All MIBs › GSC-OPT-MIB
Category: Optical and WDM
Description: GSC optical MIB for managing optical network equipment configuration and transceiver performance monitoring.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is GSC-OPT-MIB?
GSC-OPT-MIB, despite its filename, is a Codex/Motorola enterprise MIB (codex(449).cdxProductSpecific.cdx6500) for the Codex 6500 statistical multiplexer's GSC (poll-based station-controller) ports rather than an optical-transceiver MIB. Its cdx6500PPCTGSCPortTable, indexed by cdx6500GSCPCfgPortNumber, configures each GSC port's role and protocol timing: cdx6500GSCPCfgSubtype distinguishes a port acting as a terminal PAD (gscTpad) from one acting as a host PAD (gscHpad), cdx6500GSCPCfgClockSpeed and cdx6500GSCPCfgNumStations set line speed and attached-station count, and a large set of timers — cdx6500GSCPCfgMinPollPeriod, cdx6500GSCPCfgPollRespTimer, cdx6500GSCPCfgAckTimeOut, cdx6500GSCPCfgInterCharTimeOut, cdx6500GSCPCfgBroadcastHoldTimeOut, cdx6500GSCPCfgSolicitedTimeOut, cdx6500GSCPCfgIdleDiscTimeOut, and cdx6500GSCPCfgAutocallRetryTimeOut — tune the polling protocol between the multiplexer and its attached terminals. This is fundamentally a serial polling-protocol configuration MIB: monitoring it reveals how a GSC port is provisioned and how aggressively it polls attached devices, which matters when diagnosing dropped or slow-to-respond terminal sessions. It depends only on RFC1155-SMI and RFC-1212 base types, consistent with its early-1990s SNMPv1 origin. Engineers supporting legacy Codex 6500 multiplexers can locate a GSC-OPT-MIB download to inspect and tune these per-port polling parameters.
IPNetwork Monitor allows you to monitor SNMP objects defined in GSC-OPT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Codex (Motorola) 6500 statistical multiplexer, GSC port module
Monitoring Examples
An operator polls cdx6500GSCPCfgNumStations and cdx6500GSCPCfgPollRespTimer for a GSC port to confirm the configured station count matches the physically attached terminals and that the poll-response timeout is appropriate for the line speed; terminals repeatedly timing out despite a generous cdx6500GSCPCfgAckTimeOut would point to a wiring or terminal-configuration problem on that port.
What Can Be Monitored
- GSC port subtype (terminal vs. host PAD)
- configured clock speed and station count
- poll period and poll-response timers
- acknowledgment and inter-character timeouts
- broadcast-hold and idle-disconnect timers
- autocall retry configuration
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| Counter | |
| enterprises |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| codex | 1.3.6.1.4.1.449 | |||
| cdxProductSpecific | 1.3.6.1.4.1.449.2 | |||
| cdx6500 | 1.3.6.1.4.1.449.2.1 | |||
| cdx6500Configuration | 1.3.6.1.4.1.449.2.1.2 | |||
| cdx6500CfgProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1 | |||
| cdx6500PCTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1.1 | |||
| cdx6500PPCTGSCPortTable | 1.3.6.1.4.1.449.2.1.2.1.1.29 | not-accessible | This table contains GSC port configuration parameters. | |
| cdx6500PPCTGSCPortEntry | 1.3.6.1.4.1.449.2.1.2.1.1.29.1 | not-accessible | Configuration parameters relevant to a GSC port. | |
| INT cdx6500GSCPCfgPortNumber | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.1 | INTEGER | read-only | Port number of the port being used by GSC |
| INT cdx6500GSCPCfgPortType | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.2 | INTEGER | read-only | The Port Type of the port. |
| INT cdx6500GSCPCfgSubtype | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.3 | INTEGER | read-only | The GSC port sub-type. gscHpad - Port is functioning as a host PAD. gscTpad - Port is functioning as a terminal PAD. |
| INT cdx6500GSCPCfgClockSpeed | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.4 | INTEGER | read-only | This is the clock speed of the port in bits per second, when internal clocking is used. |
| INT cdx6500GSCPCfgNumStations | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.5 | INTEGER | read-only | The number of stations/devices configured on this port. |
| INT cdx6500GSCPCfgMinPollPeriod | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.6 | INTEGER | read-only | The minimum time the TPAD waits between polls. Specified in 50 ms increments (i.e. 1 means 50 ms). |
| INT cdx6500GSCPCfgPollRespTimer | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.7 | INTEGER | read-only | The maximum time the TPAD waits for a response from the terminal after a poll. Specified in 50 ms increments (i.e. 5 means 250 ms). |
