
| CTR nbsPortFramesRec | 1.3.6.1.4.1.629.2.7.1.1.6 | Counter | read-only | Good Frames Recived |
| CTR nbsPortFramesSent | 1.3.6.1.4.1.629.2.7.1.1.9 | Counter | read-only | Frames Sent |
| CTR nbsPortFramesShort | 1.3.6.1.4.1.629.2.7.1.1.13 | Counter | read-only | Recive Frames |
| INT nbsPortIndex | 1.3.6.1.4.1.629.2.6.1.1.1 | INTEGER | read-only | The port# from 1 to nbsNPorts1 |
| INT nbsPortIndex1 | 1.3.6.1.4.1.629.2.5.1.1.1 | INTEGER | read-only | The port# from 1 to nbsNPorts1 |
| INT nbsPortIndex2 | 1.3.6.1.4.1.629.2.7.1.1.1 | INTEGER | read-only | The port# from 1 to nbsNPorts1 |
| CTR nbsPortJabber | 1.3.6.1.4.1.629.2.7.1.1.15 | Counter | read-only | Recive Frames > 1518 bytes with Bad CRC |
| CTR nbsPortLateColl | 1.3.6.1.4.1.629.2.7.1.1.11 | Counter | read-only | Recive and Transmit Late Collision |
| INT nbsPortMonitor | 1.3.6.1.4.1.629.2.5.1.1.5 | INTEGER | read-write | Monitoring Mode.
1 - Port works in normal mode
2 - Port is set as Sniffer port (monitor mode) were all recived
and transmit packats from all ports are sent to the Sniffer port |
| CTR nbsPortMulByteRec | 1.3.6.1.4.1.629.2.7.1.1.3 | Counter | read-only | Good Multicast Bytes Recived |
| CTR nbsPortMulFramesRec | 1.3.6.1.4.1.629.2.7.1.1.7 | Counter | read-only | Good Multicast Frames Recived |
| INT nbsPortPolDetection | 1.3.6.1.4.1.629.2.5.1.1.6 | INTEGER | read-write | Auto-Polarity Disable.
Enable/Disable Auto-Polarity detection function
1 - Disable
2 - Enable |
| nbsPortsContEntry | 1.3.6.1.4.1.629.2.5.1.1 | | not-accessible | Contains the information necessary to configure/describe a
port configuration. The number of rows/entries is fixed. A
row/entry may not be created or deleted |
| nbsPortsControl | 1.3.6.1.4.1.629.2.5 | | | |
| nbsPortsContTable | 1.3.6.1.4.1.629.2.5.1 | | not-accessible | A list of the port counters entries |
| nbsPortsCountEntry | 1.3.6.1.4.1.629.2.7.1.1 | | not-accessible | Contains the information necessary to configure/describe a
port configuration. The number of rows/entries is fixed. A
row/entry may not be created or deleted |
| nbsPortsCounters | 1.3.6.1.4.1.629.2.7 | | | |
| nbsPortsCountTable | 1.3.6.1.4.1.629.2.7.1 | | not-accessible | A list of the port counters entries |
| INT nbsPortSpaning | 1.3.6.1.4.1.629.2.5.1.1.9 | INTEGER | read-write | Spaning Tree Enable.
Meaniningful only when Spaning Tree for the switch is set
(nbsSpanningTree) is set.
1 - All packets are accepted.
2 - The Switch-G discards all incoming/outgoing packets
except for BPDU packets |
| INT nbsPortSpeed | 1.3.6.1.4.1.629.2.5.1.1.10 | INTEGER | read-write | Ports Speed.
Meaningfull only for ports that support both 10 and 100
MBps speeds.
1 - Only for Uplink Ports: Switch-G - Ports ## 27,28
Switch-G - Ports ## 17,18
2 - After reset the port will operate in 10 MBps
3 - After reset the port will operate in 100 Mbps
4 - The port will operate in 1000 Mbps
5 - The port will operate in 10000 MBps (for example, XFP). |
| nbsPortsStatEntry | 1.3.6.1.4.1.629.2.6.1.1 | | not-accessible | The ports status information.
port configuration. The number of rows/entries is fixed. A
row/entry may not be created or deleted |
| nbsPortsStatTable | 1.3.6.1.4.1.629.2.6.1 | | not-accessible | A list of all the port status objects |
| nbsPortsStatus | 1.3.6.1.4.1.629.2.6 | | | |
| INT nbsPortType | 1.3.6.1.4.1.629.2.6.1.1.2 | INTEGER | read-only | Port Type |
| INT nbsRMONmode | 1.3.6.1.4.1.629.2.3.9 | INTEGER | read-write | RMON Enable.
1 - The Switch-G enters the RMON mode(Station-to-Station
connectivity Matrix).
2 - RMON disabled |
| nbsSlotsTable | 1.3.6.1.4.1.629.2.9 | | | |
| INT nbsSnifferPort | 1.3.6.1.4.1.629.2.2.9 | INTEGER | read-only | Sniffer Port Number.
Specify the Sniffer Port Number chosen by
the user |
| INT nbsSoftVers | 1.3.6.1.4.1.629.2.2.6 | INTEGER | read-only | Agent software version |
| INT nbsSpanningTree | 1.3.6.1.4.1.629.2.3.6 | INTEGER | read-write | Spanning Tree Enable.
1 - The BPDU(Bridge Protocol Data Unit) packets are treated
as Multicast Packets, and therefore are forwarded to
all ports.
2 - Forwards BPDU(Bridge Protocol Data Unit) packets to the CPU only. |
| INT nbsUpLinkHardVers | 1.3.6.1.4.1.629.2.2.5 | INTEGER | read-only | Up-Link hardware version |
| INT nbsUpLinkType | 1.3.6.1.4.1.629.2.2.1 | INTEGER | read-only | Up-Link Type of the device |