| INT cdx6500GSCPCfgAckTimeOut | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.8 | INTEGER | read-only | The maximum time the TPAD or HPAD waits for acknowledgement for a transmitted frame. Specified in 50 ms increments (i.e. 5 means 250 ms). |
| INT cdx6500GSCPCfgInterCharTimeOut | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.9 | INTEGER | read-only | The maximum time period allowed between received characters. Specified in 50 ms increments (i.e. 5 means 250 ms). |
| INT cdx6500GSCPCfgBroadcastHoldTimeOut | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.10 | INTEGER | read-only | The time the TPAD holds a broadcast frame from one station, when it detects a dropped frame, while waiting for the missing frame from another station. Specified in 50 ms increments (i.e. 5 means 250 ms). |
| INT cdx6500GSCPCfgSolicitedTimeOut | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.11 | INTEGER | read-only | Specifies the time that the TPAD waits for a SAD message in response to a PAD message, before re-transmitting the PAD message. Specified in 50 ms increments (i.e. 60 means 3 seconds). |
| INT cdx6500GSCPCfgIdleDiscTimeOut | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.12 | INTEGER | read-only | The period that the HPAD waits to receive a UAD-frame, SAD-frame or poll from the polling controller before clearing the call to the TPAD. Specified in minutes (i.e. 5 means 5 minutes). |
| INT cdx6500GSCPCfgAutocallRetryTimeOut | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.13 | INTEGER | read-only | Specifies the time to wait between subsequent autocall attempts. Specified in 50 ms increments. (i.e. 4 means 200 ms). |
| INT cdx6500GSCPCfgMaxAutocallRetries | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.14 | INTEGER | read-only | The maximum number of autocall attempts allowed. The port is disabled when the limit is reached. |
| INT cdx6500GSCPCfgN1 | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.15 | INTEGER | read-only | The number of good responses a TPAD must receive before changing a stations state from UP to DOWN . |
| INT cdx6500GSCPCfgN2 | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.16 | INTEGER | read-only | The number of good responses a TPAD must receive before changing a stations state from DOWN to UP. |
| INT cdx6500GSCPCfgNumRetries | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.17 | INTEGER | read-only | The number of times the TPAD or HPAD will retry a selection procedure before discarding a frame. |
| STR cdx6500GSCPCfgPortAddress | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.18 | DisplayString | read-only | When a GSC port makes a call,this address is inserted into the calling address field. |
| STR cdx6500GSCPCfgPortOptions | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.19 | DisplayString | read-only | The port options specified : NONE - No option specified. |
| INT cdx6500GSCPCfgConnType | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.20 | INTEGER | read-only | Specifies the control signal handshake and clocking required for a connection to be made to this port. simp - simple, no control signals required. simpa - CTS follows RTS, but no control signals required. nc - Skipped during configuration. |
| INT cdx6500GSCPCfgWakeUpTimer | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.21 | INTEGER | read-only | Specifies the time to wait after autocall attempts are exhausted before attempting another autocall cycle. A value of 0 will prevent subsequent attempts until the station is booted. |
| INT cdx6500GSCPCfgElectricalInterfaceType | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.22 | INTEGER | read-only | Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled |
| INT cdx6500GSCPCfgV24ElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.23 | INTEGER | read-only | Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal |
| INT cdx6500GSCPCfgHighSpeedElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.29.1.24 | INTEGER | read-only | Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| cdx6500PCTStationProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1.3 | |||
| cdx6500SPCTGSCStationTable | 1.3.6.1.4.1.449.2.1.2.1.3.8 | not-accessible | This table contains GSC station configuration parameters. | |
| cdx6500SPCTGSCStationEntry | 1.3.6.1.4.1.449.2.1.2.1.3.8.1 | not-accessible | Each StationEntry contains the configuration parameters for one GSC station. | |
| INT cdx6500GSCSCfgPortNumber | 1.3.6.1.4.1.449.2.1.2.1.3.8.1.1 | INTEGER | read-only | Port number of the port being used by GSC. |
| INT cdx6500GSCSCfgStationNumber | 1.3.6.1.4.1.449.2.1.2.1.3.8.1.2 | INTEGER | read-only | The number of devices on the multidrop line. Also used for routing purposes. |
| INT cdx6500GSCSCfgStationAddress | 1.3.6.1.4.1.449.2.1.2.1.3.8.1.3 | INTEGER | read-only | The device address on the local line. |
| INT cdx6500GSCSCfgRemoteAddress | 1.3.6.1.4.1.449.2.1.2.1.3.8.1.4 | INTEGER | read-only | The device address on the remote line. |
| STR cdx6500GSCSCfgAutocallMnem | 1.3.6.1.4.1.449.2.1.2.1.3.8.1.5 | DisplayString | read-only | Identifies the entry in the Autocall Mnemonic table which specifies the X.25 call request parameters for this station.This is valid only if the port subtype is HPAD. |
| STR cdx6500GSCSCfgProtocolId | 1.3.6.1.4.1.449.2.1.2.1.3.8.1.6 | DisplayString | read-only | The protocol ID inserted in outgoing calls and checked for incoming calls. |
| INT cdx6500GSCSCfgBillingRecords | 1.3.6.1.4.1.449.2.1.2.1.3.8.1.7 | INTEGER | read-only | billingOff - Billing records are not generated. billingOn - Billing records are generated. |
| STR cdx6500GSCSCfgStationOptions | 1.3.6.1.4.1.449.2.1.2.1.3.8.1.8 | DisplayString | read-only | GSC station options: NONE - no option specified IBRO - Inband Broadcast frames supported on this channel. One or more options may be specified by summing (separating them by a plus sign). |
| cdx6500Statistics | 1.3.6.1.4.1.449.2.1.3 | |||
| cdx6500StatProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1 | |||
| cdx6500PSTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1.1 | |||
| cdx6500PPSTGSCPortTable | 1.3.6.1.4.1.449.2.1.3.1.1.30 | not-accessible | This table holds statistics items for GSC ports. | |
| cdx6500PPSTGSCPortEntry | 1.3.6.1.4.1.449.2.1.3.1.1.30.1 | not-accessible | Statistics parameters pertaining to GSC Ports. | |
| INT cdx6500GSCPStatPortNumber | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.1 | INTEGER | read-only | The port number of the GSC port. |
| INT cdx6500GSCPStatPortType | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.2 | INTEGER | read-only | The port type. |
| INT cdx6500GSCPStatSubtype | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.3 | INTEGER | read-only | The port sub-type. gscHpad - port is functioning as a host PAD. gscTpad - Port is functioning as a terminal PAD. |
| INT cdx6500GSCPStatPortStatus | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.4 | INTEGER | read-only | Status of the port: disabled - Port is disabled. enabled - Port is enabled. busyOut - The port is busied out. up - At least one station on the port is not down or disabled. down - All stations on the port are either down or disabled. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility. |
| INT cdx6500GSCPStatPortSpeed | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.5 | INTEGER | read-only | The measured port speed in bits per second. |
| STR cdx6500GSCPStatLastStatsReset | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.6 | DisplayString | read-only | The time when the port statistics were last reset. |
| CTR cdx6500GSCPStatCharsIn | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.7 | Counter | read-only | Number of characters received on the line, including data and control characters. |
| CTR cdx6500GSCPStatCharsOut | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.8 | Counter | read-only | Number of characters transmitted on the line, including data and control characters. |
| INT cdx6500GSCPStatCharsInPerSec | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.9 | INTEGER | read-only | Number of characters received per second on the line, including data and control characters. |
| INT cdx6500GSCPStatCharsOutPerSec | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.10 | INTEGER | read-only | Number of characters transmitted per second on the line, including data and control characters. |
| CTR cdx6500GSCPStatOverrunErrs | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.11 | Counter | read-only | The number of overrun errors detected on the line. |
| CTR cdx6500GSCPStatChecksumErrs | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.12 | Counter | read-only | The number of frames received with checksum errors. |
| CTR cdx6500GSCPStatOverlengthFrames | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.13 | Counter | read-only | The number of frames received that were over length. |
| CTR cdx6500GSCPStatPollRespTimeOuts | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.14 | Counter | read-only | The number of times a poll was issued without response from the terminal. |
| CTR cdx6500GSCPStatIntercharTimeOuts | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.15 | Counter | read-only | The number of receive frames aborted because of inter-character timeouts. |
| CTR cdx6500GSCPStatAckTimeOuts | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.16 | Counter | read-only | The number of transmitted frames which were not acknowledged. |
| CTR cdx6500GSCPStatPADFrames | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.17 | Counter | read-only | The number of PAD frames received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCPStatSADFrames | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.18 | Counter | read-only | The number of SAD frames transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCPStatUADFrames | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.19 | Counter | read-only | The number of UAD frames transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCPStatBROFrames | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.20 | Counter | read-only | The number of BRO frames transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCPStatPADChars | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.21 | Counter | read-only | The number of PAD characters received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCPStatSADChars | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.22 | Counter | read-only | The number of SAD characters transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCPStatUADChars | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.23 | Counter | read-only | The number of UAD characters transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCPStatENQs | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.24 | Counter | read-only | The number of ENQ characters received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCPStatPACChars | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.25 | Counter | read-only | The number of PAC characters received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCPStatSACChars | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.26 | Counter | read-only | The number of SAC characters transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCPStatUACChars | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.27 | Counter | read-only | The number of UAC characters transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCPStatPolls | 1.3.6.1.4.1.449.2.1.3.1.1.30.1.28 | Counter | read-only | The number of polls transmitted (TPAD) or received (HPAD). |
| cdx6500PSTStationProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1.3 | |||
| cdx6500SPSTGSCStationTable | 1.3.6.1.4.1.449.2.1.3.1.3.7 | not-accessible | Statistics parameters relevant to GSC stations. | |
| cdx6500SPSTGSCStationEntry | 1.3.6.1.4.1.449.2.1.3.1.3.7.1 | not-accessible | This table holds statistics parameters pertaining to GSC stations. | |
| INT cdx6500GSCSStatPortNumber | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.1 | INTEGER | read-only | The port number of the GSC port. |
| INT cdx6500GSCSStatStationNum | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.2 | INTEGER | read-only | The GSC station number. |
| INT cdx6500GSCSStatPortType | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.3 | INTEGER | read-only | This indicates the port type. |
| INT cdx6500GSCSStatSubtype | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.4 | INTEGER | read-only | Indicates the sub-type of the associated port. gscHpad - Associated port is functioning as a host PAD. gscTpad - Associated port is functioning as a terminal PAD. |
| INT cdx6500GSCSStatStationAddress | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.5 | INTEGER | read-only | Configure station address. |
| INT cdx6500GSCSStatStationStatus | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.6 | INTEGER | read-only | The station status: disabled - Station is disabled. enabled - Station is enabled. busyOut - Station is busied out. up - Station is up. down - Station is down. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility. |
| STR cdx6500GSCSStatLastStatsReset | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.7 | DisplayString | read-only | Time when the station statistics were last reset. |
| CTR cdx6500GSCSStatCharsIn | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.8 | Counter | read-only | Number of characters received on the line, including data and control characters. |
| CTR cdx6500GSCSStatCharsOut | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.9 | Counter | read-only | Number of characters transmitted on the line, including data and control characters. |
| INT cdx6500GSCSStatCharsInPerSec | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.10 | INTEGER | read-only | Number of characters received per second on the line, including data and control characters. |
| INT cdx6500GSCSStatCharsOutPerSec | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.11 | INTEGER | read-only | Number of characters transmitted per second on the line, including data and control characters. |
| CTR cdx6500GSCSStatChecksumErrs | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.12 | Counter | read-only | The number of frames received with checksum errors. |
| CTR cdx6500GSCSStatOverlengthFrames | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.13 | Counter | read-only | The number of frames received that were overlength. |
| CTR cdx6500GSCSStatPollRespTimeOuts | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.14 | Counter | read-only | The number of times a poll was issued without response from the terminal (TPAD only). |
| CTR cdx6500GSCSStatIntercharTimeOuts | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.15 | Counter | read-only | The number of receive frames aborted because of inter-character timeouts. |
| CTR cdx6500GSCSStatAckTimeOuts | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.16 | Counter | read-only | The number of transmitted frames which were not acknowledged. |
| CTR cdx6500GSCSStatPADFrames | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.17 | Counter | read-only | The number of PAD frames received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatSADFrames | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.18 | Counter | read-only | The number of SAD frames transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCSStatUADFrames | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.19 | Counter | read-only | The number of UAD frames transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCSStatBROFrames | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.20 | Counter | read-only | The number of BRO frames transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCSStatPADChars | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.21 | Counter | read-only | The number of PAD characters received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatSADChars | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.22 | Counter | read-only | The number of SAD characters transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCSStatUADChars | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.23 | Counter | read-only | The number of UAD characters transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCSStatENQ | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.24 | Counter | read-only | The number of ENQ characters received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatPACChars | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.25 | Counter | read-only | The number of PAC characters received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatSACChars | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.26 | Counter | read-only | The number of SAC characters transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCSStatUACChars | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.27 | Counter | read-only | The number of UAC characters transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCSStatPolls | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.28 | Counter | read-only | The number of Polls transmitted (TPAD) or received (HPAD). |
| CTR cdx6500GSCSStatPADMessages | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.29 | Counter | read-only | The number of PAD Messages received (HPAD) or transmitted (TPAD). |
| CTR cdx6500GSCSStatUADMessages | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.30 | Counter | read-only | The number of UAD Messages received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatSADMessages | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.31 | Counter | read-only | The number of SAD Messages received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatBROMessages | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.32 | Counter | read-only | The number of BRO Messages received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatSolicitAbort | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.33 | Counter | read-only | The number of SOLICIT ABORT Messages received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatStatusEnq | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.34 | Counter | read-only | The number of STATUS ENQ Messages received (HPAD) or transmitted (TPAD). |
| CTR cdx6500GSCSStatDeviceUp | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.35 | Counter | read-only | The number of DEVICE UP Messages received (TPAD) or transmitted (HPAD). |
| CTR cdx6500GSCSStatDeviceDown | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.36 | Counter | read-only | The number of DEVICE DOWN Messages received (TPAD) or transmitted (HPAD). |
| INT cdx6500GSCSStatCallCurrentStatus | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.37 | INTEGER | read-only | The current status of the call. inhibited :Current Status = Disconnected. disconnected :Current Status = Disconnected. calling :Current Status = Calling. called :Current Status = Called. connected :Current Status = Connected (data transfer). notDefined :Current Status = Undefined. |
| STR cdx6500GSCSStatLastClrCauseCode | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.38 | DisplayString | read-only | Last clear cause code. |
| STR cdx6500GSCSStatLastClrDiagCode | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.39 | DisplayString | read-only | Last clear diagnostic code. |
| STR cdx6500GSCSStatLastInCalledAddress | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.40 | DisplayString | read-only | The called address in the last inbound call. |
| STR cdx6500GSCSStatLastInCallingAddress | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.41 | DisplayString | read-only | The calling address in the last inbound call. |
| STR cdx6500GSCSStatLastInCallFacilities | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.42 | DisplayString | read-only | The facilities in the last inbound call. |
| STR cdx6500GSCSStatLastInCallCUD | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.43 | DisplayString | read-only | The Call User Data in the last inbound call. |
| STR cdx6500GSCSStatLastOutCalledAddress | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.44 | DisplayString | read-only | The called address in the last outbound call. |
| STR cdx6500GSCSStatLastOutCallingAddress | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.45 | DisplayString | read-only | The calling address in the last outbound call. |
| STR cdx6500GSCSStatLastOutCallFacilities | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.46 | DisplayString | read-only | The facilities in the last outbound call. |
| STR cdx6500GSCSStatLastOutCallCUD | 1.3.6.1.4.1.449.2.1.3.1.3.7.1.47 | DisplayString | read-only | The Call User Data in the last outbound call. |
| cdx6500Controls | 1.3.6.1.4.1.449.2.1.4 | |||
| cdx6500ContGSC | 1.3.6.1.4.1.449.2.1.4.12 | |||
| cdx6500ContGSCPTable | 1.3.6.1.4.1.449.2.1.4.12.1 | not-accessible | This table contains the port control objects | |
| cdx6500ContGSCPTableEntry | 1.3.6.1.4.1.449.2.1.4.12.1.1 | not-accessible | Each entry represents a port control parameter. | |
| INT cdx6500ContGSCPPortNum | 1.3.6.1.4.1.449.2.1.4.12.1.1.1 | INTEGER | not-accessible | GSC port Number. |
| INT cdx6500ContGSCPBootPort | 1.3.6.1.4.1.449.2.1.4.12.1.1.2 | INTEGER | write-only | Boot the specified GSC port. boot : Boot the port noBoot : Do not boot the port. |
| INT cdx6500ContGSCPEnablePort | 1.3.6.1.4.1.449.2.1.4.12.1.1.3 | INTEGER | write-only | Enable the specified GSC port. enable : Enable the GSC port. noEnable : Do not enable the GSC port. |
| INT cdx6500ContGSCPDisablePort | 1.3.6.1.4.1.449.2.1.4.12.1.1.4 | INTEGER | write-only | Disable the specified GSC port. disable : Disable the GSC port. noDisable : Do not disable the GSC port. |
| cdx6500ContGSCSTable | 1.3.6.1.4.1.449.2.1.4.12.2 | not-accessible | This table contains the station control objects. | |
| cdx6500ContGSCSTableEntry | 1.3.6.1.4.1.449.2.1.4.12.2.1 | not-accessible | Each entry represents a station control parameter. | |
| INT cdx6500ContGSCSPortNum | 1.3.6.1.4.1.449.2.1.4.12.2.1.1 | INTEGER | not-accessible | The GSC Port Number. |
| INT cdx6500ContGSCSStnNum | 1.3.6.1.4.1.449.2.1.4.12.2.1.2 | INTEGER | not-accessible | The GSC Station Number. |
| INT cdx6500ContGSCSBootStation | 1.3.6.1.4.1.449.2.1.4.12.2.1.3 | INTEGER | write-only | Boot the specified GSC station boot : Boot the station. noBoot : Do not boot the station. |
| INT cdx6500ContGSCSEnableStation | 1.3.6.1.4.1.449.2.1.4.12.2.1.4 | INTEGER | write-only | Enable the specified GSC station. enable : Enable the Station. noEnable : Do not enable the Station. |
| INT cdx6500ContGSCSDisableStation | 1.3.6.1.4.1.449.2.1.4.12.2.1.5 | INTEGER | write-only | Disable the specified GSC station. disable : Disable the station. noDisable : Do not disable the station. |
RFC description
Generic switch control optimization MIB managing protocol optimization and performance tuning parameters.
Start monitoring Codex (Motorola) 6500 statistical multiplexer, GSC port module with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.